Gebruiksaanwijzing /service van het product AS-8150 van de fabrikant Argox
Ga naar pagina of 123
NOTICE: This equipment has been tested and compli ed with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide a reasonable protection against ha rmful interface when the equipment is o perated under a commercial environment.
Using the ArgoxScan 81 10/8120 /8150/8250/83 10/8312 The ArgoxScan can automati cally scan bar code a t a distan ce. Simply aim and pull the trigger . Code scanning i s performed along the center of the light bar emit ted from the reading window . This bar mus t cover the entire code .
CONTENT S Chapter 1 Introduct ion Introduction…………… …………… ..………………. 1 Default Setting ………… ………… …………………. 2 ArgoxScan81 10 /8120 specification ……… ……….. 4 ArgoxScan815 0/8250/8310/8312 specifi cation ….
T elep en ………………… ………… ………………… . 80 S tanda rd 2 of 5 …… ………………………… ……… 82 China Post ……………… ………… ………………… 84 Italian phar m acode ………………………… ……… 86 Code 16K ………… ……………………….
.
1 Introduction Installation- Keyboard Wedge 1) First of all, you mus t switch of f pow er for the terminal/computer . 2) Disconnect the keybo ard cable fro m the back of the terminal/computer . 3) Connect the approp riate interface cable to the scanner and to the terminal/ computer .
2 Default setting For each bar code show n as below : Code T ype Read Enable Checksum V erification Enable Checksum T ransmission Enable Code ID 81 10 / 8120 UPC-A A UPC-E E EAN-13 F E.
3 Code T ype Read Enable Checksum V erification Enable Checksum T ransmission Enable Code ID 8150 8250 8310 8312 UPC-A A UPC-E E EAN-13 F EAN-8 FF Code-39 Interleaved 2 of 5 i Industrial 2 of 5 - - i .
4 Weight 155 g 120 g ArgoScan 81 10 / 8120 S pecificat ion Model 8 1 10 Model 8120 Operational Light Source 660 nm Vi sible Red LED Optical System 2048 pix el CCD (Charge- coupled device) Depth of Sca.
5 Cable – K/B w edge S traight 2.0 m Cable – universal type S traight 2.3 m Connector type RJ-45 phone jack conne ctor Case material ABS Cushion material Rubber Electrical Input V oltage 5 VDC ± 0.
6 Programming Programming method Manual (Rea ding special barcode) DOS command through RS-232 , Window s configuration progr am (81 10) Program upgrade Enabled built-in flash memory (81 10) Programmab.
7 ArgoScan 8150 / 8250 / 83 10 / 8312 S pecificat ion Model 8150/8250 Model 8310/8312 Operational Light Source 660 nm Vi sible Red LED 630 nm Vi sible Red LED Optical System 2048 pix el CCD (Charge- c.
8 Depth-head 35 mm 35 mm Weight 150 g (cable not included) 176 g (cable not included) Cable – K/B w edge S traight 2.0 m Coiled 2.5 m Cable – universal type S traight 2.
9 Operating T e mperature 0 to 45 (32 to 1 13 ) 0 to 45 (32 to 1 13 ) S torage -40 to 60 (-40 to 140 ) -20 to 60 (-4 to 140 ) Humidity 5% to 90 % relative hu midity , non-condensing Light Level Up to 60000 (8150); 80000 (8250) Lux. Up to 70000 Lux . Shock 1.
10 Programming the A rgoS can 81 10/8120/8150/8250/8310/8 312 T o pro gram the 81 10/8120 /8150/8250 /8310/8312, you mus t scan a series of pro gramming bar code in the correc t order . Fold out the back c over of thi s ma nual. Y ou w ill see a table of alphanumeric bar codes, which are used to progra m the various options presen ted.
11 Option Bar Code Option Al phanumeric Entry Interface selection Keyboard Wedge RS-232 Wand e mulation USB Keyboard/RS-23 2 Auto detection Reserved 00 01 02 03 04 05 Prog ram Exit Program Barcode Opt.
12 Exit Interface Selection This decoder built-in scanner comes in on e model and supports interfa ces such as keybo ard wedge, RS232 serial wedge , wand emulation, and the l atest USB interfa ce. In most of the cases, si mply selectin g an appropriate cable with a device code w ill work for a specific inter face.
