NL
Stanley logo
Officiële handleiding

Stanley SLP3

212 pagina's·3 MB·Laser·PDF·EN
Stanley SLP3
Inhoudsopgave 80 secties GB · 3 / 5 - Beam Self-Levelling Spot Laser · (SLP5 with additional Horizontal Level Line) · SLP3 / SLP5 · … TonenVerbergen
GBp.13 / 5 - Beam Self-Levelling Spot Laserp.1(SLP5 with additional Horizontal Level Line)p.1SLP3 / SLP5p.1PTp.1NLp.1DKp.1SEp.1FINp.1NOp.1PLp.1GRp.1CZp.1RUp.1HUp.1SKp.1SIp.1BGp.1ROp.1EEp.177-318 / 77-319p.1LTp.1HRp.1Please read these instructions before operating the productp.1Self-Levellingp.1TRp.1SLP3 B 1p.2SLP5 B 2p.22 77-318 / 77-319p.23 77-318 / 77-319p.3360°p.4G 2p.4G G 1p.4H 1 H 2p.44 77-318 / 77-319 Hp.4SLP3p.5SLP5p.5K Lp.55 77-318 / 77-319p.5M 1 M 2p.6M 3p.66 77-318 / 77-319p.6N 1 N 2p.7N 3 N 4p.77 77-318 / 77-319 Np.7P 1 P 2p.88 77-318 / 77-319p.8R 1 R 2p.99 77-318 / 77-319p.9S 1 S 2p.10S 3 S 4p.1010 77-318 / 77-319p.10T 1 T 2p.11P 2 D 2p.11T 4 T 3p.1111 77-318 / 77-319p.11Contentsp.12DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 2 LASER PRODUCTp.12EN 60825-1p.12Product Overviewp.12Figure A - Laser Toolp.12User Safetyp.12Figure B - Keypad Confi gurationsp.12Figure C - Laser Tool Battery Locationp.12Figure D - Laser Tool Bottomp.12Figure E - Laser Tool on Tripod / Attachmentp.1212 77-318 / 77-319p.12Figure F - Laser Tool on Key Hole Slotp.13LEDs (See fi gure B )p.13Figure G - Laser Tool on Magnetic Mountp.13Figure H - Pendulum / Transport Lock Positionsp.13Figure J - Laser Modesp.13Figure K - Up / Down Beam Aligned to Lower Basep.13Figure L - Manual Modep.13Figure M - Up and Down Beam Accuracyp.13Batteries and Powerp.13Figure N - Level Beam Accuracy (for Single Beam)p.13Battery Installation / Removal (See fi gure C )p.13Figure P - Level Beam Accuracy (for Multiple Beams)p.13Figure R - 90° Square Beam Accuracyp.13
Page 1 of the Stanley SLP3 user manual — SE
Pagina 1 · klik om te vergroten
Pagina 1

GB

F

3 / 5 - Beam Self-Levelling Spot Laser

E

(SLP5 with additional Horizontal Level Line)

SLP3 / SLP5

PT

NL

DK

Stanley SLP3 — GB diagram (page 1)
Afb. 1

SE

FIN

NO

PL

GR

CZ

RU

HU

SK

SI

BG

RO

EE

77-318 / 77-319

LT

HR

Please read these instructions before operating the product

Self-Levelling

TR

Page 2 of the Stanley SLP3 user manual — 2 77-318 / 77-319
Pagina 2 · klik om te vergroten
Pagina 2
Stanley SLP3 — SLP3 B 1 diagram (page 2)
Afb. 2
Stanley SLP3 — SLP3 B 1 diagram (page 2)
Afb. 3

A

SLP3 B 1

B

SLP5 B 2

Stanley SLP3 — SLP3 B 1 diagram (page 2)
Afb. 4

2 77-318 / 77-319

(-) (+) · (+) · (-) (+) (-)

Page 3 of the Stanley SLP3 user manual — 3 77-318 / 77-319
Pagina 3 · klik om te vergroten
Pagina 3
Stanley SLP3 — 3 77-318 / 77-319 diagram (page 3)
Afb. 5
Stanley SLP3 — 3 77-318 / 77-319 diagram (page 3)
Afb. 6

