Gebruiksaanwijzing /service van het product HEPA 2000 van de fabrikant Broan
Ga naar pagina of 38
INST ALLA TION INSTRUCTIONS AND USER MANUAL RESIDENTIAL USE ONL Y INST ALLER: LEA VE THIS MANUAL WITH THE HOMEO WNER. HOMEO WNER: USE AND CARE INFORMA TION ON P A GES 28 and 32 to 36. READ AND SA VE THESE INSTRUCTIONS 04313 re v C MODELS VB0061 HEP A 2000* HF 2.
ABOUT THIS MANUAL First, we want to cong ratulate you on y our purchase of this e xcellent unit which will allow y ou and your f amily to enjo y clean and health y air throughout y our home for years to come! Because of the large amount of models cov ered by this pub lication, the illustrations are typical ones.
! - 3 - T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSON(S) OBSER VE THE FOLLO WING: 1. This unit is intented f or residential installation only . 2. Use this unit only in the manner intended by the man ufacturer . If you ha ve questions, contact the manuf acturer at the address or telephone number listed in the warranty .
1.0 B EFORE ST ARTING . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 1.1 Inspect the Content of the Boxes . . . . . . . . . . .. . 6 2.0 T YPICAL I NST ALLA TIONS . . . . . . . . . . . . . . . . . . . . . . . .6 2.1 HEPA 1000 and HF 1.0 Unit Installations .
4.6 Installation des conduit flexibles isolés . . . . . . . . .23 4.6.1 Raccordement à la transition Tandem® . . . . . .23 4.6.2 Raccordement aux bouches ovales de 5”à 6” . .24 4.7 Installation de la bouche extérieure double . . . . . .25 4.7.
1. BEFORE ST ARTING 1 .1 I NSPECT THE C ONTENTS OF THE BO XES • Inspect the exterior of the unit f or shipping damage. Ensure that there is no damage to the door , door latches, main s witch, etc. • Inspect the interior of the unit for damage . Ensure that blo wer assembly , heat recov er y core (HEP A 3000 et HF 3.
- 7 - 2. TYPICAL INST ALLA TIONS (CONT’D) 2.1.1 S T AND A LONE (Primar ily f or homes with radiant hot w a t e r o r electric baseboard heating.) Stale air is dra wn to the unit by the register located at the highest le vel of the house. Filtered air is supplied by the register located at the lo west le vel.
2.1.2 C ENTRAL D RA W P OINT (C ONNECTION T O FORCED AIR SYSTEM ) VH0038 Stale air is dra wn to the unit by the register located at the highest le vel of the house.
- 9 - 2.1.3 R ETURN -R ETURN I NST ALLA TION (C ONNECTION T O A FORCED AIR SYSTEM ) 2. TYPICAL INST ALLA TIONS (CONT’D) Filtered air and stale air flow through the f orced air system ducts which simplifies the installation. Filtered air is supplied to the retur n (plen um) of the f orced air unit .
2. TYPICAL INST ALLA TIONS (CONT’D) The HEP A 4000 unit was created to meet specific requirements related to geographic locations . T ake a look on the map below . The shaded area shows where the HEP A 4000 can be installed. NO TE: The HEP A 4000 unit is designed to assist in the management of humidity introduced into the home.
All 3 types of installation can be used in the attic (Stand Alone, Central Dr aw P oint or Return-Retur n). The example sho wn below is a Return-Retur n installation (connection to a f orced air system). VH0051 - 11 - A por tion of stale air is e xhausted to the outside and the rest is drawn to the unit.
- 12 - 2.3 HEP A 2000, HF 2.0, HEP A 3000, HF 3.0 AND HEP A 4000 U NIT I NST ALLA TIONS 2.3.1 S T AND A LONE (Primar ily f or homes with radiant hot w a t e r o r electric baseboard heating.
- 13 - 2.3.2 C ENTRAL D RA W P OINT (C ONNECTION T O A FORCED AIR SYSTEM ) 2.3 HEP A 2000, HF 2.0, HEP A 3000, HF 3.0 AND HEP A 4000 U NIT I NST ALLA TIONS ( CONT ’ D ) A por tion of stale air (coming from the register located in the highest le vel of the house) is e xhausted to the outside and the rest is drawn to the unit.
