Gebruiksaanwijzing /service van het product Iron-Cleer van de fabrikant Culligan
Ga naar pagina of 23
Culligan ® Iron-Cleer ® Automatic Water Filter Owners Guide.
.
THANK YOU AND WELCOME TO YOUR NEW WORLD OF BETTER LIVING WITH CULLIGAN WATER. The Culligan ® Iron Cleer ® water filters have been tested and certified by WQA against WQA-200 for the effective reduction of iron up to 1,400 gallons for 10” units and 2,000 gallons for 12” units.
Table of Contents 4 S p e c i f i c a t i o n s ...................................................... 1 I n t r o d u c t i o n ....................................................... 2 O p e r a t i n g C o n d i t i o n s ..........................
Specifications Culligan ® Iron Cleer ® Filters 1 Capacity based on 4 gpm and 10 mg/L of dissolved iron. 2 Measured from top of media bed to top of inlet fitting. 3 Max flow rates & pressure drop characteristics have not been validated by the Water Quality Association.
Introduction Operation Step 1. Aeration Operation Service Cycle In the service cycle, raw water enters the inlet port of the aeration tank and is directed through the inlet diffuser. The oxidation process begins when the water passes through the inlet diffuser and cascades through a head of air.
Shuttle Valve Operation In the service position, water pressure holds the shuttle valve piston in the closed position, trapping the airhead in the aeration tank and closes the air recharge inlet port and drain port. During air recharge cycle, air pressure is greater than the water pressure and forces the shuttle valve piston in the open piston.
The concentration limits listed below reflect the maximum individual limit that each contaminant was tested for separately without any interference of other contaminants in the influent water.
Fam ilia riza tio n Power Loss The AccuSoft ® circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The capacitor is capable of maintaining the time, for at least two days, in the event of a power outage. The EEPROM ensures that the individual programming parameters of your filter are not lost.
Programming 6 Make sure either inlet water supply is turned off, then supply power to the timer. The display will power up ashing “12:00 PM” and the motor will energize and cycle the control, without stopping, the home position. This is required to ensure that the control is in the home position.
7 Pressing the “Status” key will save the setting and move to the next programming step. Settline Time This setting is used to set the time in minutes for cycle 2. This cycle is usually brine draw / slow rinse for softeners and a settling time for lters.
Normally , all water except outside lines passes through the water lter . There are times when the water lter should be bypassed, using the Cul-Flo-V alv ® Bypass, or a 3-way bypass valve.
9 Aeration T ank – Bypass V alve Operation Normal Operation Bypass Operation “T reated” Water Exits Supply W ater Enters Supply W ater Exits Supply W ater Enters Shut-Off Mode No W ater Exits Su.
Things to Check Before You Call for Service If you unexpectedly experience problem water, make these simple checks before calling your Culligan dealer.
Care and Cleaning of Your Water Conditioner 11 Following these simple precautions will help assure continued trouble-free service and keep your Culligan W ater Conditioner looking like new for years. 1 Use only mild soap and warm water when cleaning the exterior of the conditioner .
Preventative Maintenance Recommended Preventative Maintenance The Culligan Iron Cleer water filter has been designed to provide a good, consistent service life. Because of the nature of problem water, we recommend that the local Culligan dealer provide regular maintenance/service contracts for the proper operation of your systems.
T r ou bl e sh oo t i n g Guide 13 Complaint Problem Cause Solution Iron bleed- through or staining. A. Inadequate backwash of filter 1. Plugged drain line flow control 1. Call your Culligan dealer for service. 2. Insufficient water supply from well. 2.
Complaint Problem Cause Solution Water leaking from relief valve. A. Dirt lodged under seat of valve. 1. Pressure has exceeded rating on relief valve and caused valve to open 1. Call your Culligan dealer for service. B. Faulty or defective relief valve 1.
15 Complaint Problem Cause Solution Excessive noise during regeneration. A. Howling or whistling noise during regeneration cycle. 1. Inadequate drain line size. 1. Call your Culligan dealer for service. 2. Drain line is vibrating against other pipes, conduits, pipe hangers, heat ducts, floor joists,etc.
Performance Data Sheet Culligan ® 10” and 12” Iron-Cleer ® Water Filters Important Notice — Read this data sheet and compare the capabilities of the unit to your actual water treatment needs. Culligan recommends that you have your water supply tested to determine these needs before purchasing a water treatment unit.
17 Records and Data Important Data on Your Water Filter It is advisable to have the salesperson or installer fill in the information below for your future reference. If this has not been done, please ask for it, as it is necessary if you contact your dealer.
Culligan Limited Warranty Culligan ® Iron-Cleer ® Automatic Water Filters You have just purchased one of the finest water filters made. As an expression of our confidence in Culligan International C.
With Culligan You Get More Than A Quality Product You Get Your Water Expert, The Culligan Man We’re here to provide you with fast, dependable service, making sure any problems you have are taken care of. The Culligan Man has been around for over sixty years, delivering dependable service all along.
Een belangrijk punt na aankoop van elk apparaat Culligan Iron-Cleer (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Culligan Iron-Cleer heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Culligan Iron-Cleer vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Culligan Iron-Cleer leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Culligan Iron-Cleer krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Culligan Iron-Cleer bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Culligan Iron-Cleer kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Culligan Iron-Cleer . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.