0805 0810 (F0150805..) (F0150810..)

04/17 2610Z08787 SKIL BV - Konijnenberg 62 4825 BD Breda - The Netherlands




13 mm (½”) 15 mm (5/8”) 19 mm (¾”)



TOOL ELEMENTS 2
A Connection elbow B Universal hose connector C Carrying handle D Float switch E Air bleed valve F Supply power cable G Float switch cable H Cable holder J Fastening screws (3) K Suction base L Cover plate screws (3) (0810) M Cover plate (0810) N Rubber ring (0810)

GENERAL • Regularly clean suction base and motor fan
! ! disconnect the plug before

-- to allow other hose diameters, cut off the nipples of the
universal hose connector as illustrated -- for optimal results use a hose with a diameter of 32
mm (1 1/4") and with a length as short as possible (be aware that after switching off remaining water in the hose will increase the residual water depth) -- when using a 32 mm (1 1/4") or a 25 mm (1") hose, we
recommend to fasten it with an additional hose clamp • Operating the appliance 6
-- place the pump on a firm surface in the water to be
transferred (or use a rope attached to carrying handle C to immerse the pump in a well or shaft) !! ensure that float switch D can move freely -- air may escape through air bleed valve E and air
bubbles may appear underwater -- it may take several seconds for the air to escape when
the pump is immersed for the first time -- wait until the air bubbles have disappeared -- plug power cable F into a mains socket !! connect this earthed appliance only to a properly
earthed power supply system; ensure that socket and extension cable have a functional protective conductor • Automatic mode 6
-- float switch D automatically turns on the pump when
the water level exceeds the switch-on height -- float switch D turns off the pump again when the water
level drops below the switch-off height • Adjusting switch-ON and switch-OFF height 6
-- push float switch cable G into cable holder H -- the shorter the length of the cable between float switch
D and cable holder H, the lower the switch-ON height and the higher the switch-OFF height !! ensure that the cable length between float switch
D and cable holder H is at least 10 cm • Manual mode 7
-- switch on the pump manually by raising float switch D -- be aware that water level must be above 30-40 mm
(0805) / 70-80 mm (0810) to ensure that the pump can draw in water -- fix/hold float switch D vertically above the pump !! as long as the float switch is positioned vertically
above the pump, the pump will continue to operate regardless of the water level -- the minimal residual water depth (approx. 5 mm 0805
/ 35 mm 0810) can only be achieved in manual mode, because the float switch already switches off the pump in an earlier stage when in automatic mode -- observe the pump at all times during manual mode !! immediately unplug the pump when it stops
drawing in water (avoid dry-running operation) • Thermal protection
-- the built-in thermal protection switches off the motor in
the event of overheating -- after a cooling-down phase of approximately 15-30
minutes, the pump switches on automatically
MAINTENANCE / SERVICE
-- screw connection elbow A/hose connector B into
pump outlet -- connect a 25 mm (1") hose to hose connector B