13 Exit Keyboard wedge As a keyboard interfa ce, the scanne r supports most of the popular PCs and IBM ter minals. T he inst allation of the w edge is a fairly simple pro cess without any changes of sof tware or hardware . Keyboard T ype: Select keyboard ty pe connector of you r host computer .
14 Keyboard wedge Keyboard Lay out: The selecting of keyboar d layout supports many country language s other than U SA keyboard layout. First you need to confirm cou ntry language that you desire.
15 Exit Keyboard layou t USA Belgium Danish France Germany Italian Portuguese S pan ish Swedish Switzerland UK Latin American Japanese 00 01 02 03 04 05 06 07 08 09 10 1 1 12 Keyboard speed 0-8 0 : hi.
16 Keyboard wedge Cap s Lock: By select ing Caps lock”ON” or Caps lock”OFF” , scanner can get Cap s Lock s tatus. Power-on simulat ion: All of the P Cs check the keyb oard status durin g pow er-on selftest. It i s recommende d to Enable function if you are w orking without key board insta llation.
17 Exit Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OF F” 00 01 Power-o n simulation Disable Enable 00 01 Inter-character delay 00-99 msec 00-99 02 Block transm.
18 RS-232 CTS: Clear T o Send (Hardw are Signal) RTS: Request T o Send (Har dwar e Signal) Xon: T ransmit On (ASCII Code 1 1 16 ) Xoff: Tr ansmit Of f (ASCII Code13 16 ) Flow control : None- The communi cation only u ses Tx D and RxD signals without regard for any hardw are or softw are handshaking protocol.
19 Exit Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xof f ACK/NAK 00 01 02 03 Inter-character delay 00-99 (msec) 00-99 00 Block transmission delay 00-99 (10 msec) 00-99 00 .
20 Exit Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02 03 04 05 06 07 Parity None Odd Even 00 01 02 Data bit 8 bit.
21 Exit W a nd Emulation (for 81 10/8150/8250) Bar/sp ace polarity : High/low - Black w ill be transmitted as a high voltage level (+5) and space as low leve l (0V). Low/high - Black w ill be transmitte d as a low vo ltage level (0V) and spa ce as high level (+5) .
22 W a nd Emulation (for 81 10/8150/8250) Output speed: This setting is sa me as serial transmission baud rate, and it must be approbat ed your w and decode resolution. The unit of speed is a w idth of minimu m narrow bar . Margin delay : It is a timer of zone like sp ace zone of barcode label marg in.
23 Exit Option Bar Code Option Alphanumeric Entry Output speed 620 pps 1250 pps 2500 pps 5000 pps 10000 pp s 20000 pp s *pps: pix el per second 00 01 02 03 04 05 Reserved 00 Reserved 00 Margin delay 0.
24 Pin A s signments A S Series 8-pin RJ-45 Connecto r Pin RS-232 Keyboard 1 V CC (+5V) VCC (+5V) 2 TXD NC 3 NC CLK / PC 4 NA DA T A / PC 5 CTS DA T A / KB 6 RXD NC 7 RTS CLK / KB 8 GND GND 8-pin 10-p.
25 Keyboard Wedge Combo Con nec tor (T o Host Side): Pin M ini-DIN 6P Male DIN 5P Fe male 1 DA T A / PC DA T A / KB 2 NC NC 3 GND GND 4 V CC (+5V) VCC (+5V) 5 CLK / PC CLK / KB 6 NC NC RS-232 DB-9F Co.
26 Keyboard Wedge PS/2 Con nector (T o Host Side): Pin Mini-DIN 6 P Male Mini-DIN 6P Female 1 DA T A / PC DA T A / KB 2 NC NC 3 GND GND 4 VCC (+5V) VCC (+5V) 5 CLK / PC CLK / KB 6 NC NC 3 1 2 4 5 3 4 .
27.
28 Scan Scanning mode: Good-read off- Th e trigger button mus t be pressed to activate scanning. The light source of s canner stops scanning wh en there is a successf ul reading or no code is decoded after the S tand-b y duration elapsed. Moment ary- The trigger button act s as a sw itch.