2. TYPICAL INST ALLA TIONS (CONT’D) A por tion of stale air is e xhausted to the outside and the rest is drawn to the unit. Outside fresh air is blended with interior air and then filtered. This filtered air is supplied to the retur n (plen um) of the f orced air unit .
3.2 HEP A 2000, HF 2.0, HEP A 3000, HF 3.0 AND HEP A 4000 U NITS FRONT VIEW T OP VIEW - 15 - 3.1 HEP A 1000 AND HF 1.0 U NITS FRONT VIEW T OP VIEW 17.8'' (452 mm) 29'' (737 mm) 22.9'' (581 mm) VK0047 29.4'' (748 mm) VK0048 17.
3. DIMENSIONS (CONT’D) 3.3 M OUNTING AND S ER VICING C ONSIDERA TIONS • The two f ollowing pictures are sho wing the minimum clearance needed to open the door completely .
4.2 M OUNT THE P ORTS ON THE U NIT Mount the 8” oval ports and the 5” to 6” ov al por ts on the top of the unit using the screws provided in the hardw are box (4 scre ws #8 x 3/4” long per por t). NO TES: 1. The HEP A 1000 and the HF 1.0 units don’t hav e the 5” to 6” o val por ts.
- 18 - 4.3 H OW TO H ANG THE U NIT Use the 4 chains and springs in the hardware pack pro vided with the unit. According to your needs , you can install the unit either in v er tical or horizontal position.
4.3 H OW TO H ANG THE U NIT ( CONT ’ D ) • T ur n the s witch knob to OFF position in order to unlock the door . Unlatch the door and open it. Using a screwdriver , remo ve the 2 retaining scre ws of the front plate and carefully remov e the front plate from the unit.
4.5 I NST ALLING 8’ ’ D UCTS AND R EGISTERS 4.5.1 S T AND A LONE S YSTEM ( AS ILLUSTRA TED IN S ECTIONS 2.1.1 AND 2.3.1) Stale air exhaust ductw ork • Install the stale air exhaust register in the main area where the contaminants are produced: kitchen, living room, etc.
4.5 I NST ALLING 8’ ’ D UCTS AND R EGISTERS ( CONT ’ D ) How to connect the 8’ ’ flexible duct to the registers and unit ports (cont’ d) • Using the colored sticker dot included, identify which duct it is (red dot f or stale airflow and b lue dot for filtered airflo w).
4.5 I NST ALLING 8’ ’ D UCTS AND R EGISTERS ( CONT ’ D ) 4.5.2 C ENTRAL D RAW P OINT ( AS ILLUSTRA TED IN S ECTIONS 2.1.2 AND 2.3.2) ( CONT ’ D ) Filtered air ductwork (Return side connection) (cont’ d) • Fix the duct connector to the forced air unit duct using its 4 retaining screws (#8 x 3/4” long).
4.6 I NST ALLING I NSULA TED F LEXIBLE D UCTS (HEP A 2000, HF2.0, HEP A 3000, HF 3.0 AND HEP A 4000 UNITS ONL Y ) Use the f ollowing procedure f or connecting the insulated flexib le ducts to the T andem® transition* ( EXHA UST AIR T O OUTSIDE and FRESH AIR FROM OUTSIDE ).
- 24 - 4.6 I NST ALLING I NSULA TED F LEXIBLE D UCTS (HEP A 2000, HF 2.0, HEP A 3000, HF 3.0 AND HEP A 4000 UNITS ONL Y ) ( CONT ’ D ) 4.6.2 C ONNECTION TO THE 5’ ’ TO 6’ ’ O V AL PORTS OF T.
4.7 I NST ALLING D UA L E XTERIOR H OOD * (HEP A 2000, HF 2.0, HEP A 3000, HF 3.0 AND HEP A 4000 UNITS ONL Y ) 4.7.1 A SSEMBLING D UA L E XTERIOR H OOD Exterior dual hood is coming in separate par ts. Using 2 #8 x 3/4” screws , assemble the top metal screen and the pl ast ic g r ille to the dual e xterior hood.
