Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Matrix 400™ Reference Manual Ed.: 12/2008 ALL RIGHTS RESERVED Datalogic reserves the right to make modificati ons and improvements without prior notification.
iii CONTENTS REFERENCES ............................................................................................................ vi Conventions .......................................................................................................
iv 4.3 ID-NET™ Interface ..................................................................................................... 50 4.3.1 ID-NET™ Cables ................................................................................................
v 8.4.6 Region Of Interest Windowing .................................................................................. 117 8.4.7 Direct Part Marking Applications............................................................................... 118 8.5 Image Capture and Decoding .
vi REFERENCES CONVENTIONS This manual uses the following conventions: "User" refers to anyone using a Matrix 400™ reader. "Reader" refers to the Matrix 400™ reader.
vii COMPLIANCE For installation, use and maintenance it is not necessary to o pen the reader. EMC COMPLIANCE In order to meet the EMC requirements: connect reader chassis to the plant earth gr oun.
viii HANDLING The Matrix 400™ is designed to be used in an industrial environment and is built to withstand vibration and shock when correctly installed, however it is also a precision prod uct and therefore before and during installation it must be handled correctly to avoid damage.
ix do not weld the reader into position which can cause electrostatic, heat or reading window damage. do not spray paint near the reader which can cause reading window damage.
x GENERAL VIEW Matrix 400™ Figure A 1 2 3 4 9 8 7 Device Clas s Label Mounting Holes (12) Lens Cover Lens (separate accessory) "POWER ON" LE D Power - Se rial Int erface s - I/O Conne ctor.
RAPID CONFIGURATION 1 1 1 RAPID CONFIGURATION STEP 1 – ASSEMBLE THE READER The first step to perform is to assemble the accessories that make up the Matrix 400™ reader. The lens and either an internal or an external illuminator must be us ed. This procedure shows an internal illuminator.
MATRIX 400™ REFERENCE MANUAL 2 1 Required Access ories The following table shows the corr ect lens/illuminator combinations to be use d for Matrix 400™ imager assembly.
RAPID CONFIGURATION 3 1 CBX100/CBX500 Pinout for Matrix 400™ The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this pinout when the Matrix 400™ reader is connect.
MATRIX 400™ REFERENCE MANUAL 4 1 19-pin Connector P inout for Matrix 400™ The table below gives the pinout of the 19-pin M16 male connector for connection to the power supply and input/output signals.
RAPID CONFIGURATION 5 1 STEP 3 – MOUNT AND PO SITION THE READER 1. To mount the Matrix 400™, use the mounting brackets to obtain the most suitable position for the reader. Two of the most common mounting configurations are shown in the figures below.
MATRIX 400™ REFERENCE MANUAL 6 1 3. Refer to the Reading Features table in chp. 7 for FOV calculation and minimum distance requirements according to the base/lens combination used for your application.
RAPID CONFIGURATION 7 1 FOV Blue Diamond™ in focus Figure 8 – Focus Function Using Blue Dia monds™ 6. Exit the Focus functio n by pressing the X-PRESS™ push button once. The Blue Diamonds™ turn off. 7. Replace the lens cover, screwing it tightly to the base.
MATRIX 400™ REFERENCE MANUAL 8 1 Setup 5. Enter the Setup function by pressing and holding the X-PRESS™ push button until the Setup LED is on. 6. Release the button to enter the Setup function. The Setup LED will blink until the procedure is completed.
RAPID CONFIGURATION 9 1 STEP 6 – X-PRESS™ CONFIGURATION Once Matrix 400 ™ has calibrated image density, you can configure it for optimal code reading relative to your application. This configuration can be performed either through the X- PRESS™ Interface or the VisiSet™ configuration program.
MATRIX 400™ REFERENCE MANUAL 10 1 Learn 8. Enter the Learn function by pressing and holding the X-PRESS™ push button until the Learn LED is on. 9. Release the button to enter the Learn function. The Learn LED will blink until the procedure is completed.
RAPID CONFIGURATION 11 1 STEP 7 – INSTALLING VISISE T™ CONFIGURATION PROGRAM VisiSet ™ is a Datalogic reader configuration tool providing several important advantages: Setup Wizard for rapid.
