NL
Sharp logo
Officiële handleiding

Sharp KCF32EU

162 pagina's·20.7 MB·Luchtreiniger·PDF·ENITJA
Sharp KCF32EU
Inhoudsopgave 57 secties Home Appliances · Air Purifier · Air Purifier With Humidifying Function · KC-G60EU KC-G50EU KC-G40EU · … TonenVerbergen
Home Appliancesp.1Air Purifierp.1Air Purifier With Humidifying Functionp.1KC-G60EU KC-G50EU KC-G40EUp.1KC-F32EUp.1For Lifep.1Before operating your new air purifier, please read the followingp.2HEPA Filterp.2Deodorizing Filterp.2Pre-Filterp.2CONTENTS FEATURESp.3IMPORTANT SAFETY INSTRUCTIONS ...... E-2p.3PART NAMES ............................................... E-6p.3PREPARATION ............................................. E-8p.3OPERATION ................................................ E-10p.3USEFUL FUNCTION .................................. E-11p.3CARE AND MAINTENANCE .................... E-13p.3TROUBLESHOOTING ............................... E-18p.3SPECIFICATIONS ...................................... E-19p.3IMPORTANT SAFETY INSTRUCTIONSp.4CAUTIONS CONCERNING OPERATIONp.5INSTALLATION GUIDELINESp.6FILTER GUIDELINESp.6REFILLING THE HUMIDIFYING TRAYp.11CAUTIONp.11FULLp.11ORp.11USEFUL FUNCTIONp.14Off TIMERp.14Auto RESTARTp.14OFF ONp.14CARE AND MAINTENANCEp.15FILTER INDICATORp.15CARE INDEXp.15BACK PANELp.15SENSORp.15How to clean when overly dirtyp.15HUMIDIFYING FILTER / TRAYp.16How to remove the water scalep.17Wipe with a dry, soft cloth. CARE AND MAINTENACEp.18UNITp.18CLEANING FILTERSp.18DEODORIZING FILTER HEPA FILTERp.18FILTER REPLACEMENTp.19LIFE OF FILTERSp.19Replacement Filter Modelp.19AIR PURIFIER MODELp.19FZ-F30MFE FZ-F30DFE FZ-F30HFEp.19Do not throw away the Filter Frame (gray)p.19Disposing of filtersp.19TROUBLESHOOTINGp.20ERROR DISPLAYp.20DIGITAL INDICATION ERROR DETAILSp.20REMEDYp.20SPECIFICATIONSp.21CLEAN AIRp.21CLEAN AIR &HUMIDIFYp.21
Page 1 of the Sharp KCF32EU user manual — KC-G60EU KC-G50EU KC-G40EU
Pagina 1 · klik om te vergroten
Pagina 1

Home Appliances

Air Purifier

“Plasmacluster” and “Device of a cluster of grapes” are trade- marks of Sharp Corporation.

Manual de funcionamiento ES

Air Purifier With Humidifying Function

* The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm 3, which is measured around the center of a room with the “high-density Plasmacluster 7000” applicable floor area (at 1.2 m height above the floor) at the medium wind volume in humidifying & air purifying mode, or in air purifying mode, when a humidifier/air purifier or an air purifier using the high-density Plasmacluster ion evolving device is placed close to a wall. This product is equipped with a device corresponding to this capacity.

KC-G60EU KC-G50EU KC-G40EU

KC-F32EU

For Life

Show 7 more labels / short text on this page
Operation manual EN · Bedienungsanleitung DE · Manuel d’utilisation FR · Bedieningshandleiding NL · Instrukcja obsługi PL · Bruksanvisning SE · Brugsanvisning DK
Page 2 of the Sharp KCF32EU user manual — HEPA Filter
Pagina 2 · klik om te vergroten
Pagina 2

Before operating your new air purifier, please read the following

The air purifier draws in room air through the air intake, circulates it through a Pre-Filter, a Deodorizing Filter and a HEPA Filter inside the unit, and then discharges it through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the filter and also helps absorb odours. The Deodorizing Filter gradually absorbs odours as they pass through the filter.

Some odours absorbed by the filters will break down over time, causing additional odours. Depending on usage conditions, and especially if the product is used in environments significantly more severe than a normal household, these odours may become noticeable sooner than expected. If these odours persist, replace the filters. (Ref. E-16)

  • The air purifier is designed to remove air-suspended dust and the odours. The air purifier is not designed to remove harmful gases such as carbon monoxide contained in cigarette smoke. The air purifier may not completely remove an odour if the source of the odour is still present.

