This heater is for outdoor use only. Indoor
use is dangerous and strictly forbidden. Always use in amply ventilated areas. An



appliance in a safe way and understand the hazards involved. • Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenan- ce.
rules, instructions and explanation, the warranty will no longer be valid, and the
manufacturer will no longer deal with any damage to the appliance and/or your
environment under the warranty.


The manufacturer is not responsible for any harm or damage if attention is
not paid to the points described above. The use of this product and the elements required for that purpose is enti-
rely at the end user’s own risk.
HEATER LOCATION AND CLEARANCE Always maintain: (picture 1) - 120 cm clearance from combustible materials, - minimum 100 cm top clearance - minimum 100 cm side clearance - Heater must only be placed and used on a firm, level and stable under-
ground.
GAS REQUIREMENTS Use propane, butane or LGP only. See rating label on the appliance. • Maximum size of cylinder suitable for the appliance is Ø 30 cm x (60-65) cm
(high) (*). Inner dimension of stand with supporting (*) height depends on the size and type of your gas regulator • The appliance requires approved gas hose in 140 cm length and a gas regula-
ding on countries. • The installation must conform to local codes, or in the absence of local codes,
to the standard for the storage and handling of liquid petroleum gases. • A dented, rusted or damaged gas cylinder may be hazardous and should be
LEAK TESTING Gas connections on the heater are leak tested at the factory prior to ship-
ment. A complete gas tightness check must be performed at the installation site due to possible mishandling in shipment and/or installation or because of excessive pressure being applied to the heater. The heater must be chec- kedwith a full cylinder. 1. Make sure the safety control valve is in the OFF position. 2. Make a soapy water solution of one part liquid detergent and one part
water. The soapy water solution can be applied with a spray bottle, brush or rag to all gas connections. Soap bubbles will appear in case of a Ieak.
WARNING: Never leak test while smoking!


alight, the gas supply shall be shut off and the appliance shall be investiga- ted and rectified before it is used again.
3. Turn the gas supply ON. And check all the connections with the soapy
water solution. No bubbles may appear! 4. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then
turn the gas supply ON and recheck. Contact your dealer or gas supplier for assistance if bubbles continue to appear.
>30% of Total wall area to be open and unrestricted
Open side must be >25% of total wall area

SPECIFICATIONS Max.Wattage: 13 kW Min. Wattage: 5 kW Gas Consumption: 450 g/hr-945 g/hr Height: 224 cm including stand
Gas type propane, butane or LPG only
Countries of des- tination (*)
NL-NO-DK-FIN-SE
Gas Category I3+ (28-30/37) I3 B/P (30)
Pressure (mBar) 28-30/37 28-30
(*) This appliance is not suitable for Germany, Austria, Swiss
picture 2. • Use 3 pcs M8 x 16 mm bolts to join the post brackets (9) and base (10).
Model PGU2013

brackets (9). Tighten the bolts and nuts.
screen (2). • Connect the gas hose (QA1) to the gas connector. (picture 7)
Please note - The gas hose (QA1) is NOT included with the heater. Hose must be purchased
separately - Minimum / Maximum length gas hose: 140-160 cm - Screw connection (France G1/2) is fitted as standard - Hoses Ø 8-13 mm. can be fitted as well. When required: use the multi coun-
try connector (picture 12) supplied. Fitting of the multi country connector is described in the separate manual supplied in with the included multi country kit. When using the multi country connector: ALWAYS make sure to use hose clamps! • For gas hose with threaded connectors: bind 2 or more rounds of plumbing
tape around the gas pipe before connecting the gas hose for security. • Bind 2 or more rounds of Teflon plumbing tape around the gas burner inlet
connector and connect the gas pipe. Use a wrench to tighten the connection. • Fix the completed burner unit to the post by 4 pcs M6 x10 mm bolts.(picture
tion as supplied with the gas hose and/or supplied with the gas regulator.
mounting instruction as supplied together with the gas regulator and/or the gas cilinder • Put gas cylinder on the base (10).
TO TURN ON THE HEATER Check that the regulator seal is correctly fitted and able to fulfil its function. 4
8)

a) Open the valve on the gas supply cylinder. b) Press and turn the variable control knob (5) to PILOT position (counter- clockwise 90°). c) Press down the variable control knob and hold for 30 seconds. While holding down the variable control knob press the igniter button several times until the pilot flame ignited. Release the variable control knob 10~20 seconds after the ignition.
Note: 1. If a new tank has just been connected, please allow at least one minute or more for the air in the gas pipeline to purge out through the pilot hole, 2. When lighting the pilot flame make sure that the variable control knob is continuously depressed while pressing the igniter button. Variable control knob can be released after the pilot flame lit for 10-20 seconds. 3. Pilot flame can be watched and checked from the peephole Iocated on the base of burnerhead . If the pilot flame does not light or it goes out, repeat step c.

d) Turn the variable controI knob to LO and Ieave it there for 5 minutes or more before turning the knob to desired temperaturesetting. e) If the burner flame goes out accidentally or it is blown out by wind, turn off the heater and wait at Ieast 5 minutes or more to let the gas dissipate before re-lighting to avoid possible gas explosion. Repeat steps b to d.
TO TURN OFF THE HEATER a) Turn the variable control knob to PILOT position. b) Press and turn the variable control knob to OFF position. c) Turn off the valve on the gas cylinder and disconnect the cylinder.
for Ieak before use. But at least once a month and each time the gas cylinder is changed. Check the hose assembly for sign of extreme abrasion, cuts or wears. Suspected areas should be Ieak tested. If the hose Ieaks, it must be replaced with a new one that conforms to IocaI standard codes. ). If it shows signs of cracking, splitting or other deterioration it shall be exchanged for new hose of the same length and of the equivalent quality. • Make sure the ventilation opening of the cylinder enclosure, controI com-
ting a hot heater. • Replace the gas tube/hose within the interval described with the hose.

