Introductionp.3Safety Measures 1p.4Description of the generator set Generator set Identificationp.5Generator Panelsp.5Generator panel for GHS14TIK, GHS24TIK, GLS14TIK and GLS25TIKp.5Description of the generator set Control Panelsp.6Operation General Guidelinesp.7General Guidelines for Usep.7Initial Operation, Running-in Operationp.8Initial Operation - Enginep.8Running-inp.8Operation Startingp.9Check the following points before starting:p.9Operation Running Stoppingp.11Introduction Daily Maintenancep.12Daily Maintenance Maintenance Schedulep.13Every 10 hours, or daily before startingp.13Every 400 hours, or at least 1x a yearp.13After the first 50 hoursp.13Every 100 hours, or at least 1x a yearp.13Check engine Speed/Adjust Fuel Pump Every 400 operating hours Maintenancep.14Maintenance Check engine Speed/Adjust Fuel Pumpp.15Consult a VETUS FARYMANN Specialist! 5p.15Adjusting the GHS4 Fuel Pumpp.15Check engine Speed/Adjust Fuel Pump Every 400 operating hours. Maintenancep.16Generalp.17GHS6.5, GHS8 Only:p.17Winter Lay-up Preparation for Winter Preparation for Summerp.18Preparation for Winterp.18Preparation for Summerp.18Fault Finding, generator Generalp.19Fault Finding Table GHS4 Fault Finding, generatorp.201 No load, no voltagep.202 No load, Voltage too high or too lowp.203 No load, Voltage oscillatesp.20Fault Finding, generator Fault Finding Tablep.21GHS4p.214 Load, no voltagep.216 Load, voltage oscillatesp.215 Load, voltage too high or lowp.217 Load, generator gets too hotp.21Fault Finding, generatorp.23Fault Finding Table GHS6.5, GHS8, GHS14, GHS24, GLS6.5, GLS14 and GLS25p.23Technical Datap.25Type GHS4SI GHS6.5SI GHS8SI GHS14SI GHS14TIp.25Type GHS24SI GHS24TI GLS6.5SI GLS14SI GLS14TI GLS25TIp.26Operating Mediap.30
Page 1 of the Vetus GHS14 user manual
Pagina 1 · klik om te vergroten
Pagina 1

Read and follow the information in this Operating Manual. This will prevent accidents, retain your right to Guarantee claims and keep your generator set properly maintained.

manufacturer. The generator set may only be operated, main- tained and repaired by competent persons who are aware of the possible dangers.

For the Guarantee Conditions, see the Vetus Diesel Service and Guarantee Book.

The relevant instructions for preventing accidents and other gen- erally accepted safety and operating instructions must be taken into account.

This generator set is exclusively intended for applications as stated in the delivery specifications, and should only be used for this purpose. Any other use is in conflict with its intended purpose. The manufacturer cannot accept any liability for dam- age as a consequence of this. Any risks are carried exclusively by the user.

Any modifications made to the generator set by the user relieve the manufacturer of any liability to claims for damage as a con- sequence of this.

Similarly, work on the injection and control system can effect the engine performance and exhaust emissions. Conformance with the legal definitions concerning environmental protection can then no longer be guaranteed.

Use in accordance with its purpose also means following the operating, maintenance and repair instructions as stated by the

Page 2 of the Vetus GHS14 user manual
Pagina 2 · klik om te vergroten
Pagina 2
Page 2 of the Vetus GHS14 user manual
Page 3 of the Vetus GHS14 user manual — Introduction
Pagina 3 · klik om te vergroten
Pagina 3

Introduction

Vetus Generator Sets have been specially developed for use in ships. A wide range of types are available to fulfil every specific requirement.

Your generator set is designed for installation in your ship. This means that some of the components described in this Manual are not necessarily fitted to your generator set.

We have tried to make the differences clear, so that you can easily find the operating and maintenance information related to your generator set.

Please read this Manual before using the generator set, and fol- low the operating and maintenance instructions.

We are always available to answer any questions you may have.

Yours sincerely, Vetus den Ouden N.V.

Dear Customer,

Page 4 of the Vetus GHS14 user manual — Introduction
Pagina 4 · klik om te vergroten
Pagina 4

Introduction

Safety Measures 1

You will find this symbol alongside all information concerning safety. Be sure to follow this informa- tion carefully.