HEPA Filter

Deodorizing Filter

Pre-Filter

Page 3 of the Sharp KCF32EU user manual — Inhoudsopgave
Pagina 3 · Inhoud
Inhoud

Inhoud

Home Appliancesp.1Air Purifierp.1Air Purifier With Humidifying Functionp.1KC-G60EU KC-G50EU KC-G40EUp.1KC-F32EUp.1For Lifep.1Before operating your new air purifier, please read the followingp.2HEPA Filterp.2Deodorizing Filterp.2Pre-Filterp.2CONTENTS FEATURESp.3IMPORTANT SAFETY INSTRUCTIONS ...... E-2p.3PART NAMES ............................................... E-6p.3PREPARATION ............................................. E-8p.3OPERATION ................................................ E-10p.3USEFUL FUNCTION .................................. E-11p.3CARE AND MAINTENANCE .................... E-13p.3TROUBLESHOOTING ............................... E-18p.3SPECIFICATIONS ...................................... E-19p.3IMPORTANT SAFETY INSTRUCTIONSp.4CAUTIONS CONCERNING OPERATIONp.5INSTALLATION GUIDELINESp.6FILTER GUIDELINESp.6REFILLING THE HUMIDIFYING TRAYp.11CAUTIONp.11FULLp.11ORp.11USEFUL FUNCTIONp.14Off TIMERp.14Auto RESTARTp.14OFF ONp.14CARE AND MAINTENANCEp.15FILTER INDICATORp.15CARE INDEXp.15BACK PANELp.15SENSORp.15How to clean when overly dirtyp.15HUMIDIFYING FILTER / TRAYp.16How to remove the water scalep.17Wipe with a dry, soft cloth. CARE AND MAINTENACEp.18UNITp.18CLEANING FILTERSp.18DEODORIZING FILTER HEPA FILTERp.18FILTER REPLACEMENTp.19LIFE OF FILTERSp.19Replacement Filter Modelp.19AIR PURIFIER MODELp.19FZ-F30MFE FZ-F30DFE FZ-F30HFEp.19Do not throw away the Filter Frame (gray)p.19Disposing of filtersp.19TROUBLESHOOTINGp.20ERROR DISPLAYp.20DIGITAL INDICATION ERROR DETAILSp.20REMEDYp.20SPECIFICATIONSp.21CLEAN AIRp.21CLEAN AIR &HUMIDIFYp.21
Page 4 of the Sharp KCF32EU user manual — Always follow basic safety precautions when using electrical appliances, including the following:
Pagina 4 · klik om te vergroten
Pagina 4

IMPORTANT SAFETY INSTRUCTIONS

Always follow basic safety precautions when using electrical appliances, including the following:

  • Read all instructions before using the unit.
  • Use only a 220-240 volt outlet.
  • Do not use the unit if the power cord or plug is damaged or if the connection to the wall outlet is loosened.
  • Periodically remove dust from the power plug.
  • Do not insert fingers or foreign objects into the air intake or air outlet.
  • When removing the power plug, always hold the plug and never pull the cord. Failure to do so can cause a short circuit resulting in electrical shock or fire.
  • Do not remove the plug when your hands are wet.
  • Do not use this unit near gas appliances or fireplaces.
  • Always unplug the unit when refilling the Humidifying Tray, cleaning the unit, or when the unit is not in use. Failure to do so can cause a short circuit resulting in electrical shock or fire.
  • In order to avoid safety hazards, if the power cord is damaged, it must be replaced by either the manufacturer, a service agent, a Sharp authorized Service Centre or a similarly qualified service provider.
  • Only a Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service Centre for any problems, adjustments, or repairs.
  • Do not operate the unit in rooms where aerosol insecticides are present. Do not operate the unit in rooms where there is oily residue, incense, sparks from lit cigarettes, or chemical fumes in the air. Do not operate the unit in places where it may get wet, such as a bathroom.
  • Be cautious when cleaning the unit. Strong corrosive cleansers can damage the exterior.
  • When carrying / moving the unit, first remove the Humidifying Tray, and then hold the unit by the handles on both sides.
  • Carrying / moving the unit when there is water in the Humidifying Tray can cause the following:
  • Electrical shock.
  • Damage to the unit caused by internal spillage.
  • Water spillage.
  • Do not drink the water in the Humidifying Tray.
Page 5 of the Sharp KCF32EU user manual — CAUTIONS CONCERNING OPERATION
Pagina 5 · klik om te vergroten
Pagina 5
  • Replace the water in the Humidifying Tray daily with fresh tap water, and regularly clean it (Ref. E-14 and E-15). When the unit is not in use, dispose of the water in the Humidifying Tray. Leaving water in the Humidifying Tray can cause mold, bacteria, and bad odours. In rare cases, such bacteria can be a health hazard.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

