This document may be reproduced or transmitted neither in excerpts nor completely in any form with any media (neither electronically nor mechanically, including photocopying and recording) and by no data storage or recall system with the exception of an approval on the part of ADIC/ GRAU Storage Systems.
ADIC/GRAU Storage Systems reserves the right to correct, to update or to modify the information contained in this document.
DAS is a registered trade mark of ADIC/GRAU Storage Systems GmbH
DAS is a trade mark of ADIC/GRAU Storage Systems GmbH
Other trade marks are the property of the relevant owner.


2.6 Technical Data 2-8 2.6.1 Electrical system 2-9 2.6.2 Noise 2-9 2.6.3 Climatic conditions 2-9
3.1 Use as intended 3-2
3.2 Warning indications 3-3
3.3 Scope 3-5
3.4 Protective devices 3-5 3.4.1 System access 3-5 3.4.2 Mechanical lock 3-5 3.4.3 Main switch 3-5
4.1 Switches on the control cabinet 4-1
4.2 Starting the AML/J system 4-3
4.3 Stopping the AML/J system 4-4 4.3.1 Normal stopping 4-4 4.3.2 Emergency shutdown 4-5
4.4 Restarting the AML/J system 4-6
4.5 Manual operating mode 4-7
4.6 Switching over to Dual-AMU 4-8
5.1 Application 5-1 5.1.1 Layout of the menu bar 5-2 5.1.2 Selecting a command 5-2 5.1.3 Change size of the windows 5-3 5.1.4 Move windows 5-3 5.1.5 Close window 5-3
5.2 Menu overview 5-4
5.3 Shutdown menu 5-5
ii Contents

5.4 Edit menu 5-7
5.5 View menu 5-8 5.5.1 Archive 5-8
5.6 Operations menu 5-19 5.6.1 Operator login 5-19 5.6.2 Manual Operation 5-20 5.6.3 Disaster Recovery 5-22
5.7 Admin menu 5-23 5.7.1 Administrator Login 5-23
5.8 Window menu 5-24
5.9 Help menu 5-25
6.1 Overview 6-1
6.2 I/O unit/C 6-3 6.2.1 Inserting cartridges 6-4 6.2.2 Ejecting cartridges 6-5
6.3 I/O unit/D (HICAP) 6-6 6.3.1 Inserting cartridges 6-7 6.3.2 Ejecting cartridges 6-8
6.4 I/O unit/E 6-9 6.4.1 Inserting cartridges 6-9 6.4.2 Ejecting cartridges 6-10
6.5 Disaster Recovery 6-11
iii March 31, 1999

iv Contents

1.1 Contents
This Guide contains information and instructions for the safe operation of the AML/J system.
This Guide is written for users who work with the AML/J.
The Guide is broken down into the following chapters:
Chapter 1 Introduction - Notes on the use of the Guide
Chapter 2 Overview - Contains general information on the AML/J components.
Chapter 3 Safety - Describes the danger symbols, mes- sages, safety functions and considerations for the safe operation of the AML/J.
Chapter 4 Operation - Describes the functions for switch- ing the AML/J on and off.
Chapter 5 Menus and commands - Describes the menus and the commands executed by the AML/J.
Chapter 6 Processing media - Describes the I/O unit and its use.
Index

DOC D00 024 AML/J Maintenance Guide
DOC D00 014 AML/J Software Backup
DOC D00 007 AML/J Installation Guide
DOC E00 003 AMU Installation Guide
DOC E00 007 AMU Problem Determination Guide
DOC E00 014 AML Controller User Guide
DOC E00 005 AMU Reference Guide
The following symbols and notes draw your attention to important infor- mation.
For detailed explanation of the symbols see Warning indications on page 3-3.
+ Press keys simultaneously
italics Heading, e.g. Chapter 3, Safety File name, e.g. dasdata.ini Variable, e.g. client_name
&KLFDJR Term appearing on the workspace of the AMU
bold Special term, e.g. Scratch-Pool
courier Lines or terms in an input window - Program message - Command - Parameter or file
Param1 | Param2 Alternative parameters
[courier] Optional parameters · Reference · 1-2 Introduction

!
The use of the AML/J by untrained personnel can lead to dangerous situations. The consequence can be severe to lethal injuries due to moving or current-conducting parts. For this reason an introductory course at ADIC/GRAU is recommended for all persons who handle the AML/J.
The operator is responsible that the following functions are performed on the system only by qualified personnel:
You may perform certain work and adaptations yourself only if you are qualified for this by corresponding education and training.
It is extremely important that the user is familiar with all safety rules before working with the system and follows them.
If you cannot solve a problem with the aid of this document or if you are inter- ested in a recommendation regarding training, please contact your contract part- ner or the ADIC/GRAU Technical Assistance Center (ATAC).
ADIC/GRAU Storage Systems GmbH ADIC Eschenstrasse 3 10949 East Peakview avenue 89558 Boehmenkirch Englewood, CO 80112 Germany U.S.A.
We would be pleased to help you further.
Telephone: 1 800 827 3822 North America +49 6142 992364 Germany 00800 9999 3822 (the rest of the world)

We are legally obliged to observe our products even after delivery. Therefore please notify us about everything which is of interest to us:
ADIC-GRAU Storage Systems GmbH ADIC Eschenstrasse 3 10949 East Peakview 89558 Boehmenkirch avenue Germany Englewood, CO 80112 U.S.A.
1-4 Introduction

Telephone: 1 800 827 3822 North America +49 6142 992364 Germany 00800 9999 3822 (the rest of the world)

1-6 Introduction

2.1 Overview of the system components
Storage media such as magnetic tape cartridges, optical disks and CD- ROMs are brought automatically into the associated drives and fetched from there again with the AML/J. The storage media are brought to the drives with the aid of software in the host and in the AML/J control unit and discharged from these drives again.
The AML/J is a modular system and consists of
− Handling unit − Storage racks − Control cabinet − I/O unit (E/I/F) • up to 9 extension modules (optional)
− Storage racks − I/O unit (E/I/F)

AML/J is connected through the AMU (AML Management Unit) to one or several hosts. The possibilities of the connection are described in the AMU Reference Guide.

