NL
TriStar logo
Officiële handleiding

Tristar AC-5474

112 pagina's·1.1 MB·Airconditioner·PDF·ENJA
Tristar AC-5474
Inhoudsopgave 10 secties AC-5474 AC-5477 AC-5527PR AC-5529 AC-5531 · grounded. o To avoid the possibility of danger, if power cord · ACCESSORIES · EN · … TonenVerbergen
Page 1 of the Tristar AC-5474 user manual — AC-5474 AC-5477 AC-5527PR AC-5529 AC-5531
Pagina 1 · klik om te vergroten
Pagina 1
Tristar AC-5474 — AC-5474 AC-5477 AC-5527PR AC-5529 AC-5531 diagram (page 1)
Afb. 1
Tristar AC-5474 — AC-5474 AC-5477 AC-5527PR AC-5529 AC-5531 diagram (page 1)
Afb. 2

AC-5474 AC-5477 AC-5527PR AC-5529 AC-5531

Tristar AC-5474 — AC-5474 AC-5477 AC-5527PR AC-5529 AC-5531 diagram (page 1)
Afb. 3
Page 2 of the Tristar AC-5474 user manual — grounded. o To avoid the possibility of danger, if power cord
Pagina 2 · klik om te vergroten
Pagina 2
  • SAFETY INSTRUCTIONS
  • Please read this user’s manual carefully to ensure proper use, maintenance and installation.
  • The appliance is for indoor use only.
  • Do not use the unit on a socket under repairs or not installed properly
  • Do not use the unit, follow these precautions: o Near to source of fire. o An area where oil is likely to splash. o An area exposed to direct sunlight. o An area where water is likely to splash. o Near a bath, a laundry, a shower or a swimming
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • The appliance shall be installed in accordance with national wiring regulations.
  • Notes: o If any parts damage, please contact the dealer or a
  • pool.
  • Never insert your fingers, rods into the air outlet. Take special care to warn children of these dangers.
  • Keep the unit upward while transport and storage, for the compressor locates properly.
  • Before cleaning the air-conditioner, always turn off or disconnect the power supply.
  • When moving the air-conditioner, always turn off and disconnect the power supply, and move it slowly.
  • To avoid the possibility of fire disaster, the airconditioner shall not be covered.
  • All the air-conditioner sockets must comply with the local electric safety requirements. If necessary, please check it for the requirements.
  • Children should be supervised to ensure that they do not play with the appliance.

designated repair shop; o In case of any damage, please turn off the air

switch, disconnect the power supply, and contact o The dealer or a designated repair shop; o In any case, the power cord shall be firmly

grounded. o To avoid the possibility of danger, if power cord

is damaged, please turn off the air switch and disconnect the power supply. It must be replaced from the dealer or a designated repair shop.

Page 3 of the Tristar AC-5474 user manual — grounded. o To avoid the possibility of danger, if power cord
Pagina 3 · klik om te vergroten
Pagina 3
  • EN WARNING
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames , an operating gas appliance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that refrigerants may not contain an odor.
  • Appliance shall be installed, operated and stored in a room with a floor area larger than X m2. (X=4 for 5000Btu/h, 7000Btu/h, 8000Btu/h; X=7.7 for 9000Btu/h, 10000Btu/h, 10500Btu/h)
  • Contact authorized service technician for repair or maintenance of this unit.
  • Do not pull , deform. or modify the power supply cord , or immerse it in water . Pulling or misuse of the power supply cord can result in damage to the unit and cause electrical shock.
  • Compliance with national gas regulations shall be observed.
  • Keep ventilation openings clear of obstruction.
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industryaccredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized
  • assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
  • Do not operate or stop the unit by inserting or pulling out the power plug, it may cause electric shock or fire due to heat generation .
  • Unplug the unit if strange sounds, smell, or smoke comes from it.
Tristar AC-5474 — grounded. o To avoid the possibility of danger, if power cord diagram (page 3)
Afb. 4 · grounded. o To avoid the possibility of danger, if…
Page 4 of the Tristar AC-5474 user manual — grounded. o To avoid the possibility of danger, if power cord
Pagina 4 · klik om te vergroten
Pagina 4
  • WARNING Specific information regarding appliances with R 290 refrigerant gas.
  • Thoroughly read all of the warnings.
  • When defrosting and cleaning the appliance , do not use any tools other than those recommended by the manufacturing company.
  • The appliance must be placed in an area without any continuously sources of ignition (for example: open flames , gas or electrical appliances in operation).
  • Do not puncture and do not burn.
  • Appliance shall be installed, operated and stored in a room with a floor area larger than X m2. (X=4 for 5000Btu/h, 7000Btu/h, 8000Btu/h; X=7.7 for 9000Btu/h, 10000Btu/h, 10500Btu/h)
  • This appliance contains Y g (see rating label back of unit ) of R290 refrigerant gas.
  • R290 is a refrigerant gas that complies with the European directives on the environment. Do not puncture any part of the refrigerant circuit.
  • If the appliance is installed, operated or stored in a nonventilated area, the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
  • The appliance must be stored in such a way as to prevent mechanical failure.
  • Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry.
  • Repairs must be performed based on the recommendation from the manufacturing company. Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrigerants.

