NL
Stanley logo
Officiële handleiding

Stanley MultiLine 77-122

174 pagina's·2.6 MB·Laser·PDF·EN
Stanley MultiLine 77-122
Inhoudsopgave 3 secties 1-77-122 MultiLine - section 1.pdf · 54205 1-77-122 MultiLine Cover v1.pdf · 54205 1-77-122 MultiLine 25Languages.pdf TonenVerbergen
Page 1 of the Stanley MultiLine 77-122 user manual — E
Pagina 1 · klik om te vergroten
Pagina 1

GB

5 - Beam Self-Leveling Multi-Line Laser

MultiLine

F

Stanley MultiLine 77-122 — GB diagram (page 1)
Afb. 1

E

PT

NL

DK

SE

Please read these instructions before operating the product

Self-Leveling

Page 2 of the Stanley MultiLine 77-122 user manual — 54205 1-77-122 MultiLine 25Languages.pdf
Pagina 2 · klik om te vergroten
Pagina 2
Stanley MultiLine 77-122 — 54205 1-77-122 MultiLine 25Languages.pdf diagram (page 2)
Afb. 2 · 54205 1-77-122 MultiLine 25Languages.pdf
1. Safety 2. Product Description 3. Specifications 4. Operating Instructions 5. Calibration 6. Maintenance and Care 7. Warranty

Carefully read the Safety Instructions and User Manual before using this product. The person responsible for the instrument must ensure that all users understand and adhere to these instructions.

MAX OUTPUT ≤ 1 mW @ 630 - 670 nm

Page 3 of the Stanley MultiLine 77-122 user manual — 54205 1-77-122 MultiLine 25Languages.pdf
Pagina 3 · klik om te vergroten
Pagina 3

DO NOT remove any warning label(s) on the housing. This instrument must only be used for leveling and layout tasks as outlined in this manual.

ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser tool.

DO NOT use in combination with other optical instruments. Do not modify the instrument, or make manipulations or use in other applications than those described in the manual.

DO NOT look into the beam with optical aids, such as magnifiers, binoculars or Telescopes.

DO NOT stare into the laser beam or direct it towards other persons. Make sure the instrument is not set at eye level. Eye protection is normally afforded by natural aversion responses such as the blink reflex.

DO NOT direct the laser beam at other persons.

ALWAYS turn the laser tool “OFF” when not in use. Leaving the laser tool “ON” increases the risk of someone inadvertently staring into the laser beam.

DO NOT operate the laser tool in combustible areas such as in the presence of flammable liquids, gases or dust.

DO NOT disassemble the laser tool. There are no user serviceable parts inside. Disassembling the laser will void all warranties on the product. Do not modify the product in any way. Modifying the laser tool may result in hazardous laser radiation exposure.

DO NOT use this instrument in areas where a risk of explosion is present.

3 77-122

Page 4 of the Stanley MultiLine 77-122 user manual — End of Life
Pagina 4 · klik om te vergroten
Pagina 4

Battery Safety

ALWAYS follow all instructions and warnings on the battery label and package.

DO NOT short any battery terminals

DO NOT charge alkaline batteries.

DO NOT mix old and new batteries. Replace all of them at the same time with new batteries of the same brand and type.

DO NOT mix battery chemistries.

DO NOT dispose of batteries in fire.

ALWAYS keep batteries out of reach of children.

ALWAYS remove batteries if the device will not be used for several months.

End of Life

DO NOT dispose of this product with household waste.

ALWAYS dispose of batteries per local code.

PLEASE RECYCLE in line with local provisions for the collection and disposal of electrical and electronic waste under the WEEE Directive.

4 77-122

Page 5 of the Stanley MultiLine 77-122 user manual — Package Contents
Pagina 5 · klik om te vergroten
Pagina 5

Declaration of Conformity

The Stanley Works declares that the CE Mark has been applied to this product in accordance with the CE Marking Directive 93/68/EEC.

This product conforms with EN60825-1:2007.

EN 60825-1

For further details please refer to www.stanleyworks.com

Product Description

Package Contents

1. Laser Unit 2. IR Remote Controller 3. Laser Target 4. Glasses 5. Carrying Case 6. Batteries (Laser Unit - 4 x AA, IR Remote Controller - 2 x AA) 7. User Manual

ROHS Compliant · 5 77-122

Page 6 of the Stanley MultiLine 77-122 user manual — IR Remote Controller
Pagina 6 · klik om te vergroten
Pagina 6

Product Overview

Laser Unit

1. Keyboard 2. Main Power / Transport Lock 3. Fine Tuning Wheel 4. Window for 90° Vertical Reference Beam Laser 5. Window for Front Vertical Beam Laser 6. Window for Horizontal Beam Laser 7. IR Sensor 8. Bubble Level
9. Window for Rear Vertical Beam Laser 10. Laser Warning Label Battery Compartment Cover 11. Handle 12. Window for 90° Vertical Reference Beam Laser
13. Adjustable Legs 3x 14. 5/8 - 11 Threaded Mount Window for Down Beam Laser