The AML/J system can be installed on the unfinished floor or on a false floor.
The handling unit moves the cartridges between the storage cells, drives and the I/O unit. The handling unit has a gripper. A barcode scanner on the gripper identifies the cartridges at the compartments in the archive. Further details are described under Handling unit on page 2-6. The car- tridges can be brought into the AML/J system or moved out from the system with the aid of the I/O unit without interrupting the work. Additional details are described under I/O unit on page 2-7.
Manual access to the compartments in the archive, the handling unit and the drives is through an access door after switching off the power supply.
The cartridges in the AML/J are moved by host requests. Primary requests are for mounting and discharging cartridges in the drives and for inserting/ejecting cartridges into/out from the AML/J.
Each cartridge can have an external machine and user readable label to identify the cartridge in the AML/J at stocktaking and when adding a cartridge to the AML/J. The AMU stores the physical storage location of the cartridge in a database which is based on the Volser (Volume Serial Number).
Apart from the commands for moving the tape cartridges, the host can also request status, configuration and cartridge storage information from the AML/J control unit.
The AML/J system consists of the following functional units:
2-2 Overview

The AML/J system supports a large number of drives for different stor- age media.
The control unit of the system is housed in a control cabinet. This control cabinet contains:
− Power supply − Motor control − Interface converter − Safety system • Drive(s) (optional)

The AMU is the control processor for the AML system. In the normal mode the host computer sends the commands to the AMU for controlling the system. The AMU is located next to further power supply compo- nents in the control cabinet Figure 2-2: on page 2-3.
It is possible to connect a second AMU PC in parallel to back up against failures due to failures of the PC hardware. This redundant version is called Dual-AMU, and a few cables have to be reconnected for the change.
Control unit · AMU monitor · Keyboard

The AMU hardware consists of:
The AMU software components are:
− interprets the commands coming from the host computer − checks these commands for executability • Archive catalogue administration
− for start-up − for service − for the operator • Configuration (describes the individual structure of the archive)
The AMU does not register the data contents of the cartridges.
Information · 2-4 Overview

The AML/J system contains compartments (storage cells) in linear racks (stationary storage segments ( Figure 2-3:). Table 2-1: Coordinates of the storage cells on page 2-5 contains the coordinates of the storage cells.

L3 - LD 01 - 99 01 01 - 99 01 - 99
Type Module Segment Row Compart-
The module number corresponds to the number of the segment whereby the assignment of the module numbers to the segment can be determined by the user at start-up and the segment is always 01. The rows are counted from below to above and the compartments from the left to the right. Optical disks occupy two compartments in the database.
ment

The handling unit identifies and moves cartridges between the storage cells, drives and the I/O unit.

Access to the archive compartments and the drives is facilitated with the handling unit. The handling unit executes the commands of the AML Management Software (AMS) and returns status messages as response.
The handling unit is equipped with a (laser) barcode scanner. Typical tasks of the handling unit are inserting and ejecting cartridges, placing and gripping cartridges in the archive, mounting the connected drives with the cartridges and reading a barcode label attached to the car- tridges.
− with rollers on 2 guide rods below − by one guide rod with loose bearing (play compensation) above
2-6 Overview

The I/O unit facilitates inserting and ejecting cartridges without inter- rupting normal processing ( Figure 2-5:).

Each cartridge in the AML/J system can have an external user and machine readable label for identifying the Volsers (Volume Serial Number). The external label contains between one and 16 characters for the Volser. The Volser is composed of the uppercase letters A-Z and the numbers 0-9. The AML/J system supports different types of label (e.g. “Code 39” and “STK”).

Width x depth Height
Basic module 1.00 m x 1.50 m (3.28 ft x 4.92 ft)
2.05 m (6.73 ft)
0.75 m x 0.82 m (2.46 ft x 2.69 ft)
Weight in lbs Weight in kg
Basic module 721 509 326 230 kg
Control cabinet - 331 - 150 kg
Extension module 688 454 311 205 kg
390 kg/m2 Extension module

Total system connection 230 V ± 10% 1, N, PE
16 A fuse slow-blow
10 A fuse slow-blow
Power section voltage 48 V =
Frequency 50 Hz 60 Hz
Control voltage 24 V =
Degree of protection IP 50
Maximum 1.2 kW
Total system 80 dB (A)
Temperature 10 .. 32 °C
Humidity 15 .. 80%
Europe North America · Fuses (by customer)

2-10 Overview

Apart from the safety provisions in this chapter, the local and specific technical safety regulations apply.
Avoid hazards during maintenance and in operation of the system by
Knowledge of and observance of these instructions are indispensable for the safe handling of the ADIC/GRAU Storage Systems AML/J sys- tems.
Information