MATRIX 400™ REFERENCE MANUAL 12 1 Set the communication parameters from the "Options" menu. Then select "Connect", the following window appears: Figure 16 - VisiSet™ Ma in Window After Connection STEP 8 – CONFIGURATIO N USING SETUP WIZARD The Setup Wizard option is advised for rapid configuration or for new users.
RAPID CONFIGURATION 13 1 2. Remove the lens cover in order to focus the reader and loosen the two Locking Knobs on the lens. Adjust the Focus ring to the " Far position " and the Diaphragm ring to the " F4 " 2 number setting which is the preferred setting for installation.
MATRIX 400™ REFERENCE MANUAL 14 1 4. Select a Calibration Mode choice and press the "Calibrate" button. Th e reader flashes once acquiring the image and auto determines the best exposure and gain settings. If the code symbology is enabled by default, the code will also be decoded.
RAPID CONFIGURATION 15 1 Continue rotating the Focusing ring on the lens a little farther; the Current Focus Quality Bar decreases (red) see below. Rotate the Focusing ring in the opposite direction.
MATRIX 400™ REFERENCE MANUAL 16 1 6. Select a Code Setting Mode choice and press the "Code Setting" button. Using the Grade A Barcode Test Chart , this step performs image density calibration in order for Matrix 400™ to function correctly and to the fullest extent of its capabilities.
RAPID CONFIGURATION 17 1 8. Select a Saving Options choice and press the "Save" button. 9. Close the Setup Wizard. NOTE If your application has been configured using the VisiSet™ Setup Wizard, your reader is ready. If necessary you can use VisiSet™ for advanced reader configuration.
MATRIX 400™ REFERENCE MANUAL 18 1 STEP 9 – TEST MODE Use a code suitable to your application to test the reading pe rformance of the system. 1. Enter the Test function by pressing and holding the X-PRESS™ push button until the Test LED is on. 2.
RAPID CONFIGURATION 19 1 ADVANCED READER CONFIGURATION For further details on advanced product configuration, refer to the VisiSet™ Help On-Line. The following are alternative or advanced reader con.
MATRIX 400™ REFERENCE MANUAL 20 2 2 INTRODUCTION 2.1 PRODUCT DESCRIPTION Matrix 400™ is a Datalogic industrial compact 2D imager designed and produced to be a high performance affordable solution for bot h linear and two-dimensional code reading applications.
INTRODUCTION 21 2 Standard Application Program A Standard Application Program is factory-loaded onto Matrix 400™. This program controls code reading, data formatting, serial port and Ethernet interfacing, and many other operating and control parameters.
MATRIX 400™ REFERENCE MANUAL 22 2 Ease of Setup Quick installation without PC by using X-PRESS™ interface for easy and intuitive setup Blue Diamonds™ aiming and focusing system Autom.
INTRODUCTION 23 2 Industrial Strength Industrial compact 2D reader Rugged full metal construction Sealed circular connectors IP67 protection class 50 °C max operating temperature .
MATRIX 400™ REFERENCE MANUAL 24 2 2.2 INDICATORS AND KEYPAD BUTTON Figure 19 - Indi cators The following LED indicators are located on the reader: NET yellow LED indicates connection to the on-board.
INTRODUCTION 25 2 2.3 ID-NET™ The ID-NET™ network is a built-in high-speed interface dedicated for high-speed reader interconnection. ID-NET™ is in addition to the Main and Auxiliary serial interfaces.
MATRIX 400™ REFERENCE MANUAL 26 2 ID-NET™ M/S Multidata: Multiple stations – single reader ID-NET™ interface allows connection of readers reading objects placed on independent conveyors. All readers are typically locat ed far away from each other and they use a dedicated presence sensor.
INTRODUCTION 27 2 7. Configure the other device parameters via VisiSet™ [Operating Mode, Calibration, Data Collection parameters, etc.]. 8. If using the CBX connection box equipped with a BM100 Backup module, perform Device Backup at the Slave. The Slave device is now Configured.
