L-398A
Operating Instructions



This manual uses the following safety labels for WARNING and CAUTION that you must follow.
Indicates hazards or unsafe practices that can re- sult in severe personal injury or death.
Indicates hazards or unsafe practices that can re- sult in the personal injury or damage to your L-398A exposure meter.


Nearly all photographic subjects combine complex variations of strongly reflecting surfaces (high reflectivity) and weakly reflecting surfaces (low reflectivity). These variations delicately influence expo- sure determination and to which portion the exposure is set becomes a vital factor that considerably affects the appearance of the finished photograph. Although risk of failure can be minimized by taking maximum and minimum readings of all portions of the subject, then averaging the values, such an approach is both time consuming and tedious. The Studio Deluxe Ⅲ is the answer to this problem. 1. Optimum exposure meter for incident light measuring method (also applicable for reflected light method.) 2. Freely rotatable light sensor section for very easily performed measurements. 3. Meter stopper mechanism allows operation while hand is released from meter. 4. Meter release mechanism is also included which allows the needle to deflect freely. This provides greater convenience when deter- mining light balance. 5. Memo pointer enables easier light balance setting. 6. Lumisphere detects the same light as strikes the subject. Since subjects are normally 3-dimensional, according to the lighting con- ditions, brighter surfaces (highlights) and darker surfaces (shad- ows) are produced (illumination contrast). The Studio Deluxe Ⅲ mechanism automatically takes into account the strength of light from all directions, causing the meter to indicate a value appli- cable to photography. It is thus most convenient for determining typical exposures. 7. After combining film sensitivity and shutter speed, direct reading slides (optional) can be used for directly determining the aperture valve. 8. AMORPHOUS PHOTOSENSOR is employed as light sensing element, eliminating need for battery. 9. Wide selection of available accessories allows numerous photo- graphic techniques to be enjoyed.

MAIN LIGHT
AMORPHOUS PHOTOSENSOR
LUMISPHERE
FILL-IN LIGHT
5.6 INCIDENT
LIGHT
MICROAMMETER
MAGNET
Caution:

Analog exposure meter for ambient light
Incident light and reflected light
ISO 6 to 12,000 (in 1/3 step)
60 sec. to 1/8000 sec. (in full step)
F0.7 to F128 (in 1/3 step)
8, 18, 24, 64, 128
EV1 to 20 (in 1/3 step)
0℃ to 40℃
-20℃ to 60℃
112(H) × 58(W) × 34(D) mm
Approx. 190g


Meter · scale · Dial scale

High (H) slide@2
Optional Accessories (sold separately) Direct reading slides.
No. 5
Total of 11 direct reading slides (set of 11 slides in case).
Lumisphereq · Lumidisc@3 · Lumigrid@4

1.Stopper Button Operation If the stopper button !3 is pressed when the stopper button mark !9 is set to ○, the meter needle !8 deflects according to brightness. Then when the button is released, the needle remains fixed at the indicated position. By holding the stopper button de- pressed and turning it clockwise so that the mark position becomes ○, the needle is released. At this time, the meter will deflect freely even if the stopper button is released. To fix the needle, turn the stopper button counter-clock- wise to where the mark is posi- tioned ○.
H
E
1/SEC
・
F
C I N E
S
H
E
1/SEC
F
・
C I N E
・
2.Zero Position Check and Adjustment With stopper button in released ○ position, cover light sensor with hand or black cloth to completely block light. Check that meter needle !8 correctly indicates zero position. If the indication deviates from zero, while observing meter indication, use a coin or similar tool to turn the rear zero adjust screw @1 and adjust for zero indi- cation.
D
H
E
1/SEC
F
C I N E

Dial 3.Memo Pointer Operation Rotate both Dial Ring !6 and dial of Memo Pointer !7 to align with Needle !8 position or desirable setting position. ※ See page 11 for actual use.
Memo Pointer

Incident Light Measurement 1. Lumisphere a. Mount Lumisphere q to light sensor w. To mount, align white dots of Lumisphere frame and light sensor, then turn Lumisphere carefully clockwise (approx. 45 deg.)to secure.
b. Set film sensitivity knob @0 to sensitivity value of employed film. Set ISO value to right side ISO mark !1. Photo shows setting for ISO 100.
c. From position where subject is to be measured, point Lumisphere q in direction of camera. (Light sensor w can be turned freely.)

d. Hold meter erect and press stopper button !3. Meter needle !8 deflects according to brightness. When the stopper button is re- leased, the meter needle becomes fixed at the deflected position. If the location is excessively bright and the meter needle deflects beyond scale, insert the High slide @2.