The quotation and the order confirmation as well as the scope defined in this document are part of the AML/J documentation. Any use other than that specified in this is considered to be not as intended.
This system is intended for processing:
Any use extending beyond this is not as intended.
ADIC/GRAU Storage Systems is not liable for damages which arise because of use not agreed with it - the user bears the risk alone.
The following are also included in use as intended
3-2 Safety

ADIC/GRAU classifies hazards into different categories. Table 3-1: shows the relation between symbols, signal words, actual hazards and possible conse- quences.
to... Signal word Definition Consequences
Death or very severe injuries (maiming)
Possibly death or very severe injuries
Possibly light or slight injuries
Directly approaching electrical danger situation
Death or severe injury
Possibly light or medium injury
Situation possibly caus- ing damage
Possibly damage of the product and its environment
Potential risk of damage to the electronics
Possibly damage to the product
Information Application tips and other important/use- ful information and hints
No dangerous or damaging conse- quences for persons or things

Especially emphasized paragraphs in this Guide warn against a hazard or draw your attention to important information. These include the following paragraphs and symbols:
In connection with the signal words of ‘Danger’ or ‘Warning’, this symbol warns against a dangerous situation in which personal death or severe injuries are threatening. In connection with the signal word of ‘Caution’, the symbol warns against a dangerous situation in which light injuries can be the conse- quence.
There is risk of a lethal electric shock. Electrical current is possibly present at places identified with this symbol. Before all work always ensure that no electrical connections are under voltage.
This symbol is a laser warning. Use only the described procedures for adjusting and setting up the laser. Injuries can be caused by laser light if other procedures are used.
This symbol refers to specific regulations, rules, instructions and working procedures which must be observed. Nonobservation of this symbol can result in equipment damage or destruction or other mate- rial damage.
This symbol refers to the risk of equipment damage because of electro- static discharges.
This symbol indicates a hint or important information for the user. No risks of personal or material damage are connected with this symbol.
3-4 Safety

These instructions apply for the ADIC/GRAU Storage Systems AML/J systems.
Further safety regulations for the components used in the system are not put out of force by these instructions.
The documentation of the external manufacturers are integral part of the AML/J documentation.
The AML/J system is equipped with the following protective devices:
The AML/J system is surrounded completely by panelling. Access to the system is possible only through a monitored door (or doors).
The panelling of the AML/J system separates the danger area from the normal working area. The danger area of the system is the area in which there is a risk of injury due to a movement of the components.
Movements of the mechanical components in the AML/J system can cause severe injuries. The access to the system may be opened only by authorized personnel.
The access door(s) to the system can be opened from the outside only with a key. Authorized personnel are responsible for the safety of the key.
If you switch off the main switch, you stop the movement electronics and separate the system from the power supply. All movements of the robot are stopped immediately. Switch the main switch off immediately in the case of risk of injury or possible material damage.
Information

Apart from emergency situations, the AML/J system is firstly always stopped with the normal shutdown routine before the main switch is switched off. ADIC/GRAU Storage Systems is not liable for damages because of actuation of the main switch in a manner not intended. The user bears responsibility solely for this.
Movements of the mechanical components in the AML/J system can cause severe injuries. Before switching on the main switch and restart- ing the AML/J system convince yourself that no risks for persons and material are caused by this.!
3-6 Safety

In the normal case the host sends the commands to the AML/J. The AMU is used by the operator for control purposes. The operator is responsible for the following tasks:
You will find information on handling the cartridges under Inserting car- tridges on page 6-4 and Ejecting cartridges on page 6-5. In the case of equipment disturbances the operator can process the cartridges.
You will find several switches for switching the components on and off in the control cabinet. In addition to the switches on the front of the con- trol unit, a mains switch is located on the back of the control unit.
Figure 4-1: Control unit on page 4-1 shows a view of the front side of the control unit.
Main switch (S3) "Control on" button (only for HICAP)
The switches on the control unit are described in Table 4-1: .

1 Main switch S3 Switching on the main supply voltage.
The following are not in the circuit of the main switch:
2 Only in sys- tems with HICAP illuminated pushbutton (green)
The control lamp lights up after actuation. Activates the control Prerequisites
Main switch switched on, all doors are closed
ON
3 Mains switch (back of the control unit)
Switching on the line voltage including that for AMU computer and monitor.
Switch Description · 4-2 Operation

Perform the following steps to start the AML/J system.
Step 1 Ensure that:
The robot requires sufficient free space for the homing run.
All axes of the robot move during the homing run. Objects and system parts within the range of the robot can be damaged.
The movements of the mechanical components in the AML/J system can cause severe injuries. Ensure before switching the main switch on (position 1) that there are no dangers for persons or equipment.
Step 2 Switch the mains switch on the AMU PC on The AMU PC is located in the control cabinet, above the control unit (Figure 2-2: on page 2-3). In systems with a Dual-AMU, take care that the change-over switch for the monitor, keyboard and mouse is switched to the computer which you just switch on. Once the initialization of the first computer is ended, switch this switch over and switch the second computer on.
Step 3 Switch the main switch on (position 1)
The main switch lights up green.
Step 4 Press the <System on> button (only in systems with HICAP)
The <Control on> button lights up green
The AML/J system is supplied with power. The software in the AMU and in the control units starts with the initialization. The status is indicated in the AMU log.
The robot and the storage towers perform a homing run, the gripper functions are tested in conclusion.
Step 5 Check in the $08/RJ that the system has started correctly.
<0700> STATUS: robot ready.

