W ARNING If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
B RADFORD W HITE C ORP . Page 2 SECTION 1. General Information 1.1 Introduction ...................................................... 3 1.2 Model Identication .......................................... 4 1.3 W arranty .............................
Brute Deluxe (200, 300, 400) Page 3 SECTION 1. General Information USING THIS MANUAL – Because the Brute Deluxe Boilers and Brute Deluxe W ater Heaters ar e identical appliances, with the exception .
B RADFORD W HITE C ORP . Page 4 IMPORT ANT : The inlet gas pressure to the appliance must not exceed 13 in. w .c. (3.2 kPa). All installations must be made in accordance with: 1) In the U.
Brute Deluxe (200, 300, 400) Page 5 Figure 1A. Dimensional Data - Non Pump Mounted. *Air and vent connections may be on top or back of the Brute Deluxe, and are eld convertible. Size A Combustion Air Connection B* V ent Connection C* Horizontal (Cat III) V ent Pipe Size in.
B RADFORD W HITE C ORP . Page 6 Figure 1b. Dimensional Data - Pump Mounted. *Air and vent connections may be on top or back of the Brute Deluxe, and are eld convertible. Size A Combustion Air Connection B* V ent Connection C* Horizontal (Cat III) V ent Pipe Size in.
Brute Deluxe (200, 300, 400) Page 7 The dimensions and requirements that are shown in T able 2 should be met when choosing the locations for the appliance. 1.6 Locating Pump-Mounted W ater Heater with Respect to Storage T ank(s) For best results, a pump-mounted Brute Deluxe water heater should be located within 15 feet (4.
B RADFORD W HITE C ORP . Page 8 SECTION 2. V enting and Combustion Air W ARNING For indoor installations, as an additional measure of safety , Bradford White strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces.
Brute Deluxe (200, 300, 400) Page 9 2.1.2 Intake Combustion Air The combustion air can be taken through the wall, or through the roof. When taken from the wall, it must be taken from out-of-doors by means of the Bradford White horizontal wall terminal ( see T able 1 ).
B RADFORD W HITE C ORP . Page 10 A VERTISSEMENT Le fonctionnement d’appareils connectés à un évent commun bouché peut provoquer de sérieuses blessures corporelles ou la mort. Des dispositifs de sécurité doivent être mis en place pour empêcher que les appareils soient utilisés avec un évent commun bouché.
Brute Deluxe (200, 300, 400) Page 1 1 U.S. Installations (see note 1) Canadian Installations (see note 2) A= Clearance above grade, veranda, porch, 12 inches (30 cm) 12 inches (30 cm) deck, or balcony B= Clearance to window or door that may Direct V ent Only: 12 inches (30 cm) be opened Other Than Direct V ent: 4 feet (1.
B RADFORD W HITE C ORP . Page 12 6. If the boiler or water heater uses ducted combustion air from an intake terminal located on the same wall, locate the vent terminal at least 3 feet (0.9m) horizontally from the combustion air terminal, and locate the vent terminal at least 1 foot (0.
Brute Deluxe (200, 300, 400) Page 13 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system. (d) MANUF ACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED.
B RADFORD W HITE C ORP . Page 14 remaining connected to the common venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, replace dampers and any other gas burning appliance to their previous conditions of use.
Brute Deluxe (200, 300, 400) Page 15 SECTION 3. Gas Supply and Piping 3.1 Gas Supply and Piping Gas piping should be supported by suitable hangers or oor stands, not by the appliance. The Brute Deluxe’ s gas train allows the user to pipe the gas from either the right side or the left side of the unit.
B RADFORD W HITE C ORP . Page 16 SECTION 4A. W ater Connections — Brute Deluxe Boiler 4A.1 Heating System Piping: Hot Supply Connections — Boiler NOTE: This appliance must be installed in a closed pressure system with a minimum of 12 psig (82.7 kPa) static pressure at the boiler .
Brute Deluxe (200, 300, 400) Page 17 Size 20°F 25°F 30°F 35°F flow gpm H/L feet flow gpm H/L feet flow gpm H/L feet flow gpm H/L feet 200 17 1.6 14 1.
B RADFORD W HITE C ORP . Page 18 Figure 5. Hydronic Piping — Multiple Boilers, Low T emperature System. Figure 6. Hydronic Piping — One Boiler , Multi-T emperature System.
Brute Deluxe (200, 300, 400) Page 19 Figure 7. Hydronic Piping — Primary-Secondary , Reverse-Return. Figure 8. Hydronic Piping — Primary-Secondary , Reverse-Return, Low T emperature.
B RADFORD W HITE C ORP . Page 20 SECTION 4B. W ater Connections — Brute Deluxe W ater Heater 4B.1 W ater System Piping — W ater Heater Hot water piping should be supported by suitable hangers or oor stands. Do not support piping with this appliance.
Brute Deluxe (200, 300, 400) Page 21 installed to temper the water for those uses in order to reduce scald hazard potential. 4B.5 Freeze Protection — W ater Heater Although Brute Deluxe water heater.
B RADFORD W HITE C ORP . Page 22 Figure 9. W ater Heater Piping — One Heater , One T ank. Figure 10. W ater Heater Piping — Multiple Heaters, One T ank.
Brute Deluxe (200, 300, 400) Page 23 Figure 1 1. W ater Heater Piping — One Heater , Multiple T anks. Figure 12. W ater Heater Piping — Multiple Heaters, Multiple T anks.
