Preserve this handbook for future reference.
An ACOUSTIC PRESSURE value of 4 m. corresponds to the ACOUSTIC POWER value stated on the yellow label located on the compressor, minus 20 dB.

5.2 Fitting the supporting foot (ref. 4) Fit the supplied rubber stopper as shown in Fig. 6.
5.3 Voltage The compressor is equipped with a mains cable with shock-proof plug. This can be connected to any 230V ~ 50Hz shock-proof socket which is protected by a 16 A fuse. Before you use the machine, make sure that the mains voltage complies with the specifications on the rating plate. Long supply cables, extensions, cable reels etc. cause a drop in voltage and can impede motor start-up. In the case of low temperatures below +5°C, motor start-up is jeopardized as a result of stiffness.
Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes.
The machine is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user/ operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.
If for any reason the 13 amp plug fitted to this product requires replacement it must be wired in accordance with the following instruction:
Do not connect the brown (live) or blue (neutral) to
the earth pin marked ‘E’ on the 3 pin plug.
Connect the Blue wire to the terminal marked Neutral (N). Connect the Brown wire to the terminal marked Live (L). Ensure that the outer insulation is gripped by the cord grip and that the wires are not trapped when replacing the plug cover. The mains lead on this product is fitted with a 13 amp (BS1363/A) plug. A 13 amp (BS1362) fuse must be fitted in the plug.
If in doubt consult a qualified electrician

There are no user serviceable parts inside this product except those referred to in the manual. Always refer servicing to qualified service personnel. Never remove any part of the casing unless qualified to do so; this unit contains dangerous voltages.
5.6.1 D 200/8/6 - D 115/8/6 SIL - D 200/8/24 Switch-on pressure 6 bar Switch-off pressure 8 bar
5.6.2 D 200/10/24 - DN 200/10/xx - DN 230/10/xx - D 230/10/50 V
Switch-on pressure 8 bar Switch-off pressure 10 bar
replaced with an identical one and fitted by a qualified person.
5.4.1 D 200/8/24 - D 200/10/24 (Fig. 2a) DN 200/10/xx - DN 230/10/xx (Fig. 2c)
D 230/10/50 V (Fig. 2d) To switch on the equipment set the On/Off switch (ref. 8) to position I. Move the On/Off switch (ref. 8) to position O to switch off the equipment.
5.4.2 D 200/8/6 - D 115/8/6 SIL (Fig. 2b) To switch on the compressor, pull out the red knob (ref. 8) to position I. To switch off the compressor, press the red knob (ref. 8) in again to position O.
6.2 Condensation water The condensation water must be drained off each day by opening the drain valve (ref. 11) (on the bottom of the pressure vessel).
5.6 Setting the pressure switch The pressure switch is set at the factory.
100 HOURS EVERY 100 HOURS
Draining tank condensate Periodically and at the end of work
MAINTENANCE resumptive table

6.3 Safety valve (ref. 10) The safety valve has been set for the highest permitted pressure of the pressure vessel. It is prohibited to adjust the safety valve or remove its seal. Actuate the safety valve from time to time to ensure that it works when required. Pull the ring with sufficient force until you can hear the compressed air being released. Then release the ring again.
The unit and its accessories are made of various types of material, such as metal and plastic. Defective components must be disposed of as special waste. Ask your dealer or your local council.
Leakage of air from the valve of the pressure switch with the compressor off.
Check valve that, due to wear or dirt on the seal, does not perform its function correctly.
Unscrew the hexagonal head of the check valve, clean the valve seat and the special rubber disk (replace if worn). Reassemble and tighten carefully.
Reduction of performance. Frequent start-up. Low pressure values.
Excessive performance request, check for any leaks from the couplings and/or pipes. Intake filter may be clogged.
Replace the seals of the fitting, clean or replace the filter.
The compressor stops and restarts automatically after a few minutes.
Tripping of the thermal cutout due to overheating of the motor.
Clean the air ducts in the conveyor. Ventilate the work area.
After a few attempts to restart, the compressor stops.
Tripping of the thermal cutout due to overheating of the motor (removal of the plug with the compressor running, low power voltage).
Activate the on/off switch. Ventilate the work area. Wait a few minutes. The compressor will restart independently.
The compressor does not stop and the safety valve is tripped.
Irregular functioning of the compressor or breakage of the pressure switch.
Remove the plug and contact the Service Center.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering with the machine may impair its safety and in any case make the warranty null and void.
Fault Cause Remedy