REFRIGERANT (CE) N 842/2006: This air conditioner contains the refrigerant R290. The amount of refrigerant is less than 1kg, and is in a closed cooling circuit. The coolant does have zero ozone depletion potential, but is a so-called greenhouse gases under the Kyoto Protocol and may thus contribute to global warming, if it is released to the atmosphere. Therefore only trained technicians with refrigerant certificate make a filling or emptying. Your air conditioner does not have be refilled with refrigerant if used properly and has an undamaged coolant circuit. GWP: R290: 3

Page 5 of the Tristar AC-5474 user manual — EN
Pagina 5 · klik om te vergroten
Pagina 5

PARTS DESCRIPTION 1. Air inlet 2. Air outlet 3. Control panel 4. Power cord 5. Castor

ACCESSORIES

EN

PartDescription Hot-air exhaust hose Hose connector (window end) Hose connector (Air conditioner end) Window kit Remote controller
Tristar AC-5474 — EN diagram (page 5)
Afb. 5
Tristar AC-5474 — EN diagram (page 5)
Afb. 6
Page 6 of the Tristar AC-5474 user manual — BEFORE THE FIRST USE
Pagina 6 · klik om te vergroten
Pagina 6

FUNCTION OF CONTROL PANEL

  • Insert the power cord into an grounded AC220~240V/50Hz socket;
  • Press the POWER button to turn on the air-conditioner.
  • Operation temperature range: 18°C - 35°C
  • Check whether the exhaust hose has been mounted properly.
  • When using functions on cooling and dehumidifying, keep an interval of at least 3 minutes between each POWER.
1. Power button 2. Temperature buttons 3. Mode button 4. Fan speed adjustment button 5. Timer on/off button

USE

Tristar AC-5474 — USE diagram (page 6)
Afb. 7
  • Cooling operation
  • Press the “Mode” button till the “Cool” icon appears.
  • Press the p or q button to select a desired room temperature. (16ºC31ºC)
  • Press the “Fan Speed” button to select wind speed.
  • Dehumidifying operation
  • Press the “Mode” button till the “Dehumidify Indicator Lamp” blinks
  • Automatically set the selected temperature to current room temperature minus 2ºC. (16ºC-31ºC)
  • Automatically set the fan motor to LOW wind speed.

BEFORE THE FIRST USE

  • Before starting operations in this section:
  • Find a place where there is power supply nearby.
  • Install the exhaust hose, and adjust the window position well.
  • Fan operation
  • Press the “Mode” button till the “Fan” icon appears.
  • Press the “Fan Speed” button to select wind speed.
Tristar AC-5474 — BEFORE THE FIRST USE diagram (page 6)
Afb. 8
Tristar AC-5474 — BEFORE THE FIRST USE diagram (page 6)
Afb. 9
  • Timer ON setting
  • When the air-conditioner is OFF, press the “Timer” button and select a desired ON time through the temperature and time setting buttons.
  • “Preset ON Time” is displayed on the operation panel.
  • ON time can be regulated at any time in 0-24 hours Timer OFF setting
  • When the air-conditioner ON, press “Timer” button and select a desired OFF time through the temperature and time setting buttons.
  • “Preset OFF Time” is displayed on the operation panel.
  • OFF time can be regulated at any time in 0-24 hours.

Timer operation

Page 7 of the Tristar AC-5474 user manual — FUNCTION OF CONTROL PANEL
Pagina 7 · klik om te vergroten
Pagina 7
  • EN Continuous Drainage
  • When you plan to leave this unit unused for a long time, please remove the rubber blockage from the drainage hole at the bottom of unit, and connect a drain hose to the lower fixing clip. All the water in the water tank will drain outside.
  • If water pump is damaged, continuous drainage can be used, and under this condition, the water pump is not activated. The unit can also work well.
  • If water pump is damaged, intermittent drainage can also be used. Under this condition, when the water full indicator lamp lights up, please connect a drain hose to the lower fixing clip.
Tristar AC-5474 — FUNCTION OF CONTROL PANEL diagram (page 7)
Afb. 10

Internal Tank Water Full Alarm Function The inner water tank in the air-conditioner has one water level safety switches, it controls water level. When water level reaches an anticipated height, the water full indicator lamp lights up. (If water pump is damaged, when the water is full, please remove the rubber blockage at the bottom of unit, and all water will drain outside.)

