Sekonic L-398A

24 pagina's·1.1 MB·Lichtmeter·PDF·EN
Sekonic L-398A
Inhoudsopgave 71 secties STUDIO DELUXE Ⅲ · L-398A · Operating Instructions · SAFETY PRECAUTION · … TonenVerbergen
STUDIO DELUXE Ⅲp.1L-398Ap.1Operating Instructionsp.1SAFETY PRECAUTIONp.3WARNINGp.3CAUTIONp.3CONTENTSp.41. Features …………………………………………………… 1p.42. Specifications ……………………………………………… 3p.43. Part Designations …………………………………………… 4p.44. Accessories ………………………………………………… 5p.45. Basic Operation of Meter Unit …………………………… 6p.41. Stopper Button Operation …………………………… 6p.42. Zero Position Check and Adjustment ……………… 6p.43. Memo Pointer Operation ……………………………… 7p.4Incident Light Measurement ……………………………… 8p.41. Lumisphere …………………………………………… 8p.42. Lumidisc …………………………………………… 11p.4Reflected Light Measurement ………………………… 12p.41. Lumigrid ……………………………………………… 12p.4Other Operations ………………………………………… 14p.41. Exposure Value (EV numbers) Readout ………… 14p.42. Employing Cine Scale ……………………………… 14p.43. Using Exposure Multipliers (-2, -1, +1, +2) ……… 15p.47. Optional Accessories Operation ……………………… 16p.41. Direct Reading Slides ……………………………… 16p.42. Direct Reading Slide Application ………………… 17p.48. Handling Cautions ……………………………………… 18p.41. FEATURESp.5BACK LIGHTp.6MAIN LIGHTp.6AMORPHOUS PHOTOSENSORp.6LUMISPHEREp.6FILL-IN LIGHTp.65.6 INCIDENTp.6LIGHTp.6MICROAMMETERp.6MAGNETp.6Caution:p.62. SPECIFICATIONSp.73. PART DESIGNATIONSp.8Frontp.84. Accessoriesp.9HIGHp.95. BASIC OPERATION OF METER UNITp.101/SECp.10C I N Ep.10※ Meter scale intermediate valuesp.14※ Intermediate values forp.14Shutter speed and aperture scalep.140.7Fp.14※ Film sensitivity intermediatep.14valuesp.14candles. Illumination contrast ratio becomes;p.15640 2 320 1 or 2 : 1 =p.152560 x 10.76 = 27545.6 luxp.16@4p.16▲ Hp.17Other Operations 1.Exposure Value (EV number) Readoutp.18Shutter angle and exposure calculation:p.19T =p.197. Optional Accessories Operationp.20speed 1p.202.Direct Reading Slide Applicationp.21※ Since it is not necessary to ro-p.218. HANDLING CAUTIONSp.227-24-14, OIZUMI-GAKUEN-CHO, NERIMA-KU,p.24TOKYO 178-8686 JAPANp.24TEL:+81(0)3-3978-2335 FAX:+81(0)3-3978-5229p.24http://www.sekonic.co.jp/Englishp.24JG1297521p.24
Page 1 of the Sekonic L-398A user manual — STUDIO DELUXE Ⅲ
Pagina 1 · klik om te vergroten
Pagina 1

STUDIO DELUXE Ⅲ

L-398A

Operating Instructions

Page 2 of the Sekonic L-398A user manual — STUDIO DELUXE Ⅲ
Pagina 2 · klik om te vergroten
Pagina 2
Page 2 of the Sekonic L-398A user manual — STUDIO DELUXE Ⅲ
Page 3 of the Sekonic L-398A user manual — CAUTION
Pagina 3 · klik om te vergroten
Pagina 3

SAFETY PRECAUTION

This manual uses the following safety labels for WARNING and CAUTION that you must follow.

WARNING

Indicates hazards or unsafe practices that can re- sult in severe personal injury or death.

