In addition to the channel voice messages that can be transmitted in each mode, the PCR-A30 lets you assign any channel voice message to any controller and transmit it.
❍Identity request message
Status Data byte Status F0H 7EH, dev, 06H, 01H F7H
Status 2nd byte 3rd byte 9nH kkH 00H
Byte Explanation F0H Exclusive status 7EH ID number (Universal non-realtime system exclusive message) dev Device ID (10 or 7FH (Broadcast)) 06H Sub ID #1 (PCR-A30) 01H Sub ID #1 (PCR-A30) F7H EOX (End of Exclusive)
n = MIDI channel number:0H – FH (Ch.1 – 16) kk = note number: 00H – 7FH (0 – 127)
* Transmitted when you release a key in Play mode.
Status 2nd byte 3rd byte 9nH kkH vvH
The PCR-A30 can use Bulk Dump (p. 104) to transfer its internal memory set data (p. 88).
n = MIDI channel number: 0H – FH (Ch.1 – 16) kk = note number: 00H – 7FH (0 – 127) vv = note on velocity: 01H – 7FH (1 – 127)
❍Data Set 1 (DT1)
These messages transmit the actual data, and are used to transfer data settings to a device.
* Transmitted when you push a key in Play mode.
Status Data byte Status F0H 41H, 10H, 00H, 62H, 12H, aaH, ddH, ...eeH, sum F7H
Status 2nd byte 3rd byte AnH kkH vvH
Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID (For the PCR-A30, fixed at 10H) 00H Model ID #1 (PCR-A30) 62H Model ID #1 (PCR-A30) 12H Command ID (RQ1) aaH Address ddH Data : : : eeH Data sum Checksum F7H EOX (End of Exclusive)
n = MIDI channel number: 0H – FH (Ch.1 – 16) kk = note number: 00H – 7FH (0 – 127) vv = key pressure: 00H – 7FH (0 – 127)
Status 2nd byte 3rd byte BnH ccH vvH
n = MIDI channel number: 0H – FH (Ch.1 – 16) cc = controller number: 00H – 77H vv = control value: 00H – 7FH
❍Bank Select (Controller number 0, 32)
Status 2nd byte 3rd byte BnH 00H mmH BnH 20H llH
* The amount of data that can be transmitted at once is fixed for each type of data. Data that does not have the specified starting address and data size will not be received. Refer to the explanation in 3. Bulk Dump (p. 104). * There must be an interval of at least 40 ms between each exclusive message that is sent. * Also, you must leave an interval of at least 500 ms after transmitting one set of bulk dump data.
n = MIDI channel number: 0H – FH (Ch.1 – 16) mm = Bank number MSB: 00H – 7FH ll = Bank number LSB: 00H – 7FH
* Transmitted in Bank mode.
❍Modulation (Controller number 1)
Status 2nd byte 3rd byte BnH 01H vvH
n = MIDI channel number:0H – FH (Ch.1 – 16) vv = Modulation depth:00H – 7FH (0 – 127)
* Transmitted by upward/downward operation of the BENDER lever in Play mode.

Status 2nd byte CnH ppH
On the PCR-A30 you can assign the following system common messages to any controller and transmit them.
n = MIDI channel number: 0H – FH (Ch.1 – 16) pp = Program number: 00H – 7FH (prog. 1 – prog. 128)
Status 2nd byte F1H mmH
* Transmitted in Program change mode.
mm = Message type/value
Status 2nd byte DnH vvH
Status 2nd byte 3rd byte F2H mmH llH
n = MIDI channel number: 0H – FH (Ch.1 – 16) vv = Channel pressure: 00H – 7FH (0 – 127)
Status 2nd byte 3rd byte EnH llH mmH
Status 2nd byte F3H mmH
n = MIDI channel number: 0H – FH (Ch.1 – 16) mm, ll = Pitch Bend value: 00 00H – 40 00H – 7FH 7FH (-8192 – 0 – +8191) * Transmitted by rightward/leftward operation of the BENDER lever in Play mode.
In addition to the channel mode messages that can be transmitted in Panic mode, the PCR-A30 lets you assign any channel voice message to any controller and transmit it.
In addition to the Active Sensing messages that are transmitted constantly, the PCR-A30 allows you to assign the following system realtime messages (other than Active Sensing) to any controller and transmit them.
Status 2nd byte 3rd byte BnH ccH vvH
n = MIDI channel number: 0H – FH (Ch.1 – 16) cc = controller number: 78H – 7FH vv = control value: 00H – 7FH
* Transmitted if the System setting F8 CLOCK is ON.
❍All sounds off (Controller number 120)
Status 2nd byte 3rd byte BnH 78H 00H
* Transmitted in Panic mode.
❍Reset all controllers (Controller number 121)
Status 2nd byte 3rd byte BnH 79H 00H
* Transmitted in Panic mode.
❍All notes off (Controller number 123)
* Transmitted at intervals of approximately 250 ms. * Cannot be assigned to a controller.
Status 2nd byte 3rd byte BnH 7BH 00H
* Transmitted in Panic mode.

