NL
Roland logo
Officiële handleiding

Roland PCR-A30

112 pagina's·4.3 MB·Geluid·PDF·EN
Roland PCR-A30
Inhoudsopgave 1 secties MIDI implementatie TonenVerbergen
Page 1 of the Roland PCR-A30 user manual — 2. Transmit data ■ Channel voice messages
Pagina 1 · klik om te vergroten
Pagina 1
  • 1. Receive data
  • System exclusive messages
  • Universal non-realtime system exclusive message

2. Transmit data ■ Channel voice messages

In addition to the channel voice messages that can be transmitted in each mode, the PCR-A30 lets you assign any channel voice message to any controller and transmit it.

❍Identity request message

Status Data byte Status F0H 7EH, dev, 06H, 01H F7H

  • Note off

Status 2nd byte 3rd byte 9nH kkH 00H

Byte Explanation F0H Exclusive status 7EH ID number (Universal non-realtime system exclusive message) dev Device ID (10 or 7FH (Broadcast)) 06H Sub ID #1 (PCR-A30) 01H Sub ID #1 (PCR-A30) F7H EOX (End of Exclusive)

n = MIDI channel number:0H – FH (Ch.1 – 16) kk = note number: 00H – 7FH (0 – 127)

* Transmitted when you release a key in Play mode.

  • Note on

Status 2nd byte 3rd byte 9nH kkH vvH

  • Data transmission

The PCR-A30 can use Bulk Dump (p. 104) to transfer its internal memory set data (p. 88).

n = MIDI channel number: 0H – FH (Ch.1 – 16) kk = note number: 00H – 7FH (0 – 127) vv = note on velocity: 01H – 7FH (1 – 127)

❍Data Set 1 (DT1)

These messages transmit the actual data, and are used to transfer data settings to a device.

* Transmitted when you push a key in Play mode.

Status Data byte Status F0H 41H, 10H, 00H, 62H, 12H, aaH, ddH, ...eeH, sum F7H

  • Polyphonic key pressure

Status 2nd byte 3rd byte AnH kkH vvH

Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID (For the PCR-A30, fixed at 10H) 00H Model ID #1 (PCR-A30) 62H Model ID #1 (PCR-A30) 12H Command ID (RQ1) aaH Address ddH Data : : : eeH Data sum Checksum F7H EOX (End of Exclusive)

n = MIDI channel number: 0H – FH (Ch.1 – 16) kk = note number: 00H – 7FH (0 – 127) vv = key pressure: 00H – 7FH (0 – 127)

  • Control change

Status 2nd byte 3rd byte BnH ccH vvH

n = MIDI channel number: 0H – FH (Ch.1 – 16) cc = controller number: 00H – 77H vv = control value: 00H – 7FH

❍Bank Select (Controller number 0, 32)

Status 2nd byte 3rd byte BnH 00H mmH BnH 20H llH

* The amount of data that can be transmitted at once is fixed for each type of data. Data that does not have the specified starting address and data size will not be received. Refer to the explanation in 3. Bulk Dump (p. 104). * There must be an interval of at least 40 ms between each exclusive message that is sent. * Also, you must leave an interval of at least 500 ms after transmitting one set of bulk dump data.

n = MIDI channel number: 0H – FH (Ch.1 – 16) mm = Bank number MSB: 00H – 7FH ll = Bank number LSB: 00H – 7FH

* Transmitted in Bank mode.

❍Modulation (Controller number 1)

Status 2nd byte 3rd byte BnH 01H vvH

n = MIDI channel number:0H – FH (Ch.1 – 16) vv = Modulation depth:00H – 7FH (0 – 127)

* Transmitted by upward/downward operation of the BENDER lever in Play mode.

Page 2 of the Roland PCR-A30 user manual — MIDI implementatie
Pagina 2 · klik om te vergroten
Pagina 2
  • Program change
  • System common message

Status 2nd byte CnH ppH

On the PCR-A30 you can assign the following system common messages to any controller and transmit them.

n = MIDI channel number: 0H – FH (Ch.1 – 16) pp = Program number: 00H – 7FH (prog. 1 – prog. 128)

  • MTC quarter frame

Status 2nd byte F1H mmH

* Transmitted in Program change mode.

mm = Message type/value

  • Channel pressure

Status 2nd byte DnH vvH

  • Song position pointer

Status 2nd byte 3rd byte F2H mmH llH

n = MIDI channel number: 0H – FH (Ch.1 – 16) vv = Channel pressure: 00H – 7FH (0 – 127)

mm, ll = Song position00 00H - 7F 7FH (0-16383)
  • Pitch bend change
  • Song select

Status 2nd byte 3rd byte EnH llH mmH

Status 2nd byte F3H mmH

n = MIDI channel number: 0H – FH (Ch.1 – 16) mm, ll = Pitch Bend value: 00 00H – 40 00H – 7FH 7FH (-8192 – 0 – +8191) * Transmitted by rightward/leftward operation of the BENDER lever in Play mode.

mm = Song number00 00H - 7F 7FH (0-16383)
  • Tune request
  • Channel mode messages
  • System realtime message

In addition to the channel mode messages that can be transmitted in Panic mode, the PCR-A30 lets you assign any channel voice message to any controller and transmit it.

In addition to the Active Sensing messages that are transmitted constantly, the PCR-A30 allows you to assign the following system realtime messages (other than Active Sensing) to any controller and transmit them.

  • Channel mode messages
  • Timing clock

Status 2nd byte 3rd byte BnH ccH vvH

n = MIDI channel number: 0H – FH (Ch.1 – 16) cc = controller number: 78H – 7FH vv = control value: 00H – 7FH

* Transmitted if the System setting F8 CLOCK is ON.

