5 - Beam Self-Leveling Multi-Line Laser
MultiLine
F

PT
NL
DK
SE
Please read these instructions before operating the product
Self-Leveling


Carefully read the Safety Instructions and User Manual before using this product. The person responsible for the instrument must ensure that all users understand and adhere to these instructions.
MAX OUTPUT ≤ 1 mW @ 630 - 670 nm

DO NOT remove any warning label(s) on the housing. This instrument must only be used for leveling and layout tasks as outlined in this manual.
ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser tool.
DO NOT use in combination with other optical instruments. Do not modify the instrument, or make manipulations or use in other applications than those described in the manual.
DO NOT look into the beam with optical aids, such as magnifiers, binoculars or Telescopes.
DO NOT stare into the laser beam or direct it towards other persons. Make sure the instrument is not set at eye level. Eye protection is normally afforded by natural aversion responses such as the blink reflex.
DO NOT direct the laser beam at other persons.
ALWAYS turn the laser tool “OFF” when not in use. Leaving the laser tool “ON” increases the risk of someone inadvertently staring into the laser beam.
DO NOT operate the laser tool in combustible areas such as in the presence of flammable liquids, gases or dust.
DO NOT disassemble the laser tool. There are no user serviceable parts inside. Disassembling the laser will void all warranties on the product. Do not modify the product in any way. Modifying the laser tool may result in hazardous laser radiation exposure.
DO NOT use this instrument in areas where a risk of explosion is present.
3 77-122

ALWAYS follow all instructions and warnings on the battery label and package.
DO NOT short any battery terminals
DO NOT charge alkaline batteries.
DO NOT mix old and new batteries. Replace all of them at the same time with new batteries of the same brand and type.
DO NOT mix battery chemistries.
DO NOT dispose of batteries in fire.
ALWAYS keep batteries out of reach of children.
ALWAYS remove batteries if the device will not be used for several months.
DO NOT dispose of this product with household waste.
ALWAYS dispose of batteries per local code.
PLEASE RECYCLE in line with local provisions for the collection and disposal of electrical and electronic waste under the WEEE Directive.
4 77-122

The Stanley Works declares that the CE Mark has been applied to this product in accordance with the CE Marking Directive 93/68/EEC.
This product conforms with EN60825-1:2007.
For further details please refer to www.stanleyworks.com
ROHS Compliant · 5 77-122

Laser Unit
6 77-122

Leveling Accuracy:
≤ 2 mm / 10 m (≤ 5/64 in / 30 ft)
Down Beam Accuracy:
≤ 1 mm / 1.5 m (≤ 1/32 in / 5 ft)
Square Beam Accuracy:
≤ 1 mm / 5 m (≤ 1/32 in / 15 ft)
Horizontal / Vertical Accurracy
≤ 2 mm / 10 m (≤ 5/64 in / 30 ft)
Working Range:
Self-Leveling to ± 3°
≤ 15 m (≤ 50 ft) ≤ 50 m (≤ 165 ft)
Laser Class:
Laser Wavelength:
635 nm ± 5 nm
Operating Time:
Power Voltage:
Power Supply:
4 x AA Batteries (Alkaline)
IP Rating:
Operating Temperature Range:
-10° C to +40° C (+14° F to +104° F)
Storage Temperature Range:
-20° C to +60° C (-4° F to +140° F)
Weight (without Base and Batteries):
980 g (34,5 oz)
Class 1M · 6 h · 7 77-122

110 mm × 105 mm × 180 mm (4 5/16 in × 4 1/8 in × 7 1/16 in) Size:
Power Voltage:
Power Supply:
2 x AA Batteries (Alkaline)
Weight (without Batteries):
37 g (1,3 oz)
Size:
35 mm × 25 mm × 120 mm (1 3/8 in × 1 in × 4 3/4 in)
8 77-122

