Congratulations on the purchase of your Qlima air conditioner. You have acquired a high
quality product that, if used responsibly, will give you many years of pleasure.
Please read these instructions for use first in order to ensure the maximum life span of your
air conditioner.
On behalf of the manufacturer, we provide a 24-month guarantee on all material and
production defects and a 48-month guarantee on the compressor of the air conditioner.
Please enjoy your air conditioner.
PVG Holding b.v.


Dear Sir, Madam, · Yours sincerely, · Customer service department


the amount, please refer to the relevant label on the unit itself.
months.

S-models connecting pipe not included)



when anti-cold air feature is turned on (cooling & heating units)
when ECO function(some units) is activated, the illuminates gradually one by one as -- -- --
In other modes, the unit will display your temperature setting.
In Fan and Dry mode, the unit will display the room temperature.
Cooling, heating and / or dehumidifying are effective at the following indoor and outdoor temperatures:

Room temperature 17ºC - 32ºC 0ºC - 30ºC 10ºC - 32ºC
Outdoor temperature -25ºC - 50ºC -25ºC - 30ºC 0ºC - 50ºC

come into operation and cause the unit to function abnormally.
of the air conditioner may attract condensation. Please set the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH fan mode.



a On/off Button: Push this button to start the unit operation. Push the button again to stop the unit
operation.
b Mode Button: Each time you press the button, a mode is selected in a sequence that goes from AUTO
COOL DRY HEAT and FAN only as the following figure indicates:
c + Button: Push the button to increase the indoor temperature setting to 30ºC.
d - Button: Push the button to decrease the indoor temperature setting to 17ºC.
e Fan Button: This button is used for selecting Fan Speed. Each time you press the button, a fan speed is
selected in a sequence that goes from AUTO, LOW, MED to HIGH, then back to Auto. When you select the
AUTO or DRY mode, the fan speed will be automatically controlled and you can not set the fan speed.
f SLEEP Button: Press this button to go into the Energy-Saving operation mode. Press it again to cancel.
This function can only be used on COOL, HEAT and AUTO mode and maintain the most comfortable
temperature for you. The unit automatically increases the set temperature by 1ºC per hour (in cooling
mode) or decreases the set temperature by 1ºC per hour (heating mode) during the first 2 hours. The air
conditioner will maintain this temperature (set temperature – or + 2 degrees) during the next 5 hours.
After this period, the air conditioner will shut itself down.

g Swing Button: Press the SWING button to activate the swing feature. Push the button again to stop.
h Air direction Button: Press this button to change the swing angle of the louver. The swing angle of the
louver is 6o for each press. When the louver swings at a certain angle which would affect the cooling and
heating effect of the air conditioner, it would automatically change the swing direction. No symbol will
appear in the display area when press this button.
again to stop.
auto-timed setting in 30 minutes increments. When the setting time displays 10Hr, each press will increase
the auto-timed setting 60 minutes increments. To cancel the auto-timed program, continue pressing the
button until 0.0 is displayed.
auto-timed setting in 30 minutes increments. When the setting time displays 10Hr, each press will increase
the auto-timed setting 60 minutes increments. To cancel the auto-timed program, continue pressing the
button until 0.0 is displayed.
k RESET Button: When you press the recessed RESET button, all current settings are cancelled and the con-
trol will return to the initial settings.
l Turbo Button / Active Clean button: Push this button on COOL mode, the air conditioner goes into
powerful cooling operation. Push again to cancel the TURBO function. Upon pressing this button (> 2
sec) the unit will go into the Active Clean mode. A complete process will be started to clean the internal
side of the evaporator and to reduce the breeding of bacteria. When this function is activated all timer
settings will be cancelled. To stop the Active Clean mode press the button (> 2 sec) again.
m LOCK Button: When you press the recessed LOCK button, all current settings are locked in and the remote
controller does not accept any operation except that of the LOCK. Press again to cancel the LOCK mode.
n LED DISPLAY / FOLLOW ME Button: Press this button to clear the digit display in the air conditioner. The
digit display in the air conditioner will reactivate itself automatically after 3 seconds, when no buttons are
being pressed in this period. Press it again to activate it (Not applicable to units without this function).
When pushing more than 2 seconds, the FOLLOW ME function will be activated, pushing more than 2
seconds again to disable.
o Low sound button / indoor freezing prevention: Press this button to decrease the indoor sound pres-
sure level to 21 dB(A). The indoor unit fan speed is reduced to its lowest level. Upon pressing this button
(> 2 seconds) the unit will go into the freezing prevention mode. The unit will overrule the indoor tem-
perature setting and will set it to approx 8 °C. In this way preventing your home from freezing during
cold periods at the lowest possible energy consumption. When this mode is selected the indoor unit
display will show “FP”. This button can only be operated in heating mode. To leave the Home Freezing
Prevention Mode: simply press the button once again.