The AML/J system can be stopped normally or switched off in an emer- gency.
The method described under Emergency shutdown may be used only in emergencies.
Proceed as follows to stop the AML/J system normally:
Step 1 Ensure in your application that your application is not endangered by the shut- down ( Documentation of the host software).

Step 3 Click in the "$089"win- dow on the first cell (Shut- down) with the mouse.
Step 4 Click in the now open list on the
Information · 26 line · 4-4 Operation

Step 5 Click with the mouse on the "

$08DQG26 " window
The robot ends its current task and moves into the rest position.
Step 6 Wait until all windows are closed and the message "266\VWHPLVQRZVKXW
GRZQ" is displayed. The process can last rela- tively long (5 minutes).
Step 7 Switch the mains switch on the AMU PC off (PC is located above in the control cabinet)
Step 8 Switch the main switch off
The power supply to the AML/J system is switched off.
Apply the following procedure in an emergency situation.
Except for emergency situations, the AML/J system should be stopped normally before the main switch is switched off. ADIC/GRAU Storage Systems accepts no responsibility for damage because of use of the main switch not as intended. The user bears the entire risk.
The system is not deenergized completely with the main switch.

Step 1 Actuate the main switch
The power voltage of the AML/J is switched off. All movements of the robot are stopped.
The AML/J system is restarted as follows after an emergency shutdown.
Step 1 Rectify all problems which made stopping the AML/J system necessary (if required).
Step 2 Start the AML/J system according to the procedure Starting the AML/J system on page 4-3.
4-6 Operation

This operating mode is intended if the AML/J should be operated with- out the robot because of a robot fault or maintenance. In this operating mode the requirements are displayed in the AMU but the user performs the actions instead of the robot.
Step 1 Shut the system down according to Stopping the AML/J system on page 4-4
Step 2 Open the access doors to the archive
Step 3 Switch the mains switch on the AMU PC on
Step 4 Select the manual operating mode of your host software (HACC/MVS or ROBAR) or on the AMU:
The Manual Operation window is opened.

Step 5 Start your application or repeat still pending Mount- KEEP or Eject tasks.
The task is displayed in the Manual Operation window.
Step 6 In the case of MOUNT remove the cartridge from the rack and place it in the stated drive. In the case of KEEP remove the cartridge from the drive and place it in the I/O unit.
Step 7 Click on 2Nbutton in the 0DQXDO2SHUDWLRQ window
Step 8 Repeat Step 6 and Step 7 until you start in normal mode again.

On switching over the passive AMU becomes the active AMU and if pos- sible, the active AMU becomes the passive AMU. The connections of the connection cables between AMU computer and control unit must be changed over for the change.
Step 1 Stop the command stream to the system:
Step 2 Switch the AML/J off (Stopping the AML/J system on page 4-4).
Step 3 Change over the connections of the following cables at the con- trol rack:
Step 4 Close the side door of the control cabinet
Step 5 Switch the AMU (B) computer on
Step 6 Open the AMU log in the 9LHZ menu with the /RJcommand
Step 7 Switch the main switch S3 on the control rack on
Step 8 Switch the host to the Dual-AMU with the corresponding host command
XJ5
4-8 Operation

Step 9 Check that after switching over the components the system reports that it is ready. If the robots do not report that they are ready, there is another or a further error in the system.
Step 10 Determine which commands have not yet been acknowledged by the AMS software:
Step 11 Determine where the media belonging to the outstanding com- mands are located:
Step 12 Compare these positions with the data in the database of the AMU
Step 13 In the case of discrepancies change the AMU database and in HACC/MVS systems in addition the HACC/MVS database
Step 14 Start the communication to the system
Step 15 Repeat the commands which are still outstanding and still required. Delete the commands which are no longer required from the command queue.

4-10 Operation

The entries on the workspace of the AMS are equivalent to host com- mands for the system.
Take special care in the case of the 3XW, *HW, /RRN and 7HDFK commands that conflicts with the host commands do not arise. In the case of doubt restart the AMU after working with these com- mands.
An AMU restart (AMS and DAS) is essential after a change in the con- figuration.
Make entries on the AMU only in the following case:
All commands or options which cannot be executed are shown shaded.
The layout as well as the application correspond to the SAA standard.
You will find further information in the OS/2 Guides.
Information · Working with the

Control menu Title bar Menu bar Minimize Maximize AMU Release

* %8' $FWLYH - AMU which currently controls the AML %8' 3DVVLYH - AMU inactive, router sends to active AMU %8'$FWLYH 3DUWQHUORVW - no connection to the Dual-AMU
6KXWGRZQLQ3URJUHVV - Shutdown command has been executed
In the active window the title bar is dark; in the inactive window the title bar is light.
The following functions are the same in all windows:
Cancels the current function and closes the win- dow
Opens the online help.

Step 1 Move the mouse pointer to the required menu in the menu bar
Step 2 Click on the menu
5-2 Menus and commands
AMU Status * · Information · Button Function

Step 3 Click on the command in the menu
The command window opens
Step 1 Press and the letter underlined in the menu bar
Step 2 Now press the letter underlined in the menu to select the com- mand
If a key or a key combination is stated next to the command, you can select this command directly with it.
Changeable windows have a surrounding frame (e. g. Trace window).
Step 1 Move the mouse to any corner of the active window
The mouse pointer changes its form to a double arrow
Step 2 Press the mouse button and draw out the window to the required size with the mouse button pressed
Step 1 Move the mouse pointer into the title bar
Step 2 Move the window with the mouse button pressed
Step 1 You close the window by double-clicking on the control menu
The menu opens · The menu opens

All commands of the AMS workspace are explained here:






When the Dual-AMU is used, only the Switch command can be exe- cuted on the passive AMU (also the View Archive Catalog Manage- ment command is not allowed on the passive AMU). Enter all commands on the active AMU.
5-4 Menus and commands
Information

Prepare shutdown of the AML system.

