Congratulations with the purchase of your dehumidifier. You have acquired a high quality

product which will give you many years of pleasure, if you use it responsibly. Please read

the user’s manual first in order to ensure the optimum life span of your dehumidifier. On

behalf of the manufacturer, we provide a two-year warranty on material- or manufacturing

defects.

Enjoy your dehumidifier.

PVG Holding B.V.

1 PLEASE READ THE USER’S MANUAL FIRST.

2 IF YOU HAVE ANY DOUBTS, CONSULT YOUR DEALER.

Dear Sir, Madam, · Yours sincerely, · Customer Service Department

Page 2 of the Qlima D210 user manual — E
Pagina 2 · klik om te vergroten
Pagina 2

IMPORTANT COMPONENTS

A

B

Qlima D210 — IMPORTANT COMPONENTS diagram (page 2)
Afb. 1

E

F

G

H

Show 9 more labels / short text on this page
Front shell · Outlet · Handle · Control Panel · Filter box · Back shell · Tank · Rubber feet · Supply cord
Page 3 of the Qlima D210 user manual — SAFETY INSTRUCTIONS
Pagina 3 · klik om te vergroten
Pagina 3

SAFETY INSTRUCTIONS

Read this user manual carefully before using the appliance and keep it for future reference. Install this device only when it complies with local/national leg- islation, ordinances and standards. This product is intended to be used as a dehumidifier in residential houses and is only suitable for use in dry locations, in normal household conditions, indoors in living room, kitchen and garage. This unit is only suitable for earthed sockets, connection voltage 220-240 V. / ~50 Hz.

  • GENERAL
  • To obtain optimum performance from your dehumidifier, do not place it near a radiator or any other heat source.
  • Ensure that all windows are closed in order to achieve maximum efficiency.
  • The capacity of the dehumidifier depends on the temperature and the humidity in the room. At lower temperatures, less moisture will be removed.
  • Ensure that the screen filter is kept clean. This prevents unnecessary power consumption and guarantees optimum efficiency.
  • If the power supply has been interrupted, the dehumidifier will restart after three minutes. The automatic delay protects the compressor.
Page 4 of the Qlima D210 user manual — SAFETY INSTRUCTIONS
Pagina 4 · klik om te vergroten
Pagina 4
  • Before connecting the unit, check the following:
  • The voltage supply must correspond with the mains voltage stated on the rating label.
  • The socket and power supply must be suitable for the current stated on the rating label.
  • The plug on the cable of the device must fit into the wall socket.
  • The device must be placed on a flat and stable surface.

The electricity supply to the device must be checked by a recognised professional if you have any doubts regarding the compatibility.

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • This device is manufactured according to CE safety standards. Nevertheless, you must take care, as with any other electrical device.
  • Do not cover the air inlet and outlet grill.
  • Empty the water reservoir before moving the unit.
  • Never allow the device to come into contact with chemicals.
  • Never spray the unit with or submerge in water
  • Do not insert objects into the openings of the unit.
  • Always remove the plug from the electric power supply before cleaning or replacing the unit or components of the unit.
  • Never use an extension cable to connect the device to the electric power supply. If there is no suitable, earthed wall socket available, have one installed by a recognised electrician.
Page 5 of the Qlima D210 user manual — SAFETY INSTRUCTIONS
Pagina 5 · klik om te vergroten
Pagina 5
  • Children should be supervised to ensure that they do not play with the appliance.
  • Have any repairs only carried out by a recognised service engineer or your supplier. Follow the instructions for use and maintenance as indicated in the user manual of this device.
  • Always remove the plug of the unit from the wall socket when it is not in use.
  • A damaged power cord or plug must always be replaced by a recognised electrician or your supplier.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • If the mains cord is damaged, you must have it replaced by a service centre authorised by Qlima or similarly qualified persons in order to avoid a hazard. G
  • ATTENTION!
  • Never use the device with a damaged power cord, plug, cabinet or control panel. Never trap the power cord or allow it to come into contact with sharp edges.
  • Failing to follow the instructions may lead to nullification of the guarantee on this device.
  • Do not place the dehumidifier in bathrooms or in other places where it is likely that water could be sprayed on the dehumidifier.
Page 6 of the Qlima D210 user manual — SAFETY INSTRUCTIONS
Pagina 6 · klik om te vergroten
Pagina 6

Specific information regarding appliances with R 290 refrigerant gas.

  • Thoroughly read all of the warnings.
  • When defrosting and cleaning the aplliance , do not use any tools other than those recommended by the manufacturing company.
  • The appliance must be placed in an area without any continuously sources of ignition (for example: open flames , gas or electrical appliances in operation).
  • Do not puncture and do not burn.
  • This appliance contains Y g (see rating label back of unit ) of R290 refrigerant gas.
  • R290 is a refrigerant gas that complies with the European directives on the environment. Do not puncture any part of the refrigerant circuit. Be aware the refrigerants may not contain an odour.
  • If the appliance is installed, operated or stored in a nonventilated area, the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
  • The appliance must be stored in such a way as to prevent mechanical failure.
  • Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry.
  • Repairs must be performed based on the recommendation from the manufacturing company. Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrigerants.
Page 7 of the Qlima D210 user manual — from 00-01-02……23-24.It is the programmed time to switch the machine. The 4
Pagina 7 · klik om te vergroten
Pagina 7

REQUIRED DISTANCE

Qlima D210 — REQUIRED DISTANCE diagram (page 7)
Afb. 2

Respect the required distance of the device to walls and other objects. See illustration 2.