the indoor unit.
applicable to cooling only models), Fan .
mode to FAN, no temperature setting is displayed. And if in the TIMER mode, shows the ON and OFF
settings of the TIMER.
d Fan speed display: Displays the selected fan speed, AUTO (no display), LOW , MED and HIGH . The
fan speed is AUTO when the operating mode is either AUTO or DRY.
e ON / OFF display: Displayed by pressing the ON / OFF button. Press the ON / OFF button again to remove.
f Lock display: Displayed when LOCK mode is activated.
g Sleep display: Displayed under sleeping operation. Press the SLEEP button again to remove.
Install / Replace Batteries
Use two dry alkaline batteries (AAA/LR03).
Do not use rechargeable batteries.
direction shown on the cover.
When the air conditioner is ready for use (check if unit is plugged in and whether electrical power is availa-
ble), switch on the power and the OPERATION indicator lamp on the display panel of the indoor unit starts
flashing.
indoor unit lights. The FAN SPEED is automatically controlled.

HEAT (HEAT PUMP units only), or FAN ONLY modes by pressing button b.
settings. Push the On/off button a again to stop this unit operation. G
mode. Push the On/off button a again to stop this unit operation. G
Push Timer on/off button (i and j) to set the on and off times of the unit. The effective operation time set
by the remote controller for the timer function is limited to a period of between 0.5 and less than 24 hours.
1.1 Push the Timer on button i, then the remote controller display shows ON TIMER, the last set time for
the starting operation and the signal “h” will be shown on the Timer display area. You are now ready
to reset the time to START the operation.
1.2 Push the Timer on button i again to set desired unit start time.
1.3 After setting the Timer on,there will be half a second delay before the remote controller transmits the
signal to the air conditioner.
2.1 Push the Timer off button j and the remote controller display will show OFF TIMER and the last set
time for the timer off operation in hours will be shown on the Timer display area. You are now ready
to reset the time of the STOP operation.
2.2 Push the Timer off button j again to set the time you want to stop the operation.
2.3 After setting the Timer off, there will be half a second delay before the remote controller transmits the
signal to the air conditioner.

TIMER ON
To start the air conditioner in 6 hours.
signal “h” will show on the display area.
The “TIMER ON” indicator remains on and this function is activated.
TIMER ON OFF
(setting both ON and OFF timers simultaneously)
(On --> Stop --> Start operation)
This feature is useful when you want to stop the air conditioner after you go to bed, On
and start it again in the morning when you wake up or when you return home.
Example:
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.

How to operate your unit without the remote control.
In the event that your remote control fails to work, your unit can be operated manually with the MANUAL
CONTROL button located on the indoor unit. Note that manual operation is not a long-term solution, and
that operating the unit with your remote control is strongly recommended.
BEFORE MANUAL OPERATION Unit must be turned off before manual operation.
To operate your unit manually:
To achieve optimal performance, please note the following:
perature levels.
reduced and the air conditioner may stop running. Make sure there are no obstacles blocking the air
flow. The air stream must be allowed to reach the entire room unhindered. Also the air stream must
be allowed to reach the air conditioner unhindered.
advised to clean the filters every two weeks.
Manual · control button · Manual control button


or cause uneven room temperatures.
Adjusting the horizontal Air Flow Direction (up - down)