Before shutting down stop the communi- cation with the host computer (e. g. with HOLD 1,1).
1R Return to the program, no shutdown.
Command Field Explanation

Prepare shutdown of the AML system (as in6KXWGRZQ
RQO\$0/6\VWHP) and then break off all processes under OS/2 and perform OS/2 system shutdown.
Before shutting down stop the communi- cation with the host computer (e. g. with HOLD 1,1).
5-6 Menus and commands
Command Field Explanation

&XW Cutting out the marked object and saving it in the clip- board (memory of the computer). Shortcut: Key combination +
&RS\ Copying the marked object into the clipboard. Shortcut: Key combination +
3DVWH Inserting the object from the clipboard at the current cursor position. Shortcut: Key combination +
Command Explanation

Selecting information in different display windows.
Possibility of controlling and changing archive catalogue entries for the compartments.
After entry either of the Volser or selection of a coordinate all associated information from the database is displayed. If a Volser is present several times, only the first entry in the database is displayed.

5-8 Menus and commands

&RRUGLQDWH Logical coordinates of the medium in the archive.
An optical disk occupies 2 logical coordi- nates, one each for the front and reverse side.
The individual places of the coordinates have the fol- lowing contents:
N N S S R R P P
Device No.
List of all device types ( AMU Reference Guide) Select with the aid of the 4 selection fields the required coordinate for the display of the data block of a coordi- nate
0HGLXP Type of the medium for monitoring the archive - drive assignment Medium cannot be changed in the Archive Catalog Management.
A distinction is not made basically between all different types of media with the same media housing.
List of all media types ( AMU Reference Guide)

$WWULEXWH Status of the medium (the characters in brackets are the variables for the database)
2FFXSLHG(O) Medium occupies compartment
(MHFWHG(E) Compartment empty, medium ejected
0RXQWHG(M) Compartment empty, medium in the drive
,QLWLDO(I) Not used attribute
Compartment empty, optical disk in the jukebox
0RXQWHG(R) Compartment empty, optical disk in the drive (reverse side)
(PSW\(Y) Compartment empty
Not defined (special attribute for HACC/MVS)
In AML/2 twin robot system the com- partment in the storage tower is occu- pied temporarily for passing through to the other robot
Occupied compartment in the problem box
7\SH Type of the compartment in the archive
6WRUDJH (S) • Archive compartment for - hierarchically defined Volser ranges - dynamically defined Volser ranges only in HACC/MVS - no Clean
&OHDQ(N) Cleaning media compartment
Type of the compartment in the I/O unit
)RUHLJQ (F) Foreign media compartment
3UREOHP (P) Compartment in the problem box (I/O unit)
5-10 Menus and commands
Field Explanation · $08

Archive compartment for dynamic use of the I/O unit under HACC/MVS
Archive compartment for dynamic use of the I/O unit (in HACC/MVS only for optical disk)
The value of this field can be changed only with a host command.
8VH&RXQW Number of accesses to the compartment. Use Count cannot be changed in the Archive Catalog Management.
&UDVK&RXQW not used
Access right of the robot to the compartment
6WDWXV 0HVVDJH Answer of AMS with message number ( AMU Refer- ence Guide) after an unsuccessful command (e. g. Not found: RC = 1032)

9LHZ &RRUGLQDWH
Display of the archive catalogue entry for the entered logical archive coordinate.
9LHZ1H[W Display of the archive catalogue entry of the next coor- dinate of the component. If the last coordinate is reached, there is no further paging.
9LHZ3UHY Display of the archive catalogue entry of the previous coordinate of the component. If the first coordinate is reached, there is no further paging.
9LHZ9ROVHU Display of the archive catalogue entry for the entered Volser.
This command can be executed only after logging in as administrator or supervisor.
Changing the AMU archive catalogue for the archive coordinate.
The existing entry is only overwritten in the AMU archive catalogue. If there are incorrect entries, discrepancies in the archive and to the HACC/MVS archive catalogue can arise.
5-12 Menus and commands
Command Explanation · 8SGDWH Information

Online or offline trace of the internal processes of the AMU software (AMS and DAS). You can select the traced processes according to areas (processes of the AMU).
Processing can be slowed down by selecting Trace!
Change the selection only after consultation with ADIC/GRAU Stor- age Systems (Support) or ADIC. Standard selection: no traces
The concurrent trace has only a limited memory. Save the trace as quickly as possible in the case of error.

/LVWRI 7UDFH,'·V Select the trace levels with or the mouse. List of all Trace ID’s ( AMU Reference Guide)
Information · Field/com- · mand Explanation

Time of day Trace ID Trace text

2)) The trace is switched off.
21 Writes the current traces in the main memory (1 MB reserved). If the memory is exhausted, the oldest entry is written over.
8QVHOHFW$OO All entries in the online trace window are marked or the marking is removed
)LOHQDPH Path and file name of the trace in binary format, after execution of the 6DYHcommand
6DYH Saving the traces in a file with the name preset in the Filename field in binary format Select this command immediately after occurrence of the problem so that the trace information is not lost. You can print this file with the OS/2 Print command only after formatting ( )RUPDW).
5-14 Menus and commands

)RUPDW Brings a trace file saved with the 6DYHcommand into a printable form (ASCII).