  • Never touch moving parts while the generator set is working.
  • Never touch hot parts of the engine and/or generator set and never put inflammable materials in the vicinity of the engine and/or generator set.

Inform other people who operate the generator set of this safety information.

  • Always stop the generator set before checking or adjusting any part of the engine and/or generator set.

General regulations and laws concerning safety and the preven- tion of accidents should also be taken into account.

  • Always stop the generator set before checking or topping-up the coolant or oil level.
  • NEVER open the expansion chamber cap when the engine is at operating temperature
  • Carry out maintenance work safely by using only the correct tools.
Page 5 of the Vetus GHS14 user manual — Generator panel for GHS4SIK, GHS6.5SIK, GHS8SIK, GHS14SIK, GHS24SIK, GLS6.5SIK and GLS14SIK
Pagina 5 · klik om te vergroten
Pagina 5

Description of the generator set Generator set Identification

Generator Panels

See the ‘Overall Dimensions’ drawing for the identification of the most important generator set connections.

To identify specific engine components, consult the separate engine manual.

Which type of generator set suits which type of engine is described in ‘Technical Data’. This also provides a summary of the manuals for the various engines.

Generator panel for GHS4SIK, GHS6.5SIK, GHS8SIK, GHS14SIK, GHS24SIK, GLS6.5SIK and GLS14SIK

Generator panel for GHS14TIK, GHS24TIK, GLS14TIK and GLS25TIK

Page 6 of the Vetus GHS14 user manual — Description of the generator set Control Panels
Pagina 6 · klik om te vergroten
Pagina 6

Description of the generator set Control Panels

2 5 6 7 8

5 6 7 8

Control Panel for GHS4 Control Panel for GHS6.5, GHS8, GHS14, GHS24, GLS6.5, GLS14 and GLS25

1 Operating hours counter 2 Circuit breaker 3 Contact box 4 Connection box 5 ‘Outside water temperature’ warning lamp 6 ‘Oil pressure’ warning lamp 7 ‘Coolant temperature’ warning lamp.

8 ‘Charge current’ warning lamp 9 ‘Pre-heating’ warning lamp 10 ‘In operation’ warning lamp. 11 ‘ON’ push-button switch 12 ‘Pre-heating’ push-button switch 13 ‘START’ push-button switch 14 ‘STOP’ push-button switch

‑‑9

Page 7 of the Vetus GHS14 user manual — General Guidelines for Use
Pagina 7 · klik om te vergroten
Pagina 7

Operation General Guidelines

General Guidelines for Use

Following the recommendations below will result in a longer operating life, better performance and more economical opera- tion of your generator set.

  • Carry out the maintenance described regularly, including the ‘Daily Procedure before Starting’.
  • Always stop the engine at once if the ‘Charge Current’ warning lamp lights up.
  • Use anti-freeze or coolant fluid in the engine cooling system throughout the year to protect against frost damage and prevent corrosion. See the engine manual for the correct specification.
  • Never allow the engine to run without thermostat.
  • Avoid the generator set having to provide maximum power continuously.
  • Always use a good quality lubricating oil. Consult the relevant engine manual for the correct specification.
  • Use a good quality diesel fuel that is free of water and other pollutants.
Page 8 of the Vetus GHS14 user manual — Initial Operation - Engine
Pagina 8 · klik om te vergroten
Pagina 8

Initial Operation, Running-in Operation

Initial Operation - Engine

Running-in

Before starting the engine for the first time, carry out the follow- ing operations:

In order to achieve a long operating life for your engine, take care with the following for the first 50 operating hours:

  • Fill the engine with oil. Consult the relevant engine Manual for the quantity, specification and location of the filler opening.
  • Allow the engine to reach operating temperature before applying any load.
  • Avoid long-term operation and generator full load.
  • Check the oil level with the dipstick.
  • Fill the cooling system. Consult the relevant engine Manual for the quantity, specification and how to fill the cooling system.
  • Ensure that the fuel tank is filled with diesel fuel. Use only clean, water-free diesel fuel available commercially. The fuel system is self-bleeding.
  • Check the battery and battery cable connections.
  • Start the generator set engine and allow it to run for 10 minutes without load. Check the engine and all connections (fuel, coolant and exhaust) for leaks. Check the voltage supplied by the generator.

