CONTENTSp.2A SAFETY INSTRUCTIONSp.2B. PARTS NAMESp.2C. OPERATING TEMPERATUREp.2D. OPERATION WITH REMOTE CONTROLp.2E. MANUAL OPERATION (WITHOUT REMOTE)p.2F. OPTIMAL OPERATIONp.2G. ADJUSTING AIR FLOW DIRECTIONp.2H. HOW THE AIR CONDITIONER WORKSp.2I. MAINTENANCEp.2J. OPERATION TIPSp.2K. TROUBLE SHOOTING TIPSp.2L. GUARANTEE CONDITIONSp.2M. TECHNICAL DATAp.2READ THIS MANUALp.2Note about Fluorinated Gassesp.6B PART NAMESp.6C OPERATING TEMPERATUREp.7D OPERATION WITH REMOTE CONTROLp.8Introduction of Function Buttons on the Remote Controllerp.8AUTO COOL DRY HEAT FANp.8Names and Functions of indicators on Remote Controllerp.9Operating the Remote Controllerp.10Install / Replace Batteriesp.103. Reattach the cover by sliding it back into position. Gp.10AUTOMATIC Operationp.10COOL, HEAT, and FAN ONLY Operationp.11DRY Operationp.11TIMER Operationp.11Example of timer settingp.12TIMER ONp.12Combined timerp.12TIMER ON OFFp.12TIMER OFF --> TIMER ONp.12indicator remains on and this function is activated. Gp.12E MANUAL OPERATION (WITHOUT REMOTE)p.13F OPTIMAL OPERATIONp.13G ADJUSTING AIR FLOW DIRECTIONp.14CAUTION!p.14H HOW THE AIR CONDITIONER WORKSp.15COOLINGp.15HEATINGp.15SLEEP/ECONOMIC OPERATIONp.15DEHUMIDIFYINGp.15DEHUMIDIFYING OPERATIONp.15NOTEp.15I MAINTENANCEp.16Cleaning the indoor unit and remote controllerp.16Cleaning the filterp.16Maintenancep.17Checks before operationp.17J OPERATION TIPSp.17K TROUBLE SHOOTING TIPSp.19Malfunctions and Solutionsp.19L GUARANTEE CONDITIONSp.21M TECHNICAL DATAp.22SC 4225 SC 5225 SCJA-2519p.22SC 4248 SC 5248 SCJA-4819p.22S 4232 S 5232p.22S 4248 S 5248p.22SC 4232 SC 5232p.22SEER* 7.1 7.0 6.4 6.5 6.2 6.7p.22SCOP* 4.0 4.1 4.0 4.0 4.0 4.0p.223M HAFp.22* EN 14511 / EN14825p.22**** EN12102-2008p.22
Page 1 of the Qlima SC 4232 user manual
Pagina 1 · klik om te vergroten
Pagina 1

Congratulations on the purchase of your Qlima air conditioner. You have acquired a high

quality product that, if used responsibly, will give you many years of pleasure.

Please read these instructions for use first in order to ensure the maximum life span of your

air conditioner.

On behalf of the manufacturer, we provide a 24-month guarantee on all material and

production defects and a 48-month guarantee on the compressor of the air conditioner.

Please enjoy your air conditioner.

PVG Holding b.v.

Qlima SC 4232 diagram (page 1)
Afb. 1
1. READ THE DIRECTIONS FOR USE FIRST.
Qlima SC 4232 diagram (page 1)
Afb. 2
2. IN CASE OF ANY DOUBT, CONTACT YOUR DEALER.

Dear Sir, Madam, · Yours sincerely, · Customer service department

Page 2 of the Qlima SC 4232 user manual — Inhoudsopgave
Pagina 2 · Inhoud
Inhoud

Inhoud

CONTENTSp.2A SAFETY INSTRUCTIONSp.2B. PARTS NAMESp.2C. OPERATING TEMPERATUREp.2D. OPERATION WITH REMOTE CONTROLp.2E. MANUAL OPERATION (WITHOUT REMOTE)p.2F. OPTIMAL OPERATIONp.2G. ADJUSTING AIR FLOW DIRECTIONp.2H. HOW THE AIR CONDITIONER WORKSp.2I. MAINTENANCEp.2J. OPERATION TIPSp.2K. TROUBLE SHOOTING TIPSp.2L. GUARANTEE CONDITIONSp.2M. TECHNICAL DATAp.2READ THIS MANUALp.2Note about Fluorinated Gassesp.6B PART NAMESp.6C OPERATING TEMPERATUREp.7D OPERATION WITH REMOTE CONTROLp.8Introduction of Function Buttons on the Remote Controllerp.8AUTO COOL DRY HEAT FANp.8Names and Functions of indicators on Remote Controllerp.9Operating the Remote Controllerp.10Install / Replace Batteriesp.103. Reattach the cover by sliding it back into position. Gp.10AUTOMATIC Operationp.10COOL, HEAT, and FAN ONLY Operationp.11DRY Operationp.11TIMER Operationp.11Example of timer settingp.12TIMER ONp.12Combined timerp.12TIMER ON OFFp.12TIMER OFF --> TIMER ONp.12indicator remains on and this function is activated. Gp.12E MANUAL OPERATION (WITHOUT REMOTE)p.13F OPTIMAL OPERATIONp.13G ADJUSTING AIR FLOW DIRECTIONp.14CAUTION!p.14H HOW THE AIR CONDITIONER WORKSp.15COOLINGp.15HEATINGp.15SLEEP/ECONOMIC OPERATIONp.15DEHUMIDIFYINGp.15DEHUMIDIFYING OPERATIONp.15NOTEp.15I MAINTENANCEp.16Cleaning the indoor unit and remote controllerp.16Cleaning the filterp.16Maintenancep.17Checks before operationp.17J OPERATION TIPSp.17K TROUBLE SHOOTING TIPSp.19Malfunctions and Solutionsp.19L GUARANTEE CONDITIONSp.21M TECHNICAL DATAp.22SC 4225 SC 5225 SCJA-2519p.22SC 4248 SC 5248 SCJA-4819p.22S 4232 S 5232p.22S 4248 S 5248p.22SC 4232 SC 5232p.22SEER* 7.1 7.0 6.4 6.5 6.2 6.7p.22SCOP* 4.0 4.1 4.0 4.0 4.0 4.0p.223M HAFp.22* EN 14511 / EN14825p.22**** EN12102-2008p.22
Page 6 of the Qlima SC 4232 user manual — B PART NAMES
Pagina 6 · klik om te vergroten
Pagina 6

Note about Fluorinated Gasses

1. This air-conditioning unit contains fluorinated gasses. For specific information on the type of gas and

the amount, please refer to the relevant label on the unit itself.