: Target file name with path (e. g. D ?QDPH or
F ?DPX?ORJVWUF?QDPH). starts the formatting. Execution is confirmed by outputting the "IRUPDWWHG
" text.
,QILOH Path and name of the binary trace file for conversion into ASCII format (default: C:?AMU?LOGS-TRC)
2XWILOH Path and name of the ASCII trace file after conversion into ASCII format
Execution of formatting Select this command after you have entered the file names in the,QILOH and
2XWILOH field.
Status display of formatting, formatting is completed at .
fRUPDWW

The Alerter logs all messages (even if the AMU-Log Control Center win- dow is not opened).
Examples:
Log files start daily at 0.00 hours. If the available memory on the hard disk drops below a value defined in the ARTCFG.DAT configuration file (default 40 MB), the oldest log files are deleted.
Log files cannot extend over several days! There is only one log file for each day.

5-16 Menus and commands

/RJDUFKLYH Opens a window for selecting the saved log files with automatic display in the OS/2 editor EPM
The log file name is composed of lo .001

List with all files saved in the defined log folder
Status information (e.g. number of log files or selection)
Status information (e.g. path name or instruction for opening file)
View Copies the selected file into a temporary file (logview.txt). This file is displayed in the OS/2 editor EPM and can be edited further as desired.
Field/command Explanation

)RQWVL]H Selection of font, size and style for the contents in the

1DPH Drop-down list box for all installed fonts
6L]H Drop-down list box of the size for the selected font in pt
6W\OH Drop-down list box of the style of the selected font (available only for certain fonts)
'LVSOD\ Selection of the screen fonts, do not change the setting
6WULNHRXW Struck through type
6DPSOH Display of an example of the selected font
2N Activates the selection for the current AMU log. On renewed opening of the AMU Log window, the default font (sys- tem VIO) is used again.
5-18 Menus and commands

To use the disabled functions in the Operator menu, you must log in as operator, administrator or supervi- sor For protection against unauthorized use, you should log off after the application

3DVVZRUG Field for entering the operator password. You receive this password from your sys- tem administrator
2N Execution of the login process
Command Field Explanation · 2SHUDWRU Logoff

Manual execution of the host commands of 0RXQW and (MHFW by the oper- ator.
Step 1 Switch the main switch off
Step 2 In the case of 0RXQWcommands, mount the cartridge in the stated drive
Step 3 Confirm the execution of the displayed command with 2.
The executed task is acknowledged to the host computer and this shows the next command
Step 4 On resumption of the automatic mode, perform an insertion operation for all cartridges used in the manual mode
&RPPDQG Command of the host which should be performed by the operator
9ROVHU Search in /RFDWLRQ for the Volser or VSN to execute the command
5-20 Menus and commands
Command/ · field Explanation

/RFDWLRQ Statement of the coordinates in the archive where the
9ROVHU for the command is currently located
8QLW Number of the storage tower or rack
6HJP Number of the segments for the storage towers
5RZ Row in the segment (counting from below to above)
3RV Compartment (counting from left to right)
1DPH Designation (comment) which is allocated to the component in the configuration
'ULYH Place the medium with the 9ROVHU in the drive desig- nated in this field With an EJECT command (ejection) the field remains free
1DPH Designation (comment) which is allocated to the drive in the configuration
5HMHFW Actuate if the command has not been executed by the operator. Database update is not performed, host receives nega- tive response
Command/ · field Explanation

Dialog box for starting the ejection of preselected media in an emergency (Disaster Recovery). The window is divided into two sections for inde- pendent rejection of the media in AML/2 twin robot systems.

)LOH Drop-down list box for selecting the prepared files with Volsers for ejection. Display of all files in the C:\AMU\RECOVERY\ folder with file name *.DSR ( AMU Reference Guide)
6WDUW Starting the ejection of the media from the selected file
6WRS Interruption of ejection
6WDWXV Display of the current situation on ejection
5-22 Menus and commands
Command/ · field Explanation

The functions of the Admin menu item are described in the AMU Refer- ence Guide.
To use the disabled functions in the Admin menu you must log in as administrator or supervisor For protection against unauthorized use you should log off again after the application

3DVVZRUG Field for entering the administrator password. You receive this password from your service partner, ADIC/GRAU Storage Systems or ADIC
2N Execution of the login process.
Command Field Explanation · WUDWRU Log- off

&ORVHDOO Closing all opened windows
:LQGRZ (list of all opened windows)
Selection of the corresponding window
5-24 Menus and commands
Command Explanation

Information of the use of the start page of the help functions.

Command Explanation

Start page for the AMU online help.

5-26 Menus and commands
Command Explanation

+HOSLQGH[ Help index

$ERXW Display of the copyright and of the AMU version No.

