Page 1 of the Siemens DH21400M user manual — detergents!
Pagina 1 · klik om te vergroten
Pagina 1

Safety information

  • Only connect the continuous-flow heater

to a cold water line.

This appliance is intended for domestic use and the household environment only.

  • The continuous-flow heater is suitable for

connection to DVGW-tested plastic pipes.

  • Install and operate the appliance as de-

scribed in the text and illustrations. We do not accept liability for damage resulting from failure to heed these instructions.

  • Disconnect the electrical connection

cable from the supply and shut off the water supply before connecting the appliance!

  • This appliance is intended for use up to an
  • Connect the water supply and then

altitude of 2000 m above sea level.

connect the electrical supply.

  • The appliance may only be installed and

stored in a frost-free room (due to residual water).

  • Only make the openings which are re-

quired for installation on the rear of the appliance. If the appliance is reinstalled, the unused openings must be provided with watertight sealing.

Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs. Immediately shut off the cold water supply to the appliance should it leak.

  • Do not touch electrically live parts after

installation.

  • The appliance should be disconnected
  • The continuous-flow heater may only be

connected and put into operation by a qualified professional.

from the electrical mains supply when working on the water supply. After service work is complete, proceed as during the first-time appliance start-up.

  • In order to avoid potential sources of
  • No changes may be made to the appliance.
  • The appliance may only be used for heat-
  • Never open the appliance without discon-

ing drinking water for household use.

necting the power supply beforehand.

  • This appliance can be used by children

aged 8 years and older as well as by per- sons with diminished bodily, sensory or mental perception, or those who lack knowledge or experience, if they are moni- tored or have received instruction concern- ing use and comprehend the possible dan- gers that can result. Children may not play with the appliance. Cleaning and mainte- nance by the user may not be performed by unsupervised children.

  • The statutory regulations of the respective

country, as well as those of the local electric- ity and water suppliers, must be adhered to.

  • The continuous-flow heater is a Class I

appliance and must be connected to the protective earth.

  • The appliance must be permanently

connected to installed pipes. The conduc- tor cross-section must comply with the installed appliance power.

  • Keep children away from the appliance.
  • Caution : Earthed water pipes may give the
  • Please monitor children to ensure that they

appearance of a connected protective earth.

do not play with the appliance.

  • To guarantee compliance to relevant safety
  • The mixer and the warm water pipe may

regulations, an all-pole separator must be fitted during installation. The contact opening must be at least 3 mm.

be hot. Please inform and instruct children appropriately.

  • Do not use aggressive or abrasive cleaning
  • The continuous-flow heater is only suitable

detergents!

for closed (pressurised) operation.

  • Do not use a steam cleaner.
  • The tap and outlet fittings must be ap-

proved for operation with closed (pressur- ised) continuous-flow heater systems.

  • The appliance is only to be descaled by a

suitably qualified specialist.

Page 2 of the Siemens DH21400M user manual — A B Additional information
Pagina 2 · klik om te vergroten
Pagina 2

Congratulations on purchasing this Siemens appliance. You have acquired a top-quality product, which will give you a lot of enjoyment.

IV. Water connection

  • The continuous-flow heater must be vented. Open the

warm water tap fully and flush out the appliance thorough- ly for 1 minute.

Please read this installation and operating instruction manual carefully, then act accordingly! Store for future reference.

  • The flow-rate limiter must be installed in the old water

regulating valve.

V. Electrical connection

Installation instructions

  • The electrical supply terminal can be fitted at the top or

bottom. The sheath of the connection cable must extend for at least 40 mm into the appliance.

Install the continuous-flow heater as described in the illustrated section. Observe the instructions in the text.

The illustrations can be found in the centre of the instruction manual.

  • The installation of non plug-in ready appliances must be

undertaken by the respective utility operator or by a quali- fied specialist company, who can also assist you when you are requesting the approval of the utility company for installation of the appliance.

Installation

I. Unpacking/removing the cover

  • Unpack the appliance and check for transport damage.

VI. Startup

  • Dispose of the packaging and, where applicable, the old

The device is compliant to IEC 61000-3-12.

appliance, in an environmentally conscious manner.

  • At low water pipe pressure, check whether the II setting

switches on even when water is drawn from several cold- water taps simultaneously. If not, remove the flow limiter (refer to additional information A).

II. Preparation for installation

  • Instruct the user with regard to the operation of the con-
  • Shut off water supply. The electrical connection (connec-

tinuous-flow heater.

tion cable) must be disconnected from the power supply. Unscrew the fuse or switch off the circuit breaker.