29 Exit Option Bar Code Option Alphanumeric Entry Scanning mode Good-read of f Momentary Alternate Ti meout of f Continue T est only 00 01 02 03 04 05 S tand- by duration 01-99 (second) 00-99 06 Doubl.
30 Scan Global min./max . code length : These are to de fine the min/ max readable code le ngth of all symbolog ies. Code leng th less than min. code length or m ore than max. code length will not be read. In popular , you can set the same value for both min.
31 Exit Option Bar Code Option Alphanumeric Entry Global min. code leng th 00-99 (00-64) 00-99 (AS-8120) 04 Global max. code leng th 00-99 (00-64) 04-99 99 (AS-8120 , 64 ) Inverted image scan Disable .
32 Scan Position indicatio n (81 10 excluded): If the function is enabled, scan bea m will flash as a pointer to help you ai m at the bar code prior to scanning. Th e code will no t be scanned until you press the trigg er . St and mode selection: Nor mally activated with continuous mode.
33 Exit Option Bar Code Option Alphanumeric Entry Position indication Disable 30 second 60 second 90 second 120 second 150 second 180 second Continue 00 01 02 03 04 05 06 07 *7AL* S tand mode selectio.
34 Indication Power on alert: Af ter powe r-on the scanner it w ill generate an alert signal to indi cate a succes sful self-test. LED indication: After ea ch successful reading, the LED above the scanner w ill light up to ind icate a good barcode reading.
35 E xit Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01 LED indication Disable Enable 00 01 Beeper indication Disable Enable 00 01 Beep loudness 00-07 00-07 07 Beep tone freq.
36 UPCA Format Leading Zero Data Digit s (1 1 Digits) Check Digit Read: Enable or disable the read f unction. Check-sum trans mission: By set ting Enable , checks su m will be transmitted. T runcate leading/ending: The le ading or ending digits of barcode dat a characters can b e trun cated wh en these value s are set to non-z ero.
37 Exit Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check-sum transmis sion Disable Enable 00 01 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting .
38 UPCA Insertion grou p number se lection: The s canner of fers max. two insertion group s for one symbology . By setting one or two digits to indi cate which insertion group you want to insert. Y ou may refer to Character insert ion. Th e function is to insert specific characters a s a group into trans mitted data of selected symbologie s.
39 Exit Option Bar Code Option Alphanumeric Entry Insert group nu mber selection 00-44 00-44 00 Supplement digit s (For 81 10/8150/8250) None 2 digits 5 digits UCC/EAN 128 Auto detection 00 01 02 03 0.
40 UPCA T runcation / Expans ion: The lea ding “0” digit s of UPCA data chara cters can be truncated w hen the function is enabled..
41 Exit Option Bar Code Option Alphanumeric Entry Tr uncation/ Exp ansion (For 81 10) Disable Enable 00 01 Tr uncation/ Exp ansion (For 8120/8150/8250/ 8310/8312) None Tr uncate leading zero Exp and t.
42 UPCE Read: Format Leading Zero Data Digit s (6 Digits) Check Digits Check-sum trans mission: By set ting Enable , checks su m will be transmitted. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA.
43 Exit Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < E >.
44 UPCE Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A. Supplement digit s: Format Leading Zero Data Digit s (6 Digits) Check Digit Supplement Digit s 2 or 5 or UCC/EAN 128 Expans ion: The ex p ansion function is used only for UPCE and EAN- 8 code reading.
45 Exit Supplement digit s (For 8120/8310/831 2) None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 00 01 02 03 04 05 06 07 Tr uncation/Exp ans ion (For 81 10) Disable Ena.
46 EAN-13 Read: Format Data Digit s (12 Digit s ) Check Digit s Check-sum trans mission: By set ting Enable , checks su m will be transmitted. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. T runcate leading zero: Refer to T runcation / Exp ansion of UPCA.
47 Exit Tr uncate ending 0-15 00-15 00 Tr uncation leading zero Disable Enable 00 01.
48 EAN-13 Code ID setting : Refer to pa ge 36 Insertion gr oup number selection of UPCA. Insertion gro up numbe r selection: R efer to I nsertion gr oup selection of UPCA.
