Gebruiksaanwijzing /service van het product DIN Rail Control Processor DIN-AP2 van de fabrikant Crestron
Ga naar pagina of 40
Crestron Green Light™ DIN-AP2 DIN Rail Control Processor Operations & Installation Guide.
This document was prepared and written by th e Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand nam es, product names and trade marks are the property of t heir respective ow ners.
Crestron DIN-AP2 DIN Rail Control Processor Contents Crestron Green Light™ DIN Rail Control Processor: DIN-AP2 1 Introduc tion ................................................................................................................... ......
.
Crestron DIN-AP2 DIN Rail Control Processor Crestron Green Light™ DIN Rail Control Processor: DIN-AP2 Introduction The DIN-AP2 is a 2-Series control processor designed for small to medium-sized lighting and automati on applications.
DIN Rail Control Processor Crestron DIN-AP2 2-Series Processor Built upon Crestron’s reliable 2-Series control engine, the DIN-AP2 is extensively programmable using Crestron’s suite of powerful development software and vast database of driver s and software modules.
Crestron DIN-AP2 DIN Rail Control Processor Cresnet Power Supply is required to power the DIN-AP2 and any connected Cresnet devices. Ethernet and e-Control ® 2 Built-in 10/100 Ethernet facilita tes s.
DIN Rail Control Processor Crestron DIN-AP2 Applications The following diagram shows a DIN- AP2 in a typical application. DIN-AP2 in a Typical Application 4 • DIN Rail Control Processor: DIN-AP2 Operations & Installation Guide – DOC.
Crestron DIN-AP2 DIN Rail Control Processor Specifications Specifications for the DIN-AP2 are listed in the following table. DIN-AP2 Specifications SPECIFICATION DETAILS CPU 32-bit Freescale ColdFire .
DIN Rail Control Processor Crestron DIN-AP2 DIN-AP2 Specifications (Continued) SPECIFICATION DETAILS Enclosure Light gray polycarbonate housing with polycarbonate label overlay, UL94 V-0 rated, 35 mm DIN EN 60715 rail mount, DIN 43880 form factor for enclosures with 45 mm front panel cutout, occupies 9 DIN module spaces (162 mm).
Crestron DIN-AP2 DIN Rail Control Processor Physical Description This section provides information on the connections, controls and indicators available on your DIN-AP2. DIN-AP2 Physical View DIN-AP2 Overall Dimensions 90 mm (3.54 in) 58 mm (2.28 in) 159 mm (6.
DIN Rail Control Processor Crestron DIN-AP2 Connectors, Controls & Indicators # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 1 I/O VERSIPORTS 1-8 (1) 9-pin 3.5mm detachable terminal block comprising (8) digital input/output or analog input ports (referenced to GND) Max Wire Size: 1.
Crestron DIN-AP2 DIN Rail Control Processor Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 4 MSG LED (1) Red LED, illuminates when a message is present in the message log. To view the contents of the message log, use Crestron Toolbox™.
DIN Rail Control Processor Crestron DIN-AP2 Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 9 COM1 & COM 2 (2) 5-pin 3.5 mm detachable terminal blocks, bidirectional comprising (2) RS-232 ports Max Wire Size: 1.
Crestron DIN-AP2 DIN Rail Control Processor Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 11 LAN GREEN LED YELLOW LED PIN 8 PIN 1 (1) 8-wire .
DIN Rail Control Processor Crestron DIN-AP2 Industry Compliance This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United St ates.
Crestron DIN-AP2 DIN Rail Control Processor Setup Network Wiring When wiring the Cresnet and Ethernet network, consider the following: • Use Crestron Certified Wire. NOTE: Cresnet-HP wire cannot be used. • Use Crestron power supplies for Crestron equipment.
DIN Rail Control Processor Crestron DIN-AP2 The DIN-AP2 is designed for insta llation on a DIN rail. Refer to the following diagram when installing. Installing the DIN-AP2 DIN RAIL RELEASE DIN-AP2 TOP DIN RAIL (NOT SUPPLIED) 1. Place the top of the DIN-AP2’s rail mount over the top of the DIN rail.
Crestron DIN-AP2 DIN Rail Control Processor Hardware Hookup Connect th e Device Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “ Network Wiring ” on page 13 before attaching the 4-position terminal block connector.
DIN Rail Control Processor Crestron DIN-AP2 Hardware Connections for the DIN-AP2 NET : PO W ER F RO M DI N- PW S 50 O R O T HER CRES NET PO W ER SUPPLY .
Crestron DIN-AP2 DIN Rail Control Processor Versiport Connectio ns Depending on the application, the DIN-AP2’s Versiports can be wired multiple ways. Refer to th e following diagrams when wiring a Versiport. WARNING: Incorrect wiring may da mage the DIN-AP2 or the connected device.