MATRIX 400™ REFERENCE MANUAL 28 2 2.4 X-PRESS™ HUMAN MACHINE INTERFACE X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of installation and maintenance.
INTRODUCTION 29 2 READY green green y ellow y ellow red SETUP FOCUS T ES T LEARN GOOD T RIGGER COM STATUS READY green green y ellow y ellow red SETUP FOCUS T ES T LEARN GOOD T RIGGER COM STATUS READY .
MATRIX 400™ REFERENCE MANUAL 30 2 Setup (Function 3) Onc e e nte re d, t he ima ge r a uto mat ic al ly p erf or ms Image Acquisition parameter calibration fo r the specific code presented to it. The Setup LED will blink until the procedure is completed.
INTRODUCTION 31 2 2.6 ACCESSORIES The following accessories can be used with the Matrix 400™ reader. Accessory Description Order No. Lenses LNS-1006 6 mm C-Mou nt Lens 93ACC1793 LNS-1109 9 mm C-Mou nt Lens 93ACC1794 LNS-1112 12.
MATRIX 400™ REFERENCE MANUAL 32 2 The following table shows the corr ect lens/illuminator combinations to be use d for Matrix 400™ imager assembly.
INTRODUCTION 33 2 Matrix 400™ assures the reading of deformed and / or overprinted codes, even though damaged or printed on high reflective surfaces (see Figures 22, 23, 24).
MATRIX 400™ REFERENCE MANUAL 34 2 Figure 26 - Dot Peening Marking on Metal Surface with Multi-dot per Code Element Figure 27 - Directly Marked Do t Matrix Code Characterized by Outstanding Separatio.
INTRODUCTION 35 2 2.8 EXTERNAL LIGHTING SYSTEMS In some direct part marking applications best reading results are obtained by using an external lighting system.
MATRIX 400™ REFERENCE MANUAL 36 2 The LT-210 Mini Spot Lighting System provides a high intensity light source designe d for the following applications: with uneven, noisy and scratched surfaces where dot peening or laser etching codes are directly marked onto metal surfaces or PCBs and need to be highlighted.
INTRODUCTION 37 2 The LT-316 60° Dark Field Ring Lighting System is designed for reading codes pr oduced by Dot Peening (especially by a 120° stylus) or Laser Etching on flat, reflective parts.
MATRIX 400™ REFERENCE MANUAL 38 2 The LT-511 Dome Lighting System is a diffuse dome light de signed for reading printed label or Direct Marking codes on parts with a curved surface.
INSTALLATION 39 3 3 INSTALLATION 3.1 PACKAGE CONTENTS Verify that the Matrix 400™ reader and all the parts supplie d with the equipment are present and intact when opening the packaging; the list of.
MATRIX 400™ REFERENCE MANUAL 40 3 3.2 MECHANICAL DIMENSIONS Matrix 400™ can be installed to operate in different positions. The twelve screw holes (M4 x 5) on the body of the reader are for mechanical fixture ( Figure 41). The diagra m below gives the overall dimensions of the reader and may be used for its installation.
INSTALLATION 41 3 4 [0.16] M4 [0.16] N°7 7 [0.28] 12.5 [0.49] 12.5 [0.49] 4.3 [0.17] 4.3 [0.17] 50 [1.97] 61 [2.40] = = 72.5 [2.85] 83.5 [3.29] = = 12.5 [0.49] 12.5 [0.49] 12.5 [0.49] 12.5 [0.49] 34 [1.34] 34 [1.34] 4.2 [0.17] Ø8 . 2 5 [ Ø0 . 3 2 ] 4.
MATRIX 400™ REFERENCE MANUAL 42 3 3.3 MOUNTING AND POSITI ONING MATRIX 400™ Using the Matrix 400™ mounting brackets you can obtain rotation on the various axes of the reader as shown in the diag.
INSTALLATION 43 3 Matrix 400™ is able to decode code labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting Matrix 400™, take into consideration these ideal label position angles: Pitch or Skew 10° to 20° and Tilt 0° .
