For our complete catalogue of mother and babycare products
B


call free on 1800 744 5477 IRL ONLY (9am–4.30pm Mon-Fri)

AU
1 300 364 474 (Australia National)
a
FR
Pour obtenir notre catalogue de produits de petite puériculture: 0805 025 510 (Appel gratuit sauf surcoût éventuel selon opérateur) De Suisse, composez le : 056 266 56 56 De Belgique / Luxembourg, composez le : 0800 80 190 / 0800 26 550
b

NL
Bel voor meer informatie of een product catalogus de Philips AVENT consumentenlijn: Nederland: 0800-023 0076 (€ 0,25 p/m) België/Luxemburg: 0800 80 190 / 0800 26 550
d
IT
Per ricevere il nostro catalogo completo di prodotti per mamma e bimbo, chiama il: 800 088774 (Numero gratuito – Il vostro operatore telefonico potrebbe addebitarvi i costi della chiamata)
e

(dal Lunedì al Venerdì dalle 10.00 alle 17.30) Svizzera: Vivosan, Tel. 056 266 56 56

Breast pump – BPA-free Tire-lait sans bisphenol A (0% BPA) Handkolf – bevat geen BPA Tiralatte – no BPA
p
Single electronic breast pump Tire-lait électronique individuel Enkele Elektronische Borstkolf Tiralatte elettronico singolo
www.philips.com/AVENT
FR
f
Philips AVENT, a business of Philips Electronics UK Ltd. Philips Centre, Guildford Business Park, Guildford, Surrey, GU2 8XH
NL
Trademarks owned by the Philips Group. © Koninklijke Philips Electronics N.V. All Rights Reserved.
42133 5415 341






We’ve taken everything women loved about our classic manual breast pump – the soft petal massager and fingertip sensitive control that make it feel so gentle, natural and comfortable – and we’ve given it an electronic memory.
The single electronic breast pump learns from you. Begin by pumping manually, then touch the button and let the breast pump quietly continue your exact pumping rhythm.

If at any time you want to vary the rhythm, touch the button again to revert to manual. The single electronic breast pump is totally responsive to your needs.
Relax and enjoy the experience because you’re always in complete control. And when you’re relaxed and comfortable, you express more milk, faster.
The single electronic breast pump is battery or mains powered for maximum flexibility and portability. Please take a few minutes to read through the ENTIRE INSTRUCTION LEAFLET before you use your Philips AVENT single electronic breast pump for the first time. PLEASE SAVE THESE INSTRUCTIONS. Unless advised otherwise by your health professional it is best to wait until your breastfeeding routine is established before expressing – usually around four weeks.

Pump parts (diagram A1)
Control handle * (diagram B)
Control handle* Silicone diaphragm and stem White valve Pump body Milk container (125ml/4oz) Adaptor ring Stand (same as ) Let-down Massage Cushion Funnel cover (same as ) Battery pack* Mains power lead*
Power socket Control button Control handle Light
Only the following batteries are compatible with the single electronic breast pvump Battery pack: Duracell Ultra M3, Duracell Plus, Energizer Ultra Plus, Duracell Accu (NiMH), Ansmann (NiMH). For Duracell Acc (NiMH) & Ansmann (NiMH) use/charge in accordance with manufacturers guidelines. Dispose of batteries as per manufacturer’s instructions.
Dome cap Extra soft AVENT Teat, Newborn flow (0m+) Screw ring Sealing base Sealing disc
Power cable · Handle Pump cover

READ ALL INSTRUCTIONS BEFORE USING YOUR PHILIPS AVENT SINGLE ELECTRONIC BREAST PUMP
When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following.


the control handle (a), battery pack (i) or mains power lead (j).
These components DO NOT come into contact with your breast milk.
You can wipe the control handle clean, using a soft cloth.
Before you use your breast pump for the first time and every time fore use:
Separate all parts, then wash in the dishwasher or in warm soapy water and rinse. Do not use antibacterial or abrasive cleaners/detergents.

Sterilise all parts in a Philips AVENT steam steriliser or by boiling for 5 minutes. If using a Philips AVENT steam steriliser, the pump will remain sterile in the steriliser for a minimum of 6 hours, provided the lid is not removed.
After sterilising all parts, insert the white valve and diaphragm into the pump body. Clip the funnel cover (h) over the funnel and Let-down Massage Cushion (g) and screw the sealing base (n) onto the pump body (d) in place of the milk container.
n · d · h 10

* ALWAYS insert the adapter ring when using a polypropylene bottle

Wash your hands thoroughly and make sure your breasts are clean. Relax in a comfortable chair, leaning slightly forward (use cushions to support your back). Make sure you have a glass of water nearby as expressing can be thirsty work. A photograph of your baby will help too.