4.7 I NST ALLING D UA L E XTERIOR H OOD (HEP A 2000, HF 2.0, HEP A 3000, HF 3.0 AND HEP A 4000 UNITS ONL Y ) ( CONT ’ D ) 4.7.3 C ONNECTING T ANDEM ® TRANSITION TO EXTERIOR D UA L H OOD ( CONT ’ D ) 2. Joint the end of the T andem® transition to the rear of the e xterior backplate.
4.8 C ONNECTING THE D RAIN (HEP A 3000 AND HF 3.0 UNITS ONL Y ) VO0025 1 VO0046 1 2 3 1 .Remov e the door by turning the s witch knob to the OFF position (to unlock the door).Then, unlatch the door and open it. Slide out the core assembly to access the 2 dr ain fitting hole locations ( 1 ).
5.1 M AIN S WITCH All units are equipped with a 3-position main s witch, located on the front panel. 5.2 O PTIONAL W ALL C ONTROLS There are 2 optional wall controls a vailab le: C12 / CM control (intented f or HEP A 1000 / HF 1.0 and HEP A 2000 / HF 2.
5.4 I NST ALLA TION OF THE O PTIONAL W ALL C ONTROLS (C ONTROLS C12 / CM AND C34 / CMR) 1. Determine the more convenient location f or the control. 2. Remov e the cov er plate control ( 1 ).
5.4 I NST ALLA TION OF THE O PTIONAL W ALL C ONTR OLS (C ONTROLS C12 / CM AND C34 / CMR) ( CONT ’ D ) 5. P ass the other end of the cable through the w all. Reinstall the cover plate . Using wall anchors (not included) and pro vided screws, mount the w all control on the wall.
5.4 I NST ALLA TION OF THE O PTIONAL W ALL C ONTR OLS (C ONTROLS C12 / CM AND C34 / CMR) ( CONT ’ D ) 8. Using a small rod, pierce a hole through the unit at the end of the wire channel. (See picture beside.) Splice bac k the end of the cable to access the 4 wires .
5.5 O PERA TING C12 / CM C ONTROL 5.5.1 C12 / CM C ONTROL DESCRIPTION 5.5.2 U SING C12 / CM C ONTROL • OFF: T o stop the unit, slide the button on this position. • N ORMAL : For a da y-to-da y usage, slide the button on this position. The unit then will operate on normal speed.
5.6 O PERA TING C34 / CMR C ONTROL 5.6.1 C34 / CMR C ONTROL DESCRIPTION 5.6.2 U SING C34 / CMR C ONTROL • OFF: T o stop the unit, slide the button on this position. • N ORMAL : For a da y-to-da y usage, slide the button on this position. The unit then will operate on normal speed.
6.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) If your unit is equipped with an optionnal w all control (C12 / CM or C34 / CMR) you should perf orm this maintenance when the Filter Maintenance light is flashing . Otherwise, this maintenance must be perf ormed ev ery 6 months to ensure your unit proper operation f or years to come .
6. MAINTENANCE (CONT’D) 6.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) ( CONT ’ D ) 4. Using your thumbs , push on the prefilter* side to disengage it from the filter car tridge. Then, slide it out of the filter car tridge and discard it. Install the new prefilter* b y re versing this operation.
6. MAINTENANCE (CONT’D) 6.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) ( CONT ’ D ) 6. Close the door , close the latches and turn ON the switch knob to its pre vious position.
- 37 - *The HEP A filter is factory installed in all our units. Howe v er , when it will be time to be replaced, a pleated filter or a f oam filter can be purchased, but the filtration efficiency will not be the same as a HEP A filter . **Items 6 and 7 are optionals.
- 38 - If the problem is still not solv ed, call your installer or the nearest appro ved Service Center . Also , you can reach the Customer Service Depar tment at the follo wing telephone numbers: Exclusively f or models HEP A 1000, HEP A 2000, HEP A 3000 and HEP A 4000: 1 800 567-3855.
Een belangrijk punt na aankoop van elk apparaat Broan HEPA 2000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Broan HEPA 2000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Broan HEPA 2000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Broan HEPA 2000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Broan HEPA 2000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Broan HEPA 2000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Broan HEPA 2000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Broan HEPA 2000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.