B RADFORD W HITE C ORP . Page 24 SECTION 5. Electrical Connections W ARNING The appliance must be electrically grounded in accordance with the requirements of the authority having jurisdiction or , in the absence of such requirements, with the latest edition of the National Electrical Code, ANSI/NFP A 70, in the U.
Brute Deluxe (200, 300, 400) Page 25 Figure 14. Field Wiring. 5.2 Field Wiring Field Installed Pump : A pump contactor can be wired to the “2” and “4” terminals on the pump time delay relay , attached to dry contacts of an adjustable delay .
B RADFORD W HITE C ORP . Page 26 Figure 15. Wiring Diagram, ON/OFF Boiler or W ater Heater ..
Brute Deluxe (200, 300, 400) Page 27 Figure 16. Wiring Diagram, 2-ST AGE Boiler or Water Heater ..
B RADFORD W HITE C ORP . Page 28 Figure 18. Logic Diagram, 2-ST AGE Boiler or Water Heater . Figure 17. Logic Diagram, ON/OFF Boiler or W ater Heater .
Brute Deluxe (200, 300, 400) Page 29 SECTION 6. Operating Instructions 6.1 Filling the Boiler System 1. Ensure the system is fully connected. Close all bleeding devices and open make-up water valve. Allow system to ll slowly . 2. If make-up water pump is employed, adjust pressure switch on pumping system to provide a minimum of 12 psi (81.
B RADFORD W HITE C ORP . Page 30 control switches this 24V from the input terminal to the stage terminal. The input for stage 1 is initiated by closing the circuit between the 2 terminals on the terminal strip labeled "input stage 1.
Brute Deluxe (200, 300, 400) Page 31 6.6 Operating the Burner and Set-Up 6.6.1 Set-Up for 0 to 2500 Feet Altitude The setup must be checked before the unit is put in operation. Problems such as failure to start, rough ignition, strong exhaust odors, etc.
B RADFORD W HITE C ORP . Page 32 6.8 T o Restart the Brute Deluxe If drained, follow Section 6.1 in this manual for proper lling and purging. 1. Switch off the main electrical disconnect switch. 2. Close all manual gas valves. 3. W AIT FIVE (5) MINUTES.
Brute Deluxe (200, 300, 400) Page 33 proper functioning. It is strongly recommended that a qualied service technician inspect the basic items listed below every year . a. Ignition control b. Ignitor c. W ater temperature control d. Automatic gas valve e.
B RADFORD W HITE C ORP . Page 34 wires, remove the mounting screws and remove the transformer . Replace transformer in the reverse order . 7.2.8 Flow Switch The Brute Deluxe uses a paddle-type ow switch to ensure that the unit has water ow before ignition is allowed.
Brute Deluxe (200, 300, 400) Page 35 SECTION 8. T rouble Shooting 8.1 Resolving Lockouts There are many causes of lockouts. The three most common causes are: (1) inadequate gas supply , (2) poor combustion, (3) ignitor failure.
B RADFORD W HITE C ORP . Page 36 Item Description Size 200 Size 300 Size 400 COMBUSTION CHAMBER COMPONENTS SeeFigure20 1 Base Assembly 2C1000 3C1000 4C1000 2 Support, T ile Notch 2C2019 3C2019 4.
Brute Deluxe (200, 300, 400) Page 37 JACKET COMPONENTS SeeFigure21 40 Panel, Front, Jacket R2C3320 R3C3320 R4C3320 41 Panel, Rear , Jacket 2C3220 3C3220 4C3220 42 Panel, T op, Jacket 2C3021 3C30.
B RADFORD W HITE C ORP . Page 38 85 Spacer , Gas Orice F2022400 F2022400 F2022400 86 Gas V alve, Combination, Nat. (DSI) 3/4" NPT x 3/4" NPT V0079400 V0079400 V0079400 Gas V alve, Combina.
Brute Deluxe (200, 300, 400) Page 39 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 22 23 24 25 26 27 28 29 30 31 31 31 31 31 32 20 21 19 Figure 20. Combustion Chamber Components.
B RADFORD W HITE C ORP . Page 40 Figure 21. Jacket Components. 40 41 42 48 51 43 44 45 46 47 49 50 52 53 54 54 55.
Brute Deluxe (200, 300, 400) Page 41 60 61 62 63 63 64 64 65 65 66 66 73 67 68 69 70 71 72 Figure 22. Heat Exchanger Components..
B RADFORD W HITE C ORP . Page 42 80 81 85 84 84 86 87 ON/OFF 80 82 83 85 86 86 2S T AGE Figure 23. Gas T rain Components..
Brute Deluxe (200, 300, 400) Page 43 Figure 24. Control Panel Components..
H2343200- ® Ambler , P A 19002 T ech. Service (800) 334-3393 Service Parts (800) 538-2020 www .BradfordWhite.com W arranty Service (800) 531-21 1 1 Litho in U.S.A. © Bradford White 1 101 Document 1244 Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Een belangrijk punt na aankoop van elk apparaat Bradford-White Corp BMT2H (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bradford-White Corp BMT2H heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bradford-White Corp BMT2H vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bradford-White Corp BMT2H leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bradford-White Corp BMT2H krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bradford-White Corp BMT2H bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bradford-White Corp BMT2H kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bradford-White Corp BMT2H . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.