CONTROL PANEL

1 2 3 4

Qlima D210 — CONTROL PANEL diagram (page 7)
Afb. 3

A B C D

LED INDICATORS

1. WATER FULL-LED Red
2. COMP-LED Green
3. DEFROST Green
4. TIMER-LED Orange

HUMIDITY LEVEL & TIMER 2 DIGIT DISPLAY

The indicator features 3 functions:

1. when you set the humidity, it will indicate the humidity that you have selected
2. when you program the time for the unit to turn on and off, it will show the hours.
3. When the environment humidity is lower than 35%, it will show “LO”
4. When the environment humidity is higher than 95%, it will show “HI”

PUSH BUTTON FUNCTIONS

A. Power Push Button

B. DOWN Push Button

C. UP Push Button

D. Timer Push Button

OPERATION

Qlima D210 — OPERATION diagram (page 7)
Afb. 4
1. Press button once to start operation. Press it again to stop operation.
2. Press or button to set the desired humidity level in the room, which can be set

from 30% to 90% at 5% intervals. After a period of working, when environment

humidity is lower than the selected humidity by 2%, compressor will stop. When

environment humidity is equel to or higher than the selected humidity by 3%,

compressor will restart after the 3-minute compressor protection time.

3. Press button to start the timer setting. Press the button to program the time

when the unit turns on and turns off. If you want to cancel the timer programming,

press the button to adjust the time at 00, and press the button, it will be circulate

from 00-01-02……23-24.It is the programmed time to switch the machine. The 4

20 cm · 20 cm

Page 8 of the Qlima D210 user manual — NOTE
Pagina 8 · klik om te vergroten
Pagina 8

programmed time will be cancelled when to switch compressor manually each time.

The programmed time remains unchanged if the machine stops to work due to

water full or during defrosting.

WATER DRAINAGE

When the drainage tank is full, the tank full indicator light will turn on, the operation will

stop automatically and the buzzer will beep 15 times to alert the user, that the water need

to be emptied from the drainage tank.

EMPTYING THE DRAINAGE TANK

1. Lightly press on the sides of the tank with both hands and pull the tank out gently.
Qlima D210 — EMPTYING THE DRAINAGE TANK diagram (page 8)
Afb. 5
2. Discard the collected water.
Qlima D210 — EMPTYING THE DRAINAGE TANK diagram (page 8)
Afb. 6

NOTE

1. Do not remove the float from the water tank. The water full sensor will no longer

be able to detect the water level correctly without the float and water may leak

from the water tank.

Qlima D210 — NOTE diagram (page 8)
Afb. 7
2. If the drainage tank is dirty, wash it with cold or lukewarm water. Do not use

detergent, scouring pads, chemically treated dust cloths, gasoline, benzene,

thinner, or other solvents, as these can scratch and damage the tank and cause

water leakage.

Page 9 of the Qlima D210 user manual — B. TO CLEAN THE AIR FILTER
Pagina 9 · klik om te vergroten
Pagina 9
3. When replacing the drainage tank, press the tank firmly into place with both

hands. If the tank is not positioned properly, the “TANK FULL” sensor will be

activated, and the dehumidifier will not operate.

CONTINUOUS WATER DRAINAGE

The unit features a continuous drainage port. Using a plastic pipe (with an inner diameter

of 10mm) inserts into drain hole (on intermediate plate), reach out from side of water

tank, install it in place, and arrange the drain pipe. The water in the drainage tank can be

continuously drained out from the continuous port on the unit.

Qlima D210 — CONTINUOUS WATER DRAINAGE diagram (page 9)
Afb. 8

MAINTENANCE

CLEANING THE DEHUMIDIFIER

A. TO CLEAN THE BODY

Wipe it with a soft damp cloth.

B. TO CLEAN THE AIR FILTER

1. Open the inlet grill firstly and remove the air filter.
Qlima D210 — B. TO CLEAN THE AIR FILTER diagram (page 9)
Afb. 9
2. Clean the air filter

Run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the

air filter is exceptionally dirty, wash it with warm water and a mild cleanser and dry

thoroughly.

Page 10 of the Qlima D210 user manual — TROUBLE SHOOTING
Pagina 10 · klik om te vergroten
Pagina 10
Qlima D210 — STORAGE diagram (page 10)
Afb. 10
3. Attach the air filter

Insert the filter into the grill smoothly, and place the inlet grill into right place.

Qlima D210 — STORAGE diagram (page 10)
Afb. 11

STORAGE

If the machine will not be used for a long period of time, take the following steps:

1. Remove the plug from the socket and empty the container. Allow the container and

the dehumidifier to dry completely.