2. Installation, service, maintenance and repair of this unit must be performed by a certified technician.
3. Product uninstallation and recycling must be performed by a certified technician.
4. If the system has a leak-detection system installed, it must be checked for leaks at least every 12

months.

5. When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
6. This air-conditioning unit is a hermetically sealed unit that contains fluorinated gasses.

B PART NAMES

Qlima SC 4232 — B PART NAMES diagram (page 6)
Afb. 3

S-models connecting pipe not included)

Qlima SC 4232 — B PART NAMES diagram (page 6)
Afb. 4
Page 7 of the Qlima SC 4232 user manual — C OPERATING TEMPERATURE
Pagina 7 · klik om te vergroten
Pagina 7
Qlima SC 4232 — C OPERATING TEMPERATURE diagram (page 7)
Afb. 5
  • FRESH, SWING, TURBO, or SILENCE features are turned on
  • FRESH, SWING, TURBO, or SILENCE features are turned off

when anti-cold air feature is turned on (cooling & heating units)

when ECO function(some units) is activated, the illuminates gradually one by one as -- -- --

In other modes, the unit will display your temperature setting.

In Fan and Dry mode, the unit will display the room temperature.

C OPERATING TEMPERATURE

Cooling, heating and / or dehumidifying are effective at the following indoor and outdoor temperatures:

Qlima SC 4232 — C OPERATING TEMPERATURE diagram (page 7)
Afb. 6

Room temperature 17ºC - 32ºC 0ºC - 30ºC 10ºC - 32ºC

Outdoor temperature -25ºC - 50ºC -25ºC - 30ºC 0ºC - 50ºC

Qlima SC 4232 — C OPERATING TEMPERATURE diagram (page 7)
Afb. 7
  • If air conditioner is used outside of the above conditions, certain safety protection features may

come into operation and cause the unit to function abnormally.

  • If the air conditioner operates in excess of a relative humidity of 80% in the room, the surface

of the air conditioner may attract condensation. Please set the vertical air flow louver to its

maximum angle (vertically to the floor), and set HIGH fan mode.

  • For maximum effect of your air conditioner always close doors and windows when cooling or
Page 8 of the Qlima SC 4232 user manual — AUTO COOL DRY HEAT FAN
Pagina 8 · klik om te vergroten
Pagina 8

D OPERATION WITH REMOTE CONTROL

  • NOTE!
  • Always aim the remote controller towards the receiver on the indoor unit and make sure there are no obstacles in between the remote control and the receiver on the indoor unit. Otherwise the remote control signal will not be picked up by the receiver and the air conditioner will not work properly.
  • The maximum distance at which the remote control will work is approximately 6 to 7 meters.

Introduction of Function Buttons on the Remote Controller

Qlima SC 4232 — Introduction of Function Buttons on the Remote Controller diagram (page 8)
Afb. 8 · Introduction of Function Buttons on the Remote Contr…
Qlima SC 4232 — Introduction of Function Buttons on the Remote Controller diagram (page 8)
Afb. 9 · Introduction of Function Buttons on the Remote Contr…

a On/off Button: Push this button to start the unit operation. Push the button again to stop the unit

operation.

b Mode Button: Each time you press the button, a mode is selected in a sequence that goes from AUTO

COOL DRY HEAT and FAN only as the following figure indicates:

AUTO COOL DRY HEAT FAN

c + Button: Push the button to increase the indoor temperature setting to 30ºC.

d - Button: Push the button to decrease the indoor temperature setting to 17ºC.

e Fan Button: This button is used for selecting Fan Speed. Each time you press the button, a fan speed is

selected in a sequence that goes from AUTO, LOW, MED to HIGH, then back to Auto. When you select the

AUTO or DRY mode, the fan speed will be automatically controlled and you can not set the fan speed.

f SLEEP Button: Press this button to go into the Energy-Saving operation mode. Press it again to cancel.

This function can only be used on COOL, HEAT and AUTO mode and maintain the most comfortable

temperature for you. The unit automatically increases the set temperature by 1ºC per hour (in cooling

mode) or decreases the set temperature by 1ºC per hour (heating mode) during the first 2 hours. The air

conditioner will maintain this temperature (set temperature – or + 2 degrees) during the next 5 hours.

After this period, the air conditioner will shut itself down.

FRESH ButtonLong press to active the FRESH function
Page 9 of the Qlima SC 4232 user manual — Names and Functions of indicators on Remote Controller
Pagina 9 · klik om te vergroten
Pagina 9

g Swing Button: Press the SWING button to activate the swing feature. Push the button again to stop.

h Air direction Button: Press this button to change the swing angle of the louver. The swing angle of the

louver is 6o for each press. When the louver swings at a certain angle which would affect the cooling and

heating effect of the air conditioner, it would automatically change the swing direction. No symbol will

appear in the display area when press this button.