❍Sender Model Name
The PCR-A30 is able to transmit the following exclusive messages: exclusive messages assigned to the controllers, Identity Reply, V-LINK messages, and Bulk Dump.
Transmitted when entering V-LINK mode. Status Data byte Status F0H 41H,10H,00H,51H,12H, F7H 10H,71H,00H,45H,44H,49H,52H,4FH,4CH, 20H,50H,43H,52H,00H,3BH
Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID (For the PCR-A30, fixed at 10H) 00H 51H Model ID (V-LINK) 12H Command ID (DT1) aaH Address 10H 71H 00H Data 45H 44H 49H Model name (EDIROL PCR) 52H 4FH 4CH : 20H 50H 43H : 52H 00H : 3BH Checksum F7H EOX (End of Exclusive)
This message will be transmitted when an Identity Request message is received.
Status Data byte Status F0H 7EH,10H,06H,02H,41H,62H,01H, F7H 00H,00H,01H,01H,00H,00H
Byte Explanation F0H Exclusive status 7EH ID number (Universal non-realtime message) 10H Device ID (For the PCR-A30, fixed at 10H) 06H Sub ID #1 (General Information) 02H Sub ID #1 (Identity Reply) 41H ID number (Roland) 62H 01H Device family code 00H 00H Device family number code 01H 01H Software revision level 00H 00H : F7H EOX (End of Exclusive)
Transmitted when you execute Bulk TX in the Bulk mode. Status Data byte Status F0H 41H, 10H, 00H, 62H, 12H, aaH, ddH, ...eeH, sum F7H
Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID 00H Model ID #1 (PCR-A30) 62H Model ID #1 (PCR-A30) 12H Command ID (RQ1) aaH Address ddH Data : : : eeH Data sum Checksum F7H EOX (End of Exclusive)
Transmitted when entering V-LINK mode.
Status Data byte Status F0H 41H,10H,00H,51H,12H, F7H 10H,00H,00H,01H,0FH,0FH,51H
Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID (For the PCR-A30, fixed at 10H) 00H 51H Model ID (V-LINK) 12H Command ID (DT1) 10H 00H 00H Address 01H V-LINK ON 0FH Clip Control Rx. MIDI Ch. (16ch) 0FH Color Control Rx. MIDI Ch. (16ch) 51H Checksum F7H EOX (End of Exclusive)
* The amount of data that can be transmitted at once is fixed for each type of data. Data that does not have the specified starting address and data size will not be received. Refer to the explanation in 3. Bulk Dump. * There must be an interval of at least 40 ms between each exclusive message that is sent. * Also, you must leave an interval of at least 500 ms after transmitting one set of bulk dump data.
Transmitted when exiting V-LINK mode.
Status Data byte Status F0H 41H,10H,00H,51H,12H, F7H 10H,00H,00H,00H,70H
Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID (For the PCR-A30, fixed at 10H) 00H 51H Model ID (V-LINK) 12H Command ID (DT1) 10H 00H 00H Address 00H V-LINK OFF 51H Checksum F7H EOX (End of Exclusive)
❍Identity reply

fig.midi-chart.e
USB AUDIO INTERFACE / MIDI KEYBOARD CONTROLLER Model PCR-A30 Versie : 1.00 MIDI Implementatiekaart
Functie...
O (9n v=1–127) O (9n v=0)
O
O
O (0–127) **************
: True Number
O
: Song Position : Song Select : Tune Request
: Clock : Commands
: All Sound Off : Reset All Controllers : Local On/Off : All Notes Off : Active Sensing : System Reset
O *1 (120) O *1 (121) O O *1 (123) O O
* 1 When PANIC is transmitted.