Only refuel when the engine is stopped. Do not spill fuel. Prevent unnecessary pollution.

Page 9 of the Vetus GHS14 user manual — Check the following points before starting:
Pagina 9 · klik om te vergroten
Pagina 9

Operation Starting

Check the following points before starting:

  • Engine oil level
  • Coolant level
  • Outboard tap (coolant) open
  • Main switch between battery and generator set is ‘ON’
  • All electrical equipment is switched off.

After repair work Check that all safety equipment is fitted and all tools have been removed from the engine and/or generator. When starting with pre-heater plugs, do not use any extra starting aids (Quick-start sprays, etc.). This could cause an accident.

Starting without Pre-heating - GHS4 - Press the ‘ON’ button briefly; the ‘In Operation’, ‘Oil Pressure’ and ‘Charge’ warning lamps will light up. Press the ‘START’ button and release it as soon as the engine fires.

Starting The generator set is started from the control panel or at the generator set itself.

Page 10 of the Vetus GHS14 user manual — Operation Starting
Pagina 10 · klik om te vergroten
Pagina 10

Operation Starting

If the engine will not start after repeated efforts, a large quantity of water could collect in the exhaust silencer/water lock as a consequence. Excess water in the exhaust silencer can also prevent the engine starting. If necessary, drain water from the silencer.

Starting with Pre-heating - GHS6.5, GHS8, GHS14, GHS24, GLS6.5, GLS14 and GLS25 - Press the ‘ON’ button briefly; the ‘In Operation’, ‘Oil Pressure’ and ‘Charge’ warning lamps will light up and the electric fuel pump will start operating. If the engine is cold, operate the pre-heating. Press the ‘Pre-heat’ button and keep it down for 10 seconds.. Press the ‘START’ button and release it as soon as the engine fires.

The green LED above the ‘ON’ button will remain on, to indicate that the engine is running. Check that the ‘Charge’ warning lamp is off. Cooling water should now flow from the exhaust, if this is not the case, stop the generator set immediately. The ship’s electrical equipment can be switched on after a few minutes.

Page 11 of the Vetus GHS14 user manual — Operation Running Stopping
Pagina 11 · klik om te vergroten
Pagina 11

Operation Running Stopping

None of the 4 warning lamps should light up while the engine is running. Protection devices for oil pressure, coolant temperature and out- side water supply will switch the generator set off automatically if a fault occurs. The ‘Charge’ warning lamp will light up when the dynamo no longer charges, but the engine will continue to run.

Stopping when the Electrical System (12 Volt) breaks down.

GHS4, GHS14, GHS24, GLS6.5, GLS14 and GLS25: When the electrical system (12 Volt) breaks down, the engine will stop immediately.

GHS6.5 and GHS8: When the electrical system (12 Volt) fails, the system will con- tinue to run. The engine can be stopped by pressing the black button on the fuel pump.

Stopping Switch off all the ship’s electrical equipment. Allow the generator set to run for about 1 minute without load. Press the ‘STOP’ key until the ‘In Operation’ light goes off. Then release the ‘STOP’ button. The engine has now stopped.

When the generator set is not going to be used for a longer time, it is recommended that the outboard tap is closed and the main switch is turned to the OFF position.

Page 12 of the Vetus GHS14 user manual — Introduction Daily Maintenance
Pagina 12 · klik om te vergroten
Pagina 12

Introduction Daily Maintenance

Introduction The guidelines below apply to daily and periodic maintenance. Carry out maintenance at the time stated. The time intervals stated are for normal operating conditions. If conditions are poor, carry out maintenance more often. Failure to carry out maintenance can lead to breakdowns and permanent damage to engine or generator. No claim can be made on the Guarantee if maintenance has been neglected.

Page 13 of the Vetus GHS14 user manual — Every 100 hours, or at least 1x a year
Pagina 13 · klik om te vergroten
Pagina 13

Daily Maintenance Maintenance Schedule

Every 10 hours, or daily before starting

Every 400 hours, or at least 1x a year

Check oil level •

Check engine speed (RPM)/Fuel pump adjustment page 47

Check coolant level •

Check valve clearance •

Check cooling water filter •

Replace fuel filter •

After the first 50 hours

Every 800 hours, or 1x every 2 years.