Swing Button(left and right)Press the SWING button to activate the swing feature. Push the button

again to stop.

i Timer on ButtonPress this button to initiate the auto-on time sequence. Each press will increase the

auto-timed setting in 30 minutes increments. When the setting time displays 10Hr, each press will increase

the auto-timed setting 60 minutes increments. To cancel the auto-timed program, continue pressing the

button until 0.0 is displayed.

j Timer off ButtonPress this button to initiate the auto-off time sequence. Each press will increase the

auto-timed setting in 30 minutes increments. When the setting time displays 10Hr, each press will increase

the auto-timed setting 60 minutes increments. To cancel the auto-timed program, continue pressing the

button until 0.0 is displayed.

k RESET Button: When you press the recessed RESET button, all current settings are cancelled and the con-

trol will return to the initial settings.

l Turbo Button / Active Clean button: Push this button on COOL mode, the air conditioner goes into

powerful cooling operation. Push again to cancel the TURBO function. Upon pressing this button (> 2

sec) the unit will go into the Active Clean mode. A complete process will be started to clean the internal

side of the evaporator and to reduce the breeding of bacteria. When this function is activated all timer

settings will be cancelled. To stop the Active Clean mode press the button (> 2 sec) again.

m LOCK Button: When you press the recessed LOCK button, all current settings are locked in and the remote

controller does not accept any operation except that of the LOCK. Press again to cancel the LOCK mode.

n LED DISPLAY / FOLLOW ME Button: Press this button to clear the digit display in the air conditioner. The

digit display in the air conditioner will reactivate itself automatically after 3 seconds, when no buttons are

being pressed in this period. Press it again to activate it (Not applicable to units without this function).

When pushing more than 2 seconds, the FOLLOW ME function will be activated, pushing more than 2

seconds again to disable.

o Low sound button / indoor freezing prevention: Press this button to decrease the indoor sound pres-

sure level to 21 dB(A). The indoor unit fan speed is reduced to its lowest level. Upon pressing this button

(> 2 seconds) the unit will go into the freezing prevention mode. The unit will overrule the indoor tem-

perature setting and will set it to approx 8 °C. In this way preventing your home from freezing during

cold periods at the lowest possible energy consumption. When this mode is selected the indoor unit

display will show “FP”. This button can only be operated in heating mode. To leave the Home Freezing

Prevention Mode: simply press the button once again.

Names and Functions of indicators on Remote Controller

Qlima SC 4232 — Names and Functions of indicators on Remote Controller diagram (page 9)
Afb. 10 · Names and Functions of indicators on Remote Controll…
Page 10 of the Qlima SC 4232 user manual — AUTOMATIC Operation
Pagina 10 · klik om te vergroten
Pagina 10
a Transmission indicatorThis transmission indicator lights when remote controller transmits signals to

the indoor unit.

b Mode displayDisplays the current opeartion mode. Including Auto , Cool , Dry , Heat (Not

applicable to cooling only models), Fan .

c Temp. / Timer displayDisplays the temperature setting (17º C ~ 30ºC). When you set the operating

mode to FAN, no temperature setting is displayed. And if in the TIMER mode, shows the ON and OFF

settings of the TIMER.

d Fan speed display: Displays the selected fan speed, AUTO (no display), LOW , MED and HIGH . The

fan speed is AUTO when the operating mode is either AUTO or DRY.

e ON / OFF display: Displayed by pressing the ON / OFF button. Press the ON / OFF button again to remove.

f Lock display: Displayed when LOCK mode is activated.

g Sleep display: Displayed under sleeping operation. Press the SLEEP button again to remove.

Operating the Remote Controller

Install / Replace Batteries

Use two dry alkaline batteries (AAA/LR03).

Do not use rechargeable batteries.

1. Remove the battery cover on the back of the Remote Control by pulling it according to the arrow

direction shown on the cover.

2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.

3. Reattach the cover by sliding it back into position. G

  • NOTE!
  • When the batteries are removed, the remote controller erases all programming. After inserting new batteries, the remote controller must be reprogrammed.
  • When replacing batteries, do not use old batteries or a different type battery. This may cause the remote controller to malfunction.
  • If you do not use the remote controller for several weeks remove the batteries. Otherwise battery leakage may damage the remote controller.
  • The average battery life under normal use is about 6 months.
  • Replace the batteries when there is no answering beep from the indoor unit or if the Transmission Indicator light fails to appear.
  • Never mix new and old batteries. Never use different battery types (e.g. alkaline and manganese dioxide) simultaneously.

AUTOMATIC Operation

When the air conditioner is ready for use (check if unit is plugged in and whether electrical power is availa-

ble), switch on the power and the OPERATION indicator lamp on the display panel of the indoor unit starts

flashing.

1. Use the Mode select button to select AUTO.
2. Push the + or - button to set the desired room temperature.
3. Push the On/off button to start the air conditioner. The OPERATION lamp on the display panel of the

indoor unit lights. The FAN SPEED is automatically controlled.

4. Push the On/off button again to stop the unit operation.
Page 11 of the Qlima SC 4232 user manual — TIMER Operation
Pagina 11 · klik om te vergroten
Pagina 11
  • NOTE!
  • In the AUTO mode, the air conditioner can logically choose the mode COOL, FAN and HEAT by sensing the difference between the actual ambient room temperature and the set temperature on the remote controller.
  • If the AUTO mode is not comfortable for you , the desired mode can be selected manually.

COOL, HEAT, and FAN ONLY Operation

1. If the AUTO mode is not comfortable, you may manually override the settings by using COOL, DRY,

HEAT (HEAT PUMP units only), or FAN ONLY modes by pressing button b.

2. Push the + or - button ( c and d ) to set the desired room temperature.
3. Push the Fan button e to select the FAN mode of AUTO, HIGH, MED or LOW.
4. Push the On/off button a . The operation lamp lights and the air conditioner starts to operate per your

settings. Push the On/off button a again to stop this unit operation. G

DRY Operation

1. Push the Mode button b to select DRY.
2. Push the + or - button ( c and d ) to set the desired temperature.
3. Push the On/off button a . The operation lamp lights and the air conditioner starts to operate in the DRY

mode. Push the On/off button a again to stop this unit operation. G

TIMER Operation

Push Timer on/off button (i and j) to set the on and off times of the unit. The effective operation time set

by the remote controller for the timer function is limited to a period of between 0.5 and less than 24 hours.

