Carrier 48SS036

8 pagina's·604 KB·Airconditioner·PDF·EN
Carrier 48SS036
Inhoudsopgave 36 secties 48SS-3SB · 48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ · ELECTRIC COOLING UNITS · — PERFORMANCE DATA — CERTIFIED DIMENSION PRINT — CERTIFIED ROOF CURB · … TonenVerbergen
Page 1 of the Carrier 48SS036 user manual — R 1997 Carrier Corporation • Syracuse, New York 13221
Pagina 1 · klik om te vergroten
Pagina 1
Carrier 48SS036 — 48SS-3SB diagram (page 1)
Afb. 1

48SS-3SB

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/

ELECTRIC COOLING UNITS

— PERFORMANCE DATA — CERTIFIED DIMENSION PRINT — CERTIFIED ROOF CURB

DIMENSION PRINT

R 1997 Carrier Corporation • Syracuse, New York 13221

Form 48SS-3SB Supersedes 48SS-2SB Printed in U.S.A. 5-97 Catalog No. 514-847

Page 2 of the Carrier 48SS036 user manual — Minimum Circuit Amps Maximum Overcurrent Protection
Pagina 2 · klik om te vergroten
Pagina 2

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/

Date: Supersedes:

48SS Rev.:

-3SB

ELECTRIC COOLING UNITS

JOB DATA: LOCATION:

BUYER: BUYER P.O. # CARRIER #

UNIT NUMBER: MODEL NUMBER:

PERFORMANCE DATA CERTIFIED BY: DATE:

DESCRIPTION 48SS units are standard-efficiency, one-piece gas heating electric cooling units, pre-wired and pre-charged at the factory.

48SS units are convertible discharge units that can be used for either horizon- tal or down discharge installations.

ARI 210 ARI 270

FEATURES

Standard one-year warranty. Five-year Extended Protection Plan for the compressor. Ten-year non-prorated warranty on heat exchanger. Units are ‘‘Rated in accordance with ARI Standard No. 270 and 210/240.’’ Standard unit as factory assembled is design certified and listed by UL and CSA. Low temperature cooling operation standard to 40 F (4 C). Hermetic compressor with internal linebreak and overload protec- tion, self lubricating. Scroll compressors on 4 and 5 ton sizes. Crankcase heater is standard on 024-042 3-phase units. (Not re- quired on 018, 048 and 060 units.) Indoor and outdoor coils constructed of aluminum fins mechan- ically bonded to seamless copper tubes. 48SS units have single-stage cooling and heating. Foil-faced cleanable insulation. Sloped non-corrosive condensate drain pan.

Single-point gas connection. Alternate electrical connections on opposite sides of unit. Disconnect in accordance with NEC, must be field-supplied and installed. Multi-speed, direct drive indoor fan motor. Weatherized cabinets. Heavy duty phosphated zinc-coated pre- painted steel. Capable of withstanding 500-hour salt spray. 24-volt control circuit. Heating controls include a direct spark ignition with flame rectification. Fan switch, overtemperature switch, and flame roll- out switch also included. Induced-draft with hall effect sensor (to prove proper inducer draft motor operation). Alumaguard™coated ‘‘Super-S’’ four-pass heat exchanger. Integrated gas control board provides anti-cycle protection for gas heat operation. Base rail standard on all 3-phase units.

PERFORMANCE DATA Operating Weight lb (unit); lb (curb)

CFM Ext. Static Pressure in. wg

COOLING Net Total Capacity Btuh Net Sensible Capacity Btuh Compressor Power Input kW @ °F Outdoor-Air Temperature Indoor Entering Air db °F wb °F SEER/EER

Indoor Fan Motor Hp Rpm Bhp

HEATING Input Btuh

Output Btuh

AFUE %

ELECTRICAL DATA Power Supply to Unit Volts Phase Hz.

Minimum Circuit Amps Maximum Overcurrent Protection

ACCESSORIES AND OPTIONS

FACTORY-INSTALLED OPTIONS M Commercial Grade Base Rail M Dedicated Downshot/Base Rail

FIELD-INSTALLED ACCESSORIES (cont) M Programmable Electronic Thermostat M Thermostat and Subbase M 0° Low Ambient M Time Guardt II M L.P. Conversion Kit M Controls Upgrade Kit (High and Low-Pressure Switch) M External Condensate Trap M Natural Gas High-Altitude Kit (2000-5000 ft Above Sea Level)

FIELD-INSTALLED ACCESSORIES M 30% Open Manual Fresh Air Damper M Roof Curb: M 89 Height M 119 Height M 149 Height M One-in. Filter Rack M Crankcase Heater — Single Phase Only (Required with 0° Low Ambient)

Page 3 of the Carrier 48SS036 user manual — REQ’D CLEARANCES TO COMBUSTIBLE MAT’L
Pagina 3 · klik om te vergroten
Pagina 3