If the air purifier interferes with radio or television reception, try one or more of the following measures:

  • Adjust or reposition the receiving antenna.
  • Increase the distance between the unit and the radio or TV.
  • Connect the equipment into an outlet on a circuit different from that of the radio or TV receiver.
  • Consult the dealer or an experienced radio/TV technician for help.

CAUTIONS CONCERNING OPERATION

  • Do not operate the unit without the filters and the Humidifying Tray properly installed.
  • Keep the unit away from water.
  • Do not wash and reuse the HEPA filter and Deodorizing filter. Doing so will not improve filter performance and can also cause electric shock or operating malfunctions.
  • Clean the exterior with a soft cloth only. Do not use volatile liquids or detergents. Doing so can damage or crack the exterior of the unit. In addition, doing so can cause sensor malfunctions.
  • The frequency of descaling maintenance will depend on the hardness of and the impurities in the water that you use; the harder the water the more often descaling will be necessary.
Page 6 of the Sharp KCF32EU user manual — FILTER GUIDELINES
Pagina 6 · klik om te vergroten
Pagina 6

IMPORTANT SAFETY INSTRUCTIONS

  • Before moving the unit, make sure it is not operating, and remove the Humidifying Tray while holding the side handle of the unit.
  • When removing / reattaching the Humidifying Tray, be careful not to get your fingers caught inside the unit.
  • When moving the unit, use the handles on both sides. Do not move the unit when it is in operation.
  • Do not block the air intake or air outlet.
  • Do not place the unit near or on hot objects, such as stoves or heaters, or where it may come into contact with steam.
  • Always operate the unit in an upright position.

INSTALLATION GUIDELINES

  • When using the unit, place it at least 2 metres away from equipment that emits electric waves, such as televisions or radios, to avoid electrical interference.
  • Avoid locations where the sensors are exposed to direct wind. Failure to do so can cause the unit to malfunction.
  • Avoid locations where furniture, fabrics, or other objects can come in contact with the unit and interfere with the intake and outtake of air.
  • Avoid locations where the unit is exposed to condensation or drastic changes in temperature. Appropriate room temperature is between 0 – 35 ºC.
  • Place the unit on a level and stable surface with sufficient air circulation. When placed on heavy carpet, the unit may vibrate slightly. Place the unit on a level surface to avoid water leakage from the Humidifying Tray.
  • Avoid locations that generate grease or oily smoke. Failure to do so can cause the unit exterior to crack and the sensors to malfunction.
  • The dust collecting ability of the unit is effective even when the unit is as close to 3 cm from the wall, the surrounding walls and floor may get dirty. Please place the unit at a distance from the wall. The wall directly behind the air outlet may become dirty over time. When using the unit for an extended period of time at the same location, periodically clean the walls adjacent to it.

FILTER GUIDELINES

  • Follow the instructions in this manual for proper filter care and maintenance.
Page 7 of the Sharp KCF32EU user manual — INSTALLATION GUIDELINES
Pagina 7 · klik om te vergroten
Pagina 7

