NL
Officiële handleiding

VolTect High Voltage Detector (TIC 300 Pro)

3 pagina's·462 KB·Detector·PDF·EN
VolTect High Voltage Detector (TIC 300 Pro)
Inhoudsopgave 12 secties Meet The New Standard · In Non-Contact, High Voltage Detection · The Amprobe TIC 300 PRO with VolTect ™ · TIC 300 PRO with VolTect ™ Quick Start Guide · … TonenVerbergen
Page 1 of the VolTect High Voltage Detector (TIC 300 Pro) user manual — The Amprobe TIC 300 PRO with VolTect ™
Pagina 1 · klik om te vergroten
Pagina 1
VolTect High Voltage Detector (TIC 300 Pro) — Meet The New Standard diagram (page 1)
Afb. 1 · Meet The New Standard
VolTect High Voltage Detector (TIC 300 Pro) — Meet The New Standard diagram (page 1)
Afb. 2 · Meet The New Standard

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431

Visit us at www.TestEquipmentDepot.com

VolTect High Voltage Detector (TIC 300 Pro) — Meet The New Standard diagram (page 1)
Afb. 3 · Meet The New Standard

Meet The New Standard

VolTect High Voltage Detector (TIC 300 Pro) — Meet The New Standard diagram (page 1)
Afb. 4 · Meet The New Standard

In Non-Contact, High Voltage Detection

The Amprobe TIC 300 PRO with VolTect ™

Page 2 of the VolTect High Voltage Detector (TIC 300 Pro) user manual — TIC 410A
Pagina 2 · klik om te vergroten
Pagina 2

TIC 300 PRO with VolTect ™ Quick Start Guide

VolTect High Voltage Detector (TIC 300 Pro) — TIC 300 PRO with VolTect ™ Quick Start Guide diagram (page 2)
Afb. 5 · TIC 300 PRO with VolTect ™ Quick Start Guide
VolTect High Voltage Detector (TIC 300 Pro) — TIC 300 PRO with VolTect ™ Quick Start Guide diagram (page 2)
Afb. 6 · TIC 300 PRO with VolTect ™ Quick Start Guide

On/Off When the TIC 300 PRO is activated, the blue LED and audible alert will pulse at a slow rate, approximately twice per second.

Self-test The TEST button should be used to ensure tool is operational. The TEST function will cause the blue LEDs and audible alert to pulse at a continuous rate on either LOW or HIGH range setting.

LOW Range Setting 1. Push ON/OFF button to turn the unit ON. The unit will default to the high voltage setting when powered-up.

HIGH Range Setting (> 1500 V and

1. Push ON/OFF button to turn the unit ON. The unit will default to the high voltage setting when powered-up.
2. Push the LOW range button, and the unit is ready for low voltage detection.
3. Place the probe tip near, but not touching, the low (
2. Approach the probe tip near, but not touching, the high voltage conductor. See bottom table for range details.
4. If voltage is present, the blue LEDs and audible alert will pulse at an increased rate.
3. If voltage is present, the blue LEDs and audible alert will pulse at an increased rate.

High Range Setting Low Range Setting

VolTect High Voltage Detector (TIC 300 Pro) — High Range Setting Low Range Setting diagram (page 2)
Afb. 7 · High Range Setting Low Range Setting
Voltage (Phase to Ground)Detection Distance (from energized line) AverageVoltage (Phase to ground)Detection Distance Average 30 V1.5”1.5 kV1’ 2” 75 V6.5”2.0 kV2’ 5” 100 V8.5”4.0 kV3” 10.0 kV6’ 3” 120 V10” 25.0 kV9’ 4” 220 V1’1” 50.0 kV13’ 0” 500 V1’7” 75.0 kV14’ 8” 1000 V2’10”100.0 kV19’ 8” 1500 V7’9”122.0 kV22’ 0”

TIC 410A

TIC 300 PRO

For complete information on the TIC 300 PRO, visit amprobe.com

Hot Stick Attachment

Page 3 of the VolTect High Voltage Detector (TIC 300 Pro) user manual — 4159996 B
Pagina 3 · klik om te vergroten
Pagina 3
VolTect High Voltage Detector (TIC 300 Pro) — Meet The New Standard In Non-Contact, High Voltage Detection diagram (page 3)
Afb. 8 · Meet The New Standard In Non-Contact, High Voltage D…
VolTect High Voltage Detector (TIC 300 Pro) — Meet The New Standard In Non-Contact, High Voltage Detection diagram (page 3)
Afb. 9 · Meet The New Standard In Non-Contact, High Voltage D…

Meet The New Standard In Non-Contact, High Voltage Detection

The Amprobe TIC 300 PRO with VolTect™ Non-Contact High Voltage Detector

Key Features

  • Bright visual and loud
  • Low range setting:

30 V ac g 1,500 V ac

  • Self-test verifies that the tool
  • High range setting:

1,500 V ac g 122,000 V ac (must use with TIC 410A Hot Stick Attachment)

  • Push button functionality

for ease of use with PPE gloves

  • Intrinsically safe and

MSHA certified

MSHA

United States Department of Labor

Mine Safety and Health Administration

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

TestEquipmentDepot.com

4159996 B

audible voltage indication · is operational

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de VolTect High Voltage Detector (TIC 300 Pro)

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de VolTect High Voltage Detector (TIC 300 Pro)

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

VolTect High Voltage Detector (TIC 300 Pro) handleiding-pdf

3 pagina's·462 KB·Detector·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…