1. To set the STARTING time .

1.1 Push the Timer on button i, then the remote controller display shows ON TIMER, the last set time for

the starting operation and the signal “h” will be shown on the Timer display area. You are now ready

to reset the time to START the operation.

1.2 Push the Timer on button i again to set desired unit start time.

1.3 After setting the Timer on,there will be half a second delay before the remote controller transmits the

signal to the air conditioner.

2. To set the STOPPING time.

2.1 Push the Timer off button j and the remote controller display will show OFF TIMER and the last set

time for the timer off operation in hours will be shown on the Timer display area. You are now ready

to reset the time of the STOP operation.

2.2 Push the Timer off button j again to set the time you want to stop the operation.

2.3 After setting the Timer off, there will be half a second delay before the remote controller transmits the

signal to the air conditioner.

Page 12 of the Qlima SC 4232 user manual — indicator remains on and this function is activated. G
Pagina 12 · klik om te vergroten
Pagina 12

Example of timer setting

TIMER ON

To start the air conditioner in 6 hours.

1. Press the TIMER ON button, the last setting of starting operation time and the

signal “h” will show on the display area.

2. Press the TIMER ON button to display “6:0h” .
3. Wait for one second and the digital display area will show the temperature again.

The “TIMER ON” indicator remains on and this function is activated.

Combined timer

TIMER ON OFF

(setting both ON and OFF timers simultaneously)

TIMER OFF --> TIMER ON

(On --> Stop --> Start operation)

This feature is useful when you want to stop the air conditioner after you go to bed, On

and start it again in the morning when you wake up or when you return home.

Example:

To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.

1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display 2.0h on the TIMER OFF display
3. Press the TIMER ON button
4. Press the TIMER ON button again to display 10h on the TIMER ON display
5. Wait for one second and the digital display area will show the temperature again. The TIMER ON OFF

indicator remains on and this function is activated. G

  • NOTE!
  • If the same time is set for both START and STOPPING settings, the stopping time will automatically increase 0.5hr (the set time displays less than 10hr) or one hour (the set time displays 10hr or more).
  • To change the Timer on/off time, just press the corresponding TIMER button and reset the time.
  • The setting time is relative time. That is the time set is based on the delay of the current time.
  • WARNING
  • Keep the remote controller away from all liquids.
  • Protect the remote controller from high temperatures and exposure to radiation.
  • Keep the indoor receiver out of direct sunlight or the air conditioner may malfunction.
Show 7 more labels / short text on this page
Start · Off · 6 h · On · Stop · 2 h Set · 10 h
Page 13 of the Qlima SC 4232 user manual — F OPTIMAL OPERATION
Pagina 13 · klik om te vergroten
Pagina 13

E MANUAL OPERATION (WITHOUT REMOTE)

How to operate your unit without the remote control.

In the event that your remote control fails to work, your unit can be operated manually with the MANUAL

CONTROL button located on the indoor unit. Note that manual operation is not a long-term solution, and

that operating the unit with your remote control is strongly recommended.

BEFORE MANUAL OPERATION Unit must be turned off before manual operation.

To operate your unit manually:

1. Locate the MANUAL CONTROL button on the right-hand side panel of the unit.
2. Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
3. Press the MANUAL CONTROL button again to activate FORCED COOLING mode.
4. Press the MANUAL CONTROL button a third time to turn the unit off.

F OPTIMAL OPERATION

To achieve optimal performance, please note the following:

  • Adjust the air flow direction correctly so that it is not directly directed to people.
  • Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive tem-

perature levels.

  • Close doors and windows otherwise the desired effect may be reduced.
  • Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be

reduced and the air conditioner may stop running. Make sure there are no obstacles blocking the air

flow. The air stream must be allowed to reach the entire room unhindered. Also the air stream must

be allowed to reach the air conditioner unhindered.

  • Clean the air filter periodically, otherwise cooling or heating performance may be reduced. It is

advised to clean the filters every two weeks.

  • Do not operate unit with horizontal louvre in closed position.

Manual · control button · Manual control button

Page 14 of the Qlima SC 4232 user manual — CAUTION!
Pagina 14 · klik om te vergroten
Pagina 14

G ADJUSTING AIR FLOW DIRECTION

Qlima SC 4232 — G ADJUSTING AIR FLOW DIRECTION diagram (page 14)
Afb. 11
  • Adjust the air flow direction properly otherwise, it might cause discomfort

or cause uneven room temperatures.

  • Adjust the horizontal louver using button h on the remote controller.
  • Adjust the vertical louver manually.

Adjusting the horizontal Air Flow Direction (up - down)

Qlima SC 4232 — G ADJUSTING AIR FLOW DIRECTION diagram (page 14)
Afb. 12

The air conditioner automatically adjusts the horizontal air flow direction in accord-

ance with the operating mode.

To set the horizontal air flow direction

Perform this function while the unit is in operation. Keep pressing the AIR DIRECTION

button h on the remote controller to move the louver to the desired direction.

  • Adjust the horizontal air flow direction to the desired direction.
  • In subsequent operations, the horizontal air flow is automatically set in the

direction to which you adjusted the louver by pressing the AIR DIRECTION

button.

To set the vertical air flow direction (left - right)

Adjust the vertical louver manually using the lever in the middle of the vertical

louver arm (depending on model). When the air conditioner is in operation and the

vertical louver is in a specific position, move the lever at left (or right, depending

on model) end of the air outlet to the desired position.

CAUTION!

Take care, do not touch the fan behind the vertical louvers!

To automatically swing the air flow direction (up - down)

Perform this function while the air conditioner is in operation.

  • Press the SWING g button on the remote controller.
  • To stop the function, press the SWING button g again. Press AIR DIRECTION h button to lock louver in

desired position.