E

Stanley SLP3 — E diagram (page 3)
Afb. 7

F

3 77-318 / 77-319

Page 4 of the Stanley SLP3 user manual — H 1 H 2
Pagina 4 · klik om te vergroten
Pagina 4
Stanley SLP3 — 360° diagram (page 4)
Afb. 8
Stanley SLP3 — 360° diagram (page 4)
Afb. 9

360°

G 2

G G 1

Stanley SLP3 — 360° diagram (page 4)
Afb. 10
Stanley SLP3 — 360° diagram (page 4)
Afb. 11

H 1 H 2

4 77-318 / 77-319 H

Page 5 of the Stanley SLP3 user manual — 5 77-318 / 77-319
Pagina 5 · klik om te vergroten
Pagina 5

SLP3

SLP5

SLP5

SLP5

J

Stanley SLP3 — SLP3 diagram (page 5)
Afb. 12

K L

5 77-318 / 77-319

Page 6 of the Stanley SLP3 user manual — M 1 M 2
Pagina 6 · klik om te vergroten
Pagina 6

M 1 M 2

M 3

M

6 77-318 / 77-319

Page 7 of the Stanley SLP3 user manual — 7 77-318 / 77-319 N
Pagina 7 · klik om te vergroten
Pagina 7
Stanley SLP3 — N 1 N 2 diagram (page 7)
Afb. 13
Stanley SLP3 — N 1 N 2 diagram (page 7)
Afb. 14

N 1 N 2

Stanley SLP3 — N 1 N 2 diagram (page 7)
Afb. 15
Stanley SLP3 — N 1 N 2 diagram (page 7)
Afb. 16

N 3 N 4

Stanley SLP3 — N 3 N 4 diagram (page 7)
Afb. 17

7 77-318 / 77-319 N

Page 8 of the Stanley SLP3 user manual — 8 77-318 / 77-319
Pagina 8 · klik om te vergroten
Pagina 8
Stanley SLP3 — P 1 P 2 diagram (page 8)
Afb. 18
Stanley SLP3 — P 1 P 2 diagram (page 8)
Afb. 19

P 1 P 2

Stanley SLP3 — P 1 P 2 diagram (page 8)
Afb. 20
Stanley SLP3 — P 1 P 2 diagram (page 8)
Afb. 21

8 77-318 / 77-319

Page 9 of the Stanley SLP3 user manual — 9 77-318 / 77-319
Pagina 9 · klik om te vergroten
Pagina 9
Stanley SLP3 — R 1 R 2 diagram (page 9)
Afb. 22
Stanley SLP3 — R 1 R 2 diagram (page 9)
Afb. 23

R 1 R 2

Stanley SLP3 — R 1 R 2 diagram (page 9)
Afb. 24
Stanley SLP3 — R 1 R 2 diagram (page 9)
Afb. 25

9 77-318 / 77-319

Page 10 of the Stanley SLP3 user manual — 10 77-318 / 77-319
Pagina 10 · klik om te vergroten
Pagina 10
Stanley SLP3 — S 1 S 2 diagram (page 10)
Afb. 26
Stanley SLP3 — S 1 S 2 diagram (page 10)
Afb. 27

S 1 S 2

Stanley SLP3 — S 1 S 2 diagram (page 10)
Afb. 28
Stanley SLP3 — S 1 S 2 diagram (page 10)
Afb. 29

S 3 S 4

Stanley SLP3 — S 3 S 4 diagram (page 10)
Afb. 30

S

10 77-318 / 77-319

Page 11 of the Stanley SLP3 user manual — T 1 T 2
Pagina 11 · klik om te vergroten
Pagina 11

T 1 T 2

P 2 D 2

T 4 T 3

T

11 77-318 / 77-319

Page 12 of the Stanley SLP3 user manual — Inhoudsopgave
Pagina 12 · Inhoud
Inhoud

