Gebruiksaanwijzing /service van het product 919.7255 van de fabrikant Craftsman
Ga naar pagina of 48
Operators Manual Permanently Lubricated 2-Stage Tw i n V Portable AIR COMPRESSOR • Safety Guidelines • Assembly • Operation • Maintenance • Service and Adjustments • T roubleshooting • Repair Parts Model No. 919.725500 CAUTION: Read the Safety Guidelines and All Instructions Carefully Befor e Operating.
2- ENG D24445 FULL ONE YEAR WARRANTY ON AIR COMPRESSORS If this air compressor fails due to a defect in material or workmanship within one year from the date of pur chase, RETURN IT TO THE NEAREST SEARS SERVICE CENTER THROUGHOUT CANADA AND SEARS WILL REP AIR IT , FREE OF CHARGE.
3- ENG D24445 SPECIFICA TION CHAR T Model No. 919-725500 Bore 2.375” Stroke High Pressur e - .54” Low Pressur e - 1.45” V oltage-Single Phase 120 Minimum Branch Circuit Requir ement 15 amps Fuse.
4- ENG D24445 RISK OF EXPLOSION OR FIRE AL WA YS OPERA TE THE COMPRESSOR IN A WELL VENTILA TED AREA FREE OF COMBUSTIBLE MA TERIALS, GASOLINE OR SOL VENT V APORS. IF SPRA YING FLAMMABLE MA TERIALS, LOCA TE COMPRESSOR A T LEAST 20 FEET AW A Y FROM SPRA Y AREA.
5- ENG D24445 RISK OF BURSTING AIR T ANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE T ANK, AND RESUL T IN A VIOLENT T ANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJUR Y . HOW TO PREVENT IT WHA T CAN HAPPEN DRAIN T ANK DAIL Y OR AFTER EACH USE.
6- ENG D24445 HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN RISK TO BREA THING AIR OBT AINED DIRECTL Y FROM THE COMPRESSOR SHOULD NEVER BE USED TO SUPPL Y AIR FOR HUMAN CONSUMPTION. IN ORDER TO USE AIR PRODUCED BY THIS COMPRESSOR FOR BREA THING, SUIT ABLE FIL TERS AND IN-LINE SAFETY EQUIPMENT MUST BE PROPERL Y INST ALLED .
7- ENG D24445 HOW TO PREVENT IT WHA T CAN HAPPEN RISK OF BURNS TOUCHING EXPOSED MET AL SUCH AS THE COMPRESSOR HEAD OR OUTLET TUBES, CAN RESUL T IN SERIOUS BURNS. NEVER TOUCH ANY EXPOSED MET AL P ARTS ON COMPRESSOR DURING OR IMMEDIA TEL Y AFTER OPERA TION.
8- ENG D24445 HAZARD HOW TO PREVENT IT WHA T CAN HAPPEN RISK OF UNSAFE OPERA TION REVIEW AND UNDERST AND ALL INSTRUCTIONS AND WARNINGS IN THIS MANUAL. BECOME F AMILIAR WITH THE OPERA TION AND CONTROLS OF THE AIR COMPRESSOR. KEEP OPERA TING AREA CLEAR OF ALL PERSONS, PETS, AND OBST ACLES.
9- ENG D24445 ACCESSORIES This unit is capable of powering the following Accessories. The accessories are available through the curr ent Power and Hand T ool Catalog or full-line Sears stores.
10- ENG D24445 Assemble Wheels It will be necessary to brace or support one side of the outfit when installing the wheels because the compressor will have a tendency to tip. 1. Attach wheels with shoulder bolts and nuts as shown. 2. Tighten securely .
11- ENG D24445 INST ALLA TION HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air .
12- ENG D24445 Extension Cords Use extra air hose instead of an extension cord to avoid voltage dr op and power loss to the motor , and to prevent overheating.
13- ENG D24445 T ank Pressur e Gauge: The tank pressur e gauge indicates the reserve air pressur e in the tank. Regulator: Controls the air pr essure shown on the outlet pressur e gauge. Pull the knob out and turn clockwise to increase pr essure and counterclockwise to decr ease pressur e.
14- ENG D24445 Cooling System (not shown) : This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. Y ou know that the cooling system is working when air is being expelled.
15- ENG D24445 How to Start: 1. T ur n the On/Auto/Off lever to “AUTO” and allow tank pressur e to build. Motor will stop when tank pressur e reaches “cut-out” pressur e. 2. Pull the regulator knob out and turn clockwise to increase pressur e.
16- ENG D24445 MAINTENANCE Customer Responsibilities Daily or after each use Before each use ● ● ● Every 40 hours Every 100 hours Y early ● 1 1- more fr equent in dusty or humid conditions Check Safety V alve Drain T ank Air Filter NOTE: See “Operation” section for the location of controls.
