Auto-Levelling









RL HW RL HW+
E 2


E 3
E 4
3 77-496 / 77-429 / 77-439 / 77-497 / 77-427


(+)
F

(-)


G H






M





Figure J - Bracket Accessory
Figure M - Spot and / or Scan Rotation Direction
Figure P - Vertical Check Setup
Feature Set


Keypad, LED, and LCD (See fi gure E to reference keypad display for each laser tool model)
RL HV / RL HVPW (See Figure E3 )
Power ON / OFF Key
Tilt Warning ON / OFF Key
RL HW (See Figure E1 )
Power ON / OFF Key
Tilt Warning ON / OFF Key
Manual Slope Mode Key
Scan, Spot, Slope and Calibration Adjust Keys
RL HGW (See Figure E4 )
RL HW+ (See Figure E2 )
Power ON / OFF Key
Power ON / OFF Key
Tilt Warning ON / OFF Key
Tilt Warning ON / OFF Key
Manual Slope Mode Key
Auto-Levelling / Manual Slope Mode Key
Scan, Spot, Slope and Calibration Adjust Keys

LCD Icons
Manual Icon - Blinking • Manual Mode ON (Auto-Levelling OFF)
Manual LED - Blinking RED • Manual Mode ON (Auto-Levelling OFF)
Manual LED - Blinking RED with Power LED - Blinking GREEN • Out of Compensation Range
Rotation Icon with Speed Value • Speed Setting
X / Y Icon Only - Blinking • Adjust Shown Axis in Manual Slope and / or Calibration Mode
X / Y Icon with Value - Value Blinking • Adjust Shown Value in Auto-Levelling Slope Mode
Vertical Position Icon - Solid • Shown when Laser Tool is in Vertical Position

Battery Installation / Removal (See fi gure F and G to reference battery location of laser tool and remote control)
Positioning (See Feature Set to reference which models offer Auto- Levelling in the given positions)
Horizontal Position (See fi gure A ) • Place laser tool down on its bottom. Be sure surface is
near level. Press
to power ON.
Vertical Position (See fi gure B ) • Place laser tool down on its side, handle facing up. Be
sure surface is near level. Press
to power ON.

(The Alignment Sight on the top cover of the laser tool can be used for models that do not include the Sighting Telescope)
to turn ON Manual Mode. Laser tool can now be positioned to various angles with auto-levelling mode OFF.
to power ON. Press and hold
Mounting and Use (See fi gure C ) • Loosen both locking screws on sighting telescope. Guide scope onto the mount base located on top of the laser tool with the objective (smaller end) towards the target (
At Angle

Calibration Mode - see Accuracy Check and Calibration section
(For RL HW / RL HW+ substitute
. Manual Mode turns ON, Auto-Levelling OFF.
Tilt Warning (not available in Manual Mode) • When powered ON, Tilt Warning is ON by default.
needs to be pressed and held for ≥ 3 seconds to enter Manual Mode prior to pressing
to turn Tilt Warning ON / OFF. • With Tilt Warning ON, laser tool will indicate with LED / LCD and blinking laser beam when the laser tool has sensed any movement.
to adjust axis. • LED / LCD will indicate when at maximum slope angle. The axis will not move any further in that direction.
to reset. • When reset, the laser tool begins Auto-Levelling. Check alignment with original target.
Tilt Warning Default Setting
again to set the “X” axis and / or proceed to the “Y” axis adjust.
to adjust axis. • LED / LCD will indicate when at maximum slope angle. The axis will not move any further in that direction.
again to set the “Y” axis and / or proceed to use of laser tool in Manual Slope Mode. • “X” and “Y” axis are now set at manually adjusted slopes.
for ≥ 3 seconds. • When Manual Mode is turned OFF, laser tool begins Auto-Levelling as done when initially powered ON.
for ≥ 3 seconds to turn ON / OFF Manual Mode. • Auto-Levelling is OFF in Manual Mode.

NOTE:
to toggle through the available speed settings from fastest to slowest to stopped.
Digital Slope Mode (with Auto-Levelling)
to adjust axis value. • LCD will indicate when at maximum slope angle. The value will not continue any further in that direction.
to stopped (0 RPM) setting.
to rotate the direction of the spot.
again to set the “X” axis and / or proceed to the “Y” axis value adjust.
to adjust axis value. • LCD will indicate when at maximum slope angle. The value will not continue any further in that direction.
to cycle through available scan angles (15° / 45° / 90°).
needs to be cycled. Press
2x to power OFF and back ON.
to rotate the direction of the scan.
to turn OFF Scan Mode and return to the last used speed setting.
will change the value by 0,01%. • Holding the key down will move the value continuously, slowly at fi rst, followed by a faster rate when held for an extended time.
Speed · Spot Mode · Scan Mode

(For RL HW substitute
at the same time. The laser tool can only be powered ON with the power key on the laser tool.
(For RL HW / RL HW+ substitute
for ≥ 3 seconds.
and continue to hold
. • The LED/LCD will indicate laser tool is in Calibration mode.
until the laser beam is aligned with “D0”. “D0” is the halfway point between “D1” and “D2” during “X” axis check.
again to set the “X” axis and / or proceed to the “Y” axis adjust.
until the laser beam is aligned with “D0”. “D0” is the halfway point between “D1” and “D2” during “Y” axis check.
again to set the “X” axis and / or proceed to

exit Calibration Mode. • Axis settings are now saved, Calibration Mode is OFF, and laser tool begins Auto-Levelling as done when initially powered ON.
for ≥ 3 seconds.
and continue to hold
will slope the axis by 3,5 arc seconds. Reference Figure L for resulting slope direction for each key. • If the laser tool can still not be calibrated after following the Calibration procedure, please send the laser tool into an Authorized Service Center for repair.
until the laser beam is aligned with “D0”. “D0” is the halfway point between “D1” and “D2” during vertical axis check. • .
to set the vertical “X” axis. • Axis setting is now saved, Calibration Mode is OFF, and laser tool begins Auto-Levelling as done when initially powered ON. NOTE:
(Only necessary on models with Vertical Auto-Levelling)
will slope the axis by 3,5 arc seconds. Reference Figure L for resulting slope direction for each key. • If the laser tool can still not be calibrated after following the Calibration procedure, please send the laser tool into an Authorized Service Center for repair.
(For RL HW+ substitute
is referenced below) · where ever · followed by

Laser Tool

RL HW RL HW+ RL HGW RL HV RL HVPW

40 m 2 x AAA Batteries (Alkaline)
2,5 x 5° 36’
8 mm 32 mm ≤ 8° 85 mm
Infrared