49 Exit Supplement digit s (For 81 10/8150/8250) None 2 digits 5 digits UCC/EAN 128 Auto detection 00 01 02 03 04 Supplement digit s (For 8120/8310/831 2) None 2 digits 5 digits 2,5 digits UCC/EAN 128.
50 EAN-8 Read: Format Data Digit s (7 Digits) Check Digits Check-sum trans mission: By set ting Enable , checks su m will be transmitted. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA.
51 Exit Tr uncate ending 0-15 00-15 00 Code ID setting T wo characters 00-ffH ASCII code 00-ffH, 00- ffH < FF > Insert group nu mber selection 00-44 00-44 00.
52 EAN-8 Supplement digit s: Format Data Digit s (7 Digits) Check Digits Supplement Digit s 2 or 5 or UCC/EAN 128 T runcation / Expans ion: Refer to T run cate Leading zer o of UPCE.
53 Exit Tr uncation / Exp ansion (For 81 10) Disable Enable 00 01 Tr uncation / Exp ansion (For 8120/8150/825 0 /8310/8312) None Tr uncate leading zero Exp and to E AN13 00 01 02 Exp ansion Disable En.
54 Code 39 Read: Format S tart “ ” Data Digit s ( V ariable) Checksum (Optional) End “ ” Check-sum verificat ion: The che cksum of Code- 39 is optional and made as the sum mo dule 43 of the nu merical value of the data digit s. Check-sum trans mission: By set ting Enable , checksu m will be transmitted.
55 Exit Check-sum verification Disable Enable 00 01 Check-sum transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Tr uncate leading 0-20 00-20 00 Tr uncat.
56 Code 39 Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A. Format: The Full ASCII Code-39 i s an enhanced set of Code-39 that is the dat a w ith total o f 128 characters to represent Full ASCII code. It is co mbined one of the digits +, %, $ and/ with one of the alpha dig its (A to Z).
57 Exit Format S tanda rd Full ASCII 00 01 Append Disable Enable 00 01 S tart /end transmission Disable Enable 00 01.
58 Interleaved 2 of 5 Read: Format Data Digit s (V ariable) Checksum (Optional) Check-sum ver ification: The checksum is made a s the su m module 10 of the nu merical value s of all data digits . Check-sum trans mission: By set ting Enable , checksu m will be transmitted.
59 Exit Check-sum transmission Disable Enable 00 01 Max. code leading 00-64 00-64 00 Min. code leading 00-64 00-64 00 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-.
60 Industrial 2 of 5 Read: Format Data Digit s (V ariable) Checksum (Optional) Max./Min. code length : Refer to Max./Min. code len gth of Code-39. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA.
61 Exit Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < i > Insert group nu mber selection 00-44 00-44 00.
62 Matrix 2 of 5 Eur Read: Format Data Digit s (V ariable) Checksum (Optional) Checksum V erification: The che cksum is made as the sum module 10 of the nu merical value s of all data digits . Checksum T ransmission: By set ting Enable , che cksum w ill be transmitted.
63 Exit Checksum Tr ansmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ff.
64 Codabar Read: Format Checksum V erification: The che cksum is made as the sum module 16 of the nu merical value s of all data digits . Checksum T ransmission: By set ting Enable , che cksum w ill be transmitted. Max./Min. code length : Refer to Max.
65 Exit Checksum Tr ansmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ff.
66 Exit Codabar Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A. St art/End ty pe: The Codabar has four pairs of S tart/End pattern; you may select one p air to match your applicat ion. St art/End T ransmission: Refer to S tart/End Transmission of Code 39.
67 Exit Code-128 Read: Format Data Digit s (V ariable) Checksum (Optional) Checksum V erification: The che cksum is made as the sum module 103 of all dat a digit s.
68 Code-128 Max./Min. code length : Refer to Max./Min. code len gth of Code-39. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA. Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A.
69 Exit Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < # > Insert group nu mber selection 00-44 00-44 00 Format S tanda rd UCC/EAN-128 .
70 Exit Code-128 A ppend: When the function is enab led, it won' t show the data immediately if scanner rea d the barcode in cludes FNC2 code. It will show all data until i t read the barcode , which doesn' t have FNC2 code. UCC/ EA N 128 ID setting: T o set ting the code ID for UCC/EAN-128 outpu t format.
