Gebruiksaanwijzing /service van het product UCSCPCIECSC02 van de fabrikant Cisco Systems
Ga naar pagina of 40
Managing Network Adapters This chapter includes the following sections: • Overview of the Cisco UCS C-Series Network Adapters, page 1 • V iewing Network Adapter Properties, page 2 • Configuring .
Cisco UCS P81E Virtual Interface Card The Cisco UCS P81E V irtual Interface Card is optimized for virtualized environments, for or ganizations that seek increased mobility in their physical environments, and for data centers that want reduced costs through NIC, HBA, cabling, and switch reduction and reduced management overhead.
Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab. Step 4 In the Adapter Cards area, click an adapter in the table to display its properties.
Description Name If this field displays yes , the adapter configuration has changed in CIMC but these changes have not been communicated to the host operating system. T o activate the changes, an administrator must reboot the adapter . Configuration Pending field The user-defined description for the adapter , if any .
Description Name The firmware version that is currently active. Running V ersion field The alternate firmware version installed on the adapter , if any . The backup version is not currently running. T o activate it, administrators can click Activate Firmware in the Actions area.
Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab.
Managing vHBAs Guidelines for Managing vHBAs When managing vHBAs, consider the following guidelines and restrictions: • The Cisco UCS P81E V irtual Interface Card and Cisco UCS VIC1225 V irtual Interface Card provide two vHBAs (fc0 and fc1). Y ou can create up to 16 additional vHBAs on these adapter cards.
Description Name The WWPN associated with the vHBA. T o let the system generate the WWPN, select AUTO . T o specify a WWPN, click the second radio button and enter the WWPN in the corresponding field. W orld Wide Port Name field If checked, the vHBA can be used to perform a SAN boot.
Description Name The resource allocation timeout value (RA T OV), which is the number of milliseconds to wait before the system assumes that a resource cannot be properly allocated. Enter an integer between 5,000 and 100,000. The default is 10,000 milliseconds.
Description Name The preferred driver interrupt mode. This can be one of the following: • MSIx —Message Signaled Interrupts (MSI) with the optional extension.
Description Name The number of milliseconds that the system waits before it tries to log in again. Enter an integer between 1,000 and 255,000. PLOGI Timeout field Step 14 In the SCSI I/O area, review the information in the following fields: Description Name The number of SCSI I/O queue resources the system should allocate.
Step 5 In the tabbed menu below the Adapter Cards area, click the vHBAs tab. Step 6 In the Host Fibre Channel Interfaces area, select a vHBA from the table. Step 7 Click Properties to open the vHBA Pr operties dialog box. Step 8 In the General area, update the following fields: Description Name The name of the virtual HBA.
Description Name The data rate limit for traffic on this vHBA, in Mbps. If you want this vHBA to have an unlimited data rate, select OFF . Otherwise, click the second radio button and enter an integer between 1 and 10,000. This option cannot be used in NIV mode.
Description Name The number of milliseconds the uplink port should be offline before it informs the system that the uplink port is down and fabric connectivity has been lost.
Description Name The number of times that the system tries to log in to the fabric after the first failure. T o specify an unlimited number of retries, select the INFINITE radio button. Otherwise select the second radio button and enter an integer into the corresponding field.
Step 16 Click Save Changes . Creating a vHBA The adapter provides two permanent vHBAs. If NIV mode is enabled, you can create up to 16 additional vHBAs. Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory .
Deleting a vHBA Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab.
Description Name The W orld W ide Port Name (WWPN) that corresponds to the location of the boot image. Enter the WWPN in the format hh:hh:hh:hh:hh:hh:hh:hh. T arget WWPN field The LUN ID that corresponds to the location of the boot image. Enter an ID between 0 and 255.
V iewing Persistent Bindings Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab. Step 4 In the Adapter Cards area, select the adapter card.
Rebuilding Persistent Bindings Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab. Step 4 In the Adapter Cards area, select the adapter card.
V iewing vNIC Properties Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab. Step 4 In the Adapter Cards area, select the adapter card.