DIN Rail Control Processor Crestron DIN-AP2 Versiport Wiring Diagrams—Analog Input Function I/ O S e t u p : A nal og I nput Pul l - up R esist or : D i s abl ed R eading a v olt age f rom an anal o.
Crestron DIN-AP2 DIN Rail Control Processor Programming Software Have a question or comment about Crestron software? Answers to frequently asked questi ons (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestr on’s True Blue Support, log in at http://support.
DIN Rail Control Processor Crestron DIN-AP2 Programming with Crestron SystemBuilder Crestron SystemBuilder is the easi est method of programming but does not offer as much flexibility as SIMPL Windows. For additional details, download SystemBuilder from the Cr estron website and examine the extensive help file.
Crestron DIN-AP2 DIN Rail Control Processor Locating the DIN-AP2 in the Device Library Program Manager Program Manager is the view wher e programmers “program” a Crestron control system by assigning signals to symbols. The symbol can be viewed by double clicking on the icon or dragging it into Detail View .
DIN Rail Control Processor Crestron DIN-AP2 Uploading and Upgrading Crestron recommends using the lat est programming software and that each device contains the latest firm ware to take advantage of the most recently released features. However, before atte mpting to upload or upgrade it is necessary to establis h communication.
Crestron DIN-AP2 DIN Rail Control Processor marked Ethernet however, communications must be established in order to see this information in the “System Info” window. • Display the DIN-AP2’s “Sys tem Info” window (click the icon); communications are confirme d when the device information is displayed.
DIN Rail Control Processor Crestron DIN-AP2 Programs and Firmware Program or firmware files m ay be distributed from programmers to installers or from Crestron to dealer s. Firmware upgrades are available from the Crestron website as new fe atures are developed after product releases.
Crestron DIN-AP2 DIN Rail Control Processor Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations.
DIN Rail Control Processor Crestron DIN-AP2 DIN-AP2 Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION MSG LED illuminates. Hardware or software failure, hardware incompatibility with software definitions or programming error. Verify that hardware configuration matches software configuration.
Crestron DIN-AP2 DIN Rail Control Processor DIN-AP2 Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Device not wired correctly. Verify Cresnet wiring. Improper NET ID used. Verify that device ID matches NET ID in the program. Cresnet device does not respond.
DIN Rail Control Processor Crestron DIN-AP2 6. Once the DIN-AP2 is in Monitor mode, connect to the PC using a USB cable. NOTE: If at any point in the above sequence, one of the timer periods expires without the SW-R button being pressed, the unit will boot normally, first running the firmware, then loading the application.
Crestron DIN-AP2 DIN Rail Control Processor 12. Find and select the correct firmwa re file (.CUZ or .zip) and click Open . 13. In the “Firmware” window, click Send . You will see a “Confirmation” window asking if you’ve selected the right file.
DIN Rail Control Processor Crestron DIN-AP2 When calculating the length of wire fo r a particular Cresnet run, the wire gauge and the Cresnet power usage of each network unit to be connected must be taken into consideration. Use Crestron Certified Wire only.
Crestron DIN-AP2 DIN Rail Control Processor Reference Documents The latest version of a ll documents mentioned w ithin the guide can be obtained from the Crestron website ( www.crestron.com/manuals ). This link will provide a list of product ma nuals arranged in alphabetical order by model number.
DIN Rail Control Processor Crestron DIN-AP2 Software License Agreement This License Agreement (“Agree ment”) is a legal contract betw een you (either an individual or a single business entity) and Crestron Electronics, Inc.
Crestron DIN-AP2 DIN Rail Control Processor If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully document an.
DIN Rail Control Processor Crestron DIN-AP2 Return and Warranty Policies Merchandise Returns / Repair Service 1. No m erchandise m ay be returned for cre dit, exchange or service with out prior authorization from CR ESTRON. To obt ain warranty serv ice for CREST RON products, contact an authorized CRESTRON deal er.
Crestron DIN-AP2 DIN Rail Control Processor Operations & Installation Guide – DOC. 6662A DIN Rail Control Processor: DIN-AP2 • 35 This page is intentionally left blank.
Crestron Electronics, Inc. Operations & Installation Guide – DOC. 6662A 15 Volvo Drive Rockleigh, NJ 07647 (2020744) Tel: 888.CRESTRON 06.08 Fax: 201.
Een belangrijk punt na aankoop van elk apparaat Crestron DIN Rail Control Processor DIN-AP2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Crestron DIN Rail Control Processor DIN-AP2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Crestron DIN Rail Control Processor DIN-AP2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Crestron DIN Rail Control Processor DIN-AP2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Crestron DIN Rail Control Processor DIN-AP2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Crestron DIN Rail Control Processor DIN-AP2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Crestron DIN Rail Control Processor DIN-AP2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Crestron DIN Rail Control Processor DIN-AP2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.