Inhoud

GBp.13 / 5 - Beam Self-Levelling Spot Laserp.1(SLP5 with additional Horizontal Level Line)p.1SLP3 / SLP5p.1PTp.1NLp.1DKp.1SEp.1FINp.1NOp.1PLp.1GRp.1CZp.1RUp.1HUp.1SKp.1SIp.1BGp.1ROp.1EEp.177-318 / 77-319p.1LTp.1HRp.1Please read these instructions before operating the productp.1Self-Levellingp.1TRp.1SLP3 B 1p.2SLP5 B 2p.22 77-318 / 77-319p.23 77-318 / 77-319p.3360°p.4G 2p.4G G 1p.4H 1 H 2p.44 77-318 / 77-319 Hp.4SLP3p.5SLP5p.5K Lp.55 77-318 / 77-319p.5M 1 M 2p.6M 3p.66 77-318 / 77-319p.6N 1 N 2p.7N 3 N 4p.77 77-318 / 77-319 Np.7P 1 P 2p.88 77-318 / 77-319p.8R 1 R 2p.99 77-318 / 77-319p.9S 1 S 2p.10S 3 S 4p.1010 77-318 / 77-319p.10T 1 T 2p.11P 2 D 2p.11T 4 T 3p.1111 77-318 / 77-319p.11Contentsp.12DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 2 LASER PRODUCTp.12EN 60825-1p.12Product Overviewp.12Figure A - Laser Toolp.12User Safetyp.12Figure B - Keypad Confi gurationsp.12Figure C - Laser Tool Battery Locationp.12Figure D - Laser Tool Bottomp.12Figure E - Laser Tool on Tripod / Attachmentp.1212 77-318 / 77-319p.12Figure F - Laser Tool on Key Hole Slotp.13LEDs (See fi gure B )p.13Figure G - Laser Tool on Magnetic Mountp.13Figure H - Pendulum / Transport Lock Positionsp.13Figure J - Laser Modesp.13Figure K - Up / Down Beam Aligned to Lower Basep.13Figure L - Manual Modep.13Figure M - Up and Down Beam Accuracyp.13Batteries and Powerp.13Figure N - Level Beam Accuracy (for Single Beam)p.13Battery Installation / Removal (See fi gure C )p.13Figure P - Level Beam Accuracy (for Multiple Beams)p.13Figure R - 90° Square Beam Accuracyp.13
Page 13 of the Stanley SLP3 user manual — 13 77-318 / 77-319
Pagina 13 · klik om te vergroten
Pagina 13

Figure F - Laser Tool on Key Hole Slot

LEDs (See fi gure B )

7. Key Hole Slot for Hanging 16. Screw, nail, or similar object

Power LED - Solid GREEN

  • Power is ON Power LED - Blinking RED

Figure G - Laser Tool on Magnetic Mount

  • Low Battery Power LED - Solid RED

Figure H - Pendulum / Transport Lock Positions

  • Battery Needs Recharging

Figure J - Laser Modes

Lock LED - Solid RED

  • Pendulum lock is ON
  • Self-Levelling is OFF Lock LED - Blinking RED

Figure K - Up / Down Beam Aligned to Lower Base

Figure L - Manual Mode

  • Out of Compensation Range

Figure M - Up and Down Beam Accuracy

Batteries and Power

Figure N - Level Beam Accuracy (for Single Beam)

Battery Installation / Removal (See fi gure C )

Figure P - Level Beam Accuracy (for Multiple Beams)

Figure R - 90° Square Beam Accuracy

  • Laser Tool
  • Turn laser tool to bottom. Open battery compartment cover by pressing and sliding out.
  • Install / Remove batteries. Orient batteries correctly when placing into laser tool.
  • Close and lock battery compartment cover by sliding in until securely closed.

Figure S - Level Beam Accuracy (for Horizontal Line)

Figure T - Horizontal Beam Accuracy

Keypad, Modes, and LED

Keypads (See fi gure B )

Power ON / OFF / Mode Key

Modes (See fi gure J )

  • Dots Only
  • Dots Only
  • Horizontal Line
  • Horizontal Line and Dots
  • All beams OFF

13 77-318 / 77-319

Available Modes (SLP3) · Available Modes (SLP5)

Page 14 of the Stanley SLP3 user manual — 14 77-318 / 77-319
Pagina 14 · klik om te vergroten
Pagina 14

Set Up

  • If positioning over a target, partially tighten the center screw, align laser tool, and then fully tighten.