IR Remote Controller

1. IR LED 2. Keyboard 3. Location for Lanyard 4. Battery Compartment Cover

6 77-122

Page 7 of the Stanley MultiLine 77-122 user manual — IP54
Pagina 7 · klik om te vergroten
Pagina 7

Specifications

Laser Unit

Leveling Accuracy:

≤ 2 mm / 10 m (≤ 5/64 in / 30 ft)

Down Beam Accuracy:

≤ 1 mm / 1.5 m (≤ 1/32 in / 5 ft)

Square Beam Accuracy:

≤ 1 mm / 5 m (≤ 1/32 in / 15 ft)

Horizontal / Vertical Accurracy

≤ 2 mm / 10 m (≤ 5/64 in / 30 ft)

Working Range:

Self-Leveling to ± 3°

Working Distancewith Laser Detector:

≤ 15 m (≤ 50 ft) ≤ 50 m (≤ 165 ft)

Laser Class:

Laser Wavelength:

635 nm ± 5 nm

Operating Time:

Power Voltage:

Power Supply:

4 x AA Batteries (Alkaline)

IP Rating:

IP54

Operating Temperature Range:

-10° C to +40° C (+14° F to +104° F)

Storage Temperature Range:

-20° C to +60° C (-4° F to +140° F)

Weight (without Base and Batteries):

980 g (34,5 oz)

Class 1M · 6 h · 7 77-122

Page 8 of the Stanley MultiLine 77-122 user manual — IR Remote Controller
Pagina 8 · klik om te vergroten
Pagina 8

110 mm × 105 mm × 180 mm (4 5/16 in × 4 1/8 in × 7 1/16 in) Size:

IR Remote Controller

Power Voltage:

Power Supply:

2 x AA Batteries (Alkaline)

Weight (without Batteries):

37 g (1,3 oz)

Size:

35 mm × 25 mm × 120 mm (1 3/8 in × 1 in × 4 3/4 in)

8 77-122

Page 9 of the Stanley MultiLine 77-122 user manual — Laser Unit
Pagina 9 · klik om te vergroten
Pagina 9

Operating Instructions

Laser Unit

Battery Installation / Removal

1. Turn laser unit to back. Open battery compartment cover by pressing and sliding out.
2. Install / Remove batteries. Orient batteries correctly when placing into laser unit.
3. Close and lock battery compartment cover by sliding in until securely closed.
Show 5 more labels / short text on this page
+ · + · - + · + · 9 77-122
Page 10 of the Stanley MultiLine 77-122 user manual — Function
Pagina 10 · klik om te vergroten
Pagina 10

Function

1. Transport lock in locked position. Laser power is OFF.
2. Transport lock in unlocked position. Laser power is ON. Down laser beam and horizontal laser beam turn on. Left LED indicator lights green when laser power is on.
3. Press laser mode key to toggle through available laser modes - horizontal only, both horizontal and vertical, horizontal and vertical with left and right 90° vertical reference beam, horizontal with all 4 vertical.
4. Press pulse mode key to toggle between pulse mode ON and OFF. Indicator LED lights green when on. Pulse mode allows use with a laser detector.
5. Laser beam(s) blink to indicate the laser unit is out of the working range. Reposition laser unit to be more level.
Show 5 more labels / short text on this page
Locked · Unlocked · Laser Mode · Pulse Mode · 10 77-122
Page 11 of the Stanley MultiLine 77-122 user manual — Laser Unit Base
Pagina 11 · klik om te vergroten
Pagina 11
8. Low battery - Left LED blinks red to indicate when battery power is low. Replace batteries.

Laser Unit Base

1. Turn any of the adjustable legs as needed to level the laser unit within its workable range. Use the bubble vial for reference.
2. Use fine adjustment wheel to gradually rotate the projection of the laser beam(s).
3. 5/8 - 11 thread mount available for optional accessories.

Standard Mount for Optional Tripod Mounting

Bubble Vial · 5/8 in · 11 77-122

Page 12 of the Stanley MultiLine 77-122 user manual — Function
Pagina 12 · klik om te vergroten
Pagina 12

IR Remote Controller

Battery Installation / Removal

1. Turn laser unit to back. Open battery compartment cover by pressing and sliding out.
2. Install / Remove batteries. Orient batteries correctly when placing into laser unit.
3. Close and lock battery compartment cover by sliding in until securely closed.