Re-torque the cylinder head bolts •

Clean the heat exchanger •

Drain water from the fuel filter •

Check the outboard water pump •

Change the engine oil •

Change the coolant •

Check the V-belt or drive belt •

Check engine speed (RPM)/Fuel pump adjustment page 47

Check valve clearance •

*) For carrying out this maintenance work, consult the manual for the engine concerned. It is possible that not all maintenance work described will be required on your generator set, this depends on the type of engine.

Every 100 hours, or at least 1x a year

Drain water from the fuel filter •

Change the engine oil •

Check V-belt or drive belt •

Replace oilfilter • · Generator page 50 · Replace oilfilter •

Page 14 of the Vetus GHS14 user manual — Check engine Speed/Adjust Fuel Pump Every 400 operating hours Maintenance
Pagina 14 · klik om te vergroten
Pagina 14

Check engine Speed/Adjust Fuel Pump Every 400 operating hours Maintenance

Checking the Engine Speed The frequency of the mains voltage is not the same all over the world. This frequency can either be 50 or 60 Hz. F or example, the fre- quency in Europe is usually 50 Hz, while in the United States it is 60 Hz. The frequency of the generator set will be the same as the mains frequency in your cruising area.

The speed of the generator will decrease as the load increases. So adjust the generator as follows:

All GHS generator sets: The RPM for a generator without load is about 3100 rpm (51.5‑Hz).

All GLS generator sets: The speed for a generator without load is about 1550 rpm (51.5‑Hz) or about 1850 rpm (61.5 Hz).

N.B.: If you want to connect your on-board network to a dockside connection outside your usual cruising area, take care to check that both voltage and frequency are the same as that for your generator set.

Allow the engine to run until it is warm (coolant temperature about 60 degrees C (140 deg. F ) or higher) before checking the speed and adjusting, if necessary.

Check the speed using a rev. counter, or use a frequency meter connected to the electrical installation. The correct speed can be set using the adjusting screws on the fuel pump.

Page 15 of the Vetus GHS14 user manual — Adjusting the GHS4 Fuel Pump
Pagina 15 · klik om te vergroten
Pagina 15

Maintenance Check engine Speed/Adjust Fuel Pump

Every 400 operating hours.

A

Consult a VETUS FARYMANN Specialist! 5

B

Adjusting the GHS4 Fuel Pump

Adjusting the GHS6.5, GHS8, GHS14 and GLS6.5 Fuel Pump Unscrew both lock nuts and adjust the set screws until the cor- rect speed has been reached. Then tighten up the lock nuts again. Turn set screw A when the speed has to be increased; turn set screw B when the speed has to be reduced.

This can only be adjusted inside the fuel pump itself. When adjustment is required, it is recommended that you let it be done by a Vetus F arymann Service Specialist.

Seal · Increasing the speed · Reducing the speed

Page 16 of the Vetus GHS14 user manual — Check engine Speed/Adjust Fuel Pump Every 400 operating hours. Maintenance
Pagina 16 · klik om te vergroten
Pagina 16
Vetus GHS14 — Check engine Speed/Adjust Fuel Pump Every 400 operating hours. Maintenance diagram (page 16)
Afb. 1 · Check engine Speed/Adjust Fuel Pump Every 400 operat…

Check engine Speed/Adjust Fuel Pump Every 400 operating hours. Maintenance

Unscrew both lock nuts and adjust the set screws until the cor- rect speed has been reached. Then tighten up the lock nuts again. Turn set screw A outwards when the speed has to be increased; turn set screw B outwards when the speed has to be reduced.

Unscrew both lock nuts and adjust the set screws until the cor- rect speed has been reached. Then tighten up the lock nuts again. Turn set screw A outwards when the speed has to be increased; turn set screw B outwards when the speed has to be reduced.

Page 17 of the Vetus GHS14 user manual — General
Pagina 17 · klik om te vergroten
Pagina 17

Maintenance Generator Every 800 operating hours.