The air conditioner automatically adjusts the horizontal air flow direction in accord-
ance with the operating mode.
To set the horizontal air flow direction
Perform this function while the unit is in operation. Keep pressing the AIR DIRECTION
button h on the remote controller to move the louver to the desired direction.
direction to which you adjusted the louver by pressing the AIR DIRECTION
button.
To set the vertical air flow direction (left - right)
Adjust the vertical louver manually using the lever in the middle of the vertical
louver arm (depending on model). When the air conditioner is in operation and the
vertical louver is in a specific position, move the lever at left (or right, depending
on model) end of the air outlet to the desired position.
Take care, do not touch the fan behind the vertical louvers!
To automatically swing the air flow direction (up - down)
Perform this function while the air conditioner is in operation.
desired position.
Range · Deflector rod

controller), it will automatically select COOLING, HEATING or FAN only
1 hour 1 hour
operation depending on what temperature you have selected and the room
temperature.
temperature point set by you.
1 hour 1 hour
ually.
Cooling Fan only Cooling Fan only Cooling
ation, the air conditioner will automatically increase (cooling) or decrease
(heating) 1ºC per hour. The set temperature will be steady 2 hours later and
remains steady for 5 hours. After 5 hours the unit will stop. The fan speed
will be automatically controlled.
between the set temperature and the actual room temperature.
operation or fan only. The fan speed is controlled automatically.
When the air conditioner is dehumidifying it is likely that the room temperature will decrease.
It is therefore normal that a hygrostat will measure a higher relative humidity. The absolute
humidity in the room will however be lowered, depending on the amount of moisture produced
in the room (cooking, people etc).

hold Drain Cleaner No
A clogged air filter reduces the cooling efficiency of this unit. Clean the filter once every 2
weeks.
Remove air freshening filter from back of larger filter (some units)
unpleasant odours anymore once dirty. At that moment this filter needs to be
replaced by a new filter. (available at your dealer). It is advised to exchange this filter
twice every season.
once dirty. When dirty this filter cannot be cleaned and needs to be replaced by a
new filter (available at your dealer). It is advised to exchange this filter twice every
season.
Recommended change of filter
the screen filter, the screen filter can be replaced into the air conditioner.
right edges line up correctly and place filter into position.

If you plan to idle the unit for a long time, perform the following:
Remove the batteries from the remote controller.
ized airconditioning engineer.
The following events may occur during normal operation.
of the following three situations and the set temperature has not been reached.
A. When heating has just started.
B. Defrosting.
C. Low temperature heating.
humidity is high resulting in lower heating efficiency of the air conditioner.
automatically.
amount of frost buildup on the outdoor unit.
COOL mode in an indoor environment that has a high relative humidity.
tioner restarts in HEAT mode operation after defrosting.
Compressor protection · Anti-cold air · Defrosting

sound is the sound of the refrigerant flowing or coming to a stop.
ning. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the
temperature is changing.
use of the unit.
or smoke.
stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again
when the indoor temperature rises on COOL mode or falls on HEAT mode to the set point.
humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air out-
let position and select HIGH fan speed.
ing heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner
decreases accordingly and the heating capacity will decrease. At the same time, heat loading of the
air conditioner increases due to larger difference between indoor and outdoor temperature. If a com-
fortable temperature cannot be achieved by the air conditioner, it is advised to use a supplementary
heating device.
The air conditioner is equipped with Auto-restart feature, when the power restores, the unit restarts
automatically with all the previous settings preserved by the memory function.
When the outdoor unit detects a shortage of refrigerant, the air conditioner will stop and the indoor
unit shows the alarm EC on the display.
When this alarm occurs, do not restart the air conditioner and contact your supplier.

The Unit has a 3-minute protection feature that prevents the unit from over- loading. The unit cannot be restarted within three minutes of being turned off.
Unit does not turn on when pressing ON/OFF button
The unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previ- ously selected mode again.
The unit changes from COOL/ HEAT mode to FAN mode
The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctu- ates again.
The indoor unit emits white mist In humid regions, a large temperature difference between the room’s air
and the conditioned air can cause white mist.
Both the indoor and outdoor units emit white mist
When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.
A rushing air sound may occur when the louver resets its position.
The indoor unit makes noises
A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.
Low hissing sound during operation: This is normal and is caused by refrige- rant gas flowing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.
Both the indoor unit and out- door unit make noises
Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.
The outdoor unit makes noises The unit will make different sounds based on its current operating mode.
Dust is emitted from either the indoor or outdoor unit
The unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by cove- ring the unit during long periods of inactivity.
The unit may absorb odors from the environment (such as furniture, cook- ing, cigarettes, etc.) which will be emitted during operations.
The unit emits a bad odor
The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operate During operation, the fan speed is controlled to optimize product operation.
Operation is erratic, unpredicta- ble, or unit is unresponsive
Issue Possible Causes


