NL
Philips-Avent logo
Officiële handleiding

Philips-Avent SCF312

54 pagina's·2 MB·Babyverzorging·PDF·ENDEJA
Philips-Avent SCF312
Inhoudsopgave 48 secties GB · call free on 0800 331 6015 GB ONLY (9am–4.30pm Mon-Fri) · A1 A2 · IRL · … TonenVerbergen
Page 1 of the Philips-Avent SCF312 user manual — IT
Pagina 1 · klik om te vergroten
Pagina 1

GB

For our complete catalogue of mother and babycare products

A

B

call free on 0800 331 6015 GB ONLY (9am–4.30pm Mon-Fri)

A1 A2

Philips-Avent SCF312 — A1 A2 diagram (page 1)
Afb. 1
Philips-Avent SCF312 — A1 A2 diagram (page 1)
Afb. 2

IRL

call free on 1800 744 5477 IRL ONLY (9am–4.30pm Mon-Fri)

Philips-Avent SCF312 — IRL diagram (page 1)
Afb. 3

k

AU

1 300 364 474 (Australia National)

a

FR

Pour obtenir notre catalogue de produits de petite puériculture: 0805 025 510 (Appel gratuit sauf surcoût éventuel selon opérateur) De Suisse, composez le : 056 266 56 56 De Belgique / Luxembourg, composez le : 0800 80 190 / 0800 26 550

h

b

Philips-Avent SCF312 — h diagram (page 1)
Afb. 4 · h

m

NL

Bel voor meer informatie of een product catalogus de Philips AVENT consumentenlijn: Nederland: 0800-023 0076 (€ 0,25 p/m) België/Luxemburg: 0800 80 190 / 0800 26 550

n

d

IT

Per ricevere il nostro catalogo completo di prodotti per mamma e bimbo, chiama il: 800 088774 (Numero gratuito – Il vostro operatore telefonico potrebbe addebitarvi i costi della chiamata)

o

e

Philips-Avent SCF312 — o diagram (page 1)
Afb. 5 · o

A3

(dal Lunedì al Venerdì dalle 10.00 alle 17.30) Svizzera: Vivosan, Tel. 056 266 56 56

Philips-Avent SCF312 — A3 diagram (page 1)
Afb. 6

Breast pump – BPA-free Tire-lait sans bisphenol A (0% BPA) Handkolf – bevat geen BPA Tiralatte – no BPA

e

p

Single electronic breast pump Tire-lait électronique individuel Enkele Elektronische Borstkolf Tiralatte elettronico singolo

GB

j

www.philips.com/AVENT

FR

f

Philips AVENT, a business of Philips Electronics UK Ltd. Philips Centre, Guildford Business Park, Guildford, Surrey, GU2 8XH

q

NL

Trademarks owned by the Philips Group. © Koninklijke Philips Electronics N.V. All Rights Reserved.

IT

42133 5415 341

Page 3 of the Philips-Avent SCF312 user manual — p q
Pagina 3 · klik om te vergroten
Pagina 3

F

Philips-Avent SCF312 — F diagram (page 3)
Afb. 7
Philips-Avent SCF312 — F diagram (page 3)
Afb. 8

p q

Philips-Avent SCF312 — p q diagram (page 3)
Afb. 9 · p q
Philips-Avent SCF312 — p q diagram (page 3)
Afb. 10 · p q
Page 4 of the Philips-Avent SCF312 user manual — GB
Pagina 4 · klik om te vergroten
Pagina 4

GB

We’ve taken everything women loved about our classic manual breast pump – the soft petal massager and fingertip sensitive control that make it feel so gentle, natural and comfortable – and we’ve given it an electronic memory.

The single electronic breast pump learns from you. Begin by pumping manually, then touch the button and let the breast pump quietly continue your exact pumping rhythm.

Philips-Avent SCF312 — GB diagram (page 4)
Afb. 11

If at any time you want to vary the rhythm, touch the button again to revert to manual. The single electronic breast pump is totally responsive to your needs.