CAUTION

Indicates hazards or unsafe practices that can re- sult in the personal injury or damage to your L-398A exposure meter.

WARNING

  • Keep Lumisphere, Lumidisc, Lumigrid or Highslide out of reach of young children, as swallowing such objects can cause suffocation.
  • Please place in a location where an infant cannot reach and accidentally get the strap wrapped around his or her neck. There is a danger of strangulation.

CAUTION

  • This L-398A has a powerful magnet. Do not place it close to the following materials, otherwise the data stored may be damaged or the products may malfunction: Cash cards, floppy disc, other magnetic cards, TV Set, CRT display or LCD, and other apparatus sensitive to magnetic fields.
Page 4 of the Sekonic L-398A user manual — Inhoudsopgave
Pagina 4 · Inhoud
Inhoud

Inhoud

STUDIO DELUXE Ⅲp.1L-398Ap.1Operating Instructionsp.1SAFETY PRECAUTIONp.3WARNINGp.3CAUTIONp.3CONTENTSp.41. Features …………………………………………………… 1p.42. Specifications ……………………………………………… 3p.43. Part Designations …………………………………………… 4p.44. Accessories ………………………………………………… 5p.45. Basic Operation of Meter Unit …………………………… 6p.41. Stopper Button Operation …………………………… 6p.42. Zero Position Check and Adjustment ……………… 6p.43. Memo Pointer Operation ……………………………… 7p.4Incident Light Measurement ……………………………… 8p.41. Lumisphere …………………………………………… 8p.42. Lumidisc …………………………………………… 11p.4Reflected Light Measurement ………………………… 12p.41. Lumigrid ……………………………………………… 12p.4Other Operations ………………………………………… 14p.41. Exposure Value (EV numbers) Readout ………… 14p.42. Employing Cine Scale ……………………………… 14p.43. Using Exposure Multipliers (-2, -1, +1, +2) ……… 15p.47. Optional Accessories Operation ……………………… 16p.41. Direct Reading Slides ……………………………… 16p.42. Direct Reading Slide Application ………………… 17p.48. Handling Cautions ……………………………………… 18p.41. FEATURESp.5BACK LIGHTp.6MAIN LIGHTp.6AMORPHOUS PHOTOSENSORp.6LUMISPHEREp.6FILL-IN LIGHTp.65.6 INCIDENTp.6LIGHTp.6MICROAMMETERp.6MAGNETp.6Caution:p.62. SPECIFICATIONSp.73. PART DESIGNATIONSp.8Frontp.84. Accessoriesp.9HIGHp.95. BASIC OPERATION OF METER UNITp.101/SECp.10C I N Ep.10※ Meter scale intermediate valuesp.14※ Intermediate values forp.14Shutter speed and aperture scalep.140.7Fp.14※ Film sensitivity intermediatep.14valuesp.14candles. Illumination contrast ratio becomes;p.15640 2 320 1 or 2 : 1 =p.152560 x 10.76 = 27545.6 luxp.16@4p.16▲ Hp.17Other Operations 1.Exposure Value (EV number) Readoutp.18Shutter angle and exposure calculation:p.19T =p.197. Optional Accessories Operationp.20speed 1p.202.Direct Reading Slide Applicationp.21※ Since it is not necessary to ro-p.218. HANDLING CAUTIONSp.227-24-14, OIZUMI-GAKUEN-CHO, NERIMA-KU,p.24TOKYO 178-8686 JAPANp.24TEL:+81(0)3-3978-2335 FAX:+81(0)3-3978-5229p.24http://www.sekonic.co.jp/Englishp.24JG1297521p.24
Page 5 of the Sekonic L-398A user manual — 1. FEATURES
Pagina 5 · klik om te vergroten
Pagina 5