A B Additional information

III. Wall mounting

  • If the water pressure of the interior system is low, do not

operate the continuous-flow heater at full power, but re- move the flow limiter (Fig. A, 3.).

  • The continuous-flow heater must be fitted securely to

the wall. If required, secure the appliance using the lower adjusting screws.

  • Priority circuit for the combined operation of electric stor-
  • The distance from the wall is variable. This allows you to

age heaters (Fig. B).

compensate for any unevenness in the wall surface.

  • The sleeve must fit tightly round the connection cable. If

the sleeve is damaged during installation, the holes must be sealed water-tight.

Installation note

Page 3 of the Siemens DH21400M user manual — C Dimensions
Pagina 3 · klik om te vergroten
Pagina 3

Specifications

DH12400MDH18400MDH21400MDH24400MDH40018MDH40021MDH40024M Rated power [kW]13.2182124182124 Rated voltage400 V 3~400 V 3~400 V 3~400 V 3~400 V 3~400 V 3~400 V 3~ Economy setting e [kW] 1st stage––––678 2nd stage8121416121416 Intensive setting II [kW] 1st stage 2nd stage– 12– 18– 21– 249 1810.5 2112 24 Switch-on point [I/min] 1st stage––––4.04.55.0 2nd stage3.65.05.86.65.05.86.6 Mixed water [I/min] at rated power approx. 38 °C approx. 50 °C (supply temperature 12 °C)6.6 4.59.9 6.811.6 7.913.2 9.19.9 6.811.6 7.913.2 9.1 Minimum flow pressure of appliance* [MPa (bar)] with flow limiter0.03 (0.3)0.07 (0.7)0.08 (0.8)0.09 (0.9)0.07 (0.7)0.08 (0.8)0.09 (0.9) without flow limiter0.02 (0.2)0.04 (0.4)0.05 (0.5)0.06 (0.6)0.04 (0.4)0.05 (0.5)0.06 (0.6) Application area in water specific electric resistance at 15 °C [Ωcm]≥ 800≥ 1 300≥ 1 300≥ 1 300≥ 1 300≥ 1 300≥ 1 300 Rated pressure [MPa (bar)]1 (10)1 (10) Maximum permissible supply temperature [°C]20202020202020 Energy efficiency classAAAAAAA Load profileSSSSSSS Annual energy consumption [kWh]480481483483481483483 Daily energy consumption [kWh]2.2132.2152.2282.2322.2152.2282.232 Sound power level [dB]15151515151515 Hot water heating energy efficiency [%]38.438.438.238.138.438.238.1

* Plus any pressure loss at the tap mixer

C Dimensions

Special accessories

  • BZ45U21 Pipe set: for use of the continuous-flow heater

as an under sink appliance

  • Priority switch (load shedding relay) BZ45L21 :

for operation with the priority circuit

  • Mounting set BZ45K23 : for surface-mount installation
Page 4 of the Siemens DH21400M user manual — E Decreasing the water temperature
Pagina 4 · klik om te vergroten
Pagina 4

Operating instructions

Startup after a water cutoff

  • Disconnect the appliance from the mains supply (remove

Please read and observe the detailed safety instructions at the start of these instructions!

the fuses in the fusebox).

  • Turn on the hot-water tap until the air is purged from the
  • Important: The appliance may never be exposed to frost!

pipe.

Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs.

  • Reinstall the fuses.

The appliance is ready for operation.

  • Immediately shut off the cold water supply to the appli-

Saving energy

ance should it leak.

Use the “e” setting whenever possible. For wash basins: Open the corner valve to such an extent that only the lower heat setting switches on.

Getting to know your appliance

The continuous-flow heater heats the water as it flows through the appliance. The appliance only consumes power during this period.

Winter operation

D Operating elements

The continuous-flow heater has two heat settings: e Economy setting – two thirds power II Intensive setting – full power

  • In order to compensate for this temperature reduction,

please reduce the water quantity on the tap until the re- quired water temperature is achieved.

The e setting is ideal for:

Cleaning

Simply wipe the appliance with a damp cloth. Do not use acidic or abrasive cleaning materials.

The II setting is used in combination with a thermostatically- controlled premixer, for high temperatures or for large vol- umes of water, e. g. for:

After-sales service

If you call the after-sales service for assistance, please specify the E no. and FD no. of your appliance. These numbers are found on the inside of the swing-out con- trol panel of the continuous-flow heater.