Command Explanation

5-28 Menus and commands

6.1 Overview
In the normal operating procedure cartridges must be added to the AML/J or removed from it. Three types of I/O units are available for inserting or ejecting cartridges.
There are different functional ranges in the I/O unit for the different applications:

The "Foreign", "HACC Dynamic" and "AMU Dynamic" ranges are defined in the Logical Ranges function in the AMS.
Problem Foreign HACC Dynamic
Configurable range in the magazines
with extra large compartments
Use Cartridges which are mechanically damaged or cannot be iden- tified by the sys- tem, partially also storage of used cleaning media
Cartridges with labels foreign to the system (no or not reada- ble barcode)
Cartridges which should be inserted or ejected with HACC/MVS
Cartridges which should be inserted or ejected with all applica- tions except for HACC/ MVS
Not possible Not possible With com- mands of the HACC/MVS host software
Automati- cally after changes (removal of the magazine)
Only storage Transport from and to the drive, in the case of problems to the problem box
Transport from and to the archive
Transport from and to the archive or to the drive
Volser Symbolic Volser com- mencing with the symbol "*" e.g. "*FR001"
Alphanu- meric Volser with one to 16 characters
Before using the I/O unit obtain information about the configuration of the ranges in your system:


Illuminated pushbutton S85
Production is not interrupted when inserting cartridges through the I/O unit. Insert the cartridges in the I/O unit as follows:
I/O unit/C handle · I/O unit/C window

New cartridges are inserted in the AML/J through the I/O unit.
Step 1 Press the button on the I/O unit
The button on the I/O unit lights up green and the I/O unit is unlocked
Step 2 Open the door of the I/O unit
Step 3 Empty the problem box places if cartridges are there
Step 4 Insert the cartridges in the I/O unit. Pay attention to the correct position.
Step 5 Close the door of the I/O unit
The AML/J locks the I/O unit . According to configuration, the robot checks the magazine (barcode or empty place) on the cartridges.
Step 6 Move the cartridge with the aid of the host software into the archive (exception: foreign mount cartridges)
The cartridges are brought into the archive.
6-4 Processing media

Cartridges are ejected from the AML/J through the I/O unit.
Production is not interrupted when ejecting cartridges with the I/O unit. Eject the cartridges as follows with the I/O unit:
Step 1 Perform the ejection command from your application or HOST software.
The cartridges are brought into the I/O unit
Step 2 Press the button on the I/O unit
The button on the I/O unit lights up green and the I/O unit is unlocked
Step 3 Open the door of the I/O unit
Step 4 Empty the problem box places if cartridges are there
Step 5 Remove the cartridges from the I/O unit
Step 6 Close the door of the I/O unit
The AML/J locks the I/O unit . According to configuration the robot checks the magazine (barcode or empty place) on the cartridges.


Operating button Door lock
I/O unit segment 1 (coordinates of E60x010101)
I/O unit segment 2 (coordinates of E60x020101)
Production is interrupted when inserting cartridges through the I/O unit/D. Insert the cartridges in the I/O unit as follows:
I/O unit electromagnetic · 6-6 Processing media

New cartridges are inserted in the AML/J through the I/O unit.
Step 1 Press the button on the I/O unit
The robot moves into the rest position. The power voltage of the robot control is switched off. The button on the I/O unit lights up green and the I/O unit is unlocked.
Step 2 Open the door of the I/O unit
Step 3 Insert the cartridges in the I/O unit. Pay attention to the correct position.
Step 4 Close the door of the I/O unit
Step 5 Press the button
The power voltage is switched back on. The AML/J locks the I/O unit. The robot performs a homing run. According to configuration the robot checks the magazine (barcode or empty place) on the cartridges.
Step 6 Move the cartridge with the aid of the host software into the archive (exception: foreign mount cartridges)
The cartridges are brought into the archive.

Cartridges are ejected from the AML/J through the I/O unit.
Production is not interrupted when ejecting cartridges with the I/O unit. Eject the cartridges as follows with the I/O unit:
Step 1 Perform the ejection command by your application or HOST software.
The cartridges are brought into the I/O unit
Step 2 Press the button on the I/O unit
The robot moves into the rest position. The power voltage of the robot control is switched off. The button on the I/O unit lights up green and the I/O unit is unlocked.
Step 3 Open the door of the I/O unit
Step 4 Remove the cartridges from the I/O unit
Step 5 Close the door of the I/O unit
Step 6 Press the button
The power voltage is switched back on. The AML/J locks the I/O unit. The robot performs a homing run. According to configuration the robot checks the magazine (barcode or empty place) on the cartridges.
6-8 Processing media

New cartridges are inserted in the AML/J through the I/O unit.
Step 1 Press the button on the I/O unit
The button lights up green. On release by the robot control the shutter is unlocked.
Step 2 Open the shutter of the I/O unit
Step 3 Pull out the slide of the I/O unit
Step 4 Remove the magazine
Step 5 Insert the cartridges in the magazine. Pay attention to the cor- rect position.
Step 6 Put the magazine back in the I/O unit
Step 7 Push the slide back in
Step 8 Close the shutter of the I/O unit
The AML/J locks the shutter of the I/O unit . According to configuration the robot checks the magazine (barcode or empty place) on the cartridges.
Step 9 Move the cartridge with the aid of the host software into the archive (exception: foreign mount cartridges)
The cartridges are brought into the archive.
Door lock · Requirement button · Shutter

Cartridges are ejected from the AML/J through the I/O unit.
Production is not interrupted when ejecting cartridges with the I/O unit. Eject the cartridges as follows with the I/O unit:
Step 1 Perform the ejection command by your application or HOST software
The cartridges are brought into the I/O unit
Step 2 Press the button on the I/O unit.
The button lights up green. On release by the robot control the shutter is unlocked.
Step 3 Open the shutter of the I/O unit
Step 4 Pull out the slide of the I/O unit
Step 5 Remove the magazine
Step 6 Remove the cartridges from the magazine
Step 7 Put the magazine back in the I/O unit
Step 8 Push the slide back in
Step 9 Close the shutter of the I/O unit
The AML/J locks the shutter of the I/O unit . According to configuration the robot checks the magazine (barcode or empty place) on the cartridges.
6-10 Processing media