MATRIX 400™ REFERENCE MANUAL 44 4 4 CBX ELECTRICAL CONNECTIONS All Matrix 400™ models can be connected to a CBX connection box through one of the available CAB-MSxx accessory cables. These accessory cables terminate in a 19-pin connector on the Matrix 400™ side and in a 25-pin male D-sub connector on the CBX side.
CBX ELECTRICAL CONNECTIONS 45 4 NOTE To avoid electromagnetic interference when th e reader is connected to a CBX connection box, verify the jum per positions in the CBX as indi cated in its Installation Manual.
MATRIX 400™ REFERENCE MANUAL 46 4 4.2.1 RS232 Interface The RS232 interface can be used for Point-to-Point, Pass Through or Master/Slave connections. When it is connected to the host computer it allows both transmission of code data and reader configuration by VisiSet™.
CBX ELECTRICAL CONNECTIONS 47 4 4.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-point connections over lon ger distances (max 1200 m / 3940 ft) than those acceptable for RS232 communications or in electrically noisy environments.
MATRIX 400™ REFERENCE MANUAL 48 4 4.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backw ard compatibility. We recommend using the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts. The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols.
CBX ELECTRICAL CONNECTIONS 49 4 Figure 55 - Matrix 400™ Multidrop Connection to a Multiplexer.
MATRIX 400™ REFERENCE MANUAL 50 4 4.3 ID-NET™ INTERFACE CBX100/500 Function Shield Network Cable Shield ID+ ID-NET™ network + ID- ID-NET™ network - REF Network Reference 4.3.1 ID-NET™ Cables The following instructions are referred to Figure 57, Figure 58 and Figure 59.
CBX ELECTRICAL CONNECTIONS 51 4 4.3.2 ID-NET™ Response Time The following figure shows the response time of the ID-NET™ network. This time is defined as the period between the Trigger activation and the beginning of data transmission to the Host.
MATRIX 400™ REFERENCE MANUAL 52 4 Figure 57 – ID-NET™ Netw ork Connections with isolated power blocks.
CBX ELECTRICAL CONNECTIONS 53 4 Figure 58 - ID-NET™ Netw ork Connections with Co mmon Power Branch Netwo rk.
MATRIX 400™ REFERENCE MANUAL 54 4 Figure 59 – ID-NET™ Netw ork Connections with Co mmon Power Star Network.
CBX ELECTRICAL CONNECTIONS 55 4 4.3.3 ID-NET™ Network Termination The network must be properly terminated in the first and last reader of the network.
MATRIX 400™ REFERENCE MANUAL 56 4 4.5 INPUTS There are two optocoupled polarity insensitive inputs available on the reader: Input 1 (External Trigger) and Input 2, a generic input: The External Trigger can be used in One Shot Mode or in Phase Mode.
CBX ELECTRICAL CONNECTIONS 57 4 EXTERNAL TRIGGER INPUT CONNECTIONS USING MATRIX 400™ POWER CAUTION Power is available directly to the Input Device, independently from the Power Supply Switch inside the CBX.
MATRIX 400™ REFERENCE MANUAL 58 4 CBX100/500 Function +V Power Source - Inputs I2 A Input 2 A (p olarity insensit ive) I2 B Input 2 B (p olarity insensit ive) -V Power Reference - Inputs INPUT 2 CON.
CBX ELECTRICAL CONNECTIONS 59 4 Pulled up to Ex ternal Input Device Pow er Input Signal Input Device Figure 67 - NPN Input 2 Using Ex ternal Power 4.6 OUTPUTS Two optocoupled general purpose outputs are available. The meaning of the two outputs Output 1 and Output 2 can be defined by the user.
MATRIX 400™ REFERENCE MANUAL 60 4 OUTPUT CONNECTIONS USING MATRIX 40 0™ POWER CAUTION Power is available directly to the Output Device, independently from the Power Supply Switch inside the CBX.
CBX ELECTRICAL CONNECTIONS 61 4 4.7 EXTERNAL LIGHTING SYSTEMS If an External Illuminator is used, it can be powered from the CBX connection box. It must be connected to the Vdc and GND terminal clamps. CAUTION Power is available directly to the Illuminator, independently from the Power Supply Switch inside the CBX.