  • CAUTION
  • The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the TIMER ON is set).
  • Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dry mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop.
  • Do not move the horizontal louver manually. Always use the AIR DIRECTION h or SWING button g . If you move this louver manually, it may malfunction during operation. If the louver malfunctions, stop the air conditioner once and restart it.
  • When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds.
  • Do not operate unit with horizontal louver in closed position.

Range · Deflector rod

Page 15 of the Qlima SC 4232 user manual — NOTE
Pagina 15 · klik om te vergroten
Pagina 15

H HOW THE AIR CONDITIONER WORKS

AUTOMATIC OPERATION

  • When you set the air conditioner in AUTO mode (button 2 on the remote

controller), it will automatically select COOLING, HEATING or FAN only

1 hour 1 hour

operation depending on what temperature you have selected and the room

COOLING

temperature.

  • The air conditioner will control room temperature automatically round the

temperature point set by you.

  • If the AUTO mode is uncomfortable, you can select desired conditions man-

1 hour 1 hour

HEATING

ually.

SLEEP/ECONOMIC OPERATION

Cooling Fan only Cooling Fan only Cooling

  • When you push SLEEP button f during COOLING, HEATING or AUTO oper-

ation, the air conditioner will automatically increase (cooling) or decrease

(heating) 1ºC per hour. The set temperature will be steady 2 hours later and

remains steady for 5 hours. After 5 hours the unit will stop. The fan speed

DEHUMIDIFYING

will be automatically controlled.

DEHUMIDIFYING OPERATION

  • The dehumidifying mode will automatically select the dehumidifying operation based on the difference

between the set temperature and the actual room temperature.

  • The temperature is regulated while dehumidifying by repeatingly turning on and off of the cooling

operation or fan only. The fan speed is controlled automatically.

  • In normal cooling operation the air conditioner will also dehumidify the air. G

NOTE

When the air conditioner is dehumidifying it is likely that the room temperature will decrease.

It is therefore normal that a hygrostat will measure a higher relative humidity. The absolute

humidity in the room will however be lowered, depending on the amount of moisture produced

in the room (cooking, people etc).

Show 7 more labels / short text on this page
Press Sleep button · Set Tempe- rature · Press Sleep button · Set Tempe- rature · Room tempe- rature · Time · Set temperature
Page 16 of the Qlima SC 4232 user manual — Cleaning the filter
Pagina 16 · klik om te vergroten
Pagina 16

I MAINTENANCE

hold Drain Cleaner No

Cleaning the indoor unit and remote controller

  • CAUTION
  • Use a dry cloth to wipe the indoor unit and remote controller.
  • A cloth dampened with cold water may be used on the indoor unit if it is very dirty.
  • The front panel of the indoor unit can be removed and cleaned with water. Then wipe it with a dry cloth.
  • Do not use a chemically treated cloth or duster to clean the unit.
  • Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform.

Cleaning the filter

A clogged air filter reduces the cooling efficiency of this unit. Clean the filter once every 2

weeks.

1. The air filter is under the top air inlet grill.
2. Grip the tab on the end of the filter, lift it up, then pull it towards yourself.
3. Remove the screen filter from the indoor unit.
  • Clean the screen filter once every two weeks.
  • Clean screen filter with a vacuum cleaner or water.
4. The black active carbon filter cannot be cleaned. This filter will simply not filter

Remove air freshening filter from back of larger filter (some units)

unpleasant odours anymore once dirty. At that moment this filter needs to be

replaced by a new filter. (available at your dealer). It is advised to exchange this filter

twice every season.

5. The green coloured 3M HAF filter will show clear signs of dirt on and in the filter

once dirty. When dirty this filter cannot be cleaned and needs to be replaced by a

new filter (available at your dealer). It is advised to exchange this filter twice every

season.

Recommended change of filter

6. After replacing the active carbon filter and the 3M HAF filter in the filter holder on

the screen filter, the screen filter can be replaced into the air conditioner.

7. Ensure before replacing that the filter is completely dry and has no defects.
8. Install the air freshening filter back into position.
9. Insert the upper portion of air filter back into the unit taking care that the left and

right edges line up correctly and place filter into position.

Show 5 more labels / short text on this page
House- · Thinner · Filter Tabs · f · New filter
Page 17 of the Qlima SC 4232 user manual — J OPERATION TIPS
Pagina 17 · klik om te vergroten
Pagina 17

Maintenance

If you plan to idle the unit for a long time, perform the following:

1. Operate the fan for about 6 hours to dry the inside of the unit.
2. Stop the air conditioner and disconnect power. If a 4.8kW model is used, interrupt the power supply.

Remove the batteries from the remote controller.

3. The outdoor unit requires periodic maintenance and cleaning. This should only be done by an author-

ized airconditioning engineer.

Checks before operation

  • Check that the wiring is not broken or disconnected.
  • Check that the air filter is installed.
  • Check if the air outlet or inlet is not blocked after the air conditioner has not been used for a long time.
  • CAUTION
  • Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
  • Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
  • When cleaning the unit, first make sure that the power and circuit breaker are turned off.

J OPERATION TIPS

The following events may occur during normal operation.

1. Protection of the air conditioner.
  • The compressor cannot restart for 3 minutes after it stops.
  • The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one

of the following three situations and the set temperature has not been reached.

A. When heating has just started.

B. Defrosting.

C. Low temperature heating.

  • The indoor or outdoor fan stops running when defrosting.
  • Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and

humidity is high resulting in lower heating efficiency of the air conditioner.

  • During this condition air conditioner will stop heating operation periodically and start defrosting

automatically.

  • The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the

amount of frost buildup on the outdoor unit.

2. A white mist coming out from the indoor unit.
  • A white mist may generate due to a large temperature difference between air inlet and air outlet on

COOL mode in an indoor environment that has a high relative humidity.

  • A white mist may generate due to moisture generated from defrosting process when the air condi-

tioner restarts in HEAT mode operation after defrosting.

