Gebruiksaanwijzing /service van het product 87392-11 van de fabrikant Clarity
Ga naar pagina of 53
C C l l a a r r i i t t y y U U s s e e r r G G u u i i d d e e March 1, 2011 Part 87392-11, Rev. 1.06.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 Warnings, Cautions and Notes as used in this Guide WARNING This publication uses Warning notices to emphasize situations in which hazardous voltages, temperatures, or other conditions associated with the use of this equipment could cause personal injury or serious damage to the equipment.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 TABLE OF CONTENTS Page Chapter 1 - Getting Started .................................................................................................... ......... 5 Unpacking the Clarity ............
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 Key Features of the Advanced Screen .................................................................................. 27 Home .......................................................................
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 5 Chapter 1 – Getting Started The Clarity Automated Lens Analyzer/Blocker is designed to verify all prescription parameters including sphere pow er, cylinder power, axis, optic al center location, prism, and all add powers as well as thickness and front curv e information.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 6 9. Main fuse (located on rear bulkhead) 10. Glass plate (See Fig. 1.5) Remove and inst all in the blocking chamber as described later in this chapter. 11. Light shield (blocking arm) 12. Light shield (left gripper) 13.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 7 Figure 1.1b – Block #2 (P/N 33592 - Rear Shipping Block) Shipping Bracket Used in the Blocking Chamber: Figure 1.1c – Shipping Bracket Assembly, Clarity (P/N 33648 ) The Shipping Bracket assembly is shown in Figure 1.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 8 Figure 1.1d – Installed Shipping Bracket Assembly Plate Pinch Rod Pinch Lock Foot.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 9 Figure 1.2 – Clarity Front View - User Items Display Frame Display Tilt Handle Touch Screen Display Block Arm (Extended or Retracted) Lens Table .
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 0 Figure 1.3 - Clarity Rear Connector Bulkhead Figure 1.4 – Accessory Kit 1. Power supply 8. Oval calibration template with permanent block attached 2. Power cord 9. Fuse (in the bag of screws) 3.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 1 Figure 1.5 – Installing the Glass Plate Installing the Glass Plate – The glass plate is placed over the opening in the base pl ate of the blocking chamber. Clean the glass plate and then slide it into the pocke t.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 2 (This page intentionally left blank for duplexing purposes.).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 3 Chapter 2 – Basic Operation WARNING Use only a grounded outlet. Do not de feat the grounding by cutting off the grounding prong on the power cord, or by using a non-grounding adapter. NOTE The power supply module is designed to work with both 115 VAC (60 Hz) and with 230 VAC (50 Hz).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 4 connection. If you are using an Ethernet connection, then you must set the two ports in the TCP/IP Network Auto-Connect Settings box. CAUTION Keep hands away from unit during the blocking function.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 5 When a Job Number has been entered, the EXIT label on the contro l button changes to PROCESS . Jobs are processed in one of the following three ways: 1. You may enter the job number m anually with the touch screen keypad or keyboard and then select PROCESS.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 6 As instructed by the screen prompts, load a bloc k and pad onto the blocking arm chuck and place the lens to be blocked on the glass plate in the blocking chamber.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 7 After the lens has been analyzed, the bottom of the screen will display eight buttons and five arrows. (See Fig. 2.3.) The eight buttons are: 1. Turn Off – Exit the program and shut the power off.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 8 Figure 2.4 – The Teach Screen At the lower left of the screen, there may app ear one or more im ages that the Clarity has identified as candidates for the fitting cross.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 1 9 The image should be saved in the Clarity database. Im ages in the database are listed in the upper-right of the Teach screen. Each image ha s a unique nam e that may be derived from the lens type name, or entered via a keyboard.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 0 (This page intentionally left blank for duplexing purposes.).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 1 Chapter 3 – Setup Screens Figure 3.1 – Main Menu Screen The Setup screens are accessed by pressing the Setu p button at the lower left of the Main Menu screen . (See figure 3.1.) Specific setup functi ons are selected by using the tabs across the top of the Setup screen.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 2 The Preferences Screen Figure 3.2 - Preferences Screen Key Features of the Preferences Screen Batch Blocking: If enabled, the user may enter a series of job num bers. As each job completes, the next job is automatically starte d.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 3 Tolerances Screen Figure 3.3 – Tolerances Screen The values on this screen indicate how closely a measured lens characteristic must m atch the Rx in order for the verification to pass. The values are preset prior to shipm ent to ANSI standards.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 4 The Interface Screen Figure 3.4 – Interface Screen Key Features of the Interface Screen - This screen allows you to set the serial communication baud rate for the port used. It also allows for the use of Ethernet, which includes UDP and TCP/IP port setup.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 5 NOTE Communication Events include packet reque sts, download a job, received packet, timeouts, etc. If you place a checkmark in the box under Communications Display, you will see communication errors on the screen.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 6 Blocker Arm Load Position - Values are used to position the blocker arm so that it does not collide with the sl ot in the case top.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 7 The Advanced Screen Figure 3.7 – Advanced Screen This screen is discussed in detail in the la st chapter of this guide .