MATRIX 400™ REFERENCE MANUAL 62 4 4.8 USER INTERFACE - HOST The following table contains the pinout for standard RS232 PC Host interface. For other user interface types please refer to their own manual.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 63 5 5 MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS 5.1 M16 19-PIN CONNECTOR The Matrix 400™ reader is equipped with an M16 19-pin male connector (Binder, 423 Series) for connection to the power supply, ser ial interfaces and input/output sign als.
MATRIX 400™ REFERENCE MANUAL 64 5 5.2 M12-D 4-PIN CONNECTOR (ETHERNET) In Matrix 400 xxx-x1x models, an M12 D-Co ded connector is provided for the on-board Ethernet connection. This interface is IEEE 802.3 10 BaseT and IEEE 802.3u 100 BaseTx compliant.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 65 5 5.4.1 RS232 Interface The RS232 interface can be used for Point-to-Point, Pass Through or Master/Slave connections. When it is connected to the host computer it allows both transmission of code data and reader configuration by VisiSet™.
MATRIX 400™ REFERENCE MANUAL 66 5 5.4.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-point connections over lon ger distances (max 1200 m / 3940 ft) than those acceptable for RS232 communications or in electrically noisy environments.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 67 5 5.4.3 RS485 Half-Duplex Interface NOTE This interface is provided for backw ard compatibility. We recommend using the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts. The RS485 half-duplex (3 wires + shield) inte rface is available for polled communication protocols.
MATRIX 400™ REFERENCE MANUAL 68 5 The figure below shows a multidrop configuration with Matrix 400™ readers connected to a Multiplexer. CA UTI ON This is an example of multidrop wiring. Consult the multiplexer m anual for complete wiring instructions.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 69 5 5.5 ID-NET™ INTERFACE Pin Name Function R ID+ ID-NET™ network + P ID- ID-NET™ network - L GND Ground 5.5.1 ID-NET™ Cables The following instructions are referred to Figure 83, Figure 84 and Figure 85.
MATRIX 400™ REFERENCE MANUAL 70 5 5.5.2 ID-NET™ Response Time The following figure shows the response time of the ID-NET™ network. This time is defined as the period between the Trigger activation and the beginning of data transmission to the Host.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 71 5 Figure 83 – ID-NET™ Netw ork Connections with isolated power blocks.
MATRIX 400™ REFERENCE MANUAL 72 5 Figure 84 - ID-NET™ Netw ork Connections with Co mmon Power Branch Netwo rk.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 73 5 Figure 85 – ID-NET™ Netw ork Connections with Co mmon Power Star Network.
MATRIX 400™ REFERENCE MANUAL 74 5 5.5.3 ID-NET™ Network Termination The network must be properly terminated by a 120 Ohm resistor at the first and last r eader of the network. 5.6 AUXILIARY RS232 INTERFACE The RS232 auxiliary interface is available for Point-to-Point, Pass Through or Master/Slave connections.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 75 5 5.7 ETHERNET INTERFACE (MATRIX 400 XXX-010 MODELS ONLY) The Ethernet Interface can be used for TCP/IP communication with a remote or local host computer by connecting the reader to either a LAN or directly to a host PC.
MATRIX 400™ REFERENCE MANUAL 76 5 5.8 INPUTS There are two optocoupled polarity insensitive inputs availa ble on the M16 19-pin connector of the reader: Input 1 (External Trigger) and Input 2, a generic input: The External Trigger can be used in One Shot Mode or in Phase Mode.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 77 5 EXTERNAL TRIGGER INPUT PNP PH-1 Vdc GND I1A I1B PNP PH-1 w ires Matrix 400™ B C L (brown) +10-30 Vdc (black) NO (blue) 0 V V CC ~ ~ + - A Figure 88 - Ex.
