2200 RA TED W A TTS/2400 MAX W A TTS PORT ABLE GENERA T OR 98452 OPERA TING INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL.
Page 2 SKU 98452 For technical questions, please call 1-800-444-3353. SPECIFICA TIONS V AC Electrical Specications 1 15 V olts @ 20 Amps Current Output 60 Hz 2200 Rated W atts / 2400 Max Watts T wo.
Page 3 SKU 98452 For technical questions, please call 1-800-444-3353. UNP ACKING Whe n unp ack ing, che ck to make sur e all the parts show n on the Part s LIs ts on pages 20 and 22 are included. If any parts are missing or broken, please call Harbor Freight T ools at the number shown on the cover of the manual as soon as possible.
Page 4 SKU 98452 For technical questions, please call 1-800-444-3353. Do not abuse the Power Cords. Never use a Power Cord to carry tools or pull 8. the Plug from the outlet. Keep Power Cords away from heat, oil, sharp edges, or moving parts. Replace damaged Power Cords immediately .
Page 5 SKU 98452 For technical questions, please call 1-800-444-3353. the generator . Such preventive safety measures reduce the risk of starting the generator accidentally . Store idle generators out of reach of children and other untrained persons. 19.
Page 6 SKU 98452 For technical questions, please call 1-800-444-3353. Maintain labels and nameplates on the Generator and Engine. 25. These carry important information. If unreadable, or missing, contact Harbor Freight T ools for a replacement. Generator service must be performed only by qualied repair personnel.
Page 7 SKU 98452 For technical questions, please call 1-800-444-3353. SPECIFIC SAFETY RULES AND PRECAUTIONS HEART P ACEMAKER PRECAUTION W ARNING! People with pacemakers should consult their physician(s ) before using this product.
Page 8 SKU 98452 For technical questions, please call 1-800-444-3353. Install sound and weather proong only when it is not raining or snowing to 1 1. avoid trapping moisture with the Generator ’ s area. FIRE AND EXPLOSION PRECAUTIONS Gasoline fuel and fumes are ammable, and potentially explosive.
Page 9 SKU 98452 For technical questions, please call 1-800-444-3353. MECHANICAL PRECAUTIONS AL W A YS 1. make sure the Power Switch is in its “OFF” position. Disconnect the spark plug wire, and allow the Engine to completely cool before carrying our maintenance.
Page 10 SKU 98452 For technical questions, please call 1-800-444-3353. NOISE PRECAUTION Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the Generator when it is running.
Page 1 1 SKU 98452 For technical questions, please call 1-800-444-3353. Keep all electrical equipment clean and dry . 8. Replace any wiring where the in- sulation is cracked, cut, abraded, or otherwise degraded. Replace terminals that are worn, discolored, or corroded.
Page 12 SKU 98452 For technical questions, please call 1-800-444-3353. GENERA TOR SUPPORT AND MOUNTING Mount the Generator on a concrete slab capable of supporting the weight of the Gen- erator . The slab must extend on all sides beyond the Frame (41B) by a least one foot.
Page 13 SKU 98452 For technical questions, please call 1-800-444-3353. AC Applications Before connecting an appliance or power cord to the generator: Make sure that it 1. is in good working order . Faulty appliances or power cords can create a potential for electrical shock.
Page 14 SKU 98452 For technical questions, please call 1-800-444-3353. REV 09h THIS GENERA TOR HAS AN AUT O- SHUTDOWN OIL SENSOR. IF ENGINE STOPS OR WILL NOT ST ART , CHECK OIL LEVEL.
Page 15 SKU 98452 For technical questions, please call 1-800-444-3353. Before the rst use, remove the Fuel T ank Cap (33B 3. 1 ) and ll the Fuel T ank (30B 1 ) with unleaded gasoline. Then, replace the Fuel T ank Cap. If necessary , rell the Fuel T ank with unleaded gasoline.
Page 16 SKU 98452 For technical questions, please call 1-800-444-3353. T urn the Engine Power Switch (2) to its “ON” position. 5. (See Figure F .) Hold the Start Handle (41A) loosely and pull it slowing several times to allow the 6. gasoline to ow into the Engine’s carburetor .
Page 17 SKU 98452 For technical questions, please call 1-800-444-3353. Powering 120 V olt AC T ools and Equipment: Prior to powering tools and equipment, make sure the Generator ’ s rated voltage, 1. and amperage capacity (1 15 V AC / 20 AMPs) is adequate to supply all electrical loads that the unit will power .
Page 18 SKU 98452 For technical questions, please call 1-800-444-3353. When nished using the Generator , turn the Engine Power Switch (2) to its 5. “OFF” position. T urn the Fuel V alve (40B) to its “OFF” position. Then, disconnect the electrical powered tool or equipment from the Generator ’s DC T erminals (7).
Page 19 SKU 98452 For technical questions, please call 1-800-444-3353. REV 09a INSPECTION, MAINTENANCE, AND CLEANING CAUTION! Always make sure the Engine Power Switch (2) is in its “OFF” position.
Page 20 SKU 98452 For technical questions, please call 1-800-444-3353. P ARTS LIST Part Description Qty 1 Bolt (M6 x 12) w/Lock W asher 9 2 Engine Power Switch 1 3B Control Panel 1 4 V oltmeter 1 5 Ci.
Page 21 SKU 98452 For technical questions, please call 1-800-444-3353. ASSEMBL Y DIAGRAM.
Page 22 SKU 98452 For technical questions, please call 1-800-444-3353. P ARTS LIST - CONTINUED Part Description Qty 1A Mufer 1 2A Cylinder Head Bolt 4 3A Cylinder Head Cover Bolt 4 4A Cylinder Head.
Page 23 SKU 98452 For technical questions, please call 1-800-444-3353. ASSEMBL Y DIAGRAM NOTE: Some parts are listed and shown for illustration purposes only , and are not available individually as replacement parts.
Page 24 SKU 98452 For technical questions, please call 1-800-444-3353. California and United States Emission Control Defects W arranty Statement The California Air Resources Board (herein CARB), the U.
Page 25 SKU 98452 For technical questions, please call 1-800-444-3353. 1. Length of Coverage HFT warrants to a rst retail purchaser and each sub - sequent purchaser that the engine is free from def.
Een belangrijk punt na aankoop van elk apparaat Chicago Electric 98452 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Chicago Electric 98452 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Chicago Electric 98452 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Chicago Electric 98452 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Chicago Electric 98452 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Chicago Electric 98452 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Chicago Electric 98452 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Chicago Electric 98452 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.