Relax and enjoy the experience because you’re always in complete control. And when you’re relaxed and comfortable, you express more milk, faster.

The single electronic breast pump is battery or mains powered for maximum flexibility and portability. Please take a few minutes to read through the ENTIRE INSTRUCTION LEAFLET before you use your Philips AVENT single electronic breast pump for the first time. PLEASE SAVE THESE INSTRUCTIONS. Unless advised otherwise by your health professional it is best to wait until your breastfeeding routine is established before expressing – usually around four weeks.

Page 5 of the Philips-Avent SCF312 user manual — *NEVER STERILISE OR IMMERSE IN WATER
Pagina 5 · klik om te vergroten
Pagina 5

Breast pump parts

Pump parts (diagram A1)

Control handle * (diagram B)

Control handle* Silicone diaphragm and stem White valve Pump body Milk container (125ml/4oz) Adaptor ring Stand (same as ) Let-down Massage Cushion Funnel cover (same as ) Battery pack* Mains power lead*

Power socket Control button Control handle Light

Battery pack * (diagram C)

Only the following batteries are compatible with the single electronic breast pvump Battery pack: Duracell Ultra M3, Duracell Plus, Energizer Ultra Plus, Duracell Accu (NiMH), Ansmann (NiMH). For Duracell Acc (NiMH) & Ansmann (NiMH) use/charge in accordance with manufacturers guidelines. Dispose of batteries as per manufacturer’s instructions.

Bottle parts (diagram A2)

Dome cap Extra soft AVENT Teat, Newborn flow (0m+) Screw ring Sealing base Sealing disc

Manual parts (diagram A3)

*NEVER STERILISE OR IMMERSE IN WATER

Power cable · Handle Pump cover

Page 6 of the Philips-Avent SCF312 user manual — Important safeguards
Pagina 6 · klik om te vergroten
Pagina 6

Important safeguards

READ ALL INSTRUCTIONS BEFORE USING YOUR PHILIPS AVENT SINGLE ELECTRONIC BREAST PUMP

When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following.

  • The breast pump is intended for repeated use by a single user only.
  • Always unplug from the electrical wall socket immediately after use.
  • Do not use while bathing.
  • Do not place or store the product where it can fall or be pulled into a bath or sink.
  • Do not place or drop the control handle, battery pack or mains power lead into water or other liquids.
  • Do not reach for a product that has fallen into water. Unplug from the wall socket immediately.
  • Do not allow children or pets to play with the control handle, battery pack, mains power lead or accessories as these parts may pose a choking or strangulation danger.
  • Before each use inspect the product, including mains power lead, for signs of damage. Never operate this product if it has a damaged lead or plug, if it is not working properly or if it has been dropped, damaged or has been submerged in water.
  • Only use attachments recommended by Philips AVENT.
  • Do not use outdoors with the mains power lead or where aerosol spray products are being used, or where oxygen is being administered.
  • Equipment not suitable for use in the presence of flammable anaesthetic mixture with air, or with oxygen or nitrous oxide.
  • Only use the mains power lead and battery pack supplied with the product.
  • There are no user serviceable parts inside the breast pump. Do not attempt to open, service or repair the breast pump yourself.
  • Keep leads away from heated surfaces.
  • This product is a personal care item and should not be shared between mothers.
  • Do not attempt to remove the pump body from your breast while under vacuum. Turn the unit off and break the seal between your breast and the pump funnel with your finger, then remove the pump from your breast.
  • Do not operate unless control handle is connected to a pump body.
  • Never use while pregnant, as pumping can induce labour.
  • Never use when sleepy or drowsy.
  • This appliance is intended for use by responsible persons, keep out of reach of small children and the infirm.
  • This appliance is not intended for use by persons including children with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Ensure the unit is not exposed to extreme heat or placed in direct sunlight. CAUTION – To reduce the risks of injury, device malfunction or failure:
  • The product should not be left unattended when plugged into an electrical wall socket.
  • Never drop or insert any foreign object into any opening.
  • Make sure the voltage of the mains power lead is compatible with the power source.
  • Plug the end of the mains power lead into the control handle first, then securely attach the wall plug into the electrical socket.
  • Although compliant with applicable EMC directives, this equipment may still be susceptible to excessive emissions and/or may interfere with more sensitive material.
  • Wash, rinse and sterilise the appropriate pump parts before each use.
  • Never put the control handle, battery pack or lead in water or a steriliser as you can cause permanent damage to the pump.
  • Do not continue pumping for more than five minutes at a time if no result is achieved.
  • Do not use antibacterial or abrasive cleaners/detergents when cleaning breast pump parts.
  • If the pressure generated is uncomfortable or causing pain, turn the unit off, break the seal between the breast and the pump body with your finger and remove the pump from your breast. 9
Page 7 of the Philips-Avent SCF312 user manual — Keeping your pump sterilised and compact for travel
Pagina 7 · klik om te vergroten
Pagina 7