71 Exit Code-93 Read: Format Data Digit s (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The che cksum is made as the sum module 47 of the nu merical value s of all data digits . Checksum T ransmission: By set ting Enable , checksu m will be transmitted.
72 Code-93 Max./Min. code length : Refer to Max./Min. code len gth of Code-39. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA. Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A.
73 Exit Code ID setting 00-ffH ASCII code 00-ffH < & > Insert group nu mber selection 00-44 00-44 00.
74 Code-1 1 Read: Format Data Digit s (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The che cksum is presen ted as the sum module 1 1 of all data digi ts. Checksum T ransmission: By set ting Enable , checksu m1 and checksum2 w ill be transmitted upon your selected checksum verification method.
75 Exit Checksum Tr ansmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ff.
76 MSI/plesse y Read: Format Data Digit s (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The M SI/Plessey has one or two optional checksum d igit s. The checksum is p resented 3 kinds of method Mod10 , Mod10/10 and Mod 1 1/10 .
77 Exit Mod 1 1/10 03 Checksum Tr ansmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID.
78 UK/plessey Read: Format Data Digit s (V ariable) Checksum1+2 (Optional) Checksum V erification: The UK /Plessey ha s one or two optional checksum dig its. The che cksum1 and chec ksum2 will be calculated as the sum modu le 10 or 1 1 of the data digits.
79 Exit Checksum Tr ansmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ff.
80 T elepen Read: IA T A (In ternational Air Tra nsport Association). Checksum V erification: The che cksum is presen ted as the sum module 10 or 1 1 of the data d igits. Checksum T ransmission: By set ting Enable , che cksum w ill be transmitted. Max.
81 Exit Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < S > Insert group.
82 St andard 2 of 5 Read: Format Data Digit s (V ariable) Checksum1 (Optional) Check-sum ver ification: The checksum is made a s the su m module 10 of the nu merical value s of all data digits . Check-sum trans mission: By set ting Enable , checksu m will be transmitted.
83 Exit *JAC* Check-sum transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting.
84 China Post Read: Format Data Digit s (V ariable) Checksum1 (Optional) Max./Min. code length : Refer to Max./Min. code len gth of Code-39. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA.
85 Exit Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < t > Insert group nu mber selection 00-44 00-44 00.
86 It alian Pharmacode (Code 32) Read: Format Data Digit s (V ariable) Checksum1 (Optional) Max./Min. code length : Refer to Max./Min. code len gth of Code-39. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA.
87 Exit Min. code length 00-64 00-64 09 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 01-ffH < p > Insert group nu mber selection 00-44 00-44 0.
88 Code-16K (for 8250/8312 ) T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA. Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A.
89 Exit Insert group nu mber selection 00-44 00-44 00.
90 PDF-417 (for 8250/8312) T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA. Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A.
91 Exit Option Bar Code Option A lphanumeric Entry Read Disable Enable 00 01 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < > Insert gr.
92 EAN UCC Composite (for 8312 ) For the coupon ex tended code ap plication. Coupon ex tended code is a supplementary barcode th at is pr inted to the right of the UPC/EAN in UCC /EAN-128 sy mbology . Option Bar Code Option A lphanumeric Entry *YAA* Read Disable Enable 00 01 *YAD* Max.
93 Exit *YAH* Code ID setting 00-ffH ASCII code 00-ffH < RC > * YAI* Insert group nu mber selection 00-44 00-44 00 * Y AK* UCC / EAN128 emulation Disable Enable 00 01.
94 RSS-14 Read: Format Data Digit s (V ariable) Checksum1 (Optional) T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA. Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A.
95 Exit Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < R4 > Insert group nu mber selection 00-44 00-44 00 UCC/EAN128 emulation Disable .
96 RSS-Limited Read: Format Data Digit s (V ariable) Checksum1 (Optional) T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA. Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A.
97 Exit Code ID setting 00-ffH ASCII code 00-ffH < RL > Insert group nu mber selection 00-44 00-44 00 UCC/EAN128 emulation Disable Enable 00 01.
98 RSS-Expanded Read: Format Data Digit s (V ariable) Checksum1 (Optional) Max./Min. code length : Refer to Max./Min. code len gth of Code-39. T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA.
99 Exit Min. code length 00-99 00-99 01 Tr uncate leading 0-15 00-15 00 Tr uncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < RX > Insert group nu mber selection 00-44 00-44 .