Temperature setting may be higher than ambient room temperature Lower the temperature setting
The heat exchanger on the indoor or out- door unit is dirty Clean the affected heat exchanger
The air filter is dirty Remove the filter and clean it according to instructions
The air inlet or outlet of either unit is blocked
Turn the unit off, remove the obstruction and turn it back on
Doors and windows are open Make sure that all doors and windows are closed while operating the unit
Excessive heat is generated by sunlight Close windows and curtains during peri- ods of high heat or bright sunshine
Too many sources of heat in the room (people, computers, electronics, etc.) Reduce amount of heat sources
Low refrigerant due to leak or long-term use
Check for leaks, re-seal if necessary and top off refrigerant
SILENCE function can lower product per- formance by reducing operating frequen- cy. Turn off SILENCE function.
SILENCE function is activated(optional function)
Power failure Wait for the power to be restored
The power is turned off Turn on the power
The fuse is burned out Replace the fuse
The unit is not working
Remote control batteries are dead Replace batteries
The Unit’s 3-minute protection has been activated
Wait three minutes after restarting the unit
Timer is activated Turn timer off
There’s too much or too little refrigerant in the system
Check for leaks and recharge the system with refrigerant.
Incompressible gas or moisture has ente- red the system.
Evacuate and recharge the system with refrigerant
The unit starts and stops frequently
The compressor is broken Replace the compressor
The voltage is too high or too low Install a manostat to regulate the voltage
The outdoor temperature is exetremtly low Use auxiliary heating device
Cold air is entering through doors and windows
Make sure that all doors and windows are closed during use
Low refrigerant due to leak or long-term use
Check for leaks, re-seal if necessary and top off refrigerant
Indicator lamps continue flashing The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the power and contact your nearest customer ser- vice center.
Problem Cause Solution · Poor Cooling Performance · Poor heating performance

If the trouble has not been corrected, please contact your supplier. Be sure to inform them of the detailed
malfunctions and unit model.
The air conditioner is supplied with a 48-month guarantee on the compressor and a 24-month guarantee on
other components, commencing on the date of purchase. The following rules apply:
the guarantee.
repairs are carried out by third parties.
tions have been made.
instruction booklet.
ditioner components shall always be for the account of the purchaser.
nection of the units by not qualified personnel is not covered by the guarantee conditions applicable to
this product. Damage to units which are mounted, connected and/or disconnected not following local
law and/or legislation and/or not following the guidelines in this manual is not covered by the guaran-
tee conditions applicable to this product.
Consult your dealer for repairs if these instructions do not provide a solution. Make sure that in the unlikely
case of needed disconnection, that disconnection is always done by qualified, authorized personnel and
according to your local laws and legislation.