Description Name If there is no default VLAN for this vNIC, click NONE . Otherwise, click the second radio button and enter a VLAN ID between 1 and 4094 in the field. This option cannot be used in NIV mode. Note Default VLAN field If you want to use VLAN trunking, select TRUNK .
Description Name The number of interrupt resources to allocate. In general, this value should be equal to the number of completion queue resources. Enter an integer between 1 and 514. Interrupt Count field The time to wait between interrupts or the idle period that must be encountered before an interrupt is sent.
Description Name The number of descriptors in each transmit queue. Enter an integer between 64 and 4096. T ransmit Queue Ring Size field Step 12 In the Completion Queue area, review the information in the following fields: Description Name The number of completion queue resources to allocate.
Description Name Receive Side Scaling (RSS) distributes network receive processing across multiple CPUs in multiprocessor systems. If checked, network receive processing is shared across processors whenever possible. If cleared, network receive processing is always handled by a single processor even if additional processors are available.
Description Name The name for the virtual NIC. This name cannot be changed after the vNIC has been created. Name field The maximum transmission unit, or packet size, that this vNIC accepts. Enter an integer between 1500 and 9000. MTU field The uplink port associated with this vNIC.
Description Name Select the channel number that will be assigned to this vNIC. NIV mode is required for this option. Note Channel Number field Select the port profile that should be associated with the vNIC. This field displays the port profiles defined on the switch to which this server is connected.
Description Name The preferred driver interrupt mode. This can be one of the following: • MSI-X —Message Signaled Interrupts (MSI) with the optional extension.
Description Name If checked, the CPU sends large TCP packets to the hardware to be segmented. This option may reduce CPU overhead and increase throughput rate. If cleared, the CPU segments large packets. This option is also known as Large Send Of fload (LSO).
Step 15 Click Save Changes . Creating a vNIC The adapter provides two permanent vNICs. Y ou can create up to 16 additional vNICs. Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab.
Deleting a vNIC Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab.
If the server is powered on, the resources of the selected adapter card appear in the tabbed menu below the Adapter Cards area. Step 5 In the tabbed menu below the Adapter Cards area, click the VM FEXs tab.
Step 10 In the Ethernet Interrupt area, review the information in the following fields: Description Name The number of interrupt resources allocated to this VM FEX. Interrupt Count field The time CIMC waits between interrupts or the idle period that must be encountered before an interrupt is sent.
Description Name The number of descriptors in each completion queue. Completion Queue Ring Size field Step 14 In the TCP Offload area, review the information in the following fields: Description Name If enabled, the CPU sends large TCP packets to the hardware to be segmented.
Backing Up and Restoring the Adapter Configuration Exporting the Adapter Configuration The adapter configuration can be exported as an XML file to a TFTP server . Before Y ou Begin Obtain the TFTP server IP address. Procedure Step 1 In the Navigation pane, click the Server tab.
Importing the Adapter Configuration Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab. Step 4 In the Adapter Cards area, select the adapter card.
Step 5 In the tabbed menu below the Adapter Cards area, click the General tab. Step 6 In the Actions area of the General tab, click Reset T o Defaults and click OK to confirm.
Installing Adapter Firmware From a TFTP Server Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab. Step 4 In the Adapter Cards area, select the adapter card.
Activating Adapter Firmware Procedure Step 1 In the Navigation pane, click the Server tab. Step 2 On the Server tab, click Inventory . Step 3 In the Inventory pane, click the Network Adapters tab. Step 4 In the Adapter Cards area, select the adapter card.
Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide, Release 1.4 40 OL-23489-08 Managing Network Adapters Resetting the Adapter.
Een belangrijk punt na aankoop van elk apparaat Cisco Systems UCSCPCIECSC02 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Cisco Systems UCSCPCIECSC02 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Cisco Systems UCSCPCIECSC02 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Cisco Systems UCSCPCIECSC02 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Cisco Systems UCSCPCIECSC02 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Cisco Systems UCSCPCIECSC02 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Cisco Systems UCSCPCIECSC02 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Cisco Systems UCSCPCIECSC02 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.