018040 208/230-1-60 272 123 81/37 62/28 76/35 53/24 024040 208/230-1-60 303 138 97/44 43/20 123/56 40/18 024060 208/230-1-60 315 143 100/45 46/21 126/57 43/20 030040 208/230-1-60 320 145 100/45 47/21 126/57 47/21 030060/080 208/230-1-60 324 147 94/43 63/29 115/52 52/24 036060/080 208/230-1-60 336 153 86/39 76/35 111/50 63/29 036100/120 208/230-1-60 348 158 89/40 79/36 114/52 66/30 042060/080 208/230-1-60 375 170 95/43 86/39 119/54 75/34 042100/120 208/230-1-60 387 176 98/45 89/40 122/55 78/35

018040 24.12/612.8 169⁄16/420.7 1815⁄16/481.0 25.07/637 20.59/523 10.85/276 024040 24.12/612.8 169⁄16/420.7 1815⁄16/481.0 27.07/688 23.35/693 10.85/276 024060 24.12/612.8 169⁄16/420.7 1815⁄16/481.0 26.98/685 23.27/591 10.85/276 030040 24.12/612.8 169⁄16/420.7 1815⁄16/481.0 26.71/678 23.46/596 10.85/276 030060/080 24.12/612.8 169⁄16/420.7 1815⁄16/481.0 27.15/689 22.36/568 10.85/276 036060/080 24.12/612.8 169⁄16/420.7 1815⁄16/481.0 27.50/698 22.48/571 10.85/276 036100/120 24.12/612.8 169⁄16/420.7 1815⁄16/481.0 27.40/696 22.44/570 10.85/276 042060/080 28.12/714.2 209⁄16/522.3 2215⁄16/582.6 27.01/686 22.44/570 12.65/321 042100/120 28.12/714.2 209⁄16/522.3 2215⁄16/582.6 26.94/684 22.44/570 12.65/321

(in./mm) CENTER OF GRAVITY

E F G X Y Z

WEIGHT CORNER WEIGHT

(in./mm) DIMENSION

CHARACTERISTICS

HEIGHT

Maximum Extension of Overhangs 48 (1219.2)

Between Units, Control Box Side 42 (1066.8)

Control Box Side 36 (914.4)

Grounded Surfaces, Control Box Side . . . 42 (1066.8)

REQ’D CLEARANCES FOR SERVICING — in. (mm)

NEC (National Electrical Code) REQ’D CLEARANCES

REQ’D CLEARANCES TO COMBUSTIBLE MAT’L

Unit and Block or Concrete Walls and Other

lation of air from outdoor fan discharge.

Unit and Ungrounded Surfaces,

(lb/kg)

Page 4 of the Carrier 48SS036 user manual — REQ’D CLEARANCES TO COMBUSTIBLE
Pagina 4 · klik om te vergroten
Pagina 4

018040 208/230-1-60 296 135 87/40 68/31 82/37 59/27

024040 208/230-1-60 327 149 103/47 49/22 129/59 46/21

024060 208/230-1-60 339 155 106/48 52/24 132/60 49/22

030040 208/230-1-60, 208/230-3-60 344 157 106/48 53/24 132/60 53/24

030060/080 208/230-1-60, 208/230-3-60 356 162 102/46 71/32 123/56 60/27

036060/080 208/230-1-60, 208/230-3-60, 460-3-60, 575-3-60 360 164 92/42 82/37 117/53 69/31

036100/120 208/230-1-60, 208/230-3-60, 460-3-60, 575-3-60 372 169 95/43 85/39 120/55 72/33

042060/080 208/230-1-60, 208/230-3-60, 460-3-60 399 181 101/46 92/42 125/57 81/37

042100/120 208/230-1-60, 208/230-3-60 460-3-60 411 187 104/47 95/43 128/58 84/38

018040 27.43/696.7 197⁄8/504.8 221⁄4/565.4 25.04/636.0 22.72/577.0 13.16/334.3

024040 27.43/696.7 197⁄8/504.8 221⁄4/565.4 26.90/683.3 20.17/512.3 13.16/334.3

024060 27.43/696.7 197⁄8/504.8 221⁄4/565.4 26.82/681.2 20.22/513.6 13.16/334.3

030040 27.43/696.7 197⁄8/504.8 221⁄4/565.4 26.57/674.9 20.05/509.3 13.16/334.3

030060/080 27.43/696.7 197⁄8/504.8 221⁄4/565.4 26.93/684.0 21.08/535.4 13.16/334.3

036060/080 27.43/696.7 197⁄8/504.8 221⁄4/565.4 27.31/693.7 20.97/532.6 13.16/334.3

036100/120 27.43/696.7 197⁄8/504.8 221⁄4/565.4 27.23/691.6 20.99/533.1 13.16/334.3

042060/080 31.43/798.3 237⁄8/606.4 261⁄4/666.8 26.87/682.5 20.99/533.1 14.96/380.0

042100/120 31.43/798.3 237⁄8/606.4 261⁄4/666.8 26.81/681.0 21.01/533.7 14.96/380.0

CHARACTERISTICS UNIT WEIGHT CORNER WEIGHT (lb/kg)

E F G X Y Z

(in./mm) CENTER OF GRAVITY

(in./mm) DIMENSION

HEIGHT

lation of air from outdoor fan discharge, with the exception

of the outdoor coil as stated. A removable fence or barri-

Overhangs 48 (1219.2)

Side 42 (1066.8)

Control Box Side 36 (914.4)

Control Box Side 42 (1066.8)

REQ’D CLEARANCES TO COMBUSTIBLE

REQ’D CLEARANCES FOR SERVICING

NEC (National Electrical Code) REQ’D

Unit and Block or Concrete Walls and

Unit and Ungrounded Surfaces,

CLEARANCES — in. (mm)

Between Units, Control Box

cade requires no clearance.