A. Information on Disposal for Users (private households)

1. In the European Union

IF YOU WISH TO DISPOSE OF THIS EQUIPMENT, DO NOT USE THE ORDINARY WASTE BIN, AND DO NOT PUT THEM INTO A FIREPLACE! Used electrical and electronic equipment should always be collected and treated SEPA- RATELY in accordance with local law. Separate collection promotes an environment-friendly treatment, recycling of materials, and minimizing final disposal of waste. IMPROPER DISPOSAL can be harmful to human health and the environment due to certain substances! Take USED EQUIPMENT to a local, usually municipal, collection facility, where available. If in doubt about disposal, contact your local authorities or dealer and ask for the correct method of disposal. ONLY FOR USERS IN THE EUROPEAN UNION, AND SOME OTHER COUNTRIES; FOR INSTANCE NORWAY AND SWITZERLAND: Your participation in separate collection is requested by law. The symbol shown above appears on electrical and electronic equipment (or the packag- ing) to remind the users of this. Users from PRIVATE HOUSEHOLDS are requested to use existing return facilities for used equipment. Return is free of charge. If the equipment has been used for BUSINESS PURPOSES, please contact your SHARP dealer who will inform you about take-back. You might be charged for the costs arising from take-back. Small equipment (and small quantities) might be taken back by your local collection facility. For Spain: Please contact the established collection system or your local authority for take-back of your used products.

2. In other Countries outside the EU

If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.

For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch

B. Information on Disposal for Business Users.

1. In the European Union

If the product is used for business purposes and you want to discard it:

Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.

For Spain: Please contact the established collection system or your local authority for take-back of your used products.

2. In other Countries outside the EU

If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.

Page 8 of the Sharp KCF32EU user manual — INSTALLATION GUIDELINES
Pagina 8 · klik om te vergroten
Pagina 8
Sharp KCF32EU — INSTALLATION GUIDELINES diagram (page 8)
Afb. 1
1Operation Panel / Display (Ref.E-5)9Humidifying Tray 2Handle (2 Locations)10Float 3Main Unit11HEPA Filter 4Air Outlet12Deodorizing Filter 5Filter Frame13Sensor Filter / Sensor (internal) 6Humidifying Filter14Back Panel (Pre-Filter) 7Float (in Filter Frame)15Air lnlet 8Tray Handle16Power Cord / Plug
Page 9 of the Sharp KCF32EU user manual — INSTALLATION GUIDELINES
Pagina 9 · klik om te vergroten
Pagina 9
Sharp KCF32EU — INSTALLATION GUIDELINES diagram (page 9)
Afb. 2

Indicates the approximate humidity / temperature level in the room.

1START/STOP5OFF Timer Button 2CLEAN ION SHOWER Button / Indicator Light (green)6Display Select Button (Press 3 sec.) LIGHT ON/OFF Button(Press 3 sec.) FILTER RESET Button 3FAN SPEED Button7Filter Indicator Light (orange) (Press 3 sec.) Plasmacluster Ion ON/OFF Button8Plasmacluster Ion Indicator Light (blue) 4Fan Speed Indicator Lights (green)9OFF Timer Indicator Light (green)
Page 10 of the Sharp KCF32EU user manual — INSTALLATION GUIDELINES
Pagina 10 · klik om te vergroten
Pagina 10
Sharp KCF32EU — INSTALLATION GUIDELINES diagram (page 10)
Afb. 3

Always be sure to remove the power plug from the wall outlet.

Install the Filters in the correct order as shown.

Page 11 of the Sharp KCF32EU user manual — CAUTION
Pagina 11 · klik om te vergroten
Pagina 11

REFILLING THE HUMIDIFYING TRAY

Humidify air passed through by vaporizing water pumped up from Humidifying Tray. The unit can be used even without water in the Humidifying Tray.

Pull out the Humidifying Tray.

CAUTION

Clean the Humidifying Tray if it becomes dirty or there is a noticeable odour. (Ref. E-14,E-15)

Fill the Humidifying Tray with tap water by method A or B .

A

FULL

CAUTION

OR

  • The Filter Frame is floated up when water is filled.
  • When carrying the Humidifying Tray, hold it with both hands or grip the Tray Handle.
  • Gently fill it with water to avoid splash water.
  • Do not fill beyond the “FULL” indicator. The Humidifying Tray does not get into the unit if water is filled too much.

FULL

B

FULL

Install the Humidifying Tray.

  • Return the Tray Handle to its original position before installing.

CAUTION

Locate the Handle in front of Separator.

Do not locate the Handle on or behind Separator.

CAUTION

  • Do not expose the unit to water. Doing so can cause a short circuit or electrical shock.
  • Use only fresh tap water. Using other water sources risks the growth of molds, fungi, or bacteria.
  • Do not use hot water (40 ºC), chemical agents, aromatic substances. Doing so can deform the unit or cause it to malfunction.
  • When removing and installing the Humidifiying Tray, be careful not to spill any water.