MATRIX 400™ REFERENCE MANUAL 78 5 Matrix 400™ EXTERNAL TRIGGE R Vext 30 Vdc max. A B Signal V V CC ~ ~ + - I1A I1B Figure 92 - External Trigger NPN Using Exte rnal Power Pin Name Function A Vdc Po.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 79 5 INPUT 2 CONNECTIONS USING EXTERNAL POWE R Matrix 400™ INPUT DEVICE Vext 30 Vdc max. D E V CC ~ ~ + - V Signal I2A I2B I in Figure 95 - Input PNP Using Ex ternal Power Matrix 400™ INPUT DEVICE Vext 30 Vdc max.
MATRIX 400™ REFERENCE MANUAL 80 5 The output signals are fully programmable being determined by the configured Activation/Deactivation events, Deactivation Timeout or a combination of the two. Refer to the Digital I/O folder in the VisiSet™ Help On Line for further details.
19-PIN CONNECTOR ELEC TRICAL CONNECTIONS 81 5 5.10 USER INTERFACE RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connect or Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7.
MATRIX 400™ REFERENCE MANUAL 82 6 6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations . However, they also require the correct setup of the software configuration parameters. Dotted lines in the figures refer to optional hardware configurations within the particular layout.
TYPICAL LAYOUTS 83 6 In this layout a single reader functions as a Slave node on a Fieldbus network. The data is transmitted to the Host through an accessory Fieldbus interface board installed inside the CBX500 connection box.
MATRIX 400™ REFERENCE MANUAL 84 6 6.2 PASS-THROUGH Pass-through mode allows two or more devices to be connected to a single external serial interface. Each reader transmits the messages received by the Auxiliary interface onto the Main interface. All messages will be passed through this chain to the host.
TYPICAL LAYOUTS 85 6 An alternative Pass-Through layout allows the more efficient ID-NET™ network to be used. This layout is really an ID-NET Master/Slave Mu ltidata layout which also allows each re.
MATRIX 400™ REFERENCE MANUAL 86 6 6.3 ID-NET™ The ID-NET™ connection is used to collect data from several readers to build a multi-point or a multi-sided reading system; there can be one master and up to 31 slaves connected together. The slave readers are connected together usin g t he ID-NET™ interface.
TYPICAL LAYOUTS 87 6 For a Master/Slave Multidata layout each reader has its own reading phase independent from the others; each single message is sent from the master reader to the Host computer.
MATRIX 400™ REFERENCE MANUAL 88 6 Alternatively, the Master reader can communicate to the Host as a Slave node on a Fieldbus network. This requires using an a ccessory Fieldbus interface board installed inside the CBX500 connection box.
TYPICAL LAYOUTS 89 6 6.4 RS232 MASTER/SLAVE NOTE This interface is provided for backw ard compatibility. We recommend using the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts.
MATRIX 400™ REFERENCE MANUAL 90 6 6.5 MULTIPLEXER NOTE This interface is provided for backw ard compatibility. We recommend using the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts. Each reader is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface through a CBX connection box.
TYPICAL LAYOUTS 91 6 6.6 ETHERNET CONNECTION (MATRI X 400 XXX-010 MODELS ON LY) For Matrix 400 XXX-010 models, the Ethernet connection is possible in two different layouts. In both layouts, before proceeding with the connection, it is necessary to configure the reader Ethernet parameters via VisiSet™.
MATRIX 400™ REFERENCE MANUAL 92 6 When using a Local Area Network (LAN), one or more Matrix 400 XXX-010s can be connected to the network by using CAB-ETH-M0x straight through cables: Figure 111 - Et.
READING FEATURES 93 7 7 READING FEATURES 7.1 OPTICAL ACCE SS ORY SELECTION Referring to Figure 112 and the formula below, use the data in the following table to calculat e the FOV for your application. Model Lens Viewing Angle Horizontal Viewing Angle Vertical Viewing Angle Diagonal Min Focus Distance mm LNS-1109 9 mm 48.
MATRIX 400™ REFERENCE MANUAL 94 7 Example: The FOV for a Matrix 400 600-0x0 base using the 16 mm lens at a focus distance of 200 mm is: FOV H = 2 [(200 mm + 35 mm) tan (24°/2)] = 100 mm FOV V = 2 [(200 mm + 35 mm) tan (18°/2)] = 74 mm 7.2 HORIZONTAL FOV VS.