How to clean and sterilise your pump

(see diagram A)

Philips-Avent SCF312 — (see diagram A) diagram (page 7)
Afb. 12 · (see diagram A)

the control handle (a), battery pack (i) or mains power lead (j).

These components DO NOT come into contact with your breast milk.

You can wipe the control handle clean, using a soft cloth.

Cleaning and sterilising the pump body and breast milk storage components

Before you use your breast pump for the first time and every time fore use:

Separate all parts, then wash in the dishwasher or in warm soapy water and rinse. Do not use antibacterial or abrasive cleaners/detergents.

Philips-Avent SCF312 — Cleaning and sterilising the pump body and breast milk storage components diagram (page 7)
Afb. 13 · Cleaning and sterilising the pump body and breast mi…

Sterilise all parts in a Philips AVENT steam steriliser or by boiling for 5 minutes. If using a Philips AVENT steam steriliser, the pump will remain sterile in the steriliser for a minimum of 6 hours, provided the lid is not removed.

Keeping your pump sterilised and compact for travel

After sterilising all parts, insert the white valve and diaphragm into the pump body. Clip the funnel cover (h) over the funnel and Let-down Massage Cushion (g) and screw the sealing base (n) onto the pump body (d) in place of the milk container.

n · d · h 10

Page 8 of the Philips-Avent SCF312 user manual — (see diagram D)
Pagina 8 · klik om te vergroten
Pagina 8

How to assemble your pump

(see diagram D)

1. With clean hands, insert the white valve (c) into the pump body (d) from the bottom making sure that the pointed side of the valve faces downwards.
2. Twist the milk container (e) onto the pump body (d) until securely in place.*
3. To ensure the pump doesn’t topple, insert the 125ml/4oz milk container into the stand provided (f).
4. Place the silicone diaphragm (b) into the pump body (d), making sure it fits securely around the edge, to create a seal (this is easier if the diaphragm is wet).
5. Carefully insert the Let-down Massage Cushion (g) into the pump body (d), making sure it completely covers the edge of the funnel (this is easier if the Let-down Massage Cushion is wet).
6. Firmly push the control handle (a) onto the pump body (d) so that it sits securely on top of the silicone diaphragm (b).
7. For mains use connect the mains power lead (j) to the control handle (a) and plug into an electrical wall socket.
8. For battery use, open the top of the battery pack (i) and insert 4 x AA batteries. Connect the power lead to the control handle (a).

* ALWAYS insert the adapter ring when using a polypropylene bottle

Page 9 of the Philips-Avent SCF312 user manual — To begin pumping
Pagina 9 · klik om te vergroten
Pagina 9

How to use your pump

(see diagram E)

Wash your hands thoroughly and make sure your breasts are clean. Relax in a comfortable chair, leaning slightly forward (use cushions to support your back). Make sure you have a glass of water nearby as expressing can be thirsty work. A photograph of your baby will help too.

