Gebruiksaanwijzing /service van het product CANpro/104-Plus van de fabrikant Connect Tech
Ga naar pagina of 22
USER MANUAL CANpr o/104 - Plus Opto CTIM-00052 Revision 0.00 - April 23, 2009.
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 2 800 -426-8979 | 519 -836-1291 Copyright Not ice The information contained in this document is s ubjec t to change without notice.
CANpro/104-Plus Opto User Manua l 3 www.connecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 Table of Content s Copyright Notice ..............................................................................................
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 4 800 -426-8979 | 519 -836-1291 Introduction CANpro/104 - Plus Opto co mbines the power of two indep endent NXP.
CANpro/104-Plus Opto User Manua l 5 www.connecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 CANpro/104- Plu s Opto Diagrams Figure 1 illustrate s the location o f each component on the CANpro /104- Plus Op to.
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 6 800 -426-8979 | 519 -836-1291 Figure 2: CANpro/104 - Plus Opto Board Dia gram.
CANpro/104-Plus Opto User Manua l 7 www.connecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 Hardware Inst allation Before You Begin Before you begin, take a minute to ensure that your package inclu des the req uired co mponents that should have shipped with your CANpro/104 - Plus Op to.
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 8 800 -426-8979 | 519 -836-1291 PCI Interrup t, Clock and ID Selection The following PCI signals, (I NT A#, INT.
CANpro/104-Plus Opto User Manua l 9 www.connecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 On -Board Jumper Config uration Figure 3: CAN Ports and J um per Locations 120 Ohm Termination Jumpers Jumpers J1 and J4 will enable a 120 Ohm termination resisto r across the CAN -H and CAN-L lines.
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 10 800 -426-8979 | 519 -836-1291 Figure 5: Exa mple CANpro/ 104- Plus Opto in the middle of the CAN bus NOTE: The 120 Oh m termination jumper does not need to be installed in this situation .
CANpro/104-Plus Opto User Manua l 11 www .co nnecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 Connector Pin outs Table 2: DB -9 Cable Connecto r Pinouts Pin No.
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 12 800 -426-8979 | 519 -836-1291 Software Confi guration The information pro vided belo w is intended for ad vanced users and developer s that wish to create their o wn custom drivers.
CANpro/104-Plus Opto User Manua l 13 www .co nnecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 Table 4 : CAN Contro ller #1 (BasicCAN) RE A D WRI T E RE A D WRI TE 0 x00 0.
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 14 800 -426-8979 | 519 -836-1291 Table 5 : CAN Contro ller #2 (B asicCAN) RE A D WRI T E R EAD WRI T E 0 x10 0 .
.
CANpro/104-Plus Opto User Manual CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 16 800 -426-8979 | 519 -836-1291 Table 6 : CAN Contro ller #1 (PeliCAN) L oc al Addr ess RE AD WRI TE 0x0 0 0 MO.
CAN pro/104-Plus Opto User Manual 17 www.connecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 Table 7 : CAN Contro ller #2 (PeliCAN) L oca l Addr e ss RE AD WRIT E 0x1 0 0 .
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 18 800 -426-8979 | 519 -836-1291 CAN Con troller Interrupts Each CAN controller is tied to a local interrupt on the P LX9030 which is then forwarded to a single interrupt on the PCI bus.
CANpro/104-Plus Opto User Manua l 19 www .co nnecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 GPIO Con trol and Addressi ng GPIO pins on the CANp ro/104 - Plus Opto are co ntrolled via the GPIOC register within the P LX 9030.
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 20 800 -426-8979 | 519 -836-1291 Specification s Operating Environment Storage temperature: - 40 C to 125 C Ope.
CANpro/104-Plus Opto User Manua l 21 www .co nnecttech.com CTIM-00052 Revision 0.00 4/23/2009 800 -426-8979 | 519 -836-1291 Certification Certifica tion for CANpr o/104- Plus Opto The CANpro/104 - Plus Opto p roduct family is to be included into a device ultimately subj ect to FCC, DOC/I C, and CE certification.
CANpro/104-Plus Opto User Manua l CTIM-00052 Revision 0.00 4/23/2009 www.connecttech.com 22 800 -426-8979 | 519 -836-1291 Limited Lifetim e Warranty Connect Tech Inc. p rovides a Lifeti me Warrant y for all Connect Tech Inc. pr oducts. Should this prod uct, in Connect Tech Inc.
Een belangrijk punt na aankoop van elk apparaat Connect Tech CANpro/104-Plus (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Connect Tech CANpro/104-Plus heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Connect Tech CANpro/104-Plus vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Connect Tech CANpro/104-Plus leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Connect Tech CANpro/104-Plus krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Connect Tech CANpro/104-Plus bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Connect Tech CANpro/104-Plus kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Connect Tech CANpro/104-Plus . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.