READING FEATURES 95 7 7.2.2 1D (Linear) Codes 1D Codes – Matrix 400 400-0x0 (SXGA) 9 mm, 12.5 mm, 16 mm 0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Reading Distance (cm) Horizontal FOV (cm) SXGA - 9 mm SXGA - 12.5 mm SXGA - 16 mm 0.
MATRIX 400™ REFERENCE MANUAL 96 7 9 mm, 12.5 mm, 16 mm 0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 Reading Distance (cm) Horizontal FOV (cm) UXGA - 9 mm UXGA - 12.5 mm UXGA - 16 mm 0.15 0.25 0.
READING FEATURES 97 7 7.2.3 2D (Bi-dimensional) Codes 2D Codes – Matrix 400 400-0x0 (SXGA) 9 mm, 12.5 mm, 16 mm 0 5 10 15 20 0 5 10 15 20 25 30 35 Reading Distance (cm) Horizontal FOV (cm) SXGA - 9 mm SXGA - 12.5 mm SXGA - 16 mm 0.25 0.20 0.33 0.38 0.
MATRIX 400™ REFERENCE MANUAL 98 7 2D Codes – Matrix 400 600-0x0 (UXGA) 9 mm, 12.5 mm, 16 mm 0 5 10 15 20 25 0 5 10 15 20 25 30 35 40 45 50 55 Reading Distance (cm) Horizontal FOV (cm) UXGA - 9 mm UXGA - 12.5 mm UXGA - 16 mm 0.15 0.25 0.20 0.20 0.25 0.
READING FEATURES 99 7 7.3 MAXIMUM LINE SPEED AND EXPO SURE TIME CALCULATIONS The Exposure Time (or Shutter ) parameter defines the time during which the image will b e exposed to the reader sensor to be acquired. This parameter depends heavily on the environmental conditions (external lighting system, image contrast etc.
MATRIX 400™ REFERENCE MANUAL 100 7 T exp (max) and LS (max) are represented in the graph below as the curved line for X (code resolution). Values above the curve result in blurring. In practice, the application values are somewhere below the theoretical line, (in the green area), due to environmental a nd other conditions.
READING FEATURES 101 7 Line Speed T exp SW Limit X 2X Convey or Spee d Limit Readable Blurring T exp (min) SW/HW Limit T exp (min) is the minimum Exposure Time value obtainable f or the specific application.
MATRIX 400™ REFERENCE MANUAL 102 8 8 SOFTWARE CONFIGURATION Software configuration of your Matrix 400™ for static reading or simple code reading applications can be accomplished by the Rapid Confi.
SOFTWARE CONFIGURA TION 103 8 8.3 STARTUP After completing the mechanical and electrical connections to Matrix 400™, you can begin software configuration as follows: 1. Power on the Matrix 400™ reader. Wait for the reader startup. The system bootstrap requires a few seconds to be completed.
MATRIX 400™ REFERENCE MANUAL 104 8 8.3.1 VisiSet™ Options The Options item from the VisiSet™ menu (see Figure 113) presents a window allowing you to configure: the logging function ( Log ) .
SOFTWARE CONFIGURA TION 105 8 Figure 116 - Options – Commu nication: Serial Port Figure 117 - Options – Commu nication: Ethernet.
MATRIX 400™ REFERENCE MANUAL 106 8 8.4 CONFIGURATION Once connected to Matrix 400™ as described in par. 8.3, you can modif y the configuration parameters as follows: 1.
SOFTWARE CONFIGURA TION 107 8 8.4.1 Edit Reader Parameters The Parameter Setup window displays the configuration parameters grouped in a series of folders. Each parameter can be modified by selecting a different item from the prescribed list in the box , or by typing new values directly into the parameter box .
MATRIX 400™ REFERENCE MANUAL 108 8 Parameters to verify/modify: Operating Mode Sets the parameters which customize the rea der operating mode starting from three main modes: One Shot: acquires a si ngle image based on the selected value for the Acquisition Trigger and Acqui sition Trigger Delay.
