Air Purifier
“Plasmacluster” and “Device of a cluster of grapes” are trade- marks of Sharp Corporation.
Manual de funcionamiento ES
* The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm 3, which is measured around the center of a room with the “high-density Plasmacluster 7000” applicable floor area (at 1.2 m height above the floor) at the medium wind volume in humidifying & air purifying mode, or in air purifying mode, when a humidifier/air purifier or an air purifier using the high-density Plasmacluster ion evolving device is placed close to a wall. This product is equipped with a device corresponding to this capacity.
KC-F32EU
For Life

The air purifier draws in room air through the air intake, circulates it through a Pre-Filter, a Deodorizing Filter and a HEPA Filter inside the unit, and then discharges it through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the filter and also helps absorb odours. The Deodorizing Filter gradually absorbs odours as they pass through the filter.
Some odours absorbed by the filters will break down over time, causing additional odours. Depending on usage conditions, and especially if the product is used in environments significantly more severe than a normal household, these odours may become noticeable sooner than expected. If these odours persist, replace the filters. (Ref. E-16)
Deodorizing Filter
Pre-Filter



If the air purifier interferes with radio or television reception, try one or more of the following measures:


A. Information on Disposal for Users (private households)
IF YOU WISH TO DISPOSE OF THIS EQUIPMENT, DO NOT USE THE ORDINARY WASTE BIN, AND DO NOT PUT THEM INTO A FIREPLACE! Used electrical and electronic equipment should always be collected and treated SEPA- RATELY in accordance with local law. Separate collection promotes an environment-friendly treatment, recycling of materials, and minimizing final disposal of waste. IMPROPER DISPOSAL can be harmful to human health and the environment due to certain substances! Take USED EQUIPMENT to a local, usually municipal, collection facility, where available. If in doubt about disposal, contact your local authorities or dealer and ask for the correct method of disposal. ONLY FOR USERS IN THE EUROPEAN UNION, AND SOME OTHER COUNTRIES; FOR INSTANCE NORWAY AND SWITZERLAND: Your participation in separate collection is requested by law. The symbol shown above appears on electrical and electronic equipment (or the packag- ing) to remind the users of this. Users from PRIVATE HOUSEHOLDS are requested to use existing return facilities for used equipment. Return is free of charge. If the equipment has been used for BUSINESS PURPOSES, please contact your SHARP dealer who will inform you about take-back. You might be charged for the costs arising from take-back. Small equipment (and small quantities) might be taken back by your local collection facility. For Spain: Please contact the established collection system or your local authority for take-back of your used products.
If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.
For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch
B. Information on Disposal for Business Users.
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.
For Spain: Please contact the established collection system or your local authority for take-back of your used products.
If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.




Indicates the approximate humidity / temperature level in the room.


Always be sure to remove the power plug from the wall outlet.
Install the Filters in the correct order as shown.

Humidify air passed through by vaporizing water pumped up from Humidifying Tray. The unit can be used even without water in the Humidifying Tray.
Pull out the Humidifying Tray.
Clean the Humidifying Tray if it becomes dirty or there is a noticeable odour. (Ref. E-14,E-15)
Fill the Humidifying Tray with tap water by method A or B .
FULL
CAUTION
OR
B
FULL
Install the Humidifying Tray.
Locate the Handle in front of Separator.
Do not locate the Handle on or behind Separator.
Tray Handle · Handle · Separator


Releases high-density Plasmacluster ions and discharges strong air flow for 60 minutes.


You can set the front surface Indicators to OFF when the Indicator is too bright.
When Plasmacluster Ion is ON, the Plasmacluster Ion Indicator Light is on. (blue)
You can select either humidity or temperature at the time to be displayed.
Current temperature and current humidity indicate the estimated values. The values may be different from values indicated by other temperature gauge hygrometer.