General

GHS6.5, GHS8 Only:

Cleaning the generator The generator and AVR (Automatic Voltage Regulator) should be kept as clean as possible. Many electrical faults can be caused by dirt collecting. Remove any dirt and dust from the generator. Blow through the generator using oil-free compressed air. Take care no dust is blown into the windings. The inside and outside of the generator should always be kept free of water, oil and dirt.

Slip Rings and Carbon Brushes Check the slip rings and carbon brushes for wear. Replace worn carbon brushes with new ones of the right type and size. Check to see that the carbon brushes run in the centre of the slip rings.

Check that all electrical connections are correctly and firmly fixed.

The bearing is sealed and lubricated for life, so requires no fur- ther maintenance.

Page 18 of the Vetus GHS14 user manual — Preparation for Winter
Pagina 18 · klik om te vergroten
Pagina 18

Winter Lay-up Preparation for Winter Preparation for Summer

Preparation for Winter

Preparation for Summer

Consult the separate engine Manual for taking it out of service for the winter. It is not necessary to carry out any specific work on the generator at the start of the winter lay-up.

Consult the separate engine Manual for preparation for use again at the start of the summer cruising season.

GHS4, GHS14, GHS24, GLS6.5, GLS14 and GLS25: It is not necessary to carry out any specific work on the generator to prepare it for operation again.

GHS6.5 and GHS8: Check the slip rings for possible corrosion, sand them clean if necessary. F or this, use very fine 400 - 500 Grade) sanding cloth. Further specific work is not required at the start of the cruising season.

Page 19 of the Vetus GHS14 user manual — Fault Finding, generator General
Pagina 19 · klik om te vergroten
Pagina 19

Fault Finding, generator General

When a fault occurs, check the following before carrying out the tests in the Table:

  • The circuit breaker is ‘ON’.
  • The generator has not suffered any mechanical damage.
  • It has not been affected by spilt oil, fuel, dirt or chemicals. If this is the case, clean or repair this before starting testing.
  • The voltage regulator has not been exposed to water. If the regulator is wet, remove it from the connector box and dry thoroughly before refitting.
Page 20 of the Vetus GHS14 user manual — 3 No load, Voltage oscillates
Pagina 20 · klik om te vergroten
Pagina 20

Fault Finding Table GHS4 Fault Finding, generator

1 No load, no voltage

2 No load, Voltage too high or too low

Possible Cause • Loss of residual magnetism.

  • Solution
  • Connect a 12 Volt battery for a short period to the capacitor clamps to regenerate the field.
  • Check the winding resistance. See ‘Technical Data’ for resistance values.
  • Replace capacitor.
  • Check the winding resistance. See ‘Technical Data’ for resistance values.
  • Replace the diode on the rotor.
  • Possible Cause
  • Incorrect engine speed. Solution
  • Check engine speed and reset if necessary.
  • Stator windings short-circuit or poor connections.

3 No load, Voltage oscillates

  • Faulty capacitor.
  • Rotor windings short-circuit or poor connections.

Possible Cause • Engine runs irregularly due to lack of fuel, faulty or wrongly set fuel pump.

Solution • Ensure the supply of enough clean water-free fuel, or: Have the fuel pump checked

  • Interrupted or short-circuit in diode.

by a specialist and repair or re-adjust as required.

Page 21 of the Vetus GHS14 user manual — 7 Load, generator gets too hot
Pagina 21 · klik om te vergroten
Pagina 21

Fault Finding, generator Fault Finding Table

GHS4

4 Load, no voltage

6 Load, voltage oscillates

Possible Cause • Short-circuit in on-board cir- cuit.

Solution • Trace the short-circuit and repair.

Possible Cause • Engine runs irregularly due to lack of fuel, faulty or wrongly set fuel pump.

Solution • Ensure the supply of enough clean water-free fuel, or: Have the fuel pump checked

by a specialist and repair or re-adjust as required. • Repair the connections.

  • Poor electrical connections.

5 Load, voltage too high or low

  • Possible Cause
  • Incorrect engine speed. Solution
  • Check engine speed and adjust as required.

7 Load, generator gets too hot

Possible Cause • Over-loaded.