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 8 There are two other buttons that will allow you to check and save job log data for analysis of VC labels: • View Log • Copy Logs to Flash Drive To copy or look at the log, you must have the Activate Job Log Data box checked.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 2 9 The Statistics Screen Figure 3.9 - Statistics Screen The box labeled Job Count shows the number of Single Vision, Bifocals, Trifocals and Progressives that have been processed. There is a CLEAR button that will reset the counter for all of the lens types.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 0 (This page left blank intentionally for duplexing purposes.).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 1 Chapter 4 – Calibration Figure 4.1 – Calibration Screen A full calibration of the Clarity i nvolves the following five steps: Step 1: Preliminary Camera Focus: This step is performed from the Technician screen.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 2 Step 4 : Block Position Offsets – The oval calibration tem p late with a Vario block permanently mounted and the 70mm plano CR39 lens are required for th is calibration.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 3 On the Calibration screen under Step 4 (See Fig. 4.1), ther e are six parameters that describe the lens that will be analyzed: 1. Diameter 2. Index of Refraction 3. Power 4. Front Curve 5. Back Curve 6.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 4 Touch Screen Calibration Fig 4.2 Touch Screen Calibration Screen Touch Screen Calibration – In the upper right corner of the calibration screen there is a box titled Touch Screen Calibration.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 5 • Hold your finger over the blinking X and wh en it stops blinking, remove your finger and the X will move to the upper right hand corner. • Hold your finger over the blinking X and wh en it stops blinking, remove your finger and the X will move to the upper left hand corner.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 6 (This page intentionally left blank for duplexing purposes.).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 7 Chapter 5 – The Advanced Screen in the Setup Menu Figure 5.1 - Advanced Screen The Advanced screen has software adjustments for power, lens edge detection, lens diameter, prism, brightness of the camera im age, as well as updating software and data import, restore and backup.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 8 Near Power: 1. Number of Power Checks – How many tim es the Clarity will analyze the power. 2. Number of Power Targets – There are several d ifferent sized power targets that the Clarity uses to determine the power in different areas of the lens.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 3 9 Setup Password: The Setup Password is set at the factory to 082379. This feature allows you to change the password if you choose.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 0 (This screen intentionally left blank for duplexing pur poses.).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 1 Chapter 6 – Maintenance NOTE Always unplug unit before performing any maintenance. Cleaning the Glass Plate: Lift the glass plate out (See Fig. 1.5) and clean it using a microfiber cloth as used in cleaning A/R coated lenses.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 2 (This page left blank intentionally for duplexing purposes.).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 3 INTENDED USE & LIMITATIONS • This machine is designed to measure power, ax is and prism of ophthalmic lenses of all materials, and to place a block on axis at the geom etric center of the frame shape in a commercial laboratory environment.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 4 • Manual alignment of lenticular and o ccupational lenses is recomm ended. Occupationals could be aligned upside down in automatic mode.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 5 GLOSSARY OF TERMS Batch Blocking: Method of entering jobs. For example, with a stack of ten or more trays, you can enter or scan all jobs in succession and then star t to process them either by first in/ first out or last in/ first out.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 6 Shutter: Length of time of the exposure of the camera. Slope: For both plus and minus powered lenses. These fields in the Calibration screen are a linear correction for the range of powers the Clarity can check.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 7 Appendix A - General Specifications Machine Identification Clarity Ophthalmic Lens Analyzer and Finish Blocker Name and Address of Manufacturer N.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 8 Technical Specifications External Power Supply: Input: 100-240 V ~ 50 – 60 Hz 2A Output: +12 V DC 12.5 A 150 watts maximum Clarity Power Requirements: Input +12 V DC 5A Temperature: Operating 60°F to 90°F (10°C – 32.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 4 9 Appendix B - Certifications & Standards FCC Class A Device Compliance [Testing in Progress] NOTE: This equipment has been tested and found to com ply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 5 0 (This page left blank inten tionally for duplexing purposes.).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 5 1 Appendix C - Electrical Diagram [To be supplied.].
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 5 2 (This screen intentionally left blank for duplexing pur poses.).
Clarity User Guide, March 1, 2011 - Rev. 1.06 Page 5 3 Appendix D - Certificate of Compliance Note The following Declaratio n of Confor mity shall not be regarded a s operativ e unless it is included in a released (non-draft) versio n of this manual. In dr aft versions, it is included for planning purposes only.
Een belangrijk punt na aankoop van elk apparaat Clarity 87392-11 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Clarity 87392-11 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Clarity 87392-11 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Clarity 87392-11 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Clarity 87392-11 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Clarity 87392-11 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Clarity 87392-11 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Clarity 87392-11 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.