S 4225 S 5225 S 5225 B S-JA 2519
SC 4248 SC 5248 SCJA-4819
S 4232 S 5232
S 4248 S 5248
SC 4232 SC 5232
Type air-conditioner Wall mounted split Wall mounted split Wall mounted split Wall mounted split Wall mounted split Wall mounted split
Cooling capacity nominal (min- max) * W 2600 (1030 - 3190) 3500 (820 - 4160) 5300 (1730 - 6980) 2500 (1590 - 3000) 3200 (2110 - 4000) 4600 (1820 - 6120)
EE Class cooling * A++
Heating capacity nominal (min- max) * W 2500 ( 880 - 3660) 2700 ( 850 - 4780) 3900 (1060 - 6980) 2400 (960 - 4890) 2400 (1280 - 4900) 3800 (1380 - 6740)
EE Class heating * A+
Dehumidifying capacity (at 32°C/80%) ** / *** L / 24 h 24.0 28.8 43.2 26.4 31.2 36.0
Power consumption cooling kW 0.70 1.09 1.54 0.71 1.19 1.40
Power consumption heating kW 0.67 1.05 1.46 0.84 1.23 1.90
Annual energy consumption * kWh 128 / 875 175 / 922 290 / 1365 137 / 836 187 / 834 245 / 1326
Power supply V / Hz / Ph 220-240~ / 50 / 1 220-240~ / 50 / 1 220-240~ / 50 / 1 220-240~ / 50 / 1 220-240~ / 50 / 1 220-240~ / 50 / 1
Max. Current A 9.5 10.0 11.5 10.0 10.0 13.0
Air flow ** m3/h 416/309/230 539/478/294 750/505/420 545/435/368 545/435/368 770/610/410
For rooms up to** m3 60-85 80-100 140-185 60-85 80-100 125-145
Suited for regions W / A / C W/A/C
Compressor type Rotary
Fan speeds 4 4 4 3 3 3
Thermostatic range oC 17 - 30 17 - 30 17 - 30 17 - 30 17 - 30 17 - 30
Controls manual / mechanic / electronic Electronic remote Electronic remote Electronic remote Electronic remote Electronic remote Electronic remote
Remote control Yes / No Y
Air filter type(s) Screen. Active carbon.
3M HAF Screen. Active carbon.
3M HAF Screen. Active carbon.
3M HAF Screen. Active carbon.
3M HAF Screen. Active carbon.
3M HAF Screen. Active carbon.
Refrigerant type / charge R / g R32 / 700 R32 / 800 R32 / 1250 R32 / 800 R32 / 800 R32 / 1190
Refrigerant GWP 675
CO2 equivalent tonnes 0.473 0.540 0.844 0.540 0.540 0.803
Dimensions indoor unit (w x h x d) mm 722x187x290 802x189x297 965x215x319 805x194x285 805x194x285 957x213x302
Dimensions outdoor unit (w x h x d) mm 770x300x555 770x300x555 800x333x554 770x300x555 770x300x555 800x333x554
Net weight indoor unit kg 7.3 8.2 10.8 7.8 7.8 10.3
Net weight outdoor unit kg 27.2 27.0 37.0 25.7 25.7 34.6
Gross weight indoor unit kg 9.7 10.7 14.1 10.4 10.4 13.8
Gross weight outdoor unit kg 29.7 29.4 39.9 31.1 31.1 40.2
Sound pressure level indoor unit **** dB(A) 54 56 58 53 53 55
Sound pressure level outdoor unit **** dB(A) 59 60 64 62 62 62
Sound pressure level indoor unit (low) **** dB 20 21 21 25 25 29
Unit protection indoor IP IPX0
Unit protection outdoor IP IPX4
** To be used as indication
*** Moisture removal at 32°C, 80% RH
Model

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps, hazardous substanc-
es can leak into the groundwater and get into the food chain, damaging your health and
well-being. When replacing old appliances with new once, the retailer is legally obligated to
take back your old appliance for disposal at least for free of charge. Do not throw batteries
into the fire, where they can explode or release dangerous liquids. If you replace or destroy
the remote control, remove the batteries and throw them away in accordance with the
applicable regulations because they are harmful to the environment.
Protocol. It should only be serviced or dismantled by professional trained personnel.
This equipment contains R32 refrigerant in the amount as stated in the table above. Do not vent R32 into
Internet:
For your convenience you can download the latest version of the user-, installation- and/or service manual


Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| Unit does not turn on when pressing ON/OFF button | The Unit has a 3-minute protection feature that prevents the unit from over- loading. The unit cannot be restarted within three minutes of being turned off. | p.19 | |
| The unit changes from COOL/ HEAT mode to FAN mode | The unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previ- ously selected mode again. | p.19 | |
| The unit changes from COOL/ HEAT mode to FAN mode | The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctu- ates again. | p.19 | |
| The indoor unit emits white mist | In humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist. | p.19 | |
| Both the indoor and outdoor units emit white mist | When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process. | p.19 | |
| The indoor unit makes noises | A rushing air sound may occur when the louver resets its position. | p.19 | |
| The indoor unit makes noises | A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts. | p.19 | |
| Both the indoor unit and out- door unit make noises | Low hissing sound during operation: This is normal and is caused by refrige- rant gas flowing through both indoor and outdoor units. | p.19 | |
| Both the indoor unit and out- door unit make noises | Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction. | p.19 | |
| Both the indoor unit and out- door unit make noises | Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises. | p.19 | |
| The outdoor unit makes noises | The unit will make different sounds based on its current operating mode. | p.19 | |
| Dust is emitted from either the indoor or outdoor unit | The unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by cove- ring the unit during long periods of inactivity. | p.19 | |
| The unit emits a bad odor | The unit may absorb odors from the environment (such as furniture, cook- ing, cigarettes, etc.) which will be emitted during operations. | p.19 | |
| The unit emits a bad odor | The unit’s filters have become moldy and should be cleaned. | p.19 | |
| The fan of the outdoor unit does not operate | During operation, the fan speed is controlled to optimize product operation. | p.19 | |
| Operation is erratic, unpredicta- ble, or unit is unresponsive | Interference from cell phone towers and remote boosters may cause the unit to malfunction. In this case, try the following: • Disconnect the power, then reconnect. • Press ON/OFF button on remote control to restart operation. | p.19 | |
| Poor Cooling Performance | Temperature setting may be higher than ambient room temperature | Lower the temperature setting | p.20 |
| Poor Cooling Performance | The heat exchanger on the indoor or out- door unit is dirty | Clean the affected heat exchanger | p.20 |
| Poor Cooling Performance | The air filter is dirty | Remove the filter and clean it according to instructions | p.20 |
| Poor Cooling Performance | The air inlet or outlet of either unit is blocked | Turn the unit off, remove the obstruction and turn it back on | p.20 |
| Poor Cooling Performance | Doors and windows are open | Make sure that all doors and windows are closed while operating the unit | p.20 |
| Poor Cooling Performance | Excessive heat is generated by sunlight | Close windows and curtains during peri- ods of high heat or bright sunshine | p.20 |
| Poor Cooling Performance | Too many sources of heat in the room (people, computers, electronics, etc.) | Reduce amount of heat sources | p.20 |
| Poor Cooling Performance | Low refrigerant due to leak or long-term use | Check for leaks, re-seal if necessary and top off refrigerant | p.20 |
| Poor Cooling Performance | SILENCE function is activated(optional function) | SILENCE function can lower product per- formance by reducing operating frequen- cy. Turn off SILENCE function. | p.20 |
| The unit is not working | Power failure | Wait for the power to be restored | p.20 |
| The unit is not working | The power is turned off | Turn on the power | p.20 |
| The unit is not working | The fuse is burned out | Replace the fuse | p.20 |
| The unit is not working | Remote control batteries are dead | Replace batteries | p.20 |
| The unit is not working | The Unit’s 3-minute protection has been activated | Wait three minutes after restarting the unit | p.20 |
| The unit is not working | Timer is activated | Turn timer off | p.20 |
| The unit starts and stops frequently | There’s too much or too little refrigerant in the system | Check for leaks and recharge the system with refrigerant. | p.20 |
| The unit starts and stops frequently | Incompressible gas or moisture has ente- red the system. | Evacuate and recharge the system with refrigerant | p.20 |
| The unit starts and stops frequently | The compressor is broken | Replace the compressor | p.20 |
| The unit starts and stops frequently | The voltage is too high or too low | Install a manostat to regulate the voltage | p.20 |
| Poor heating performance | The outdoor temperature is exetremtly low | Use auxiliary heating device | p.20 |
| Poor heating performance | Cold air is entering through doors and windows | Make sure that all doors and windows are closed during use | p.20 |
| Poor heating performance | Low refrigerant due to leak or long-term use | Check for leaks, re-seal if necessary and top off refrigerant | p.20 |
| Indicator lamps continue flashing | The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the power and contact your nearest customer ser- vice center. | p.20 | |
| Error code appears in the window display of indoor unit: • E0, E1, E2… • P1, P2, P3… • F1, F2, F3… | p.20 |