To begin pumping

1. Switch on at the wall socket if using mains power. To turn the pump on, press and hold the control button for 2 seconds. The light on the top of the control handle will flash ORANGE and then turn to a solid GREEN to indicate that the pump is ready to use. If at any time the light is flashing red, stop and consult the ‘Troubleshooting guide’.
2. Bring the assembled pump to your breast. Position the cushion firmly onto your breast so as to create a perfect seal (ensure no strand of hair or piece of clothing is trapped). Using the control handle you can find your exact comfort level. As you press down on the handle, you will feel greater suction against your breast. You don’t need to squeeze the handle fully, only as far as feels comfortable for you.
3. Once comfortable, begin by gently squeezing the handle 5 or 6 times quite quickly, simulating the rapid suckling you usually feel when your baby is first put to the breast. Your milk will soon begin to flow and you can establish a slower, comfortable pumping pattern. Many mothers find that holding down the handle for 2 to 3 seconds at a time imitates the feeling of their baby breastfeeding.
4. When you have established a comfortable pumping rhythm with at least 2 squeezes, simply press the control button on the handle, and the electronic breast pump will automatically continue in the same way. The light on the control handle will turn from solid GREEN to a flashing GREEN . Your pattern will now be stored in the pump’s memory – even after the pump has been switched off!
Page 10 of the Philips-Avent SCF312 user manual — To collect and store your milk
Pagina 10 · klik om te vergroten
Pagina 10

To change your pumping rhythm

If at any time you want to change your pumping rhythm, press the control button and the pump will revert to manual pumping. The light will turn back to solid GREEN. You can now pump manually until you are comfortable again. Then press the control button again and the Single Electronic Breast Pump will continue your chosen rhythm.

To stop pumping

When you want to stop pumping, press the control handle and break the seal between the breast and the pump body with your finger. To switch off the pump, press and hold the control button for 2 seconds until the light turns off, then unplug the mains power lead from the wall socket. If you’re using the battery pack, disconnect from the control handle. If you forget to turn the pump off, it will switch itself off after 3 minutes to save battery power.

Battery Life

Batteries will last for approximately 6 hours. The light on the control handle will display a slow pulsing flash to warn you when it is time to replace them. There will be enough power for approximately 1 more pumping session, with no drop-off in performance, before the pump switches itself off.

To collect and store your milk

After you have expressed your milk, unscrew the pump body from the milk container (e). If you’re using AVENT breast milk containers, insert a sealing disc (o) into the screw ring (m) and twist it onto the milk container. If you’re using VIA, unscrew the adaptor and screw a lid onto the cup.

On average you will need to pump for 10 minutes to express 60-125ml/2-4oz. However, this is just a guide and varies from woman to woman. If you find that you regularly express more than 125ml/4oz per session, you can use a 260ml/9oz AVENT breast milk container or a 240ml/8oz VIA Cup.

Breast milk can be stored in the fridge or freezer in either sterile breast milk containers (125ml/4oz or 260ml/9oz or 330ml fitted with sealing discs) or in pre-sterilised VIA Cups.

Page 11 of the Philips-Avent SCF312 user manual — Disassembly
Pagina 11 · klik om te vergroten
Pagina 11

Do not overfill the milk container and be sure to keep it upright, otherwise it may leak.

Expressed milk should be refrigerated immediately.

Only milk collected with a sterile pump should be stored to be fed to your baby.

Expressed breast milk can be stored in the refrigerator for up to 48 hours (not in the door) or in the freezer for up to 3 months.

If you are storing freshly expressed milk in the fridge to add to during the day, only add milk which has been expressed into a sterile container. Milk can only be kept like this for a maximum of 48 hours from first expression, after which it must be used immediately or frozen for future use.

Frozen breast milk can be defrosted overnight in the refrigerator, heated gradually in warm water or heated with a Philips AVENT bottle and baby food warmer.

NB:

  • NEVER refreeze breast milk.
  • DO NOT add fresh breast milk to already frozen milk.
  • ALWAYS discard any milk that is left over at the end of a feed. Never heat milk in a microwave as this may destroy valuable nutrients and antibodies. In addition, the uneven heating may cause hot spots in the liquid which could cause burns to the throat.