Tray Handle · Handle · Separator

Page 12 of the Sharp KCF32EU user manual — REFILLING THE HUMIDIFYING TRAY
Pagina 12 · klik om te vergroten
Pagina 12
Sharp KCF32EU — REFILLING THE HUMIDIFYING TRAY diagram (page 12)
Afb. 4
  • START STOP
  • Select the desired fan speed with .
  • Unless the power cord has been unplugged, the operation starts in the previous mode it was operated in.

Releases high-density Plasmacluster ions and discharges strong air flow for 60 minutes.

  • When the operation finishes, the unit will return to the prior operation mode. It is able to change the other mode during this mode.
  • The fan speed is automatically switched between HIGH and LOW depending on the humidity and the amount of impurities in the room.
Page 13 of the Sharp KCF32EU user manual — REFILLING THE HUMIDIFYING TRAY
Pagina 13 · klik om te vergroten
Pagina 13
Sharp KCF32EU — REFILLING THE HUMIDIFYING TRAY diagram (page 13)
Afb. 5

You can set the front surface Indicators to OFF when the Indicator is too bright.

When Plasmacluster Ion is ON, the Plasmacluster Ion Indicator Light is on. (blue)

You can select either humidity or temperature at the time to be displayed.

Current temperature and current humidity indicate the estimated values. The values may be different from values indicated by other temperature gauge hygrometer.

  • There is no function for adjusting the temperature.
  • Humidity setting cannot be adjusted.
  • Cannot dehumidify .
Page 14 of the Sharp KCF32EU user manual — OFF ON
Pagina 14 · klik om te vergroten
Pagina 14

USEFUL FUNCTION

Off TIMER

Select the length of time you want. The unit automatically stops once the selected time is reached.

1 hour 2 hours 4 hours 8 hours CANCELLATION

  • Pressing displays the remaining time.
  • To reset the operating time, press while the remaining time is being displayed.

Auto RESTART

If the unit is unplugged or if there is a power failure, the unit will resume operation with the previous settings after power is restored. The default setting is ON.

OFF ON

(with the unit OFF) (with the unit OFF)

Press both buttons at the same time for 3 seconds or more.

Press both buttons at the same time for 3 seconds or more.

If the , and indicators light up for 10 seconds, the setting is completed.

Lighting

Page 15 of the Sharp KCF32EU user manual — SENSOR
Pagina 15 · klik om te vergroten
Pagina 15

CARE AND MAINTENANCE

FILTER INDICATOR

The filter Indicator Light will turn on after approximately 720 hours. (30 days × 24 hours =720 hours)

After performing maintenance, reset the Filter Indicator.

RESET (Press 3 sec.) RESET (Press 3 sec.) This is a reminder to perform the maintenance described below. (Ref.E-13,E-14,E-15,E-16)

Press more than 3 seconds.

CARE INDEX

In case of using at the location where air pollution and odour are significant, maintain frequently even if Filter Indicator Light is not ON.

HEPA Filter (Ref.E-16)

(Ref.E-16)

Unit (Ref.E-16)

(Ref.E-14,E-15)

BACK PANEL

Gently remove dust with an appropriate cleaning tool, such as a vacuum cleaner with the proper attachment.

SENSOR

How to clean when overly dirty

BACK PANEL

1. Add a small amount of kitchen detergent to water and soak for about 10 minutes.

CAUTION

CAUTION

  • DO NOT apply excessive pressure when scrubbing the back panel.
2. Rinse off the kitchen detergent with clean water.
3. Completely dry the filter in a well-ventilated area.

SENSOR

1. Remove the Back Panel and removing the Sensor Filter. 2. Gently remove dust from the Sensor with an appropriate cleaning tool, such as a vacuum cleaner with the proper attachment. 3. If the Sensor Filter is overly dirty, wash it with water and dry it thoroughly.
Show 9 more labels / short text on this page
Deodorizing Filter · Sensor Filter · Humidifying Filter · Filter Frame · Back Panel · Humidifying Tray · Sensor (internal) · Back Panel · Sensor Filter
Page 16 of the Sharp KCF32EU user manual — CAUTION
Pagina 16 · klik om te vergroten
Pagina 16

CARE AND MAINTENANCE

HUMIDIFYING FILTER / TRAY

HUMIDIFYING FILTER / TRAY

Odour occurrence may be suppressed when washing Humidifying Filter and Humidifying Tray with water carefully even if the Filter Indicator Light is not ON.