Mounting on Accessories

Operation

  • Tripod / Accessory Mount (See fi gure E )
  • Position a tripod / accessory in a place where it will not be easily disturbed and near the central location of the area to be measured.
  • Set up the tripod / accessory as required. Adjust positioning to be sure tripod head / accessory mounting base is near horizontal.
  • Remove the leg attachment from the laser tool for easier mounting.
  • Mount the laser tool to the tripod / accessory by pushing up the center screw and tighten.
  • NOTE:
  • See LED Descriptions for indications during operation.
  • Before operating the laser tool always be sure to check the laser tool for accuracy.
  • In Manual Mode, Self-Levelling is OFF. The accuracy of the beam is not guaranteed to be level.
  • Laser tool will indicate when it is out of compensation range. Reference LED Descriptions . Reposition laser tool to be closer to level.
  • When not in use, please be sure to power OFF the laser tool and place the pendulum lock in the locked position.
  • Press

to turn laser tool ON.

  • To turn laser tool OFF, repeatedly press
  • Key Hole Slot (See fi gure F )
  • Place a nail, screw, or similar object into a vertical surface.
  • Rotate the lower base of the laser tool and fl ip the key hole slot up.
  • Carefully hang the laser tool onto the nail, screw, or similar object by the key hole slot on the laser tool.

OFF mode is selected OR press and hold

for ≥ 3 seconds to turn laser tool OFF while in any mode.

  • Press

repeatedly to cycle through the available modes.

  • Magnetic Mount (See fi gure G )
  • Attach the laser tool to any supportive magnetic surface.
  • ALWAYS confi rm that the laser tool is securely attached to the magnetic surface before leaving unattended.
  • Self-Levelling / Manual Mode (See Figures H and L )
  • The pendulum lock on the laser tool needs to be switched to the unlocked position to enable selflevelling.
  • The laser tool can be used with the pendulum lock in the locked position when it is required to position the laser tool at various angles to project non-level straight lines or points.

Applications

  • Plumb / Point Transfer
  • Establish 2 reference points that need to be plumb.
  • Align either the down laser beam or the up laser beam to a

14 77-318 / 77-319

Power · until the · Mode

Page 15 of the Stanley SLP3 user manual — 15 77-318 / 77-319
Pagina 15 · klik om te vergroten
Pagina 15
  • set reference point.
  • The opposing laser beam(s) will be projecting a point which is plumb.
  • Position the desired object until the laser beam is aligned with the second reference point that needs to be plumb with the set reference point.

Up and Down Beam Accuracy (See fi gure M )

  • M 1 Place laser unit as shown with laser ON. Measure distances D 1 and D 2 . Mark points P 1 and P 2 .
  • M 2 Rotate laser unit 180° keeping same distances for D 1 and D 2 . Align downward laser beam with point P 2 . Mark point P 3 .
  • M 3 Measure distance D 3 between points P 3 and P 1 .
  • Calculate the maximum offset distance and compare to D 3 .
  • If D 3 is not less than or equal to the calculated maximum offset distance the tool must be returned to your Stanley Distributor for calibration.

Level / Point Transfer • Use front laser beam to project level reference point out to desired object

  • Establish 2 reference points that need to be level.
  • Align the front beam laser to a set reference point.
  • With a tripod or other stationary object, rotate the laser unit to project the front laser beam to a new location.
  • The laser point at the new location will be level with the fi rst point.
  • Position the desired object until aligned with the laser point. (SLP5 only):
  • Using the horizontal laser beam, establish a horizontal reference plane.
  • Position the desired object(s) until they are aligned with the horizontal reference plane to ensure object(s) are level.

Maximum Offset Distance (SLP3):

= (D1 m x 0,8 mm

m ) + (D2 m x 0,8 mm

= (D1 ft x 0,0096 in

ft ) + (D2 ft x 0,0096 in

Maximum Offset Distance (SLP5):

= (D1 m x 0,4 mm

m ) + (D2 m x 0,8 mm

= (D1 ft x 0,0048 in

ft ) + (D2 ft x 0,0096 in

Manual Mode (See Figures H and L ) • Disables self-levelling function and allows laser unit to project a rigid laser beam in any orientation.