Function

1. Aim remote controller towards laser unit and press laser mode key to toggle through available laser modes.
2. Press pulse mode key to toggle between pulse mode ON and OFF.
Show 5 more labels / short text on this page
+ · + - · Laser Mode · Pulse Mode · 12 77-122
Page 13 of the Stanley MultiLine 77-122 user manual — Applications
Pagina 13 · klik om te vergroten
Pagina 13

Applications

1. Plumb: Using the vertical laser beam, establish a vertical reference plane. Position the desired object(s) until they are aligned with the vertical reference plane to ensure object(s) are plumb. Establish 2 reference points that need to be plumb. Align either the down laser beam or the up laser cross to a set reference point. The opposing laser beam(s) will be projecting a point which is plumb. Position the desired object until the laser beam is aligned with the second reference point that needs to be plumb with the set reference point.

2. Level: Using the horizontal laser beam, establish a horizontal reference plane. Position the desired object(s) until they are aligned with the horizontal reference plane to ensure object(s) are level.
3. Square: Using either the vertical and horizontal laser beams with or without the 90° vertical reference laser beam, establish a point where the vertical and horizontal beams cross. Position the desired object(s) until they are aligned with both the vertical and horizontal laser beams to ensure object(s) are square.
4. Pulse Mode: Setting laser unit to pulse mode allows use of optional laser detectors.

13 77-122

Page 14 of the Stanley MultiLine 77-122 user manual — Level Beam Accuracy
Pagina 14 · klik om te vergroten
Pagina 14

Calibration

Level Beam Accuracy

Stanley MultiLine 77-122 — Level Beam Accuracy diagram (page 14)
Afb. 3 · Level Beam Accuracy
1. Place laser unit as shown with laser ON. Mark point P 1 at cross.
2. Rotate laser unit 180° and mark point P 2 at cross.
3. Move laser unit close to wall and mark point P 3 at cross.
4. Rotate laser unit 180° and mark point P 4 at cross.
Page 15 of the Stanley MultiLine 77-122 user manual — P 1
Pagina 15 · klik om te vergroten
Pagina 15

(DP1 - DP3 ) = D3 P4

5. Measure the vertical distance from the floor to each point. Calculate the difference between distances D P1 and D P3 to get D 3 and distances D P2 and D P4 to get D 4 .

P 1

P 2

P 3

D P2 D P4

D P1

D P3

(DP2 - DP4 ) = D4

6. Calculate the maximum allowed offset distance and compare to the difference of D 3 and D 4 as shown in the equation. If the sum is not less than or equal to the calculated maximum offset distance the unit must be returned to your Stanley Distributor.

Maximum Offset Distance:

m = 0,2 x (D1 m - (2 x D2 m))

Max in ft = 0,0024 x (D1 ft - (2 x D2 ft))

CompareD 3 - D 4 ≤ ± Max
ExampleD 1 = 10 m, D 2 = 0,5 m

DP1 = 30,75 mm, DP2 = 29 mm, DP3 = 30 mm, DP4 = 29,75 mm D3 = (30,75 mm - 30 mm) = 0,75 mm D4 = (29 mm - 29,75 mm) = - 0,75 mm 0,2 x (10 m - (2 x 0,5 m) = 1,8 mm (maximum allowed offset distance) (0,75 mm) - (- 0,75 mm) = 1,5 mm 1,5 mm ≤ 1,8 mm (TRUE, unit is within calibration)

Horizontal Beam Accuracy

1. Place laser unit as shown with horizontal, vertical, and both 90° vertical reference laser beams ON. Mark point P 1 where the horizontal and left 90° vertical reference laser beams cross.

P 1

Show 4 more labels / short text on this page
mm · mm · m · 15 77-122
Page 16 of the Stanley MultiLine 77-122 user manual — P 2 D 2
Pagina 16 · klik om te vergroten
Pagina 16
2. Rotate laser unit 90° and align front vertical laser beam with point P 1 . Mark point P 2 where the horizontal and front vertical laser beams cross.

P 1

P 2

3. Rotate laser unit 90° and align right 90° vertical reference laser beam with point P 1 . Mark point P 3 where the horizontal and right 90° vertical reference laser beams cross.

P 1

P 2

P 3

P 1

4. Measure the vertical distance D 2 between the highest and lowest point .

P 2 D 2

P 3

Maximum Offset Distance:

5. Calculate the maximum allowed offset distance and compare to D 2 . If D 2 is not less than or equal to the calculated maximum offset distance the unit must be returned to your Stanley Distributor. Compare: D 2 ≤ Max

m = 0,2 x D1 m

Max in ft = 0,0024 x D1 ft

ExampleD 1 = 5 m, D 2 = 1 mm

0,2 x 5 m = 1 mm (maximum allowed offset distance) 1 mm ≤ 1 mm (TRUE, unit is within calibration)

Show 4 more labels / short text on this page
mm · mm · m · 16 77-122
Page 17 of the Stanley MultiLine 77-122 user manual — P 1
Pagina 17 · klik om te vergroten
Pagina 17

Vertical Beam Accuracy

1. Measure the height of a door jamb or reference point to get distance D 1 . Place laser unit as shown with laser ON. Aim vertical beam towards door jamb or reference point. Mark points P 1 , P 2 , and P 3 as shown.