Remove the Humidifying Filter from the Tray.

Remove the Filter Frame. Remove the Humidifying Filter. Turn the handle down on the reverse side.

CAUTION

  • Drops of water may drip from the Humidifying Filter and the Filter Frame.

Rinse the Humidifying Tray, the Filter Frame and the Humidifying Filter.

Humidifying Filter Float (Styrofoam) Humidifying Tray

CAUTION

  • Do not remove the Floats.
  • If the Float comes off from the Humidifying Tray, install it in the order shown below.
1. Insert the float under this tab.
3. Insert the tab on the other side of the float into the hole.
2. Insert the tab of the float into the hole.
Show 8 more labels / short text on this page
Turn down Remove · Pull up · Open · Filter Frame · Float · Cross-Section view · Tab · Float
Page 17 of the Sharp KCF32EU user manual — CAUTION
Pagina 17 · klik om te vergroten
Pagina 17

Always be sure to remove the power plug from the wall outlet.

How to remove the water scale

1. Soak in water with a descaling solution for about more 30 minutes.
  • Citric acid (available at some drugstores)
  • 100% bottled lemon juice with no pulp. <with citric acid>

CAUTION

  • When using lemon juice as your descaling solution, allow for more soak time.

2 cups of water

2. Rinse off the descaling solution with plenty of water.

3 cups of water

How to clean the Humidifying Tray and the Filter Frame when overly dirty

  • 1.
  • Remove the Filter Frame from the Humidifying Tray and fill it with water until the “FULL” indicator.
  • Put the Filter Frame in water. 2. Add a small amount of kitchen detergent to the water. 3. Soak for 30 minutes. 4. Rinse off the kitchen detergent with clean water.
  • Clean any hard-to-reach parts which with a cotton swab or toothbrush.

After maintenance, correctly reattach the parts.

Align the directions.

Hook latches of cover (3 positions).

Install the Humidifying Filter by fitting the grooves at left and right side to the guides on the Humidifying Tray.

Also in the same left side.

Return the Tray Handle to its original position.

Lift the Tray Handle.

Return it to its original position.

Show 13 more labels / short text on this page
Recommended descaling solutions · stir well! · / · 3 tea- spoons · <with lemon juice> · stir well! · / · 4 cup · Right side · Install · Close · Groove · Guide
Page 18 of the Sharp KCF32EU user manual — CAUTION
Pagina 18 · klik om te vergroten
Pagina 18

Wipe with a dry, soft cloth. CARE AND MAINTENACE

UNIT

Sharp KCF32EU — UNIT diagram (page 18)
Afb. 6

CAUTION

  • Do not use volatile fluids. Benzene paint thinner or polishing powder can damage the surface.
  • Do not use detergents. Detergent ingredients can damage the unit.

CLEANING FILTERS

Gently remove dust with an appropriate cleaning tool, such as a vacuum cleaner with the proper attachment. In case of using at the location where air pollution and odour are significant, maintain frequently even if Filter Indicator Light is not ON.

DEODORIZING FILTER HEPA FILTER

  • Both surfaces can be maintained.
  • Maintain only the tagged surface. Do not clean up the opposite surface.

CAUTION

  • Do not wash the filters. Do not expose to sunlight.

Some odours absorbed by the filters will break down over time, causing additional odours. Depending on usage conditions, and especially if the product is used in environments significantly more severe than a normal household, these odours may become noticeable sooner than expected. Replace the filter in those cases or if dust is unable to be removed after maintenance.

Tag

Page 19 of the Sharp KCF32EU user manual — HEPA Filter
Pagina 19 · klik om te vergroten
Pagina 19

Always be sure to remove the power plug from the wall outlet.

FILTER REPLACEMENT

FILTER REPLACEMENT

LIFE OF FILTERS

Filter life varies depending on the room environment, usage conditions, and location of the unit. Lifespan of HEPA filter and Deodorizing filter and replacement suggestions are based on purifying a room in which 5 cigarettes are smoked per day and the unit's dust collection and deodorizing performance has declined to half the level of a new filter.

We recommend replacing the filter more frequently if the unit is used in conditions significantly more severe (HAZE etc.,) than a normal household.