Compare(See fi gure M 3 )

D3 ≤ Maximum

Example (using SLP3):

Accuracy Check and Calibration

  • D 1 = 3 m, D 2 = 1 m, D 3 = 1,5 m
  • (3 m x 0,8 mm m ) + (1 m x 0,8 mm

m ) = 3,4 mm

  • NOTE:
  • The laser tools are sealed and calibrated at the factory to the accuracies specifi ed.
  • It is recommended to perform a calibration check prior to its fi rst use and then periodically during future use.
  • The laser tool should be checked regularly to ensure its accuracies, especially for precise layouts.
  • Transport lock must be in the unlocked position to allow the laser tool to self-level before checking the accuracy.
  • 1,5 mm ≤ 3,4 mm (TRUE, tool is within calibration)

15 77-318 / 77-319

Show 5 more labels / short text on this page
m ) Maximum · ft ) · m ) Maximum · ft ) · (maximum offset distance)
Page 16 of the Stanley SLP3 user manual — 16 77-318 / 77-319
Pagina 16 · klik om te vergroten
Pagina 16

Level Beam Accuracy (Single Beam) - (See fi gure N )

  • If D 2 is not less than or equal to the calculated maximum offset distance the tool must be returned to your Stanley Distributor for calibration.
  • N 1 Place laser tool as shown with laser ON. Mark point P 1 .
  • N 2 Rotate laser tool 180° and mark point P 2 .
  • N 3 Move laser tool close to wall and mark point P 3 .
  • N 4 Rotate laser tool 180° and mark point P 4 .
  • N 5 Measure the vertical distance between P 1 and P 3 to get D 3 and the vertical distance between P 2 and P 4 to get D 4 .
  • Calculate the maximum offset distance and compare to the difference of D 3 and D 4 as shown in the equation.
  • If the sum is not less than or equal to the calculated maximum offset distance the tool must be returned to your Stanley Distributor for calibration.

Maximum Offset Distance:

m x D1 m Maximum

ft x D1 ft

Compare(See fi gure P 4 )

D2 ≤ ± Maximum

Example:

  • D 1 = 10 m, D 2 = 3,0 mm

Maximum Offset Distance:

  • 0,4 mm m x 10 m = 4,0 mm (maximum offset distance)
  • 3,0 mm ≤ 4,0 mm (TRUE, tool is within calibration)

m x (D1 m - (2 x D2 m)) Maximum

ft x (D1 ft - (2 x D2 ft))

90° Square Beam Accuracy (SLP5 only) - (See fi gure R )

Compare(See fi gure N 5 )

D3 - D4 ≤ ± Maximum

  • R 1 Place laser tool as shown with laser ON. Mark points P 1 , P 2 , P 3 , and P 4 .
  • R 2 Rotate laser tool 90° keeping the down laser beam aligned with point P 4 and the front laser beam vertically aligned with point P 2 . Mark point P 5 .
  • R 3 Rotate laser tool 180° keeping the down laser beam aligned with point P 4 and the front laser beam vertically aligned with point P 3 . Mark point P 6 .
  • R 4 Measure the horizontal distance between points P 1 and P 5 to get distance D 2 and points P 1 and P 6 to get distance D 3 .
  • Calculate the maximum offset distance and compare to D 2 and D 3 .
  • If D 2 and D 3 is not less than or equal to the calculated maximum offset distance the tool must be returned to your Stanley Distributor for calibration.

Example:

  • D 1 = 10 m, D 2 = 0,5 m
  • D 3 = 0,4 mm
  • D 4 = - 0,6 mm
  • 0,2 mm m x (10 m - (2 x 0,5 m) = 1,8 mm (maximum
  • (0,4 mm) - (- 0,6 mm) = 1,0 mm
  • 1,0 mm ≤ 1,8 mm (TRUE, tool is within calibration)

Level Beam Accuracy (SLP5 only) - (Multiple Beam) - (See fi gure P )

  • P 1 Place laser tool as shown with laser ON. Mark points P 1 , P 2 , and P 3 .
  • P 2 Rotate laser tool 90° and mark point P 4 .
  • P 3 Rotate laser tool 180° and mark point P 5 .
  • P 4 Measure the vertical distances between the highest and lowest points of the group to get D 2 .
  • Calculate the maximum offset distance and compare to D 2 .