Compressor protection · Anti-cold air · Defrosting

Page 18 of the Qlima SC 4232 user manual — Maintenance
Pagina 18 · klik om te vergroten
Pagina 18
3. Low noise of the air conditioner.
  • You may hear a low hissing sound when the compressor is running or has just stopped running. This

sound is the sound of the refrigerant flowing or coming to a stop.

  • You can also hear a low “squeak” sound when the compressor is running or has just stopped run-

ning. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the

temperature is changing.

  • A sound may be heard due to louver restoring to its original position when power is first turned on.
4. Dust is blown out from the indoor unit.
  • This is a normal condition when the air conditioner has not been used for a long time or during first

use of the unit.

5. A peculiar smell comes out from the indoor unit.
  • This is caused by the indoor unit giving off smells permeated from building material, from furniture,

or smoke.

6. The air conditioner turns to FAN only mode from COOL or HEAT mode.
  • When indoor temperature reaches the temperature setting on air conditioner, the compressor will

stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again

when the indoor temperature rises on COOL mode or falls on HEAT mode to the set point.

7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively

humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air out-

let position and select HIGH fan speed.

8. Heating mode.
  • The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit dur-

ing heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner

decreases accordingly and the heating capacity will decrease. At the same time, heat loading of the

air conditioner increases due to larger difference between indoor and outdoor temperature. If a com-

fortable temperature cannot be achieved by the air conditioner, it is advised to use a supplementary

heating device.

9. Auto-restart function.
  • Power failure during operation will stop the unit completely.

The air conditioner is equipped with Auto-restart feature, when the power restores, the unit restarts

automatically with all the previous settings preserved by the memory function.

10. Refrigerant leak detection.
  • The air conditioner is provided with a Refrigerant leak detection system.

When the outdoor unit detects a shortage of refrigerant, the air conditioner will stop and the indoor

unit shows the alarm EC on the display.

When this alarm occurs, do not restart the air conditioner and contact your supplier.

Page 19 of the Qlima SC 4232 user manual — Malfunctions and Solutions
Pagina 19 · klik om te vergroten
Pagina 19

K TROUBLE SHOOTING TIPS

Malfunctions and Solutions

  • TROUBLE Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact your supplier.
  • Fuse blows frequently or circuit breaker trips frequently.
  • Other objects or water penetrate the air conditioner.
  • The remote controller won’t work or works abnormally.
  • Other abnormal situations.

The Unit has a 3-minute protection feature that prevents the unit from over- loading. The unit cannot be restarted within three minutes of being turned off.

Unit does not turn on when pressing ON/OFF button

The unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previ- ously selected mode again.

The unit changes from COOL/ HEAT mode to FAN mode

The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctu- ates again.

The indoor unit emits white mist In humid regions, a large temperature difference between the room’s air

and the conditioned air can cause white mist.

Both the indoor and outdoor units emit white mist

When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.

A rushing air sound may occur when the louver resets its position.

The indoor unit makes noises

A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.

Low hissing sound during operation: This is normal and is caused by refrige- rant gas flowing through both indoor and outdoor units.

Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.

Both the indoor unit and out- door unit make noises

Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.

The outdoor unit makes noises The unit will make different sounds based on its current operating mode.

Dust is emitted from either the indoor or outdoor unit

The unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by cove- ring the unit during long periods of inactivity.

The unit may absorb odors from the environment (such as furniture, cook- ing, cigarettes, etc.) which will be emitted during operations.

The unit emits a bad odor

The unit’s filters have become moldy and should be cleaned.

The fan of the outdoor unit does not operate During operation, the fan speed is controlled to optimize product operation.

  • Interference from cell phone towers and remote boosters may cause the unit to malfunction. In this case, try the following:
  • Disconnect the power, then reconnect.
  • Press ON/OFF button on remote control to restart operation.

Operation is erratic, unpredicta- ble, or unit is unresponsive

Issue Possible Causes

Page 20 of the Qlima SC 4232 user manual — K TROUBLE SHOOTING TIPS
Pagina 20 · klik om te vergroten
Pagina 20
Qlima SC 4232 — K TROUBLE SHOOTING TIPS diagram (page 20)
Afb. 13

Temperature setting may be higher than ambient room temperature Lower the temperature setting

The heat exchanger on the indoor or out- door unit is dirty Clean the affected heat exchanger

The air filter is dirty Remove the filter and clean it according to instructions

The air inlet or outlet of either unit is blocked

Turn the unit off, remove the obstruction and turn it back on

Doors and windows are open Make sure that all doors and windows are closed while operating the unit

Excessive heat is generated by sunlight Close windows and curtains during peri- ods of high heat or bright sunshine

Too many sources of heat in the room (people, computers, electronics, etc.) Reduce amount of heat sources

Low refrigerant due to leak or long-term use

Check for leaks, re-seal if necessary and top off refrigerant

SILENCE function can lower product per- formance by reducing operating frequen- cy. Turn off SILENCE function.

SILENCE function is activated(optional function)

Power failure Wait for the power to be restored

The power is turned off Turn on the power

The fuse is burned out Replace the fuse

The unit is not working

Remote control batteries are dead Replace batteries

The Unit’s 3-minute protection has been activated

Wait three minutes after restarting the unit

Timer is activated Turn timer off

There’s too much or too little refrigerant in the system

Check for leaks and recharge the system with refrigerant.

Incompressible gas or moisture has ente- red the system.

Evacuate and recharge the system with refrigerant

The unit starts and stops frequently

The compressor is broken Replace the compressor

The voltage is too high or too low Install a manostat to regulate the voltage

The outdoor temperature is exetremtly low Use auxiliary heating device

Cold air is entering through doors and windows

Make sure that all doors and windows are closed during use

Low refrigerant due to leak or long-term use

Check for leaks, re-seal if necessary and top off refrigerant

Indicator lamps continue flashing The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the power and contact your nearest customer ser- vice center.