Never immerse a frozen milk container or VIA Cup in boiling water as this may cause it to crack/split.

Never put boiling water directly into a VIA Cup, allow to cool for around 20 minutes before filling.

Disassembly

Philips-Avent SCF312 — Disassembly diagram (page 11)
Afb. 14 · Disassembly

Ensure the power is switched off at the wall socket and disconnect the mains power lead or battery pack from the control handle. Pull the control handle directly upwards away from the diaphragm then unhook it from the stem by moving it towards the funnel.

Page 12 of the Philips-Avent SCF312 user manual — Hints to help you succeed
Pagina 12 · klik om te vergroten
Pagina 12

Hints to help you succeed

Using a breast pump takes practice. You may need to make several attempts before you succeed, but because the single electronic breast pump is so simple and comfortable to use, you will soon get used to expressing milk.

1. Choose a quiet time when you’re not rushed and unlikely to be disturbed.
2. Having your baby or a photograph of your baby nearby can help encourage your milk to flow.
3. Warmth and relaxation can help so you might like to try expressing after a warm bath or shower.
4. Placing a warm cloth on your breasts for a few minutes before you start pumping can also encourage your milk flow and soothe painful breasts.
5. Try expressing from one breast while your baby is feeding from the other, or continue expressing just after a feed.
6. Repositioning the pump on your breast from time to time can help stimulate your milk ducts.
7. To relieve engorgement, we recommend gentle, slow pumping to relieve the pressure.

Practice with your pump to find the best pumping techniques for you. Don’t worry if your milk doesn’t flow immediately, relax and continue pumping. Do not continue pumping for more than 5 minutes at a time if NO result is achieved. Try expressing at another time during the day.

Page 13 of the Philips-Avent SCF312 user manual — How to use your manual breast pump (see diagram G)
Pagina 13 · klik om te vergroten
Pagina 13

Using your electronic pump as a manual breast pump

Your electronic breast pump can also be used as a manual pump. In this case, you simply need to replace the control handle with the manual handle (p) and pump cover (q) provided.

Assembling your manual breast pump (see diagram F)

Ensure you have disassembled, washed and sterilised all the parts.

Follow steps 1-5 as before (see diagram D), then proceed to step 6 and 7 (see diagram F):

6. Position the forked end of the handle (p) under the diaphragm stem (b) and push down gently on the handle until you hear it ‘click’ into place.
7. Click the pump cover (q) onto the pump body (d).

How to use your manual breast pump (see diagram G)

1. Bring the assembled pump to your breast. Position the Let-down Massage Cushion firmly onto your breast so as to create a perfect seal (ensure no strand of hair or piece of clothing is trapped).
2. Once comfortable, gently squeeze the handle 5 or 6 times fairly quickly to initiate let-down. When you see your milk beginning to flow, establish a rhythm of pumping to meet your own comfort level.
Page 14 of the Philips-Avent SCF312 user manual — FOLLOW OPERATING INSTRUCTIONS
Pagina 14 · klik om te vergroten
Pagina 14

Key to Control Handle Symbols

TYPE B APPLIED PART

GENERAL WARNING

DISPOSE OF THROUGH SEPARATE COLLECTION ROUTE FOR WASTE ELECTRICAL EQUIPMENT

FOLLOW OPERATING INSTRUCTIONS

EUROPEAN STANDARD

ONLY USE INDOORS CLASS II E Q UIPMENT

Technical Specifications

  • Mains Input Voltage 100 – 240 VAC
  • Mains Input Frequency 50 – 60 Hz
  • Supply voltage fluctuations not exceeding +/- 10% of the nominal voltage
  • Ambient Temperature range: +10˚C to +40˚C
  • Atmospheric Pressure: 700 to 1060hPa
  • Equipment rated for continuous operation
  • Maximum speed at maximum vacuum is 60 cycles per minute Guarantee

Philips AVENT guarantees that should the single electronic breast pump become faulty during 24 months from the date of purchase, it will be replaced free of charge during this time. Please return it to the retailer where it was purchased. Please keep your receipt as proof of purchase, together with a note of when and where purchased. For the Guarantee to be valid, please note:

  • The single electronic breast pump must be used according to the instructions in this booklet and connected to a suitable electricity supply or the battery pack provided.
  • The claim must not be a result of accident, misuse, dirt, neglect or fair wear and tear.