  • HEPA Filter About 2 years after opening
  • Deodorizing Filter About 2 years after opening
  • Humidifying Filter About 5 years after opening

Replacement Filter Model

Consult your dealer when purchasing a replacement filter. Humidifying Filter

REPLACEMENT FILTER MODEL

AIR PURIFIER MODEL

HEPA Filter1 unit Deodorizing Filter : 1 unit
Humidifying Filter1 unit

KC-F32EU

FZ-F30MFE FZ-F30DFE FZ-F30HFE

Use the date label to remind you when to replace the filter. There is the date label on the left side of the unit.

Do not throw away the Filter Frame (gray)

Disposing of filters

Dispose of used filters according to local laws and regulations.

  • HEPA Filter material:
  • Filter : Polypropylene
  • Frame : Polyester Deodorizing Filter material:
  • Filter : Activated charcoal, Polyrthylene terephthalate,
  • Polypropylene
  • Frame : Paper Humidifying Filter material :
  • Filter : Rayon, Polyester

HEPA Filter

Deodorizing Filter

Page 20 of the Sharp KCF32EU user manual — DIGITAL INDICATION ERROR DETAILS
Pagina 20 · klik om te vergroten
Pagina 20

TROUBLESHOOTING

Before calling for service, review the troubleshooting chart below to make sure that the problem is not a unit malfunction.

SYMPTOM REMEDY (the following are not due to a malfunction)

Odour and smoke persists. • Check the filters. If they appear to be extremely dirty, clean or replace them. (Ref. E-13,E-14,E-15,E-16,E-17)

The Dust Sign light is green even when the air is not clean.

  • The air may have been dirty when the unit was plugged in. Unplug the unit, wait one minute, and then plug the unit in again.

The Dust Sign light is orange or red even when the air is clean.

  • Dirty or clogged dust sensor openings interfere with sensor operation. Gently clean the back panel. (Ref. E-13).

The unit makes a clicking or ticking sound.

  • The unit may make clicking or ticking sounds when it is generating ions.

Air discharged from the unit has an odour.

  • Check to see if the filters are extremely dirty.
  • Clean or replace the filters.
  • Plasmacluster Air Purifiers emit small traces of ozone that can produce an odour.

The unit does not operate when cigarette smoke is in the air.

  • Check to see if the unit is installed in a location that makes it difficult for the sensors to detect cigarette smoke.
  • Check to see if the dust sensor openings are blocked or clogged. If they are blocked or clogged, clean the back panel. (Ref. E-13)

The Filter Indicator Light is on.

  • Whenever replacing the filters, connect the power cord to an outlet and then press the Filter Reset Button.

The Dust Sign lights are turned off.

  • Check to see if the Lights OFF Mode is selected. If it is selected, press the Light ON/OFF Button to turn the indicator lights on. (Ref. E-11)
  • Check to see if the SLEEP mode is selected. (Ref. E-10)

The Humidify Light does not light off when the Humidifying Tray is empty.

  • Clean the Humidifying Tray. Make sure that the unit is on a level surface.
  • Check to see if the Humidifying Tray is correctly installed. Check the Humidifying Filter.
  • If the Humidifying Filter is extremely dirty, clean or replace it. (Ref. E-14, E-15, E-17).
  • Humidification amount gets lower when humidity reaches to the proper amount (55 ~ 65%) by the actuation of humidity sensor in the case of fan speed automatic.

The water level in the Humidifying Tray does not decrease or decreases slowly.

The Dust Sign lights change colour frequently.

  • The Dust Sign lights automatically change colour when the dust sensor detect impurities.

There is a discrepancy between the unit’s Humidity Monitor and another hygrometer in the room.

  • There is a difference in the humidity level within the same room.
  • The sensor have different measurement parameters.
  • If the monitor indicates TEMPERATURE, press the Display Select Button. (Ref. E-11)

ERROR DISPLAY

If the error continues to occur, contact a Sharp Service Centre.

DIGITAL INDICATION ERROR DETAILS

REMEDY

Fan motor error.

Unplug the unit, wait one minute, then plug the unit in again.

Temperature-humidity sensor error.