1. FEATURES

Nearly all photographic subjects combine complex variations of strongly reflecting surfaces (high reflectivity) and weakly reflecting surfaces (low reflectivity). These variations delicately influence expo- sure determination and to which portion the exposure is set becomes a vital factor that considerably affects the appearance of the finished photograph. Although risk of failure can be minimized by taking maximum and minimum readings of all portions of the subject, then averaging the values, such an approach is both time consuming and tedious. The Studio Deluxe Ⅲ is the answer to this problem. 1. Optimum exposure meter for incident light measuring method (also applicable for reflected light method.) 2. Freely rotatable light sensor section for very easily performed measurements. 3. Meter stopper mechanism allows operation while hand is released from meter. 4. Meter release mechanism is also included which allows the needle to deflect freely. This provides greater convenience when deter- mining light balance. 5. Memo pointer enables easier light balance setting. 6. Lumisphere detects the same light as strikes the subject. Since subjects are normally 3-dimensional, according to the lighting con- ditions, brighter surfaces (highlights) and darker surfaces (shad- ows) are produced (illumination contrast). The Studio Deluxe Ⅲ mechanism automatically takes into account the strength of light from all directions, causing the meter to indicate a value appli- cable to photography. It is thus most convenient for determining typical exposures. 7. After combining film sensitivity and shutter speed, direct reading slides (optional) can be used for directly determining the aperture valve. 8. AMORPHOUS PHOTOSENSOR is employed as light sensing element, eliminating need for battery. 9. Wide selection of available accessories allows numerous photo- graphic techniques to be enjoyed.

Page 6 of the Sekonic L-398A user manual — BACK LIGHT
Pagina 6 · klik om te vergroten
Pagina 6

1. FEATURES

BACK LIGHT

MAIN LIGHT

AMORPHOUS PHOTOSENSOR

LUMISPHERE

FILL-IN LIGHT

5.6 INCIDENT

LIGHT

MICROAMMETER

MAGNET

Caution:

  • Your L-398A has a powerful magnet. Do not place your L-398A close to the following materials, otherwise the data stored may be damaged or the product may malfunction: Cash cards and other magnetic cards, floppy disk, TV Set, CRT display, and other apparatus sensitive to magnetic fields.
Page 7 of the Sekonic L-398A user manual — 2. SPECIFICATIONS
Pagina 7 · klik om te vergroten
Pagina 7

2. SPECIFICATIONS

Analog exposure meter for ambient light

Incident light and reflected light

Incident lightLumisphere and Lumidisc
Reflected lightLumigrid (30 deg. of light
Incident lightEV4 to 17
Reflected lightEV9 to 17

ISO 6 to 12,000 (in 1/3 step)

60 sec. to 1/8000 sec. (in full step)

F0.7 to F128 (in 1/3 step)

8, 18, 24, 64, 128

EV1 to 20 (in 1/3 step)

Incident lightC=340 (Lumisphere),
Reflected lightK=12.5

0℃ to 40℃

-20℃ to 60℃

112(H) × 58(W) × 34(D) mm

Approx. 190g

Show 16 more labels / short text on this page
Type · Light receiving method · Light receiving section · receiving angle ) · Measuring range · Film speed · Shutter speed · Aperture value · Cine speed (f/s) · EV (Exposure Value) · Calibration Constant · C=250 (Lumidisc) · Operating temperature range · Storage temperature range · Dimensions · Weight
Page 8 of the Sekonic L-398A user manual — Front
Pagina 8 · klik om te vergroten
Pagina 8

3. PART DESIGNATIONS

Front

Sekonic L-398A — Front diagram (page 8)
Afb. 1 · Front

Meter · scale · Dial scale

Page 9 of the Sekonic L-398A user manual — Warning
Pagina 9 · klik om te vergroten
Pagina 9

4. Accessories

High (H) slide@2

HIGH

Optional Accessories (sold separately) Direct reading slides.

No. 5

Total of 11 direct reading slides (set of 11 slides in case).

Warning

  • Keep Lumisphere, Lumidisc, Lumigrid or High-slide out of reach of young children, as swallowing such objects can cause suffocation.