17- ENG D24445 6. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE : If drain valve is plugged, release all air pr essure. The valve can then be removed, cleaned, the reinstalled. Air Filter - Inspection and Replacement Hot surfaces.
18- ENG D24445 7. Unscrew the check valve (turn counterclockwise) using a 7/8” open end wrench. Note the orientation for reassembly . 8. Using a screwdriver , carefully push the valve disc up and down.
19- ENG D24445 6. Assemble the regulator and orient as shown. NOTE: Arrow indicates flow of air . Make sure it is pointing in the direction of air flow . 7. Reapply pipe sealant to outlet pressur e gauge and quick connect. 8. Reassemble outlet pressur e gauge and quick connect.
20- ENG D24445 STORAGE Before you stor e the air compressor , make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to “OFF”.
21- ENG D24445 TROUBLESHOOTING Performing repairs may expose voltage sour ces, moving parts or compressed air sour ces, moving parts or compressed air sour ces. Personal injury may occur . Prior to attempting any repairs, unplug the air compr essor and bleed off all air tank air pressur e.
22- ENG D24445 PROBLEM CAUSE CORRECTION It is normal for “some” pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the “Description of Operation” paragraph in the “Operation Section.
23- ENG D24445 Regulator will not shut off air outlet. Damaged regulator Replace PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit br eaker tripped.
HOW TO ORDER REP AIR P ARTS Model No. 919.725500 Sold by Sears Canada, Inc. T oronto, Ont. M5B 2B8 SERVICE OWNERS MANUAL FOR PERMANENTL Y LUBRICA TED 2-ST AGE, TWIN V , POR T ABLE AIR COMPRESSOR The m.
Guide de l’utilisateur Compr esseur d'air double portatif à deux étages et à lubrification permanente • Mesures de sécurité • Assemblage • Fonctionnement • Entretien • Entretien et Réglage • Guide de dépannage • Pièces de rechange Modèle nº 919.
2- FR D24445 GARANTIE COMPLÈTE DE UN AN SUR LES COMPRESSEURS D’AIR Ce compresseur d’air est garanti contr e tout défaut de fabrication pour une période de un an, à compter de la date d’achat. Au cours de cette période de garantie, SEARS S’ENGAGE À LE RÉP ARER SANS FRAIS.
3- FR D24445 T ABLEAU DES SPÉCIFICA TIONS Modèle no : 919-725500 Alésage 1 7/8 po (4,76 cm) Course du cylindre 1 1/4 po (3,175 cm) T ension – phase unique 120 Exigence minimale du circuit de dérivation 15 a Genre de fusible à retar dement à élément double Capacité du réservoir d’air 12 gal.
4- FR D24445 RISQUE D’EXPLOSION OU D’INCENDIE PRÉVENTION RISQUE DANGER LES ÉTINCELLES QUI PROVIENNENT DES CONT ACTS ÉLECTRIQUES DU MOTEUR ET DU MANOST A T SONT CONSIDÉRÉES NORMALES.
5- FR D24445 RISQUE D’ÉCLA TEMENT RÉSERVOIR D’AIR : LES CONDITIONS SUIV ANTES PEUVENT AFF AIBLIR LES P AROIS DU RÉSERVOIR ET PROVOQUER UNE EXPLOSION VIOLENTE DU RÉSERVOIR QUI RISQUE DE CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES GRA VES.
6- FR D24445 DANGER RISQUE DE CHOC ÉLECTRIQUE NE JAMAIS F AIRE FONCTIONNER LE COMPRESSEUR À L ’EXTÉRIEUR LORSQU’IL PLEUT OU DANS DES CONDITIONS HUMIDES. NE JAMAIS F AIRE FONCTIONNER LE COMPRESSEUR SANS LES COUVERCLES DE PROTECTION OU LORSQUE CEUX-CI SONT ENDOMMAGÉS.
7- FR D24445 RISQUE DE BRÛLURES LE F AIT DE TOUCHER AUX SURF ACES DE MÉT AL EXPOSÉES TELLES QUE LA TÊTE DU COMPRESSEUR OU LES TUBES DE SORTIE PEUT CAUSER DE GRA VES BRÛLURES À LA PEAU. NE JAMAIS TOUCHER AUX PIÈCES DE MÉT AL EXPOSÉES DU COMPRESSEUR DURANT OU IMMÉDIA TEMENT APRÈS LE FONCTIONNEMENT .
8- FR D24445 DANGER RISQUE D'UNE UTILISA TION DANGEREUSE UNE UTILISA TION DANGEREUSE DE VOTRE COMPRESSEUR D'AIR POURRAIT CAUSER DES BLESSURES GRA VES OU LA MORT DE L'UTILISA TEUR OU D'AUTRES PERSONNES. PRÉVENTION RISQUE LISEZ A TTENTIVEMENT TOUS LES INSTRUCTIONS ET LES A VERTISSEMENTS FIGURANT DANS CE GUIDE.