  • Start

❍All sounds off (Controller number 120)

Status 2nd byte 3rd byte BnH 78H 00H

  • Continue
n = MIDI channel number0H – FH (Ch.1 – 16)

* Transmitted in Panic mode.

  • Stop

❍Reset all controllers (Controller number 121)

Status 2nd byte 3rd byte BnH 79H 00H

  • Active sensing
n = MIDI channel number0H – FH (Ch.1 – 16)

* Transmitted in Panic mode.

❍All notes off (Controller number 123)

* Transmitted at intervals of approximately 250 ms. * Cannot be assigned to a controller.

Status 2nd byte 3rd byte BnH 7BH 00H

  • System reset
n = MIDI channel number0H – FH (Ch.1 – 16)

* Transmitted in Panic mode.

Show 7 more labels / short text on this page
Status F6H · Status F8H · Status FAH · Status FBH · Status FCH · Status FEH · Status FFH
Page 3 of the Roland PCR-A30 user manual — ❍ V-LINK OFF
Pagina 3 · klik om te vergroten
Pagina 3
  • System exclusive message

❍Sender Model Name

The PCR-A30 is able to transmit the following exclusive messages: exclusive messages assigned to the controllers, Identity Reply, V-LINK messages, and Bulk Dump.

Transmitted when entering V-LINK mode. Status Data byte Status F0H 41H,10H,00H,51H,12H, F7H 10H,71H,00H,45H,44H,49H,52H,4FH,4CH, 20H,50H,43H,52H,00H,3BH

  • Universal non-realtime system exclusive

Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID (For the PCR-A30, fixed at 10H) 00H 51H Model ID (V-LINK) 12H Command ID (DT1) aaH Address 10H 71H 00H Data 45H 44H 49H Model name (EDIROL PCR) 52H 4FH 4CH : 20H 50H 43H : 52H 00H : 3BH Checksum F7H EOX (End of Exclusive)

This message will be transmitted when an Identity Request message is received.

Status Data byte Status F0H 7EH,10H,06H,02H,41H,62H,01H, F7H 00H,00H,01H,01H,00H,00H

Byte Explanation F0H Exclusive status 7EH ID number (Universal non-realtime message) 10H Device ID (For the PCR-A30, fixed at 10H) 06H Sub ID #1 (General Information) 02H Sub ID #1 (Identity Reply) 41H ID number (Roland) 62H 01H Device family code 00H 00H Device family number code 01H 01H Software revision level 00H 00H : F7H EOX (End of Exclusive)

  • Data Set 1 DT1 (12H)

Transmitted when you execute Bulk TX in the Bulk mode. Status Data byte Status F0H 41H, 10H, 00H, 62H, 12H, aaH, ddH, ...eeH, sum F7H

  • V-LINK message

❍ V-LINK ON

Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID 00H Model ID #1 (PCR-A30) 62H Model ID #1 (PCR-A30) 12H Command ID (RQ1) aaH Address ddH Data : : : eeH Data sum Checksum F7H EOX (End of Exclusive)

Transmitted when entering V-LINK mode.

Status Data byte Status F0H 41H,10H,00H,51H,12H, F7H 10H,00H,00H,01H,0FH,0FH,51H

Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID (For the PCR-A30, fixed at 10H) 00H 51H Model ID (V-LINK) 12H Command ID (DT1) 10H 00H 00H Address 01H V-LINK ON 0FH Clip Control Rx. MIDI Ch. (16ch) 0FH Color Control Rx. MIDI Ch. (16ch) 51H Checksum F7H EOX (End of Exclusive)

* The amount of data that can be transmitted at once is fixed for each type of data. Data that does not have the specified starting address and data size will not be received. Refer to the explanation in 3. Bulk Dump. * There must be an interval of at least 40 ms between each exclusive message that is sent. * Also, you must leave an interval of at least 500 ms after transmitting one set of bulk dump data.

❍ V-LINK OFF

Transmitted when exiting V-LINK mode.

Status Data byte Status F0H 41H,10H,00H,51H,12H, F7H 10H,00H,00H,00H,70H

Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID (For the PCR-A30, fixed at 10H) 00H 51H Model ID (V-LINK) 12H Command ID (DT1) 10H 00H 00H Address 00H V-LINK OFF 51H Checksum F7H EOX (End of Exclusive)

❍Identity reply

Page 5 of the Roland PCR-A30 user manual — X X X X X X
Pagina 5 · klik om te vergroten
Pagina 5

fig.midi-chart.e

USB AUDIO INTERFACE / MIDI KEYBOARD CONTROLLER Model PCR-A30 Versie : 1.00 MIDI Implementatiekaart

Functie...

OMNI ON/OFF, MONO, POLY

O (9n v=1–127) O (9n v=0)

O O

O

O

O (0–127) **************

: True Number

O

O

: Song Position : Song Select : Tune Request

O O (0–127) O

: Clock : Commands

O O

: All Sound Off : Reset All Controllers : Local On/Off : All Notes Off : Active Sensing : System Reset

O *1 (120) O *1 (121) O O *1 (123) O O

X

* 1 When PANIC is transmitted.

Mode 1OMNI ON, POLY Mode 3 : OMNI OFF, POLY
Mode 2OMNI ON, MONO Mode 4 : OMNI OFF, MONO
OJa X : Nee
Show 19 more labels / short text on this page
Verzonden Herkend Opmerkingen · Basic Channel · Default Changed · Default Messages Altered · Mode 3 · Mode · ************** · True Voice · ************** · Velocity · After Touch · Key's Channel's · Pitch Bend · Control Change · Program Change · System Exclusive · System Common · System Real Time · Aux Messages

Vraag stellen over de Roland PCR-A30

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Roland PCR-A30

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Roland PCR-A30 handleiding-pdf

112 pagina's·4.3 MB·Geluid·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…