Gebruiksaanwijzing /service van het product CW-APS van de fabrikant Bunn
Ga naar pagina of 24
OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION OF CANADA LTD. 280 INDUSTRIAL P ARKW A Y SOUTH AURORA, ONT ARIO L4G 3T9 PHONE: (905) 841-2866 F AX: (905) 841-2775 10690.
Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for either pour-over or automatic brewing. The automatic version may include a hot water faucet for allied beverage use.
Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. # 00831.7000 Fill water tank before turning -on thermostat or connecting appliance to power source.
Page 4 120V.A.C. NEUTRAL WHITE L1 BLACK NEUTRAL WHITE L1 BLACK 208 or 240V.A.C. 120V.A.C. 120V.A.C. L2 RED ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.
Page 5 10165.0000D 6/93 © 1988 BUNN-O-MATIC CORPORATION BE SURE TO INSTALL THE ABOVE ASSEMBLY AS SHOWN Models CWT-APS, CWT-TS 1. Attach the flare fitting from the short piece of tubing on the flow control (supplied) to the water inlet fitting at the left rear of the brewer.
Page 6 INITIAL SET -UP CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Insert an empty funnel into the funnel rails. 2. Place an empty dispenser under the funnel.
Page 7 OPERA TING CONTROLS Models CW-APS & CW-TS: These models function without operating controls. Models CWT-APS, CWTF-APS, CWT-TS, CWTF-TS: ON/OFF SWITCH Placing the "ON/OFF" switch in the "OFF" lower position stops brewing.
Page 8 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
Page 9 TROUBLESHOOTING (cont.) PROBLEM Brew cycle will not start (cont.) (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS) Water is not hot PROBABLE CAUSE REMEDY 5. Timer 6. Solenoid Valve 7. Water strainer/flow control (.222 GPM) 1. Tank Heater Switch 2. Limit Thermostat CAUTION - Do not eliminate or bypass limit thermostat.
Page 10 TROUBLESHOOTING (cont.) PROBLEM Inconsistent beverage level in dispenser Consistently low beverage level in the dispenser (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS) Spitting or excessive steaming PROBABLE CAUSE 1. Strainer /flow control (.222 GPM) (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS) 2.
Page 11 TROUBLESHOOTING (cont.) PROBLEM Spitting or excessive steaming (cont.) Dripping from sprayhead Water flows into tank continu- ously (ON/OFF Switch "ON") Water flows into tank continu- ously (ON/OFF Switch "OFF") Beverage overflows dispenser PROBABLE CAUSE 2.
Page 12 TROUBLESHOOTING (cont.) PROBLEM Weak beverage Dry coffee grounds remain in the funnel Brewer is making unusal noises (CWT-APS, CWTF-APS, CWT- TS, CWTF-TS) PROBABLE CAUSE 1. Filter Type 2. Coffee Grind 3. Sprayhead 4. Funnel Loading 5. Water Temperature 1.
Page 13 TROUBLESHOOTING (cont.) PROBLEM Brewer is making unusal noises (cont.)(CWT-APS, CWTF-APS, CWT-TS, CWTF-TS) Brewer is making unusal noises (CW) PROBABLE CAUSE 4. Tank Heater 1. Tank Heater REMEDY Remove and clean lime off the tank heater. See page 19 Remove and clean lime off the tank heater.
Page 14 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary.
Page 15 SERVICE (cont.) CONTROL THERMOSTAT 1 2 3 4 5 .5 MINUTES BUNN-O-MATIC P/N 2235-120 VAC USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTIONS B U N N C W S E R I E S R E A D Y LATE MODELS Location: Early Models: The control thermostat is mounted on a bracket inside the hood on the right side just in front of the tank lid.
Page 16 SERVICE (cont.) CONTROL THERMOSTAT (cont.) 3. Early Models: Remove the two #8-32 screws securing control thermostat bracket mounted inside the hood. Late Models: Remove the one #8-32 screw se- curing the control thermostat to the component bracket in the trunk.
Page 17 SERVICE (cont.) ON/OFF SWITCH BUNN M A N U F A C T U R E D B Y B U N N - O - M A T I C C O R P O R A T I O N S P R I N G F I E L D , I L L I N O I S , U .
Page 18 SERVICE (cont.) SOLENOID VALVE 1 2 3 4 5 .5 MINUTES BUNN-O-MATIC P/N 2235-120 VAC USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTIONS B U N N C W S E R I E S R E A D Y P1127 Location: The solenoid valve is located inside the trunk on the center lower part of the component bracket.
Page 19 SERVICE (cont.) START SWITCH B U N N M A N U F A C T U R E D B Y B U N N - O - M A T I C C O R P O R A T I O N S P R I N G F I E L D , I L L I N O I S , U .
Page 20 SERVICE (cont.) TANK HEATER (Cont.) If voltage is present as described, proceed to #4 If voltage is not present as described, refer to the Wiring Diagrams and check wiring harness. 4. Disconnect the black wire and the white wire or red wire from the tank heater terminals.
Page 21 SERVICE (cont.) TANK HEATER SWITCH 1 2 3 4 5 .5 MINUTES BUNN-O-MATIC P/N 2235-120 VAC USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTIONS B U N N C W S E R I E S R E A D Y P1127 Location: The tank heater switch is located on the rear of the brewer on the upper left side of the trunk.
Page 22 SERVICE (cont.) TANK HEATER SWITCH (cont.) 15. Set tank assembly inside the hood on mounting brackets and secure with two #8-32 screws. 16. Reconnect the wires to the limit thermostat, tank heater and the control thermostat. Refer to limit thermostat, tank heater and control thermostat sections in this manual when reconnecting wires.
Page 23 SERVICE (cont.) TIMER (cont.) with a voltmeter when the "ON/OFF" switch is in the "ON" position (upper) and start switch pressed. Connect the brewer to the power source. The indication must be 120 volts ac for two wire 120 volt models and three wire 120/240 volt models.
Page 24 120/240 VOLTS AC 3 WIRE 120 VOLTS AC 2 WIRE SINGLE PHASE MODEL 15 1320W @ 120V MODEL 20 1800W @ 120V MODEL 35 3500W @ 240V P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR. WHI BLK SOL BLU BLU WHI BREW TIMER BLK P1 P3 P2 WHI OPTIONAL AUTOMATIC BREW CIRCUIT SCHEMATIC WIRING DIAGRAM FOR CW, CWT, CWTF - APS, TS,TSR 10693.
Een belangrijk punt na aankoop van elk apparaat Bunn CW-APS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bunn CW-APS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bunn CW-APS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bunn CW-APS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bunn CW-APS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bunn CW-APS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bunn CW-APS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bunn CW-APS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.