Select the length of time you want. The unit automatically stops once the selected time is reached.
1 hour 2 hours 4 hours 8 hours CANCELLATION
If the unit is unplugged or if there is a power failure, the unit will resume operation with the previous settings after power is restored. The default setting is ON.
(with the unit OFF) (with the unit OFF)
Press both buttons at the same time for 3 seconds or more.
Press both buttons at the same time for 3 seconds or more.
If the , and indicators light up for 10 seconds, the setting is completed.
Lighting

The filter Indicator Light will turn on after approximately 720 hours. (30 days × 24 hours =720 hours)
After performing maintenance, reset the Filter Indicator.
RESET (Press 3 sec.) RESET (Press 3 sec.) This is a reminder to perform the maintenance described below. (Ref.E-13,E-14,E-15,E-16)
Press more than 3 seconds.
In case of using at the location where air pollution and odour are significant, maintain frequently even if Filter Indicator Light is not ON.
HEPA Filter (Ref.E-16)
(Ref.E-16)
Unit (Ref.E-16)
(Ref.E-14,E-15)
Gently remove dust with an appropriate cleaning tool, such as a vacuum cleaner with the proper attachment.
BACK PANEL
CAUTION

HUMIDIFYING FILTER / TRAY
Odour occurrence may be suppressed when washing Humidifying Filter and Humidifying Tray with water carefully even if the Filter Indicator Light is not ON.
Remove the Humidifying Filter from the Tray.
Remove the Filter Frame. Remove the Humidifying Filter. Turn the handle down on the reverse side.
Rinse the Humidifying Tray, the Filter Frame and the Humidifying Filter.
Humidifying Filter Float (Styrofoam) Humidifying Tray

Always be sure to remove the power plug from the wall outlet.
2 cups of water
3 cups of water
How to clean the Humidifying Tray and the Filter Frame when overly dirty
After maintenance, correctly reattach the parts.
Align the directions.
Hook latches of cover (3 positions).
Install the Humidifying Filter by fitting the grooves at left and right side to the guides on the Humidifying Tray.
Also in the same left side.
Return the Tray Handle to its original position.
Lift the Tray Handle.
Return it to its original position.


Gently remove dust with an appropriate cleaning tool, such as a vacuum cleaner with the proper attachment. In case of using at the location where air pollution and odour are significant, maintain frequently even if Filter Indicator Light is not ON.
Some odours absorbed by the filters will break down over time, causing additional odours. Depending on usage conditions, and especially if the product is used in environments significantly more severe than a normal household, these odours may become noticeable sooner than expected. Replace the filter in those cases or if dust is unable to be removed after maintenance.
Tag

Always be sure to remove the power plug from the wall outlet.
FILTER REPLACEMENT
LIFE OF FILTERS
Filter life varies depending on the room environment, usage conditions, and location of the unit. Lifespan of HEPA filter and Deodorizing filter and replacement suggestions are based on purifying a room in which 5 cigarettes are smoked per day and the unit's dust collection and deodorizing performance has declined to half the level of a new filter.
We recommend replacing the filter more frequently if the unit is used in conditions significantly more severe (HAZE etc.,) than a normal household.
Consult your dealer when purchasing a replacement filter. Humidifying Filter
AIR PURIFIER MODEL
FZ-F30MFE FZ-F30DFE FZ-F30HFE
Use the date label to remind you when to replace the filter. There is the date label on the left side of the unit.
Disposing of filters
Dispose of used filters according to local laws and regulations.
Deodorizing Filter

Before calling for service, review the troubleshooting chart below to make sure that the problem is not a unit malfunction.
SYMPTOM REMEDY (the following are not due to a malfunction)
Odour and smoke persists. • Check the filters. If they appear to be extremely dirty, clean or replace them. (Ref. E-13,E-14,E-15,E-16,E-17)
The Dust Sign light is green even when the air is not clean.
The Dust Sign light is orange or red even when the air is clean.
The unit makes a clicking or ticking sound.
Air discharged from the unit has an odour.
The unit does not operate when cigarette smoke is in the air.
The Filter Indicator Light is on.
The Dust Sign lights are turned off.
The Humidify Light does not light off when the Humidifying Tray is empty.
The water level in the Humidifying Tray does not decrease or decreases slowly.
The Dust Sign lights change colour frequently.
There is a discrepancy between the unit’s Humidity Monitor and another hygrometer in the room.
If the error continues to occur, contact a Sharp Service Centre.
REMEDY
Fan motor error.
Unplug the unit, wait one minute, then plug the unit in again.
Temperature-humidity sensor error.

