Gebruiksaanwijzing /service van het product VPR APS van de fabrikant Bunn
Ga naar pagina of 12
OPERA TING & SER VICE MANUAL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 39064.
Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser . It is only for indoor use on a sturdy counter or shelf.
Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition.
Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power sour ce until specifi ed in Initial Set-Up. The brewer has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.
Page 5 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department.
Page 6 TROUBLESHOOTING (cont.) PROBLEM Dripping from sprayhead Beverage overfl ows dispenser Weak beverage PROBABLE CAUSE REMEDY 1. Lime Build-up CAUTION - T ank and tank com- ponents should be delimed regularly depending on local water conditions.
Page 7 TROUBLESHOOTING (cont.) PROBLEM Dry coffee grounds remain in the funnel Brewer is making unusal noises PROBABLE CAUSE REMEDY 1. Funnel Loading 1. T ank Heater The BUNN ® paper fi lter must be centered in the funnel and the bed of grounds leveled by gently shaking.
Page 8 FIG. 3 CONTROL THERMOST A T CONTROL THERMOST A T SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessar y . Refer to T roubleshooting for assistance in determining the cause of any problem.
Page 9 Location: The control thermostat is located inside the hood on the left end of the mounting bracket. T est Procedures: 1. Disconnect the brewer from the power sour ce. 2. Locate the black wire on the control thermo- stat. 3. Check voltage across the black wire on the control thermostat and the white wire on the tank heater with a voltmeter .
Page 10 FIG. 6 LIMIT THERMOST A T TERMINALS SERVICE (cont.) LIMIT THERMOST A T Location: The limit thermostat is located inside the hood on the right side of the tank lid. T est Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the blue/black and black wires from the limit thermostat.
Page 11 SERVICE (cont.) If continuity is present as described, reconnect the wires, the tank heater is operating properly . If continuity is not present as described, replace the tank heater . NOTE- If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath.
Page 12 L1 BLK T ANK HEA TER WHI LOWER WARMER "KEEP WARM" HEA TER WHI BLK SCHEMA TIC WIRING DIAGRAM VPR, VPR TC & VPR APS GREEN N WHI WHI BLK 33769.0000C 03/06 © 2001 BUNN - O - MA TIC CORPORA TION UPPER WARMER WHI BLK 120 VOL TS A C 2 WIRE SINGLE PHASE 60 HZ WHI/RED VIO LIMIT THERMOST A T BLU/BLK SW .
Een belangrijk punt na aankoop van elk apparaat Bunn VPR APS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bunn VPR APS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bunn VPR APS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bunn VPR APS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bunn VPR APS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bunn VPR APS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bunn VPR APS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bunn VPR APS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.