9- FR D24445 LEXIQUE V euillez vous familiariser avec ces termes avant d'utiliser l'appareil. CFM : pieds cubes par minute (pi 3 /min) . SCFM : pieds cubes par minute (pi 3 /min) standard. Une unité de mesur e de débit d'air . PSIG: jauge indiquant le nombre de livr es par pouce carré (lb/po 2 ).
10- FR D24445 Assemblage des roues Il s'avérera nécessaire de supporter un côté de l'appareil lors du montage des r oues parce que le compr esseur d'air aura tendance à basculer . 1. Attachez les roues avec les boulons à épaulement et les écrous, tel qu'illustré.
11- FR D24445 2. Assur ez-vous que la prise de courant utilisée a la même configuration que la fiche de mise à la terre. NE P AS UTILISER UN ADAPT A TEUR . V oir l'illustration. 3. Inspectez la fiche et le cor don avant chaque utilisation. Ne pas les utiliser s'il y a des signes de dommages.
12- FR D24445 Rallonges Utilisez un boyau d'air supplémentaire au lieu d'une rallonge pour éviter une chute de tension, une perte de puissance et la surchauf fe du moteur .
13- FR D24445 Régulateur : Le régulateur contrôle la pression d'air indiqué sur le manomètr e de sortie. Tirez le bouton et tournez-le dans le sens des aiguilles d'une montre pour augmenter la pression et dans le sens contraire pour réduir e la pression.
14- FR D24445 Avant le démarrage Procédur es de rodage Le compresseur d'air peut subir d'importants dom- mages si les procédur es de rodage ne sont pas suivies à la lettre.
15- FR D24445 4. Placez le levier "On/Auto/Off" à la position "ON/AUTO". Le compresseur se mettra en mar che. 5. Faire fonctionner le compr esseur pendant 15 minutes. Assurez-vous que le robinet de vidange est ouvert et que la pression d'air accumulée dans le réservoir est minimale.
16- FR D24445 ENTRETIEN Responsabilités du client ● ● ● ● 1 1- more fr equent in dusty or humid conditions Vérifier la soupape de sûreté Vidanger le réservoir Filtre à air Soupapes d&apo.
17- FR D24445 Filtre à air - Inspection et remplacement Surfaces chaudes. Risque de brûlures. La tête du compresseur est exposée lorsque le couvercle de filtr e est enlevé. Attendez jusqu'à ce que le compresseur soit refr oidi avant de procéder à l'entr etien.
18- FR D24445 7. À l'aide d'une clé ouverte de 7/8 po, dévissez la soupape de retenue (en tournant dans le sens contraire des aiguilles d'une montre). REMARQUE : l'orientation pour l'assemblage plus tar d. 8. À l'aide d'un tour nevis, poussez doucement le disque de soupape vers le haut et vers le bas.
19- FR D24445 6. Assemblez le régulateur et orientez-le tel qu'illustré. REMARQUE : La flèche indique le sens du débit d'air . Assurez-vous qu'elle est dirigée dans la direction du débit d'air . 7. Appliquez un produit d'étanchéité au manomètre de sortie et au raccord à connexion rapide.
20- FR D24445 RANGEMENT Avant de ranger le compr esseur d'air , effectuez les étapes suivantes : 1. Revoyez la section intitulée "Entretien" des pages précédentes et exécutez l'entretien r equis. 2. Placez le levier "On/Auto/Off" à la position "OFF".
21- FR D24445 DÉP ANNAGE En effectuant des réparations au compr esseur , il se peut que vous soyez exposé aux sources de tension, aux pièces mobiles ou aux sources d'air comprimé qui risquent de causer des blessures corpor elles.
22- FR D24445 Une légère chute de pr ession est considérée normale. S'il y a une chute excessive de pression lorsqu'un accessoir e est utilisé, ajustez le régulateur en suivant les directives du paragraphe intitulé "Description du fonctionnement" de la section sur l'utilisation.
23- FR D24445 Le régulateur ne ferme pas l'orifice de sortie d'air . Régulateur endommagé Remplacez le régulateur . PROBLÈME CAUSE CORRECTION Le moteur ne tourne pas. Interrupteur de protection contr e les surchar ges déclenché. La pression dans le réservoir est supérieure à la "pr ession d'amorçage" du manostat.
POUR PLACER UNE COMMANDE DE PIÈCES DE RECHANGE Modèle nº 919.725500 V endu par Sears Canada, Inc. T oronto, Ont. M5B 2B8 SERVICE GUIDE DE L ’UTILISA TEUR POUR COMPRESSEUR D'AIR DOUBLE PORT A.
Een belangrijk punt na aankoop van elk apparaat Craftsman 919.7255 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Craftsman 919.7255 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Craftsman 919.7255 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Craftsman 919.7255 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Craftsman 919.7255 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Craftsman 919.7255 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Craftsman 919.7255 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Craftsman 919.7255 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.