Operating the appliance

E Turn on the hot-water tap

The continuous-flow heater switches on and heats the water when the hot-water tap is turned on (Fig. E, 1.).

It switches off again when the tap is turned off.

E Increasing the water temperature

Slightly close the hot-water tap (Fig. E, 2.).

E Decreasing the water temperature

Turn on the cold-water tap (Fig. E, 3.).

Show 6 more labels / short text on this page
Wash basin · Shower · Bidet · Dishwashing · Cleaning · Bath tub
Page 5 of the Siemens DH21400M user manual — Disposal
Pagina 5 · klik om te vergroten
Pagina 5

A fault, what to do?

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service personnel.

FaultCauseSolutionWho Water flow-rate is too low. The appliance does not switch on.The filter in either the water tap or the showerhead is clogged.Remove the filter and either clean it or descale it.Customer The filter in the corner valve is clogged.Get a servicing expert to clean the filter.Servicing expert The corner valve is clogged.Turn on the hot-water tap fully and open and close the corner valve several times. Then clean the filter in the water tap.Customer The water is not sufficiently warm.The fuse in the house electrical installation has tripped/blown.Check the fuse in the fusebox.Customer The appliance‘s automatic circuit breaker has been tripped.Get the appliance‘s automatic circuit breaker checked by an electrician. Check the permissible supply temperature.Servicing expert The power limit has been reached. Water flow-rate is too high and/or the cold water supply temperature is too low.Reduce the flow-rate on the tap.Customer By a qualified professional: use the corner valve to regulate the flow-rate. Check the flow-rate limiter or replace it with a smaller one.Servicing expert The second stage in the appliance does not switch on (the audible “clicking” is missing).Remove the filter in the tap and either clean it or descale it.Customer Clean the filter in the corner valve (Fig. A, 4.).Servicing expert The continuous-flow heater switches off during the drawing-off of water, resulting in a reduction in the water temperature:Swelling seal in the warm water tapA non-swelling sealing material must be used in the warm water tap.Customer Winter operation: The desired water temperature leaving the tap is no longer reached.The supply temperature has reduced.Reduce the water flow on the taps until the desired water temperature is reached.Customer

If the fault could not be eliminated, please call customer service.

Disposal

Guarantee

This appliance is labelled in accordance with Euro- pean Directive 2012/19/EU concerning used elec- trical and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as appli- cable throughout the EU.

The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold.

Details regarding these conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim un- der the terms of this guarantee.

Please ask your specialist retailer about current disposal facilities.

Subject to change without notice.

Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
Water flow-rate is too low. The appliance does not switch on.The filter in either the water tap or the showerhead is clogged.Remove the filter and either clean it or descale it. p.5
Water flow-rate is too low. The appliance does not switch on.The filter in the corner valve is clogged.Get a servicing expert to clean the filter. p.5
Water flow-rate is too low. The appliance does not switch on.The corner valve is clogged.Turn on the hot-water tap fully and open and close the corner valve several times. Then clean the filter in the water tap. p.5
The water is not sufficiently warm.The fuse in the house electrical installation has tripped/blown.Check the fuse in the fusebox. p.5
The water is not sufficiently warm.The appliance‘s automatic circuit breaker has been tripped.Get the appliance‘s automatic circuit breaker checked by an electrician. Check the permissible supply temperature. p.5
The water is not sufficiently warm.The power limit has been reached. Water flow-rate is too high and/or the cold water supply temperature is too low.Reduce the flow-rate on the tap. p.5
The water is not sufficiently warm.By a qualified professional: use the corner valve to regulate the flow-rate. Check the flow-rate limiter or replace it with a smaller one. p.5
The water is not sufficiently warm.The second stage in the appliance does not switch on (the audible “clicking” is missing).Remove the filter in the tap and either clean it or descale it. p.5
The water is not sufficiently warm.Clean the filter in the corner valve (Fig. A, 4.). p.5
The continuous-flow heater switches off during the drawing-off of water, result- ing in a reduction in the water temperature:Swelling seal in the warm water tapA non-swelling sealing material must be used in the warm water tap. p.5
Winter operation: The desired water tempera- ture leaving the tap is no longer reached.The supply temperature has reduced.Reduce the water flow on the taps until the desired water temperature is reached. p.5

Vraag stellen over de Siemens DH21400M

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Siemens DH21400M

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Siemens DH21400M handleiding-pdf

76 pagina's·3.9 MB·Klimaatbeheersing diversen·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…