Power supply 220-240V 50-60Hz
Fan Speed Adjustment MAX MED SLEEP
3/hour) 180 125 52 Rated Power (W) 27 12 4.1
Noise Level (dBA) 48 38 21
3/hour) 180 125 52
Rated Power (W) 27 12 4.1
Noise Level (dBA) 48 38 21
Humidification (mL/hour)*1 350 280 140
Recommended Room Size (m
High density Plasmacluster ion recommended room size (m
Humidifying Tray Capacity (L) 1.8
Sensors Dust / Temperature & Humidity
Dust collection HEPA *4
Cord Length (m) 2.0
Dimensions (mm) 380 (W) × 197 (D) × 570 (H)
Weight (kg) 7.2
*3 • Room size in which approximately 7000 ions per cubic centimeter can be measured in the centre of the room when the unit is placed next to a wall, is running at maximum settings, and is at a height of approximately 1.2 meters from the floor.
*4 • The filter removes more than 99.97% of particles at least 0.3-microns in size. (JEM1467)
Standby Power When the unit’s power plug is inserted in a wall outlet it consumes about 0.9 watts of standby power in order to operate electrical circuits. To conserve energy, unplug the power cord when the unit is not in use.
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| Odour and smoke persists. | • Check the filters. If they appear to be extremely dirty, clean or replace them. (Ref. E-13,E-14,E-15,E-16,E-17) | p.20 | |
| The Dust Sign light is green even when the air is not clean. | • The air may have been dirty when the unit was plugged in. Unplug the unit, wait one minute, and then plug the unit in again. | p.20 | |
| The Dust Sign light is orange or red even when the air is clean. | • Dirty or clogged dust sensor openings interfere with sensor operation. Gently clean the back panel. (Ref. E-13). | p.20 | |
| The unit makes a clicking or ticking sound. | • The unit may make clicking or ticking sounds when it is generating ions. | p.20 | |
| Air discharged from the unit has an odour. | • Check to see if the filters are extremely dirty. • Clean or replace the filters. • Plasmacluster Air Purifiers emit small traces of ozone that can produce an odour. | p.20 | |
| The unit does not operate when cigarette smoke is in the air. | • Check to see if the unit is installed in a location that makes it difficult for the sensors to detect cigarette smoke. • Check to see if the dust sensor openings are blocked or clogged. If they are blocked or clogged, clean the back panel. (Ref. E-13) | p.20 | |
| The Filter Indicator Light is on. | • Whenever replacing the filters, connect the power cord to an outlet and then press the Filter Reset Button. | p.20 | |
| The Dust Sign lights are turned off. | • Check to see if the Lights OFF Mode is selected. If it is selected, press the Light ON/OFF Button to turn the indicator lights on. (Ref. E-11) • Check to see if the SLEEP mode is selected. (Ref. E-10) | p.20 | |
| The Humidify Light does not light off when the Humidifying Tray is empty. | • Clean the Humidifying Tray. Make sure that the unit is on a level surface. | p.20 | |
| The water level in the Humidifying Tray does not decrease or decreases slowly. | • Check to see if the Humidifying Tray is correctly installed. Check the Humidifying Filter. • If the Humidifying Filter is extremely dirty, clean or replace it. (Ref. E-14, E-15, E-17). • Humidification amount gets lower when humidity reaches to the proper amount (55 ~ 65%) by the actuation of humidity sensor in the case of fan speed automatic. | p.20 | |
| The Dust Sign lights change colour frequently. | • The Dust Sign lights automatically change colour when the dust sensor detect impurities. | p.20 | |
| There is a discrepancy between the unit’s Humidity Monitor and another hygrometer in the room. | • There is a difference in the humidity level within the same room. • The sensor have different measurement parameters. • If the monitor indicates TEMPERATURE, press the Display Select Button. (Ref. E-11) | p.20 |
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.