  • Solution
  • Reduce the load by switching off some of your electrical equipment.
  • Clear the air inlet and outlet.
  • Prevent recirculation of hot air.
  • Blocked air inlet or outlet.
  • Hot air from engine is recirculating as cooling air.
Page 22 of the Vetus GHS14 user manual — 3 No load, Voltage oscillates
Pagina 22 · klik om te vergroten
Pagina 22

Fault Finding, generator Fault Finding Table GHS6.5, GHS8, GHS14, GHS24, GLS6.5, GLS14 and GLS25

1 No load, no voltage

2 No load, Voltage too high or too low

Possible Cause • Loss of residual magnetism.

Solution • Connect a 12 Volt battery for a short period to regenerate the field; plus (+) to ‘X’ and minus (-)

Possible Cause • Incorrect engine speed.

  • Solution
  • Check engine speed and readjust as required.
  • Adjust to the correct voltage.
  • Incorrect voltage setting of voltage regulator.

to ‘XX’ or, plus (+) to ‘F1’ and minus

  • Voltage regulator (AVR) faulty.
  • Replace the voltage regulator (AVR).
  • (-) to ‘F2’.
  • Check the winding resistance. See ‘Technical Data’ for resistance values.
  • Replace the Voltage regulator (AVR).
  • Check the winding resistance. See ‘Technical Data’ for resistance values.
  • Replace the rectifier (GHS8 only).
  • Stator winding short-circuit or poor connections.

3 No load, Voltage oscillates

  • Voltage Regulator (AVR) faulty.
  • Rotor windings short-circuit or poor connections.

Possible Cause • Engine runs irregularly due to lack of fuel, faulty or wrongly set fuel pump.

Solution • Ensure the supply of enough clean water-free fuel. Have the fuel pump checked

  • Faulty rectifier.

by a specialist and repair or re-adjust as required. • Readjust the stability.

  • Incorrect Voltage Regulator (AVR) stability setting.
  • Voltage Regulator (AVR) faulty.
  • Replace Voltage regulator (AVR).
Page 23 of the Vetus GHS14 user manual — 5 Load, voltage too high or low
Pagina 23 · klik om te vergroten
Pagina 23

Fault Finding, generator

Fault Finding Table GHS6.5, GHS8, GHS14, GHS24, GLS6.5, GLS14 and GLS25

4 Load, no voltage

6 Load, voltage oscillates

  • Possible Cause
  • Short-circuit in on-board circuit.
  • Faulty rectifier.
  • Voltage Regulator (AVR) faulty.
  • Solution
  • Trace the short-circuit and repair.
  • Replace rectifier.
  • Replace Voltage regulator (AVR).

Possible Cause • Engine runs irregularly due to lack of fuel, faulty or wrongly set fuel pump.

Solution • Ensure the supply of enough clean water-free fuel. Have the fuel pump checked

  • by a specialist and repair or re-adjust as required.
  • Repair the connections.
  • Readjust the stability.
  • Poor electrical connections.
  • Incorrect Voltage Regulator (AVR) stability setting.
  • Voltage Regulator (AVR) faulty.

5 Load, voltage too high or low

  • Replace Voltage regulator (AVR).

Possible Cause • Incorrect engine speed.

  • Solution
  • Check engine speed and readjust as required.
  • Adjust to the correct voltage.
  • Incorrect voltage setting on voltage regulator.
Page 24 of the Vetus GHS14 user manual — 7 Load, generator gets too hot
Pagina 24 · klik om te vergroten
Pagina 24

Fault Finding Table GHS6.5, GHS8, GHS14, GHS24, GLS6.5, GLS14 and GLS25

Fault Finding, generator

7 Load, generator gets too hot

Possible Cause • Over-loaded.