Battery Installation / Removal


Standard Mount for Optional Tripod Mounting
Bubble Vial · 5/8 in · 11 77-122

Battery Installation / Removal

1. Plumb: Using the vertical laser beam, establish a vertical reference plane. Position the desired object(s) until they are aligned with the vertical reference plane to ensure object(s) are plumb. Establish 2 reference points that need to be plumb. Align either the down laser beam or the up laser cross to a set reference point. The opposing laser beam(s) will be projecting a point which is plumb. Position the desired object until the laser beam is aligned with the second reference point that needs to be plumb with the set reference point.
13 77-122



(DP1 - DP3 ) = D3 P4
P 2
P 3
D P2 D P4
D P1
D P3
(DP2 - DP4 ) = D4
Maximum Offset Distance:
m = 0,2 x (D1 m - (2 x D2 m))
Max in ft = 0,0024 x (D1 ft - (2 x D2 ft))
DP1 = 30,75 mm, DP2 = 29 mm, DP3 = 30 mm, DP4 = 29,75 mm D3 = (30,75 mm - 30 mm) = 0,75 mm D4 = (29 mm - 29,75 mm) = - 0,75 mm 0,2 x (10 m - (2 x 0,5 m) = 1,8 mm (maximum allowed offset distance) (0,75 mm) - (- 0,75 mm) = 1,5 mm 1,5 mm ≤ 1,8 mm (TRUE, unit is within calibration)

P 2
P 2
P 3
P 1
P 3
Maximum Offset Distance:
m = 0,2 x D1 m
Max in ft = 0,0024 x D1 ft
0,2 x 5 m = 1 mm (maximum allowed offset distance) 1 mm ≤ 1 mm (TRUE, unit is within calibration)

D 1 P 2 P 3
2 x D1
P 1
2 x D1
Maximum Offset Distance:
m = 0,4 x D1 m
Max in ft = 0,0048 x D1 ft
0,4 x 2 m = 0,8 mm (maximum allowed offset distance) 0,5 mm ≤ 0,8 mm (TRUE, unit is within calibration)

You will need at least 1,5 m2 (16 ft2) of floor space and possibly an assistant for this check.
0,91 m (3 ft)
1,22 m (4 ft)
P 1
18 77-122

Laser unit is not waterproof. DO NOT allow to get wet. Damage to internal circuits may result.
DO NOT leave laser unit in direct sunlight or expose it to high temperatures. The housing and some internal parts are made of plastic and may become deformed at high temperatures.
DO NOT store the laser unit in a cold environment. Moisture may form on interior parts when warming up. This moisture could fog up laser windows and cause corrosion of internal circuit boards.
When working in dusty locations, some dirt may collect on the laser window. Remove any moisture or dirt with a soft, dry cloth.
DO NOT use aggressive cleaning agents or solvents.
Store the laser unit in its case when not in use. If storing for extended time, remove batteries before storage to prevent possible damage to the instrument.
19 77-122

Stanley Tools warrants its electronic measuring tools against deficiencies in materials and/or workmanship for one year from date of purchase.
Deficient products will be repaired or replaced, at Stanley Tools’ option, if sent together with proof of purchase to:
Stanley UK Sales Limited Gowerton Road Brackmills, Northampton NN4 7BW
This Warranty does not cover deficiencies caused by accidental damage, wear and tear, use other than in accordance with the manufacturer’s instructions or repair or alteration of this product not authorised by Stanley Tools.
Repair or replacement under this Warranty does not affect the expiry date of the Warranty.
To the extent permitted by law, Stanley Tools shall not be liable under this Warranty for indirect or consequential loss resulting from deficiencies in this product.
This Warranty may not be varied without the authorisation of Stanley Tools.
This Warranty does not affect the statutory rights of consumer purchasers of this product.
This Warranty shall be governed by and construed in accordance with the laws of England and Stanley Tools and the purchaser each irrevocably agrees to submit to the exclusive jurisdiction of the courts of England over any claim or matter arising under or in connection with this Warranty.
Calibration and care are not covered by warranty.
Subject to change without notice