Maximum Offset Distance:

m x D1 m Maximum

ft x D1 ft

Compare(See fi gure R 4 )

D2 and D3 ≤ ± Maximum

16 77-318 / 77-319

Show 7 more labels / short text on this page
= 0,4 mm · = 0,0048 in · = 0,2 mm · = 0,0024 in · offset distance) · = 0,4 mm · = 0,005 in
Page 17 of the Stanley SLP3 user manual — 17 77-318 / 77-319
Pagina 17 · klik om te vergroten
Pagina 17

Example:

Horizontal Beam Accuracy (SLP5 only) - (Horizontal Beam) - (See fi gure T )

  • D 1 = 5 m, D 2 = 2,0 mm, D 3 = 1,5 mm
  • 0,4 mm m x 5 m = 2,0 mm (maximum offset distance)
  • 2,0 mm and 1,5 mm ≤ 2,0 mm (TRUE, tool is within
  • T 1 Place laser tool as shown with laser ON. Roughly aim the laser tool towards the fi rst corner or a set reference point. Measure out half of the distance D 1 and mark point P 1 .
  • T 2 Rotate and roughly aim laser tool towards point P 1 . Mark point P 2 so that it is vertically in line with point P 1 .
  • T 3 Rotate laser tool and roughly aim towards the second corner or set reference point. Mark point P 3 so that it is vertically in line with points P 1 and P 2 .
  • T 4 Measure the vertical distance D 2 between the highest and lowest point.
  • Calculate the maximum offset distance and compare to D 2 .
  • If D 2 is not less than or equal to the calculated maximum offset distance the tool must be returned to your Stanley Distributor for calibration.

Level Beam Accuracy (SLP5 only) - (Horizontal Beam) - (See fi gure S )

  • S 1 Place laser tool as shown with laser ON. Mark point P 1 .
  • S 2 Rotate laser tool 180° and mark point P 2 .
  • S 3 Move laser tool close to wall and mark point P 3 at cross.
  • S 4 Rotate laser tool 180° and mark point P 4 at cross.
  • S 5 Measure the vertical distance between P 1 and P 3 to get D 3 and the vertical distance between P 2 and P 4 to get D 4 .
  • Calculate the maximum offset distance and compare to the difference of D 3 and D 4 as shown in the equation.
  • If the sum is not less than or equal to the calculated maximum offset distance the tool must be returned to your Stanley Distributor for calibration.

Maximum Offset Distance:

m x D1 m Maximum

ft x D1 ft

Maximum Offset Distance:

Compare(See fi gure T 4 )

m x (D1 m - (2 x D2 m)) Maximum

D2 ≤ Maximum

ft x (D1 ft - (2 x D2 ft))

Example:

Compare(See fi gure S 5 )
  • D 1 = 5 m, D 2 = 0,65 mm

D3 - D4 ≤ ± Maximum

  • 0,2 mm m x 5 m = 1,0 mm (maximum offset distance)
  • 0,65 mm ≤ 1,0 mm (TRUE, tool is within calibration)

Example:

  • D 1 = 10 m, D 2 = 0,5 m
  • D 3 = 0,6 mm
  • D 4 = - 0,4 mm
  • 0,2 mm m x (10 m - (2 x 0,5 m) = 1,8 mm (maximum
  • (0,4 mm) - (- 0,6 mm) = 1,0 mm

1,0 mm ≤ 1,8 mm (TRUE, tool is within calibration)

17 77-318 / 77-319

Show 6 more labels / short text on this page
calibration) · = 0,2 mm · = 0,0024 in · = 0,2 mm · = 0,0024 in · offset distance)
Page 18 of the Stanley SLP3 user manual — 18 77-318 / 77-319
Pagina 18 · klik om te vergroten
Pagina 18

Specifi cations

Laser Tool

Stanley SLP3 — Specifi cations diagram (page 18)
Afb. 31 · Specifi cations
Levelling Accuracy (Dot)≤ 4 mm / 10 m ≤ 3 mm / 15 m
Levelling Accuracy (Line)≤ 3 mm / 15 m

Up Beam Accuracy ≤ 4 mm / 10 m ≤ 3 mm / 15 m

Down Beam Accuracy≤ 4 mm / 10 m ≤ 6 mm / 15 m
Square Beam Accuracy≤ 6,8 mm / 15 m
Operating Time≥ 20 hours (Alkaline) ≥ 16 hours (Alkaline)

18 77-318 / 77-319

Page 19 of the Stanley SLP3 user manual — 19 77-318 / 77-319
Pagina 19 · klik om te vergroten
Pagina 19

Notes

19 77-318 / 77-319

Vraag stellen over de Stanley SLP3

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Stanley SLP3

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document