e. Read the footcandle scale e of the meter needle. f. Transfer footcandle value to the dial scale u. Rotate the dial ring !6 and set the ▲ scale mark i. If the High slide @2 has been inserted, set the mark o. ▲ H

g. At this time, the shutter speed scale !4 and aperture scale !5 combination becomes the correct exposure. Example:With High slide inserted, meter indicates 80 footcancles.
At ISO 100, the proper exposure becomes 1/250 sec at F/ 5.6, 1/30 sec at F/16 and 1 sec at F/90. h. By changing ISO setting, the set combination of shutter speed and aperture scale is automatically altered to the appropriate one corresponding to the changed ISO value.
4 6 128 16
Shutter speed and aperture scale
0.7F
※ Film sensitivity intermediate
1k 1.2k
2.5k 2k

2.Lumidisc Employ for illumination contrast adjustment and illuminance measure- ment.
640 2 320 1 or 2 : 1 =
Main light · Fill-in light

If meter deflects beyond scale, insert High slide @2, then multiply footcandle indication by 32. Example:80 x 32 = 2560 footcandles
Reflected Light Measurement 1.Lumigrid a. Mount Lumigrid to light sensor w in the same man- ner as Lumisphere q. (See P.8) b. Set sensitivity value of em- ployed film. Setting is per- formed in the same manner as for incident light measure- ment. (See P.8) c. From camera position, point Lumigrid @4 directly toward part of subject to be mea- sured. d. In case of measuring narrow areas, as close as possible to the subject, measure re- flected light from main point of subject. Use adequate care at this time that meter shadow etc. does not interfere.

e. Press stopper button !3, and read meter scale footcandle indica- tion e. However, since footcandles are units of incident light only, this value becomes simply a reference. f. Transfer indicated value to dial scale u. Rotate the dial ring !6 and set mark o. g. At this time, shutter speed scale !4 and aperture scale !5 combi- nation becomes the correct exposure. Note:Do not employ slides for reflected light measurement. ※ More accurate results can be obtained for reflected light mea-
surement by using a Gray card (optional accessory).

Reading this exposure value to perform setting becomes conve- nient for cameras which employ a light value system of shutter and aperture combination. a. Read meter needle !8 foot- candle indication e. b. Transfer this number to the dial scale u. Rotate dial ring !6 and set ▲ scale mark i. If the High slide is inserted, set the mark o. c. EV value indicated by EV mark y becomes the correct exposure value.
D
H
E
1/SEC
C I N E
F
▲ H
2.Employing Cine Scale Incident and reflected light mea- surements during cine photogra- phy are performed in the same manner as described previously. However, since the cine scale !2 numerals correspond to cine cam- era film speed, read the aperture scale !5 indication that pertains to the employed film speed.

360×R θ R = Frames exposed in 1 second T = Exposure time = Shutter angle θ
3.Using Exposure Multipliers (-2, -1, +1, +2) Exposure multiplier indications are provided at both sides of the and ▲ marks of the dial scale. Use the -1 or -2 mark when desiring to cut the exposure to 1/2 of 1/4 and +1 or +2 mark to multiply the expo- sure by 2 or 4. Set the appropriate mark, instead of the or ▲ mark, to the dial scale value.
▲ H
+
+
H
E
+
1/SEC
+

1.Direct Reading Slides A total of 11 slides are available, all of which may be used together with the Lumisphere and Lumidisc. (Note that they cannot be used with Limigrid.) The High slide, as mentioned previously, is employed for varying the measuring range in 2 steps (high and low illumination), however, it can also be used for direct reading.
Slide No.
HIGH slide is standard accessory and not included in the slide set, though there is a space to store it in the case of slide set.
Shutter

When photographing, select slide from the above table according to film sensitivity and shutter speed. Insert slide and perform measure- ment in the same manner as for incident light. Read directly the ap- erture value r indicated by the meter needle !8.
tate the dial when employing direct reading slides, setting becomes extremely fast and convenient.

Since the Studio Deluxe Ⅲ is a high precision instrument, use ample care in regard to the following points.
repellants are located (metal cabinets, clothing dressers, etc.). • Keep Lumisphere and Lumidisc clean and protect from dust and
scratches. • Wipe Lumisphere and Lumidisc with a dry soft cloth if it becomes
dirty. Never use organic cleaners (like Thinner or benzene).



TOKYO 178-8686 JAPAN
TEL:+81(0)3-3978-2335 FAX:+81(0)3-3978-5229
http://www.sekonic.co.jp/English