cap from the cylinder valve. • Check for the presence and good state of the gasket before connecting the
from any ignition source (candle, cigarettes, other flame producing applian- ces, ...).
must not be stored in garage or any other enclosed area. Only store in venti- lated area! • Storage of heater indoors is permissible only if the cylinder is disconnected
and removed from the heater. • Check the tightness of the gas valve and for damage. If you suspect a dama-
ge, have it changed by your gas dealer. • Never store liquid gas cylinder in a sub-terrain, or at places without adequate
air ventilation.
der enclosure, control compartment, burner and circulation air passageways of the heater with heavy duty pipe cleaner or compressed air to keep appli- ance clean and safe for use. • Never clear ports or other openings with toothpicks or other article that will
break and block the ports. • If carbon deposits develop, remove the reflector and flame screen and clean
heater is not in use. Wait until the heater is cool before covering. 4


quickly than normal. Check frequently for corroded areas and repair them promptly.
Review these tips first and you may not need to call for service.
Gas valve may be OFF Turn the gas valve ON.
Air in supply system Purge air from lines by pres- sing the control knob until you smell gas.
Low gas pressure Replace cylinder with a new cylinder.
Lack of fuel pressure Keep the variable knob depressed for 10-20 seconds or more after the pilot light ignited. Tank near empty. Refill gas tank.

Burner flame goes off immediately after ignition
Low gas pressure Let the pilot flame stay lit for 10 minutes before set- ting variable knob to LO.
Blockage in burner injector
Clean or replace burner injector
Base is not on a leveI surface
Place heater on a IeveI surface
Low gas pressure Replace cylinder with a new cylinder.
Thick black smoke Blockage in burner Turn off the heater and Iet it cool. Remove blockage and clear burnerinside and outside.
Carbon bulld-up Dirt or film on reflec- tor and flame screen
Clean reflector and flame screen.
If it is decided that the gas heater is not to be used any more, it is recom-
mended that it be disconnected from the gas container. Also cut the rubber hose. If children play with the heater, make sure that dangerous parts are removed. Never dispose of non-biodegradable products in the environment, but dis-
pose of them in accordance with current national legislation. At the end of its lifetime, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection center or to a dealer providing this service. Disposing of a household appliance separately avoids possible negative con-
sequences for the environment and health deriving from inappropriate dis- posal and enables the constituent materials to be recovered in order to make significant savings in energy and resources. As a reminder of the need to dis- pose of household appliances separately.
The appliance is supplied with a 24-month guarantee, commencing on the
date of purchase. All material and manufacturing defects will be repaired or replaced free of charge within this period. The following rules apply:
1. We expressly refuse all further damage claims, including claims for collate- ral and/or consequential damage. 2. Repairs to or replacement of components within the guarantee period will not result in an extension of the guarantee. 3. The guarantee is invalidated if any modifications have been made, non- genuine parts are fitted or repairs are carried out by third parties. 4. Components subject to normal wear, such as filters, batteries, lamps and heating elements are not covered by the guarantee. 5. The guarantee is valid only when you present the original, dated purchase invoice and if no modifications have been made to it. 6. The guarantee is invalid for damage caused by neglect and/or by actions that deviate from those in this instruction booklet. 4
Emitter glows une- ven

To prevent unnecessary expense, we recommend that you always first care- fully consult the instructions for use. Take the appliance to your dealer for repairs if these instructions do not provide a solution.
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| Pilot will not light | Gas valve may be OFF | Turn the gas valve ON. | p.12 |
| Pilot will not light | Tank fuel empty | Refill gas tank. | p.12 |
| Pilot will not light | Pilot injector blocked | Clean or replace pilot injec- tor. | p.12 |
| Pilot will not light | Air in supply system | Purge air from lines by pres- sing the control knob until you smell gas. | p.12 |
| Pilot will not light | Loose connections | Check all fittings. | p.12 |
| Pilot will not light | Low gas pressure | Replace cylinder with a new cylinder. | p.12 |
| Pilot will not stay on | Lack of fuel pressure | Keep the variable knob depressed for 10-20 seconds or more after the pilot light ignited. Tank near empty. Refill gas tank. | p.12 |
| Pilot will not stay on | Debris around pilot | Clean dirty area. | p.12 |
| Pilot will not stay on | Loose connections | Tighten connections. | p.12 |
| Pilot will not stay on | Thermocouple bad | Replace thermocouple. | p.12 |
| Pilot will not stay on | Gas Ieak in Iine | Check connections. | p.12 |
| Burner will not light | Pressure is low | Tank near empty.Refill gas tank. | p.12 |
| Burner will not light | Opening blocked | Remove and clean. | p.12 |
| Burner will not light | ControI is not 0N | Turn valve to ON. | p.12 |
| Burner will not light | Thermocouple bad | Replace thermocouple. | p.12 |
| Burner will not light | Pilot light assembly bent | Place pilot properly. | p.12 |
| Burner will not light | Not in correct location | Position properly and retry. | p.12 |
| Burner flame is low | Supply hose is bent or twisted | Straighten hose and per- form leak teston hose. | p.12 |
| Burner flame is low | Blockage in burner injector | Clean or replace burner injector. | p.12 |
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.