This Guarantee does not affect your statutory rights.

If the retailer is unable to help, please contact Philips AVENT Customer Services (see back cover for contact details).

Page 15 of the Philips-Avent SCF312 user manual — CONCERN SOLUTION Troubleshooting guide
Pagina 15 · klik om te vergroten
Pagina 15

CONCERN SOLUTION Troubleshooting guide

  • Check that all pump parts have been assembled correctly and that the valve is positioned correctly.
  • Ensure that the silicone diaphragm and Let-down Massage Cushion are fitted securely to the pump body and a perfect seal is created.
  • Make certain that the control handle is firmly in place.

No milk being expressed

  • Ensure the pump is correctly assembled and that suction is being created.
  • Relax and try again, as expression may improve after practice.
  • Refer to the ‘Hints to help you succeed’ section.

Pain in the breast area when expressing

  • You may be squeezing too hard. You do not need to use all the suction the pump can generate.
  • Try squeezing the handle more gently and remember the 2-3 second pumping rhythm.
  • Consult your health professional/ breastfeeding advisor.

Milk is drawn up the Let-down Massage Cushion

  • Remove and re-fit the Let-down Massage Cushion to ensure it is firmly attached and pushed far enough down the centre of the funnel.
  • Try leaning slightly forward.
  • Contact Philips AVENT Customer Services for replacements (see back cover for contact details). Lost or broken parts

Lack of suction

Page 16 of the Philips-Avent SCF312 user manual — CONCERN SOLUTION Troubleshooting guide
Pagina 16 · klik om te vergroten
Pagina 16

Cracking or discolouration of pump/bottle parts

  • Avoid contact with antibacterial or abrasive detergents/cleaners as they can damage the plastic. Combinations of detergents, cleaning products, sterilising solution, softened water and temperature fluctuations may, under certain circumstances, cause the plastic to crack. If this occurs, do not use. The pump body and breast milk containers are dishwasher safe but food colourings may discolour them. Follow guidelines in ‘How to clean and sterilise your pump’.
  • Keep the product out of direct sunlight, as prolonged exposure may cause discolouration.
  • Ensure the pump is correctly assembled and switched on with the power indicator illuminated ‘ GREEN ’.
  • Make sure the lead between the electrical wall socket or battery pack and the pump is correctly connected.

Pump light flashing RED

  • Pump light flashing RED with delays (3 flashes, delay, 3 flashes etc.): If the pump works properly in Manual Control Mode but does not replicate in Automatic Mode, the handle rhythm may have been too fast for optimal milk expression. The machine is set not to follow. Push the control button to return to Manual Control Mode and use a slower handle rhythm.
  • If this does not help and the power light still flashes RED , the pump has detected a vacuum fault. Disconnect the power and check the control handle and diaphragm for obstruction or damage.
  • Pump light flashing RED continuously: Low battery warning. Replace the batteries.

Difficulties separating the control handle from the pump body

  • The pump must be switched off via the control button in order to separate these parts. If the batteries go flat mid-pumping, you may experience difficulty. Replace the batteries or connect the pump to the mains. Turn the pump on by holding down the control button for 2 seconds – the light will turn GREEN . Now turn it off by holding the button for 2 seconds – the light will go off. You can now disconnect the pump from the power supply and should be able to separate the parts.

Pump not responding

Vraag stellen over de Philips-Avent SCF312

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Philips-Avent SCF312

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Philips-Avent SCF312 handleiding-pdf

54 pagina's·2 MB·Babyverzorging·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…