P 1

D 1 P 2 P 3

2 x D1

P 4

P 1

2. Move laser unit to opposite side of door jamb or reference point and align vertical beam with P 2 and P 3 .

D 1 P 2 P 3

2 x D1

3. Measure the horizontal distances between P 1 and the vertical beam from the 2nd location.

P 1

Maximum Offset Distance:

4. Calculate the maximum allowed offset distance and compare to D 2 . If D 2 is not less than or equal to the calculated maximum offset distance the unit must be returned to your Stanley Distributor. Compare: D 2 ≤ Max

m = 0,4 x D1 m

Max in ft = 0,0048 x D1 ft

ExampleD 1 = 2 m, D 2 = 0,5 mm

0,4 x 2 m = 0,8 mm (maximum allowed offset distance) 0,5 mm ≤ 0,8 mm (TRUE, unit is within calibration)

Show 6 more labels / short text on this page
Vertical · Beam · mm · mm · m · 17 77-122
Page 18 of the Stanley MultiLine 77-122 user manual — P 2
Pagina 18 · klik om te vergroten
Pagina 18

90 ° Vertical Beam Accuracy

You will need at least 1,5 m2 (16 ft2) of floor space and possibly an assistant for this check.

1. Place the laser unit on a level floor, and turn on all beams.

P 1

2. Measure exactly 0,91 m (3 ft) out from the center of the laser unit along the front vertical laser beam. Mark this point P 1 .

0,91 m (3 ft)

P 1

3. Measure exactly 1,22 m (4 ft) out the center of the instrument along either of the 90° vertical reference beams, and mark this point P 2 .

1,22 m (4 ft)

P 2

P 1

4. Measure from point A to point B; this distance D 1 should equal 1,522 m ± 0,3 mm (5 ft ± 1/64 in). If not, the unit must be returned to your Stanley Distributor.
5. Repeat steps 1 through 4 to check the other beams.

P 2

18 77-122

Page 19 of the Stanley MultiLine 77-122 user manual — Maintenance and Care
Pagina 19 · klik om te vergroten
Pagina 19

Maintenance and Care

Laser unit is not waterproof. DO NOT allow to get wet. Damage to internal circuits may result.

DO NOT leave laser unit in direct sunlight or expose it to high temperatures. The housing and some internal parts are made of plastic and may become deformed at high temperatures.

DO NOT store the laser unit in a cold environment. Moisture may form on interior parts when warming up. This moisture could fog up laser windows and cause corrosion of internal circuit boards.

When working in dusty locations, some dirt may collect on the laser window. Remove any moisture or dirt with a soft, dry cloth.

DO NOT use aggressive cleaning agents or solvents.

Store the laser unit in its case when not in use. If storing for extended time, remove batteries before storage to prevent possible damage to the instrument.

19 77-122

Page 20 of the Stanley MultiLine 77-122 user manual — One Year Warranty
Pagina 20 · klik om te vergroten
Pagina 20

Warranty

One Year Warranty

Stanley Tools warrants its electronic measuring tools against deficiencies in materials and/or workmanship for one year from date of purchase.

Deficient products will be repaired or replaced, at Stanley Tools’ option, if sent together with proof of purchase to:

Stanley UK Sales Limited Gowerton Road Brackmills, Northampton NN4 7BW

This Warranty does not cover deficiencies caused by accidental damage, wear and tear, use other than in accordance with the manufacturer’s instructions or repair or alteration of this product not authorised by Stanley Tools.

Repair or replacement under this Warranty does not affect the expiry date of the Warranty.

To the extent permitted by law, Stanley Tools shall not be liable under this Warranty for indirect or consequential loss resulting from deficiencies in this product.

This Warranty may not be varied without the authorisation of Stanley Tools.

This Warranty does not affect the statutory rights of consumer purchasers of this product.

This Warranty shall be governed by and construed in accordance with the laws of England and Stanley Tools and the purchaser each irrevocably agrees to submit to the exclusive jurisdiction of the courts of England over any claim or matter arising under or in connection with this Warranty.

Calibration and care are not covered by warranty.

Subject to change without notice

20 77-122

Vraag stellen over de Stanley MultiLine 77-122

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Stanley MultiLine 77-122

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Stanley MultiLine 77-122 handleiding-pdf

174 pagina's·2.6 MB·Laser·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…