100 Micro-PDF (for 8312) T runcate leading/ending: Re fer to T runcate leading/ending of UPCA. Code ID setting : Refer to Code ID setting of UPCA. Insertion group number selectio n: Refer to pa ge 36 Insertion group nu mber selection of UPC A.
101 Exit * XAI* Insert group nu mber selection 00-44 00-44 00 * X AJ * Escape sequence transmit None GLI protocol ECI protocol 00 01 02.
102 String setting / T ransmissi on (Prefix / Suffix) Prefix / Suffix chara cters setting : Characters defined a s prefix or suf fix c haracters will be tr ansmitted immediately w ith the scanned data for all sy mbologies. Up to 22 ASCII characters can be defined as Prefix or Suffix.
103 Exit Option Bar Code Option A lphanumeric Entry Prefix characters setting None 1-22 characters 00 00-ffH ASCII code Suffix characters setting None 1-22 characters 0D 00-ffH ASCII code Program.
104 String setting / T ransmissi on (Preamble/Postamble ) Preamble/ Post amble characters: Prea mble or Posta mble characters will be append ed to the dat a automatically for all symbologies. How ever , the transmission will not ac tivate unless Preamble / Post amble trans mission is enabled.
105 Exit Option Bar Code Option A lphanumeric Entry Preamble character s setting None 1-22 characters 00 00-ffH ASCII code Preamble transmission Disable Enable 00 01 Posta mble characters setting None.
106 String setting / T ransmissi on (Insert Group Characters) Insert G1/G2/G3 /G4 character se tting: The scanner supports inser ting two groups w ith each group 22 chara cters into transmitted dat a of sele cted symbologie s. The two group s can be inserted into scanned data of the selected symbologies or po sitioned at leadi ng / ending of da ta.
107 Exit 5) Repeat the same pr ocedure in Insert G2 character s setting . 6) Scan Exit barcode. 6) Insert data group 1-4 position. Please refer to Chapter - Tr ansmission, page 65 and in specific bar code tha t you want to use. 7) Insert dat a group 1-4 position: Th e scanner of fers 4 positions to insert a mong the sy mbol.
108 String setting / T ransmissi on (Insert Group Characters) Insert G3 character s setting None 1-22 characters 00 00-ffH ASCII code Insert G4 character s setting None 1-22 characters 00 00-ffH ASCII.
109 Exit Insert data group 4 position 00-63 (00: no insertion) 00-63 00.
110 String setting / T ransmissi on (Others) Code ID position: Upon your usa ge, the transmitting position of Code ID can be selected to pla ce Before Code Data or After Code Dat a when it is transmitted. Code ID transmissio n: If your ap plication is needed to transmit Code ID, yo u must set thi s to Propriet ary ID or A IM ID.
1 1 1 Exit Code ID position Before code data After code data 00 01 Code ID transmission Disable Proprietary ID AIM ID 00 01 02 Code length transmission Disable Enable 00 01 Code name transmission Disa.
112 CODABAR-P ARA (8 1 10 *) .
113 PDF-417 (8250/8 312 *) ST ANDRAD-25 P ARA CODE-16K EAN-8 P ARA * INDUSTRIAL-25 P ARA UPCE P ARA *.
114 INTERLEA VED-25 P ARA * MA T RIX 25 P ARA MSI/PLESSEY P ARA UPCA P ARA * UK/PLESSEY P ARA RSS Micro-PD F (8312 *).
115 ASCII Code T able.
116 Parameter Setting List Program Barcode st andard p arameter setting list If you wish to display the current c onfiguration of you r AS-81 10/8120/8150/8250/831 0/8312, scanner over the hos t terminal/computer , sc an the Barco de standard p ara meter setting list bar code.
117 Exit Query present scanner fir mware v ersion Program Firmware version list If you wish to display the firmwa re version, scan the “Firmware ve rsion list” barcod e.
118 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D.
Een belangrijk punt na aankoop van elk apparaat Argox AS-8150 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Argox AS-8150 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Argox AS-8150 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Argox AS-8150 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Argox AS-8150 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Argox AS-8150 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Argox AS-8150 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Argox AS-8150 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.