  • INSTALLATION
  • A removal air-conditioner shall be installed in the flat and empty place all around. Don’t block the air outlet, and the required distance around should be at least 30cm.
  • Socket wiring should be in accordance with the local electric safety requirements.
Tristar AC-5474 — FUNCTION OF CONTROL PANEL diagram (page 7)
Afb. 11

Exhaust Hose Installation · •

Page 8 of the Tristar AC-5474 user manual — TROUBLE SHOOTING
Pagina 8 · klik om te vergroten
Pagina 8
  • Twist both ends of the exhaust hose into the square fixing clip and the flat fixing clip.
  • Insert the square fixing clip into openings at back of the air conditioner.
  • Put the other end of the exhaust hose to the near windowsill.
  • CLEANING MAINTENANCE
  • Before cleaning, be sure to disconnect the unit from any electric supply outlet.
  • First clean the surface with a neutral detergent and wet cloth, and then wipe it with a dry cloth.
  • Do not use gasoline or other chemicals to clean the unit.
  • Do not wash the unit directly.
  • If the conditioner is damaged, please contact the dealer or repair shop.

Window Slider Kit Installation • The installation manner of window slider kit is mostly in “horizontal” and “vertical”, No much difference in actual process.

Tristar AC-5474 — TROUBLE SHOOTING diagram (page 8)
Afb. 12
  • Air Filter
  • If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once every two weeks.
  • Open the air inlet grille and take off air filter.
  • Clean the air filter with neural detergent in lukewarm(40°C)and dry it up in the shade.
  • Putting the air filter into the inlet grille, replace the components as they were.

TROUBLE SHOOTING

TroublesPossible CausesSuggested Remedies The unit does not start when pressing power button• Water full indicator lamp blinks, and water tank is full. • Room temperature is higher than the setting temperature. (Electric heating mode) • Room temperature is lower than the setting temperature. (Cooling mode)• Dump the water out of the water tank. • Reset the temperature • Reset the temperature The unit doesn’t cool enough• The doors or windows are not closed. • There are heat sources inside the room. • Exhaust air hose is not connected or blocked. • Temperature setting is too high. • Air inlet is blocked.• Make sure all the windows and doors are closed. • Remove the heat sources if possible • Connect or clean the exhaust air hose. • Reset the temperature • Clean the air inlet.
Tristar AC-5474 — TROUBLE SHOOTING diagram (page 8)
Afb. 13
Page 9 of the Tristar AC-5474 user manual — SUPPORT You can find all available information and spare parts at http://www..tristar.eu
Pagina 9 · klik om te vergroten
Pagina 9
TroublesPossible CausesSuggested Remedies Auto Power-Off in heating mode• Heating protection, when the temperature at the air outlet exceeds 70℃, the unit will power off automatically.• Restart the unit at enough lower room temperature. Noisy• The ground is not level or not flat enough • The sound comes from the flowing of the refrigerant inside the air conditioner• Place the unit on a flat, level ground if possible • It is normal. E0 Code• Room temperature sensor failed• Replace room temperature sensor (the unit can also work without replacement.) E2 Code• Water tank full• Please empty the water tank
  • GUARANTEE
  • This product is guaranteed for 24 months granted. Your warranty is valid if the product is used in accordance to the instructions and for the purpose for which it was created. In addition, the original purchase (invoice, sales slip or receipt) is to be submitted with the date of purchase, the name of the retailer and the item number of the product.
  • For the detailed warranty conditions, please refer to our service website: <a href="http://www.tristar.eu" rel="nofollow noopener" target="_blank">www.tristar.eu</a>

ENVIRONMENT

This appliance should not be put into the domestic garbage at the end of its durability, but must be offered at a central point for the recycling of electric and electronic domestic appliances. This symbol on the appliance, instruction manual and packaging puts your attention to this important issue. The materials used in this appliance can be recycled. By recycling of used domestic appliances you contribute an important push to the protection of our environment. Ask your local authorities for information regarding the point of recollection.

The product or equipment contains fluorinated greenhouse gas.

Art.nr. AC-5474 CoolantR290 Quantity in kg: 0,10 Global Warming Potential: 3
Art.nr. AC-5477 CoolantR290 Quantity in kg: 0,14 Global Warming Potential: 3

SUPPORT You can find all available information and spare parts at http://www..tristar.eu

Art.nr. AC-5527PR CoolantR290 Quantity in kg: 0,14 Global Warming Potential: 3
Art.nr. AC-5529 CoolantR290 Quantity in kg: 0,16 Global Warming Potential: 3
Art.nr. AC-5531 CoolantR290 Quantity in kg: 0,16 Global Warming Potential: 3
Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
The unit does not start when pressing power button• Water full indicator lamp blinks, and water tank is full. • Room temperature is higher than the setting temperature. (Electric heating mode) • Room temperature is lower than the setting temperature. (Cooling mode) p.8
The unit doesn’t cool enough• The doors or windows are not closed. • There are heat sources inside the room. • Exhaust air hose is not connected or blocked. • Temperature setting is too high. • Air inlet is blocked. p.8

Vraag stellen over de Tristar AC-5474

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Tristar AC-5474

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Tristar AC-5474 handleiding-pdf

112 pagina's·1.1 MB·Airconditioner·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…