2. Clean the air filter.
3. Store the device in a dust-free location, preferably covered with a sheet of plastic.

TROUBLE SHOOTING

Check the following before contacting technical support:

The powercord is not connected. Insert the plug into the wall out- let.

The water container is full. Remove the water from the con- tainer.

The unit does not work.

The water container has not been replaced correctly.

Place the water container in the correct position.

Is the temperature of the room above 35˚C or below 5˚C?

The protection device is activated and the unit cannot be started.

The air filter is clogged. Clean the air filter.

The temperature or relative humidity in the room where the device is operating is too low.

It is normal that the device does not dehumidify in these condi- tions.

The device does not dehumidify.

Is the intake duct or discharge duct obstructed?

Remove the obstruction from the discharge duct or intake duct.

Problem Cause Solution

Page 11 of the Qlima D210 user manual — CONDITIONS OF WARRANTY
Pagina 11 · klik om te vergroten
Pagina 11

The room is too large. We recommend using a dehu- midifier with a greater capacity.

The dehumidifier works, but reduces the relative humidity insufficiently.

There are too many sources of humidity.

We recommend using a dehu- midifier with a greater capacity.

There is too much ventilation. Reduce ventilation (e.g. close cur- tains and shut doors).

Clean the air filter as instructed under “Cleaning the dehumidi- fier”.

No air is discharged Is the air filter clogged?

Is the unit tilted or unsteady? Move the unit to a stable, sturdy location.

Clean the air filter as instructed under “Cleaning the dehumidi- fier”.

Is the air filter clogged?

E1 code Pipe temperature sensor failed Replace pipe temperature sensor

CONDITIONS OF WARRANTY

There is a two-year warranty on your dehumidifier from the date of purchase. All material

or manufacturing defects will be repaired free of charge.

The following applies:

  • All claims for compensation, including consequential damage, will not be entertained.
  • Any repairs or replacement of components during the warranty period will not result

in an extension of the warranty period.

  • The warranty will expire if any alterations have been made, not genuine components

have been fitted or if the dehumidifier has been repaired by a third party.

  • Components subject to normal wear and tear, such as the air filter, are not covered by

the warranty.

  • The warranty is only valid on presentation of the original, unaltered, and date-

stamped purchase receipt.

  • The warranty does not cover damage caused by actions that deviate from those as

described in the user’s manual or by neglect.

  • Transportation costs and the risks involved during the transportation of the

dehumidifier or components shall always be for the account of the purchaser.

To prevent unnecessary expenses, we recommend that you always carefully read the user’s

manual first. If this does not provide a solution, take the dehumidifier to your distributor

for repair.

Operation is noisy

Page 12 of the Qlima D210 user manual — TECHNICAL SPECIFICATIONS
Pagina 12 · klik om te vergroten
Pagina 12

TECHNICAL SPECIFICATIONS

Qlima D210 — TECHNICAL SPECIFICATIONS diagram (page 12)
Afb. 12

Power supply V / Hz / Ph 220-240/50/1 220-240/50/1

Dehumidifying capacity (moisture removal at 30ºC, 80%RH) L / 24h 10 16

Dehumidifying capacity (moisture removal at 27ºC, 60%RH) L / 24h 5 8

For rooms up to * m3 40 - 60 70 - 100

Operating range °C 5 - 35 5 - 35

Refrigerant type / charge r / gr R290 / 45 R290 / 45

Pressure suction / discharge bar 10 / 26 10 / 26

Dimensions (w x d x h) mm 276 x 185 x 480 276 x 185 x 480

* To be used as indication

Subject to change without prior notice.

Do not dispose of electrical appliances as unsorted municipal waste, use separate

collection facilities. Contact your local government for information regarding the

collection systems available. If electrical appliances are disposed of in landfills or

dumps, hazardous substances can leak into the groundwater and get into the

food chain, damaging your health and well-being. When replacing old appliances

with new once, the retailer is legally obligated to take back your old appliance for

disposal at least for free of charge.

This equipment contains R290 refrigerant in the amount as stated in the table

above. Do not vent R290 into atmosphere: R290, is a fluorinated greenhouse gas

with a Global Warming Potential (GWP) = 3

Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
The unit does not work.The powercord is not connected.Insert the plug into the wall out- let. p.10
The unit does not work.The water container is full.Remove the water from the con- tainer. p.10
The unit does not work.The water container has not been replaced correctly.Place the water container in the correct position. p.10
The unit does not work.Is the temperature of the room above 35˚C or below 5˚C?The protection device is activated and the unit cannot be started. p.10
The device does not dehumidify.The air filter is clogged.Clean the air filter. p.10
The device does not dehumidify.The temperature or relative humidity in the room where the device is operating is too low.It is normal that the device does not dehumidify in these condi- tions. p.10
The device does not dehumidify.Is the intake duct or discharge duct obstructed?Remove the obstruction from the discharge duct or intake duct. p.10

Vraag stellen over de Qlima D210

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Qlima D210

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Qlima D210 handleiding-pdf

172 pagina's·2.1 MB·Luchtbevochtiger/-ontvochtiger·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…