Page 21 of the Sharp KCF32EU user manual — CLEAN AIR &HUMIDIFY
Pagina 21 · klik om te vergroten
Pagina 21

SPECIFICATIONS

Power supply 220-240V 50-60Hz

Fan Speed Adjustment MAX MED SLEEP

3/hour) 180 125 52 Rated Power (W) 27 12 4.1

CLEAN AIR

Noise Level (dBA) 48 38 21

3/hour) 180 125 52

CLEAN AIR &HUMIDIFY

Rated Power (W) 27 12 4.1

Noise Level (dBA) 48 38 21

Humidification (mL/hour)*1 350 280 140

Recommended Room Size (m

High density Plasmacluster ion recommended room size (m

Humidifying Tray Capacity (L) 1.8

Sensors Dust / Temperature & Humidity

Dust collection HEPA *4

Cord Length (m) 2.0

Dimensions (mm) 380 (W) × 197 (D) × 570 (H)

Weight (kg) 7.2

  • *1
  • The amount of humidification changes in accordance with indoor and outdoor temperature and humidity. The amount of humidification increases as temperatures rises or humidity decreases. The amount of humidification decreases as temperatures decrease or humidity rises.
  • Measurement Conditions : 20 ºC, 30 % humidity (JEM1426)
  • *2
  • The recommended room size is appropriate for operating the unit of maximum fan speed.
  • The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes.

*3 • Room size in which approximately 7000 ions per cubic centimeter can be measured in the centre of the room when the unit is placed next to a wall, is running at maximum settings, and is at a height of approximately 1.2 meters from the floor.

*4 • The filter removes more than 99.97% of particles at least 0.3-microns in size. (JEM1467)

Standby Power When the unit’s power plug is inserted in a wall outlet it consumes about 0.9 watts of standby power in order to operate electrical circuits. To conserve energy, unplug the power cord when the unit is not in use.

Show 6 more labels / short text on this page
Fan Speed (m · Fan Speed (m · 2)*2 ~21 · 2)*3 ~17 · Filter type · Deodorization Deodorizing
Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
Odour and smoke persists.• Check the filters. If they appear to be extremely dirty, clean or replace them. (Ref. E-13,E-14,E-15,E-16,E-17) p.20
The Dust Sign light is green even when the air is not clean.• The air may have been dirty when the unit was plugged in. Unplug the unit, wait one minute, and then plug the unit in again. p.20
The Dust Sign light is orange or red even when the air is clean.• Dirty or clogged dust sensor openings interfere with sensor operation. Gently clean the back panel. (Ref. E-13). p.20
The unit makes a clicking or ticking sound.• The unit may make clicking or ticking sounds when it is generating ions. p.20
Air discharged from the unit has an odour.• Check to see if the filters are extremely dirty. • Clean or replace the filters. • Plasmacluster Air Purifiers emit small traces of ozone that can produce an odour. p.20
The unit does not operate when cigarette smoke is in the air.• Check to see if the unit is installed in a location that makes it difficult for the sensors to detect cigarette smoke. • Check to see if the dust sensor openings are blocked or clogged. If they are blocked or clogged, clean the back panel. (Ref. E-13) p.20
The Filter Indicator Light is on.• Whenever replacing the filters, connect the power cord to an outlet and then press the Filter Reset Button. p.20
The Dust Sign lights are turned off.• Check to see if the Lights OFF Mode is selected. If it is selected, press the Light ON/OFF Button to turn the indicator lights on. (Ref. E-11) • Check to see if the SLEEP mode is selected. (Ref. E-10) p.20
The Humidify Light does not light off when the Humidifying Tray is empty.• Clean the Humidifying Tray. Make sure that the unit is on a level surface. p.20
The water level in the Humidifying Tray does not decrease or decreases slowly.• Check to see if the Humidifying Tray is correctly installed. Check the Humidifying Filter. • If the Humidifying Filter is extremely dirty, clean or replace it. (Ref. E-14, E-15, E-17). • Humidification amount gets lower when humidity reaches to the proper amount (55 ~ 65%) by the actuation of humidity sensor in the case of fan speed automatic. p.20
The Dust Sign lights change colour frequently.• The Dust Sign lights automatically change colour when the dust sensor detect impurities. p.20
There is a discrepancy between the unit’s Humidity Monitor and another hygrometer in the room.• There is a difference in the humidity level within the same room. • The sensor have different measurement parameters. • If the monitor indicates TEMPERATURE, press the Display Select Button. (Ref. E-11) p.20

Vraag stellen over de Sharp KCF32EU

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Sharp KCF32EU

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Sharp KCF32EU handleiding-pdf

162 pagina's·20.7 MB·Luchtreiniger·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%