  • Solution
  • Reduce the load by switching off some of your electrical equipment.
  • Adjust the Voltage Regulator to the correct voltage.
  • Clear the air inlet and outlet.
  • Prevent recirculation of hot air.
  • Voltage too high.
  • Blocked air inlet or outlet.
  • Hot air from engine and or generator is being used again as cooling air.
Page 25 of the Vetus GHS14 user manual — Type GHS4SI GHS6.5SI GHS8SI GHS14SI GHS14TI
Pagina 25 · klik om te vergroten
Pagina 25

Technical Data

Type GHS4SI GHS6.5SI GHS8SI GHS14SI GHS14TI

General Nominal speed 3000 RPM Noise Level — 75 dB(A) 75 dB(A) 78 dB(A) 78 dB(A) Noise Level, with cabinet 68 dB(A) 65 dB(A) 65 dB(A) 70 dB(A) 70 dB(A) @ 3000 RPM Max. Temperature raw water 30°C (86°F) Max. Ambient Temperature 40°C (104°F) Max. Tilt lengthwise 15° Max. Tilt crosswise 25° Weight, without sound cabinet — 120 kg 125 kg 220 kg 200 kg (265 lbs) (276 lbs) (485 lbs) (441 lbs) Weight, with sound cabinet 95 kg 180 kg 185 kg 295 kg 275 kg (209 lbs) (397 lbs) (408 lbs) (650 lbs) (606 lbs)

Engine Specifications Mark Vetus/Farymann Vetus/Mitsubishi Type F1.03 M2.C5 M2.06 M3.09 M3.09

Consult the Manual for the engine concerned for complete engine specifications.

Manual for engine type : F1.03 : STM0061 M2.C5/M2.06/M3.09 : 340102.04 (English) M4.17 : STM0119 (English) VH4.65 : STM4994 (English)

Page 26 of the Vetus GHS14 user manual — Type GHS24SI GHS24TI GLS6.5SI GLS14SI GLS14TI GLS25TI
Pagina 26 · klik om te vergroten
Pagina 26

Technical Data

Type GHS24SI GHS24TI GLS6.5SI GLS14SI GLS14TI GLS25TI

General Nominal speed 3000 RPM 1500 RPM Noise Level 78 dB(A) 78 dB(A) 73 dB(A) 73 dB(A) 73 dB(A) 73 dB(A) Noise Level, with cabinet 70 dB(A) 70 dB(A) 57 dB(A) 57 dB(A) 57 dB(A) 57 dB(A) @ 3000 RPM @ 1500 RPM Max. Temperature, raw water 30°C (86°F) Max. Ambient Temperature 40°C(104°F) Max. Tilt lengthwise 15° Max. Tilt crosswise 25° Weight, without sound cabinet 345 kg 315 kg 170 kg 315 kg 295 kg 415 kg (761 lbs) (694 lbs) (375 lbs) (694 lbs) (650 lbs) (914 lbs) Weight, with sound cabinet 436 kg 395 kg 245 kg 395 kg 375 kg 505 kg (961 lbs) (871 lbs) (540 lbs) (871 lbs) (827 lbs) (1112 lbs)

Engine Specifications Mark Vetus/Mitsubishi Vetus/Hyundai Type M4.17 M4.17 M3.09 M4.17 M4.17 VH4.65

Consult the Manual for the engine concerned for complete engine specifications.

Page 27 of the Vetus GHS14 user manual — Type GHS4SI GHS6.5SI GHS8SI GHS14SI GHS14TI
Pagina 27 · klik om te vergroten
Pagina 27

Technical Data

Type GHS4SI GHS6.5SI GHS8SI GHS14SI GHS14TI

Generator Specifications Mark Syncro Markon Markon Stamford Stamford Type * BWG430 BWG830/ BWG830/ BCI162G BCI162E SL105G SL105G Power, at power factor 0,8 4 kVA 6,5 kVA 8 kVA 14 kVA 14 kVA 3,2 kW 5,2 kW 6,4 kW 11 kW 11 kW Voltage 1 x 230 V 1 x 230 V 1 x 230 V 1 x 230 V 3 x 400 V Current 14 A 22,5 A 27,5 A 46 A 3 x 15,4 A Frequency 50 Hz Number of poles 2 Overload Power Maximum start current for electro-motor 1.5x nominal generator current Power factor Between 0.8 inductive and 1 Operating range Minimum 4% of the nominal speed (RPM) Voltage Control +/- 5% +/- 3,5% +/- 3,5% +/- 2% +/- 2% Insulation Class H Protection Grade IP22 Protection Grade in sound cabinet IP44

N.B.: All the information above is based on generator sets

with a frequency of 50 Hz.

*) BWG430: Brushless, self-exciting alternating current generator with capacitor control.