Lumisphereq · Lumidisc@3 · Lumigrid@4

Page 10 of the Sekonic L-398A user manual — L-398A
Pagina 10 · klik om te vergroten
Pagina 10

5. BASIC OPERATION OF METER UNIT

1.Stopper Button Operation If the stopper button !3 is pressed when the stopper button mark !9 is set to ○, the meter needle !8 deflects according to brightness. Then when the button is released, the needle remains fixed at the indicated position. By holding the stopper button de- pressed and turning it clockwise so that the mark position becomes ○, the needle is released. At this time, the meter will deflect freely even if the stopper button is released. To fix the needle, turn the stopper button counter-clock- wise to where the mark is posi- tioned ○.

S

H

E

1/SEC

・

F

C I N E

S

H

E

1/SEC

F

・

C I N E

・

2.Zero Position Check and Adjustment With stopper button in released ○ position, cover light sensor with hand or black cloth to completely block light. Check that meter needle !8 correctly indicates zero position. If the indication deviates from zero, while observing meter indication, use a coin or similar tool to turn the rear zero adjust screw @1 and adjust for zero indi- cation.

・

L-398A

D

H

E

1/SEC

F

C I N E

Show 34 more labels / short text on this page
e · + · + · ・ · ・ · + · ・ · ・ · + · e · + · + · + · ・ · ・ · ・ · ・ · + · Black cloth · St · ud · io · el · ux · e · Ⅲ · + · + · + · ・ · ・ · ・ · ・ · +
Page 11 of the Sekonic L-398A user manual — 5. BASIC OPERATION OF METER UNIT
Pagina 11 · klik om te vergroten
Pagina 11

5. BASIC OPERATION OF METER UNIT

Dial 3.Memo Pointer Operation Rotate both Dial Ring !6 and dial of Memo Pointer !7 to align with Needle !8 position or desirable setting position. ※ See page 11 for actual use.

Memo Pointer

Page 12 of the Sekonic L-398A user manual — C I N E
Pagina 12 · klik om te vergroten
Pagina 12

Incident Light Measurement 1. Lumisphere a. Mount Lumisphere q to light sensor w. To mount, align white dots of Lumisphere frame and light sensor, then turn Lumisphere carefully clockwise (approx. 45 deg.)to secure.

b. Set film sensitivity knob @0 to sensitivity value of employed film. Set ISO value to right side ISO mark !1. Photo shows setting for ISO 100.

C I N E

c. From position where subject is to be measured, point Lumisphere q in direction of camera. (Light sensor w can be turned freely.)

Page 13 of the Sekonic L-398A user manual — 5. BASIC OPERATION OF METER UNIT
Pagina 13 · klik om te vergroten
Pagina 13

d. Hold meter erect and press stopper button !3. Meter needle !8 deflects according to brightness. When the stopper button is re- leased, the meter needle becomes fixed at the deflected position. If the location is excessively bright and the meter needle deflects beyond scale, insert the High slide @2.

Sekonic L-398A — 5. BASIC OPERATION OF METER UNIT diagram (page 13)
Afb. 2
Sekonic L-398A — 5. BASIC OPERATION OF METER UNIT diagram (page 13)
Afb. 3

e. Read the footcandle scale e of the meter needle. f. Transfer footcandle value to the dial scale u. Rotate the dial ring !6 and set the ▲ scale mark i. If the High slide @2 has been inserted, set the mark o. ▲ H

Page 14 of the Sekonic L-398A user manual — values
Pagina 14 · klik om te vergroten
Pagina 14

g. At this time, the shutter speed scale !4 and aperture scale !5 combination becomes the correct exposure. Example:With High slide inserted, meter indicates 80 footcancles.

At ISO 100, the proper exposure becomes 1/250 sec at F/ 5.6, 1/30 sec at F/16 and 1 sec at F/90. h. By changing ISO setting, the set combination of shutter speed and aperture scale is automatically altered to the appropriate one corresponding to the changed ISO value.

