MONO CLASS D AMPLIFIERS.
INTRODUCTION 2 Thank you for purchasing a Cadence T ype RS amplifier . Over the past years, the technology used to create audio amplifiers has grown by leaps and bounds. W e have thousands of satisfied customers still using our first generation Ultra Drive amplifiers which are almost 10 years old.
FEA TURES 3 GOLD PLA TED TERMINALS: BASS DRIVE EQUALIZA TION CIRCUITRY : “ADR”: - ACTIVE DYNAMIC REGULA TION CLASS D AUDIO ST AGE PERFORMANCE POWER AND PROTECTION CIRCUITR Y : STIFFENING CAP ACITO.
FEA TURES 4 “ARV A” - AUTOMA TIC RAIL VOL T AGE ADJUSTMENT CIRCUITR Y : AMPLIFIER MODE SWITCH BA TTERY VOL T AGE: INDUCTION AND TUNNEL F AN COOLING: PROTECTION CIRCUITR Y : Cadence RS amplifiers feature "ARV A" circuitry in their power supply .
INST ALLA TION BASICS 5 INST ALLA TION BASICS: REMOTE TURN ON CONECTION: STIFFENING CAP ACITOR DIRECT CONNECTION: USING THE RS AMPLIFIERS IN CONJUNCTION WITH A MUL TI- CHANNEL AMPLIFIER: POWER/GROUND WIRING: Before you begin with your installation disconnect the NEGA TIVE (-) terminal from your car's battery .
MOUNTING 6 MOUNTING THE RS AMPLIFIERS: 1 A B A 2 3 Choose a convenient mounting location with unobstructed airflow . 1 - Mount and fasten amplifier bracket A onto the mounting surface, with two screws as shown. 2 - Slide the amplifier so that hook B engages with bracket A.
Remote turn on Remote turn on Mode switch Line level inputs from head unit S tereo RCA cable from RS LINE OUT to highs amp LINE IN CPR Remote Control Woofer 1 ohm minimum High frequency speakers Groun.
USING THE CPR REMOTE CONTROL WITH THE RS AMPLIFIERS 8 CPR (COMPETITION PODIUM REMOTE) BASICS LEVEL CONTROL: BURST BUTTON: DIGIT AL BA TTERY VOL T AGE MONITOR: POWER BARGRAPH: INST ALLA TION: The optional CPR remote control can be used for street or SPL competitions alike.
ADJUSTING THE SYSTEM 9 SETTING THE TOP P ANEL CONTROLS ADJUSTING THE SYSTEM AUDIO PREAMP INPUT AUDIO PREAMP OUTPUT USING THE BUIL T-IN LOW P ASS ELECTRONIC CROSSOVER SUBSONIC FIL TERING . PHASE SHIFT CONTROL AMPLIFIER MODE SWITCH The RS amplifiers feature RCA preamp inputs.
MASTER/SLA VE CONNECTION DIAGRAM MONO BRIDGING 2 AMPLIFIERS INTO 1 WOOFER 10 Mode switch Mode switch 2 ohm minimum AMPLIFIER MODE SWITCH, INPUTS AND REMOTE CONTROL Set the AMPLIFIER MODE switches as shown Connect the source to the master amplifier inputs, and an optional CPR remote control to the master , as shown.
MONO BRIDGING MUL TIPLE P AIRS OF AMPLIFIERS 2 OR MORE AMPLIFIERS WITH SEP ARA TE SPEAKERS IMPORT ANT : Note the reverse speaker phase on 2nd amplifier IMPORT ANT : Reverse the speaker phase on every .
BASIC SPEAKER WIRING DIAGRAMS FOR V ARIOUS LOADS 12 4 OHM 8 OHM 2 OHM 4 OHM 1 OHM TO AMPLIFIER 2 OHM TO AMPLIFIER 4 OHM TO AMPLIFIER 8 OHM TO AMPLIFIER 1 OHM TO AMPLIFIER 2 OHM TO AMPLIFIER + + + + + .
ADV ANCED SPEAKER WIRING DIAGRAMS FOR V ARIOUS LOADS 13 P ARALLEL: DUAL VOICE COIL SPEAKERS 3 X DUAL VC 8 OHM SPEAKERS WITH P ARALLEL VOICE COILS, IN P ARALLEL 2 X DUAL VC 4 OHM SPEAKERS WITH P ARALLE.
TROUBLESHOOTING 14 GENERAL TOOLS NEEDED NO SOUND By utilizing this process of elimination you can determine where the cause of the problem is. If the amplifier goes in to diagnostic with nothing connected to it, and you are sure of proper power and ground, please contact our service dep artment for further help ay 732 370 5400.
SPECIFICA TIONS 15 Due to constant product improvements, these specifications are subject to change without notice. High current rated powers are at amplifier minimum distortion and are for competition purposes. Not responsible for typographical errors.
MONO CLASS D AMPLIFIERS.
Een belangrijk punt na aankoop van elk apparaat Cadence MONO CLASS D (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Cadence MONO CLASS D heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Cadence MONO CLASS D vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Cadence MONO CLASS D leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Cadence MONO CLASS D krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Cadence MONO CLASS D bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Cadence MONO CLASS D kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Cadence MONO CLASS D . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.