  • Error code appears in the window display of indoor unit:
  • E0, E1, E2…
  • P1, P2, P3…
  • F1, F2, F3…

Problem Cause Solution · Poor Cooling Performance · Poor heating performance

Page 21 of the Qlima SC 4232 user manual — L GUARANTEE CONDITIONS
Pagina 21 · klik om te vergroten
Pagina 21

If the trouble has not been corrected, please contact your supplier. Be sure to inform them of the detailed

malfunctions and unit model.

L GUARANTEE CONDITIONS

The air conditioner is supplied with a 48-month guarantee on the compressor and a 24-month guarantee on

other components, commencing on the date of purchase. The following rules apply:

1. We expressly refuse all further damage claims, including claims for collateral damage.
2. Repairs to or replacement of components within the guarantee period will not result in an extension of

the guarantee.

3. The guarantee is invalidated if any modifications have been made, non genuine parts are fitted or

repairs are carried out by third parties.

4. Components subject to normal wear, such as the filter, are not covered by the guarantee.
5. The guarantee is valid only when you present the original, dated purchase invoice and if no modifica-

tions have been made.

6. The guarantee is invalid for damage caused by neglect or by actions that deviate from those in this

instruction booklet.

7. Transportation costs and the risks involved during the transportation of the air conditioner or air con-

ditioner components shall always be for the account of the purchaser.

8. Damage caused by not using suitable filters is not covered by the guarantee.
9. Refrigerant loss and/or leakage because of incompetent (dis)connecting of the units and/or (dis-) con-

nection of the units by not qualified personnel is not covered by the guarantee conditions applicable to

this product. Damage to units which are mounted, connected and/or disconnected not following local

law and/or legislation and/or not following the guidelines in this manual is not covered by the guaran-

tee conditions applicable to this product.

Consult your dealer for repairs if these instructions do not provide a solution. Make sure that in the unlikely

case of needed disconnection, that disconnection is always done by qualified, authorized personnel and

according to your local laws and legislation.

Page 22 of the Qlima SC 4232 user manual — **** EN12102-2008
Pagina 22 · klik om te vergroten
Pagina 22

M TECHNICAL DATA

S 4225 S 5225 S 5225 B S-JA 2519

SC 4225 SC 5225 SCJA-2519

SC 4248 SC 5248 SCJA-4819

S 4232 S 5232

S 4248 S 5248

SC 4232 SC 5232

Type air-conditioner Wall mounted split Wall mounted split Wall mounted split Wall mounted split Wall mounted split Wall mounted split

Cooling capacity nominal (min- max) * W 2600 (1030 - 3190) 3500 (820 - 4160) 5300 (1730 - 6980) 2500 (1590 - 3000) 3200 (2110 - 4000) 4600 (1820 - 6120)

EE Class cooling * A++

SEER* 7.1 7.0 6.4 6.5 6.2 6.7

Heating capacity nominal (min- max) * W 2500 ( 880 - 3660) 2700 ( 850 - 4780) 3900 (1060 - 6980) 2400 (960 - 4890) 2400 (1280 - 4900) 3800 (1380 - 6740)

EE Class heating * A+

SCOP* 4.0 4.1 4.0

Dehumidifying capacity (at 32°C/80%) ** / *** L / 24 h 24.0 28.8 43.2 26.4 31.2 36.0

Power consumption cooling kW 0.70 1.09 1.54 0.71 1.19 1.40

Power consumption heating kW 0.67 1.05 1.46 0.84 1.23 1.90

Annual energy consumption * kWh 128 / 875 175 / 922 290 / 1365 137 / 836 187 / 834 245 / 1326

Power supply V / Hz / Ph 220-240~ / 50 / 1 220-240~ / 50 / 1 220-240~ / 50 / 1 220-240~ / 50 / 1 220-240~ / 50 / 1 220-240~ / 50 / 1

Max. Current A 9.5 10.0 11.5 10.0 10.0 13.0

Air flow ** m3/h 416/309/230 539/478/294 750/505/420 545/435/368 545/435/368 770/610/410

For rooms up to** m3 60-85 80-100 140-185 60-85 80-100 125-145

Suited for regions W / A / C W/A/C

Compressor type Rotary

Fan speeds 4 4 4 3 3 3

Thermostatic range oC 17 - 30 17 - 30 17 - 30 17 - 30 17 - 30 17 - 30

Controls manual / mechanic / electronic Electronic remote Electronic remote Electronic remote Electronic remote Electronic remote Electronic remote

Remote control Yes / No Y

Air filter type(s) Screen. Active carbon.

3M HAF Screen. Active carbon.

3M HAF Screen. Active carbon.

3M HAF Screen. Active carbon.

3M HAF Screen. Active carbon.

3M HAF Screen. Active carbon.

3M HAF

Refrigerant type / charge R / g R32 / 700 R32 / 800 R32 / 1250 R32 / 800 R32 / 800 R32 / 1190

Refrigerant GWP 675

CO2 equivalent tonnes 0.473 0.540 0.844 0.540 0.540 0.803

Dimensions indoor unit (w x h x d) mm 722x187x290 802x189x297 965x215x319 805x194x285 805x194x285 957x213x302

Dimensions outdoor unit (w x h x d) mm 770x300x555 770x300x555 800x333x554 770x300x555 770x300x555 800x333x554

Net weight indoor unit kg 7.3 8.2 10.8 7.8 7.8 10.3

Net weight outdoor unit kg 27.2 27.0 37.0 25.7 25.7 34.6

Gross weight indoor unit kg 9.7 10.7 14.1 10.4 10.4 13.8

Gross weight outdoor unit kg 29.7 29.4 39.9 31.1 31.1 40.2

Sound pressure level indoor unit **** dB(A) 54 56 58 53 53 55

Sound pressure level outdoor unit **** dB(A) 59 60 64 62 62 62

Sound pressure level indoor unit (low) **** dB 20 21 21 25 25 29

Unit protection indoor IP IPX0

Unit protection outdoor IP IPX4

* EN 14511 / EN14825

** To be used as indication

*** Moisture removal at 32°C, 80% RH

**** EN12102-2008

Model

Page 23 of the Qlima SC 4232 user manual — M TECHNICAL DATA
Pagina 23 · klik om te vergroten
Pagina 23

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection

facilities. Contact your local government for information regarding the collection systems

available. If electrical appliances are disposed of in landfills or dumps, hazardous substanc-

es can leak into the groundwater and get into the food chain, damaging your health and

well-being. When replacing old appliances with new once, the retailer is legally obligated to

take back your old appliance for disposal at least for free of charge. Do not throw batteries

into the fire, where they can explode or release dangerous liquids. If you replace or destroy

the remote control, remove the batteries and throw them away in accordance with the

applicable regulations because they are harmful to the environment.