※ Meter scale intermediate values

4 6 128 16

※ Intermediate values for

1/SEC

Shutter speed and aperture scale

0.7F

※ Film sensitivity intermediate

1k 1.2k

2.5k 2k

values

Show 6 more labels / short text on this page
Footcandles · 100 125 · 200 250 · 128 112 110 · 4k 5k · 250 320
Page 15 of the Sekonic L-398A user manual — candles. Illumination contrast ratio becomes;
Pagina 15 · klik om te vergroten
Pagina 15

2.Lumidisc Employ for illumination contrast adjustment and illuminance measure- ment.

  • Contrast measurement a. Mount Lumidisc @3 to light sensor w . Install in the same manner as Lumisphere. (See P. 8) b. Hold meter at subject position and point Lumidisc @3 directly toward center of main light. c. Press stopper button !3 and read meter scale footcandle indication e . d. Turn the memo pointer dial and set the memo pointer !7 at the footcandle value the needle points to. e. In the same manner, measure the fill-in light. In this case, take care that light from main source does not enter sensor. f. Read a difference between the footcandle value the memo pointer is set (see above d) and the one for fillin light (= needle position). Ratio between main and fill-in light footcandles becomes the contrast ratio. Example:With main light at 640 footcandles, fill-in light reads 320 foot-

candles. Illumination contrast ratio becomes;

640 2 320 1 or 2 : 1 =

Main light · Fill-in light

Page 16 of the Sekonic L-398A user manual — @4
Pagina 16 · klik om te vergroten
Pagina 16
6. STANDARD ACCESSORY OPERATION • Illuminance (Lux) measurement a. Mount Limidisc @3 to light sensor w in the same manner as Lumisphere. b. Place Lumidisc @3 parallel with the light source. c. Press stopper button !3 and read meter scale footcandle indication e . d. Multiply this value by 10.76 to obtain lux. Example:80 x 10.76 = 860.8 lux

If meter deflects beyond scale, insert High slide @2, then multiply footcandle indication by 32. Example:80 x 32 = 2560 footcandles

2560 x 10.76 = 27545.6 lux

Reflected Light Measurement 1.Lumigrid a. Mount Lumigrid to light sensor w in the same man- ner as Lumisphere q. (See P.8) b. Set sensitivity value of em- ployed film. Setting is per- formed in the same manner as for incident light measure- ment. (See P.8) c. From camera position, point Lumigrid @4 directly toward part of subject to be mea- sured. d. In case of measuring narrow areas, as close as possible to the subject, measure re- flected light from main point of subject. Use adequate care at this time that meter shadow etc. does not interfere.

@4

Page 17 of the Sekonic L-398A user manual — ▲ H
Pagina 17 · klik om te vergroten
Pagina 17

e. Press stopper button !3, and read meter scale footcandle indica- tion e. However, since footcandles are units of incident light only, this value becomes simply a reference. f. Transfer indicated value to dial scale u. Rotate the dial ring !6 and set mark o. g. At this time, shutter speed scale !4 and aperture scale !5 combi- nation becomes the correct exposure. Note:Do not employ slides for reflected light measurement. ※ More accurate results can be obtained for reflected light mea-

▲ H

surement by using a Gray card (optional accessory).

Page 18 of the Sekonic L-398A user manual — C I N E
Pagina 18 · klik om te vergroten
Pagina 18

Other Operations 1.Exposure Value (EV number) Readout

Reading this exposure value to perform setting becomes conve- nient for cameras which employ a light value system of shutter and aperture combination. a. Read meter needle !8 foot- candle indication e. b. Transfer this number to the dial scale u. Rotate dial ring !6 and set ▲ scale mark i. If the High slide is inserted, set the mark o. c. EV value indicated by EV mark y becomes the correct exposure value.