BWG830: Self-regulating, self-exciting alternating current generator with automatic voltage regulator (AVR).

Page 28 of the Vetus GHS14 user manual — Type GHS24SI GHS24TI GLS6.5SI GLS14SI GLS14TI GLS25TI
Pagina 28 · klik om te vergroten
Pagina 28

Technical Data

Type GHS24SI GHS24TI GLS6.5SI GLS14SI GLS14TI GLS25TI

Generatorspecifications Mark Stamford Stamford Syncro Stamford Stamford Stamford Type * BCI182K BCI162G BWG615E BCI184E BCI164D BCI184F

Power, at power factor 0,8 24 kVA 24 kVA 6,5 kVA 14 kVA 14 kVA 25 kVA 19,2 kW 19,2 kW 5,2 kW 11,2 kW 11,2 kW 20 kW Voltage 1 x 230 V 3 x 400 V 1 x 230 V 1 x 230 V 3 x 400 V 3 x 400 V Current 85 A 3 x 28,5 A 22,5 A 50 A 3 x 16 A 3 x 36 A Frequency 50 Hz Number of poles 2 2 4 Overload Power Maximum start current for electro-motor 1.5x nominal generator current Power factor Between 0.8 inductive and 1 Operating range Minimum 4% of the nominal speed (RPM) Voltage control +/- 2% +/- 2% +/- 2% +/- 2% +/- 2% +/- 2% Insulation Class H Protection Grade IP22 Protection Grade in sound cabinett IP44

N.B.: All the information above is based on generator sets

with a frequency of 50 Hz.

*) BCI162G, BCI162E, BCI182K, BWG615E, BCI184E, BCI164D and BCI184F: Brushless, self-regulating self-exciting alternating current gen- erator with automatic voltage regulator (AVR).

Page 29 of the Vetus GHS14 user manual — Technical Data
Pagina 29 · klik om te vergroten
Pagina 29

Technical Data

Type GHS4SI GHS6.5SI GHS8SI GLS6.5SI GLS14SI (BWG430) (BWG830) (BWG830) (BWG615E) (BCI184E) Winding Resistances Rotor 1,8 Ω 11,9 Ω 11,9 Ω 1,15 Ω 0,64 Ω Stator, Main Winding per section 0,6 Ω 0,28 Ω 0,28 Ω 0,45 Ω 0,20 Ω Stator, Auxiliary Winding 2,8 Ω 1,77 Ω 1,77 Ω 20 Ω 20 Ω Rotor, Auxiliary Winding 0,21 Ω 0,21 Ω

Generator Protection Main circuit Automatic F use (Circuit Breaker) 16 A 20 A 25 A 20 A 50 A

Type GHS14SI GHS14TI GHS24SI GHS24TI GLS14TI GLS25TI (BCI162G) (BCI162E) (BCI182K) (BCI162G) (BCI164D) (BCI184F) Winding Resistances Rotor 1,09 Ω 0,89 Ω 1,4 Ω 1,09 Ω 0,56 Ω 0,74 Ω Main (stator) winding per section 0,10 Ω 0,42 Ω 0,095 Ω 0,21 Ω 0,3 Ω 0,13 Ω Auxiliary Winding, stator 19 Ω 18 Ω 20 Ω 19 Ω 19 Ω 22 Ω Auxiliary Winding, rotor 0,27 Ω 0,26 Ω 0,21 Ω 0,27 Ω 0,26 Ω 0,23 Ω

Generator Protection Main circuit Automatic F use (Circuit Breaker) 50 A 3 x 16 A 80 A 3 x 32 A 3 x 16 A 3 x 36 A

N.B.: All the above information is based on generator sets with a frequency of 50 Hz.

Page 30 of the Vetus GHS14 user manual — Operating Media
Pagina 30 · klik om te vergroten
Pagina 30

Operating Media

Operating Media

  • These are
  • Engine oil
  • Diesel fuel
  • Coolant fluid

Consult the relevant engine Manual for specifications and quanti- ties of the liquids above.

Vraag stellen over de Vetus GHS14

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Vetus GHS14

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Vetus GHS14 handleiding-pdf

312 pagina's·1.9 MB·Generator·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…