Environmental informationThis equipment contains fluorinated greenhouse gases covered by the Kyoto

Protocol. It should only be serviced or dismantled by professional trained personnel.

This equipment contains R32 refrigerant in the amount as stated in the table above. Do not vent R32 into

atmosphereR32, is a fluorinated greenhouse gas with a Global Warming Potential (GWP) = 675

Internet:

For your convenience you can download the latest version of the user-, installation- and/or service manual

on www.Qlima.com

Page 24 of the Qlima SC 4232 user manual — M TECHNICAL DATA
Pagina 24 · klik om te vergroten
Pagina 24
Page 24 of the Qlima SC 4232 user manual — M TECHNICAL DATA
Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
Unit does not turn on when pressing ON/OFF buttonThe Unit has a 3-minute protection feature that prevents the unit from over- loading. The unit cannot be restarted within three minutes of being turned off. p.19
The unit changes from COOL/ HEAT mode to FAN modeThe unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previ- ously selected mode again. p.19
The unit changes from COOL/ HEAT mode to FAN modeThe set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctu- ates again. p.19
The indoor unit emits white mistIn humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist. p.19
Both the indoor and outdoor units emit white mistWhen the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process. p.19
The indoor unit makes noisesA rushing air sound may occur when the louver resets its position. p.19
The indoor unit makes noisesA squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts. p.19
Both the indoor unit and out- door unit make noisesLow hissing sound during operation: This is normal and is caused by refrige- rant gas flowing through both indoor and outdoor units. p.19
Both the indoor unit and out- door unit make noisesLow hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction. p.19
Both the indoor unit and out- door unit make noisesSqueaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises. p.19
The outdoor unit makes noisesThe unit will make different sounds based on its current operating mode. p.19
Dust is emitted from either the indoor or outdoor unitThe unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by cove- ring the unit during long periods of inactivity. p.19
The unit emits a bad odorThe unit may absorb odors from the environment (such as furniture, cook- ing, cigarettes, etc.) which will be emitted during operations. p.19
The unit emits a bad odorThe unit’s filters have become moldy and should be cleaned. p.19
The fan of the outdoor unit does not operateDuring operation, the fan speed is controlled to optimize product operation. p.19
Operation is erratic, unpredicta- ble, or unit is unresponsiveInterference from cell phone towers and remote boosters may cause the unit to malfunction. In this case, try the following: • Disconnect the power, then reconnect. • Press ON/OFF button on remote control to restart operation. p.19
Poor Cooling PerformanceTemperature setting may be higher than ambient room temperatureLower the temperature setting p.20
Poor Cooling PerformanceThe heat exchanger on the indoor or out- door unit is dirtyClean the affected heat exchanger p.20
Poor Cooling PerformanceThe air filter is dirtyRemove the filter and clean it according to instructions p.20
Poor Cooling PerformanceThe air inlet or outlet of either unit is blockedTurn the unit off, remove the obstruction and turn it back on p.20
Poor Cooling PerformanceDoors and windows are openMake sure that all doors and windows are closed while operating the unit p.20
Poor Cooling PerformanceExcessive heat is generated by sunlightClose windows and curtains during peri- ods of high heat or bright sunshine p.20
Poor Cooling PerformanceToo many sources of heat in the room (people, computers, electronics, etc.)Reduce amount of heat sources p.20
Poor Cooling PerformanceLow refrigerant due to leak or long-term useCheck for leaks, re-seal if necessary and top off refrigerant p.20
Poor Cooling PerformanceSILENCE function is activated(optional function)SILENCE function can lower product per- formance by reducing operating frequen- cy. Turn off SILENCE function. p.20
The unit is not workingPower failureWait for the power to be restored p.20
The unit is not workingThe power is turned offTurn on the power p.20
The unit is not workingThe fuse is burned outReplace the fuse p.20
The unit is not workingRemote control batteries are deadReplace batteries p.20
The unit is not workingThe Unit’s 3-minute protection has been activatedWait three minutes after restarting the unit p.20
The unit is not workingTimer is activatedTurn timer off p.20
The unit starts and stops frequentlyThere’s too much or too little refrigerant in the systemCheck for leaks and recharge the system with refrigerant. p.20
The unit starts and stops frequentlyIncompressible gas or moisture has ente- red the system.Evacuate and recharge the system with refrigerant p.20
The unit starts and stops frequentlyThe compressor is brokenReplace the compressor p.20
The unit starts and stops frequentlyThe voltage is too high or too lowInstall a manostat to regulate the voltage p.20
Poor heating performanceThe outdoor temperature is exetremtly lowUse auxiliary heating device p.20
Poor heating performanceCold air is entering through doors and windowsMake sure that all doors and windows are closed during use p.20
Poor heating performanceLow refrigerant due to leak or long-term useCheck for leaks, re-seal if necessary and top off refrigerant p.20
Indicator lamps continue flashingThe unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the power and contact your nearest customer ser- vice center. p.20
Error code appears in the window display of indoor unit: • E0, E1, E2… • P1, P2, P3… • F1, F2, F3… p.20

Vraag stellen over de Qlima SC 4232

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Qlima SC 4232

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Qlima SC 4232 handleiding-pdf

196 pagina's·14.6 MB·Airconditioner·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…