L-398A

D

H

E

1/SEC

C I N E

F

▲ H

2.Employing Cine Scale Incident and reflected light mea- surements during cine photogra- phy are performed in the same manner as described previously. However, since the cine scale !2 numerals correspond to cine cam- era film speed, read the aperture scale !5 indication that pertains to the employed film speed.

C I N E

Show 15 more labels / short text on this page
ud · io · el · ux · e · St · Ⅲ · + · + · + · ・ · ・ · ・ · ・ · +
Page 19 of the Sekonic L-398A user manual — ▲ H
Pagina 19 · klik om te vergroten
Pagina 19

Shutter angle and exposure calculation:

360×R θ R = Frames exposed in 1 second T = Exposure time = Shutter angle θ

T =

3.Using Exposure Multipliers (-2, -1, +1, +2) Exposure multiplier indications are provided at both sides of the and ▲ marks of the dial scale. Use the -1 or -2 mark when desiring to cut the exposure to 1/2 of 1/4 and +1 or +2 mark to multiply the expo- sure by 2 or 4. Set the appropriate mark, instead of the or ▲ mark, to the dial scale value.

▲ H

▲ H

+

+

H

E

+

1/SEC

+

Show 8 more labels / short text on this page
+2 · +1 · +1 · +2 · ・ · ・ · ・ · ・
Page 20 of the Sekonic L-398A user manual — HIGH
Pagina 20 · klik om te vergroten
Pagina 20

7. Optional Accessories Operation

1.Direct Reading Slides A total of 11 slides are available, all of which may be used together with the Lumisphere and Lumidisc. (Note that they cannot be used with Limigrid.) The High slide, as mentioned previously, is employed for varying the measuring range in 2 steps (high and low illumination), however, it can also be used for direct reading.

speed 1

Slide No.

HIGH

  • Note:
  • HIGH slide can be used as a part of direct reading slide.
  • One set of slides consists of slide numbers 1 to 11 in a case.

HIGH slide is standard accessory and not included in the slide set, though there is a space to store it in the case of slide set.

Shutter

Page 21 of the Sekonic L-398A user manual — ※ Since it is not necessary to ro-
Pagina 21 · klik om te vergroten
Pagina 21

7. Optional Accessories Operation

2.Direct Reading Slide Application

When photographing, select slide from the above table according to film sensitivity and shutter speed. Insert slide and perform measure- ment in the same manner as for incident light. Read directly the ap- erture value r indicated by the meter needle !8.

※ Since it is not necessary to ro-

tate the dial when employing direct reading slides, setting becomes extremely fast and convenient.

Page 22 of the Sekonic L-398A user manual — 8. HANDLING CAUTIONS
Pagina 22 · klik om te vergroten
Pagina 22

8. HANDLING CAUTIONS

Since the Studio Deluxe Ⅲ is a high precision instrument, use ample care in regard to the following points.

  • Avoid dropping or subjecting it to strong shock.
  • Do not store in areas subject to magnetic fields or where insect

repellants are located (metal cabinets, clothing dressers, etc.). • Keep Lumisphere and Lumidisc clean and protect from dust and

scratches. • Wipe Lumisphere and Lumidisc with a dry soft cloth if it becomes

dirty. Never use organic cleaners (like Thinner or benzene).

Page 23 of the Sekonic L-398A user manual — 8. HANDLING CAUTIONS
Pagina 23 · klik om te vergroten
Pagina 23
Page 23 of the Sekonic L-398A user manual — 8. HANDLING CAUTIONS
Page 24 of the Sekonic L-398A user manual — JG1297521
Pagina 24 · klik om te vergroten
Pagina 24

7-24-14, OIZUMI-GAKUEN-CHO, NERIMA-KU,

TOKYO 178-8686 JAPAN

TEL:+81(0)3-3978-2335 FAX:+81(0)3-3978-5229

http://www.sekonic.co.jp/English

JG1297521

Vraag stellen over de Sekonic L-398A

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Sekonic L-398A

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Sekonic L-398A handleiding-pdf

24 pagina's·1.1 MB·Lichtmeter·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…