If at any time you want to change your pumping rhythm, press the control button and the pump will revert to manual pumping. The light will turn back to solid GREEN. You can now pump manually until you are comfortable again. Then press the control button again and the Single Electronic Breast Pump will continue your chosen rhythm.
When you want to stop pumping, press the control handle and break the seal between the breast and the pump body with your finger. To switch off the pump, press and hold the control button for 2 seconds until the light turns off, then unplug the mains power lead from the wall socket. If you’re using the battery pack, disconnect from the control handle. If you forget to turn the pump off, it will switch itself off after 3 minutes to save battery power.
Batteries will last for approximately 6 hours. The light on the control handle will display a slow pulsing flash to warn you when it is time to replace them. There will be enough power for approximately 1 more pumping session, with no drop-off in performance, before the pump switches itself off.
After you have expressed your milk, unscrew the pump body from the milk container (e). If you’re using AVENT breast milk containers, insert a sealing disc (o) into the screw ring (m) and twist it onto the milk container. If you’re using VIA, unscrew the adaptor and screw a lid onto the cup.
On average you will need to pump for 10 minutes to express 60-125ml/2-4oz. However, this is just a guide and varies from woman to woman. If you find that you regularly express more than 125ml/4oz per session, you can use a 260ml/9oz AVENT breast milk container or a 240ml/8oz VIA Cup.
Breast milk can be stored in the fridge or freezer in either sterile breast milk containers (125ml/4oz or 260ml/9oz or 330ml fitted with sealing discs) or in pre-sterilised VIA Cups.

Do not overfill the milk container and be sure to keep it upright, otherwise it may leak.
Expressed milk should be refrigerated immediately.
Only milk collected with a sterile pump should be stored to be fed to your baby.
Expressed breast milk can be stored in the refrigerator for up to 48 hours (not in the door) or in the freezer for up to 3 months.
If you are storing freshly expressed milk in the fridge to add to during the day, only add milk which has been expressed into a sterile container. Milk can only be kept like this for a maximum of 48 hours from first expression, after which it must be used immediately or frozen for future use.
Frozen breast milk can be defrosted overnight in the refrigerator, heated gradually in warm water or heated with a Philips AVENT bottle and baby food warmer.
Never immerse a frozen milk container or VIA Cup in boiling water as this may cause it to crack/split.
Never put boiling water directly into a VIA Cup, allow to cool for around 20 minutes before filling.

Ensure the power is switched off at the wall socket and disconnect the mains power lead or battery pack from the control handle. Pull the control handle directly upwards away from the diaphragm then unhook it from the stem by moving it towards the funnel.

Using a breast pump takes practice. You may need to make several attempts before you succeed, but because the single electronic breast pump is so simple and comfortable to use, you will soon get used to expressing milk.
Practice with your pump to find the best pumping techniques for you. Don’t worry if your milk doesn’t flow immediately, relax and continue pumping. Do not continue pumping for more than 5 minutes at a time if NO result is achieved. Try expressing at another time during the day.

Your electronic breast pump can also be used as a manual pump. In this case, you simply need to replace the control handle with the manual handle (p) and pump cover (q) provided.
Ensure you have disassembled, washed and sterilised all the parts.
Follow steps 1-5 as before (see diagram D), then proceed to step 6 and 7 (see diagram F):

GENERAL WARNING
DISPOSE OF THROUGH SEPARATE COLLECTION ROUTE FOR WASTE ELECTRICAL EQUIPMENT
EUROPEAN STANDARD
ONLY USE INDOORS CLASS II E Q UIPMENT
Technical Specifications
Philips AVENT guarantees that should the single electronic breast pump become faulty during 24 months from the date of purchase, it will be replaced free of charge during this time. Please return it to the retailer where it was purchased. Please keep your receipt as proof of purchase, together with a note of when and where purchased. For the Guarantee to be valid, please note:
This Guarantee does not affect your statutory rights.
If the retailer is unable to help, please contact Philips AVENT Customer Services (see back cover for contact details).

No milk being expressed
Pain in the breast area when expressing
Milk is drawn up the Let-down Massage Cushion
Lack of suction

Cracking or discolouration of pump/bottle parts
Pump light flashing RED
Difficulties separating the control handle from the pump body
Pump not responding
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.