MAT’L — in. (mm)

Other Grounded Surfaces, · Maximum Extension of

Page 5 of the Carrier 48SS036 user manual — REQ’D CLEARANCES TO COMBUSTIBLE MAT’L
Pagina 5 · klik om te vergroten
Pagina 5
Carrier 48SS036 — REQ’D CLEARANCES TO COMBUSTIBLE diagram (page 5)
Afb. 2

048080 208/230-1-60 414 188 107/49 83/38 158/72 66/30 048100/120/140 208/230-1-60 426 193 110/50 86/39 159/72 71/32 060080 208/230-1-60 453 206 117/53 93/42 167/76 76/35 060100/120/140 208/230-1-60 465 211 120/55 96/44 167/76 82/37

048080 28.76/731 23.46/596 15.35/390 048100/120/140 28.42/722 23.42/595 15.35/390 060080 28.36/720 23.27/591 15.35/390 060100/120/140 27.95/710 23.23/590 15.35/390

Maximum Extension of Overhangs 48 (1219.2)

Between Units, Control Box Side 42 (1066.8)

Control Box Side 36 (914.4)

Grounded Surfaces, Control Box Side . . . 42 (1066.8)

REQ’D CLEARANCES FOR SERVICING — in. (mm)

NEC (National Electrical Code) REQ’D CLEARANCES

REQ’D CLEARANCES TO COMBUSTIBLE MAT’L

Unit and Block or Concrete Walls and Other

lation of air from outdoor fan discharge.

Unit and Ungrounded Surfaces,

Page 6 of the Carrier 48SS036 user manual — REQ’D CLEARANCES FOR SERVICING
Pagina 6 · klik om te vergroten
Pagina 6

Between Units, Control Box Side 42 (1066.8)

Unit and Ungrounded Surfaces, Control Box Side 36 (914.4)

Grounded Surfaces, Control Box Side 42 (1066.8)

048080 208/230-1-60, 208/230-3-60, 460-3-60, 575-3-60 438 199 113/51 89/40 164/75 72/33

048100/120/140 208/230-1-60, 208/230-3-60, 460-3-60, 575-3-60 450 205 116/53 92/42 165/75 77/35

060080 208/230-1-60, 208/230-3-60, 460-3-60, 575-3-60 477 217 123/56 99/45 173/79 82/37

060100/120/140 208/230-1-60, 208/230-3-60, 460-3-60, 575-3-60 489 222 126/57 102/46 173/79 88/40

048080 28.54/724.9 20.00/508.0 17.66/448 048100/120/140 28.22/716.8 20.05/509.3 17.66/448 060080 28.18/715.8 20.19/512.8 17.66/448 060100/120/140 27.79/705.9 20.23/513.8 17.66/448

WEIGHT CORNER WEIGHT

X Y Z

CENTER OF GRAVITY

NEC (National Electrical Code) REQ’D CLEARANCES — in. (mm)

CHARACTERISTICS

Unit and Block or Concrete Walls and Other

recirculation of air from outdoor fan discharge.

Overhangs 48 (1219.2)

REQ’D CLEARANCES FOR SERVICING

REQ’D CLEARANCES TO COMBUSTIBLE

MAT’L — in. (mm)

(lb/kg) · Maximum Extension of

Page 7 of the Carrier 48SS036 user manual — NOTES:
Pagina 7 · klik om te vergroten
Pagina 7
Carrier 48SS036 — CERTIFIED ROOF CURB DIMENSION PRINT diagram (page 7)
Afb. 3

CERTIFIED ROOF CURB DIMENSION PRINT

FLAT 8 [203] CPRFCURB002A00 11 [279] CPRFCURB003A00 14 [356]

1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied as required for unit being installed. 3. Dimensions in [ ] are in millimeters.
4. Roof curb is made of 16 gage steel. 5. Attach ductwork to curb (flanges of duct rest on curb). 6. Service clearance 4 ft on each side.
8. Insulated Panels: 1-in. thick fiberglass 1 lb density.
7. Direction of airflow.

NOTES:

Page 8 of the Carrier 48SS036 user manual — CERTIFIED ROOF CURB DIMENSION PRINT
Pagina 8 · klik om te vergroten
Pagina 8
Page 8 of the Carrier 48SS036 user manual — CERTIFIED ROOF CURB DIMENSION PRINT

Vraag stellen over de Carrier 48SS036

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Carrier 48SS036

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Carrier 48SS036 handleiding-pdf

8 pagina's·604 KB·Airconditioner·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…