The Disaster Recovery function enables cartridges to be ejected, corre- sponding to a previously defined list (file) without host connection. The function is used after a failure of the host system for preparing the move into an alternate computer center.
Step 1 Unload all drives
Step 2 Bring these media back into the home position with the .((3 command
Step 3 Perform a login in the operator menu.
Step 4 Select the 'LVDVWHU5HFRYHU\ command in the 2SHUDWRU menu
Step 5 Enter the password (defined in 3URFHVV&RQILJXUDWLRQ)
The Disaster Recovery window is opened.
Step 6 Select the file for ejection

The entire I/O unit is used for disaster recovery (incl. foreign mount compartments)
Step 7 Start the ejection with 6WDUW
Step 8 Empty all media from all I/O units as requested
Step 9 Confirm ejection with 2.
The media are ejected in the order specified in the selected file
Step 10 Empty the I/O unit if the request appears on the workspace
Step 11 Continue ejection with 2.
The command is acknowledged positively after ejection of the last medium.
Information · 6-12 Processing media

A
B
About 5-27 Address
Barcode scanner 2-2
ADIC 1-3 ADIC/GRAU Storage Systems 1-3 Admin menu 5-23 AML Controller User Guide 1-2 AML Management Unit 2-3 AML/J control unit 2-2 AML/J Maintenance Guide 1-2 AMU 2-3
Cartridge 2-7 Clean 5-10 Close
all 5-24 Command
Select 5-2 Communication 2-4 Compartment addressing 2-5 Components of the system
Communication 2-4 Copyright/Version 5-27 Hardware 2-4 Help 5-25 Software 2-4 Tasks 2-4 User interface 2-4 Workspace 5-1 AMU Installation Guide 1-2 AMU Log 5-16 AMU Problem Determination Guide . . . 1-2 AMU Reference Guide 1-2 Attribute 5-10
Control cabinet 2-3 Control cabinet 2-3 Control menu 5-2 CONTROL ON 4-2 Coordinate 5-9 Coordinates 2-5 Copy 5-7 Crash Count 5-11 Cut 5-7

G
Gripper 2-2 Guide
Electrical system 2-9 Description of function 2-2 Disaster Recovery 6-11 Drive 2-2 Drives 2-6 Dynamic
Further information 1-2 Layout 1-1
Help menu 5-25 HICAP 6-6 Homing run 4-3 Host connection 2-1
AMU 5-10, 5-11 HACC/MVS 5-11
Menu 5-7 Ejected 5-10 Ejecting cartridges 6-5, 6-8, 6-10 Electrical data 2-9 Electrical fuses 2-9 Emergency shutdown 4-5 Empty 5-10
I/O unit 2-6, 2-7 I/O unit/C 6-3 I/O unit/D (HICAP) 6-6 I/O unit/E 6-9 Illuminated pushbutton
CONTROL ON 4-2 In Jukebox 5-10 Initial 5-10 Inserting cartridges 6-4, 6-7, 6-9
Fault 5-1 Field
Maximize 5-2 Symbol 5-2 Font size 5-18 Foreign 5-10 Format (Trace) 5-15 Functional unit 2-2 Fuses 2-9
Keyboard 5-1
Layout of the windows 5-2 Log 5-16 Logical coordinates 2-5
Data · Edit · in-ii Index

Reverse Side Mounted 5-10 Robot 2-6 Robot system
Main switch 3-5 Manual Operation 5-20 Mechanical lock 3-5 Menu
Homing run 4-3
Admin 5-23 Edit 5-7 Help 5-25 Operations 5-19 Overview 5-4 Shutdown (AMU) 5-5 View 5-8 Window 5-24 Menu bar 5-2 Mounted 5-10 Mouse 5-1
Scratch-Status 5-11 Select online help 5-2 Selecting a command 5-2 Shortcut 5-3 Shutdown AMU 5-5 Shutdown AMU (completely) 5-6 Shutdown menu 5-5 Starting the AML/J 4-3 Stopping the AML/J 4-4
Emergency shutdown 4-5 Normal stoppping 4-4 Storage 5-10 Storage cells 2-2, 2-5, 2-6 Switching off with Shutdown AMU 5-5 Switching off with Shutdown AMU (complete-
Normal stopping 4-4
ly) 5-6 Symbols
Occupied 5-10 Operations menu 5-19
Electrical system 2-9 System description 2-1
Paste 5-7 Problem 5-10 Protective devices
Main switch 3-5 Mechanical lock 3-5
Target group 1-1 Technical support 1-3 Temp
Away 5-10 Here 5-10
Restarting the AML/J 4-6
iii March 31, 1999

Title bar 5-2
Undefined 5-10 Update
Coordinate 5-12 Use as intended
AML/J-System 3-2 Use Count 5-11
Coordinate 5-12 Menu 5-8 Volser 5-12 Volser 2-2, 2-7 Volume Serial Number 2-2, 2-7 VType 5-11
Corner 5-2 Frame 5-2 Window menu 5-24 Windows
Change size 5-3 Close 5-3 Layout 5-2 Move 5-3
View · in-iv Index
Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.