MODEL 2100R & 2200R Engine Gages Read Instructions Carefully ! !.
Saf ety Instructions This instrument was manuf actured and tested according to the applicable technical standards . It complies with all the safety regulations as shipped from the f actory . Installation and star tup must be performed by skilled personnel.
! ! T ABLE OF CONTENTS P age 1. Saf ety Instructions 2 2. Model Encodement 3 3. T echnical Specifications 3.1 Electrical 5 3.2 Mechanical 8 3.3 Environmental 9 4.
3 2. MODEL ENCODEMENT (f or 2100R/2200R series) 2111RXX-YYYY ZZ Model Numbers 2111 T emperature 2112 Fuel 2113 Pressure 2114 V oltage 2211 T emperature/Hour 2212 Fuel/Hour 2213 Pressure/Hour 2214 V ol.
4 R = case (round) XX = v oltage (DC v oltages only) YYYY = sequential number code describes gage’ s f actor y programming ZZ = ar twork code (OO = Cur tis) !.
5 3. TECHNICAL SPECIFICA TIONS 3.1 Electrical Operating V oltage Model Series 2100R and 2200R are availab le in either 12VDC or 24VDC (negative g round systems only) Operating V oltages (Models 2111R, 2112R, 2113R and 2211R, 2212R, 2213R) Model Minimum Nominal Maximum 12V 9.
Operating Current T otal system current is a function of the voltage, sender type, displa y mode, and the gage’ s factory programming. T ypical operating currents (not including the current to drive the sender) v ar y from 16-55 mA, f or 12V models , depending on model number .
Output signal trigger point (lower) First LED Second LED Output signal trigger point (upper) Ninth LED T enth LED Output signal format—(upper and lower independently set) 0-5 V 5-0 V* LED flashing m.
Damping and Hysteresis Tr ansducer po wer modulation (XPM) Used to reduce current in sender circuit Output signal f ormat Outputs are capable of sinking or sourcing up to 1mA, maximum (50 µ A maximum is standard) The 5V -0 output signal format is fully compatible with the Cur tis Model 1178 relay module.
Bezel Material Aluminum, blac k anodized Hardware U clamp (1) (Individually box ed 4 mm lock washers (2) un it s ) F emale 1/4 inch fast-on connectors (up to 6) 4 mm knurled thumbnuts (2) Hardware U clamp (1) (OEM bulk pac ked) 4 mm lock w ashers (2) 4 mm hex n uts (2) 3.
Vibration Meets SAE J 1378 March 83. Double amplitude of 1.53 mm with frequency sw eep from 10-80-10 Hz (20 g max) at intervals of 1 minute. Humidity 95% RH (non-condensing) at +38C Wa ter/dust immunity F ace IP63 Rear IP50 Salt spra y (fog) ASTM B 117-73 as per SAE J1810, section 4.
4. INST ALLA TION Te r m inal Assignment f or Models 2111R, 2112R, 2113R 1 Sender in 2B attery + 3G round 4 Sender low (optional: for use with two wire senders) 5 Output signal (upper) 6 Output signal.
Te r minal Assignment f or Model 2114R 1 Not Connected ** 2B attery + 3G round 4 Not Connected** 5 Output signal (upper) 6 Output signal (lower) Te r minal Assignments f or Models 2211R, 2212R, 2213R .
Te r minal Assignments f or Model 2214R 1 Not connected*** 2B attery + 3G round 4 Hourmeter enable*** 5 Output signal (upper) 6 Output signal (lower) * Options terminal can be factory programmed to fu.
5. TR OUBLESHOO TING The follo wing checklist should help y ou to trou- b leshoot an y problems with the instrument. T urning the instrument off and then on again after about 10 seconds may solv e the prob lem in the simplest cases. Make sure to observe the saf ety instructions in Section 1.
6. MAINTENANCE Cur tis 2100R & 2200R Series Engine Gages are not serviceable in the field. Units returned to the f actory within the warranty period will be replaced without charge.
Guarantee - These Curtis Instr uments’ products are guaran- teed against defects in w orkmanship and material for a period of three years , or as defined in the individual product literature, from date of shipment from our factory , when applied in a prop- er application within specified ratings.
CURTIS INSTRUMENTS, INC. 200 Kisco A venue, Mt. Kisco, NY 10549 T el. (914) 666-2971 • FAX (914) 666-2188 53018 REV A 10/97.
Een belangrijk punt na aankoop van elk apparaat Curtis 2200R (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Curtis 2200R heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Curtis 2200R vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Curtis 2200R leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Curtis 2200R krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Curtis 2200R bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Curtis 2200R kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Curtis 2200R . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.