SOFTWARE CONFIGURA TION 109 8 When all the configuration parameters are set correctly, save them to the Matrix 400™ reader by pressing the Send button.
MATRIX 400™ REFERENCE MANUAL 110 8 Environmental Parameters regard the device Identity and Position in a Network (ID-NET™, Master/Slave RS232, MUX 32, Ethernet) and are not influenced by the "Send Default Configuration" and "Send Configuration" commands.
SOFTWARE CONFIGURA TION 111 8 For device replacement it is necessary to se nd the previously saved configuration (both Configuration and Environmental parameters) to the new device.
MATRIX 400™ REFERENCE MANUAL 112 8 8.4.3 Calibration VisiSet™ provides a Calibration Tool to maximize the reading performance by tuning the acquisition parameters and the time of the delayed triggers.
SOFTWARE CONFIGURA TION 113 8 The following examples show some of the typical conditions occurring during the inst allation: Under-exposure: To correct this result it is recommended to change the following parameters in their order of appearance: 1. increase the Exposure Time 2.
MATRIX 400™ REFERENCE MANUAL 114 8 Over-exposure: To correct this result it is recommended to change the following parameters in their order of appearance: 1.
SOFTWARE CONFIGURA TION 115 8 Moving code out of the Field of View: To correct this result and have the code completely visible in F.O.V., it is possible to follow one or both the procedures listed be.
MATRIX 400™ REFERENCE MANUAL 116 8 8.4.4 Multi Image Acquisition Settings When controlled variable conditions occur in the application, Multiple Image Acquisition Settings (up to 10), can be defined to create a database of parameter groups tha t handle each specific application condition.
SOFTWARE CONFIGURA TION 117 8 8.4.6 Region Of Interest Windowing In order to satisfy very high throughput applications, higher frame rates can be achieved using the powerful Region Of Interest Windowing parameters in the Calibration parameter setup menu.
MATRIX 400™ REFERENCE MANUAL 118 8 8.4.7 Direct Part Marking Applications Decoding Method: Direct Marking For DataMatrix and QR code the Decoding Method parameter selects the decoding algorithm according to the printing/marking technique used to create the symbol and on the overall printing/marking quality.
SOFTWARE CONFIGURA TION 119 8 Image Filter Sets the filter to be applied to the image before being processed. This parameter can be used to successfully decode particular ink-spread printed codes (ex. direct part mark codes). A different filter can be applied to each Image Acquisition Setting .
MATRIX 400™ REFERENCE MANUAL 120 8 8.5 IMAGE CAPTURE AND DECODING By using the Capture Image and Decode La st Image functions from the VisiSet™ Main menu, you can get info rmation about the image decod able codes in terms of Symbology, encoded Data, Position and Orientati on, Decode Time and Code Quality Assessmen t Metrics.
MAINTENANCE 121 9 9 MAINTENANCE 9.1 CLEANING Clean the reading window (see Figure A, 1) periodically for continued correct operation of the reader. Dust, dirt, et c. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments.
MATRIX 400™ REFERENCE MANUAL 122 10 10 TROUBLESHOOTING 10.1 GENERAL GUIDELINES When wiring the device, pay careful attention to the signal name (acronym) on the CBX100/500 spring clamp connectors (chp. 4). If you are connecting directly to the Matrix 400 ™ M16 19 -pi n c onn ect or pay attention to the pin number of the signals ( chp.
TROUBLESHOOTING 123 10 TROUBLESHOOTING GUIDE Problem Suggestion One Shot or Phase Mode using serial trigger source: the ”TRIGGER” LED is not blinking. In the Operating Mode folder check the settings for Reading Phase-ON, Acquisition Trigger and Reading Phase-OFF parameters.
MATRIX 400™ REFERENCE MANUAL 124 10 TROUBLESHOOTING GUIDE Problem Suggestion are incorrect, corrupted or incomplete. In VisiSet Communication folder check the settings of Header and Terminator String parameters. In VisiSet™ Data Collection folder, check the settings of DATA FORMAT parameter group.
TECHNICAL FEATURES 125 11 11 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Voltage 10 to 30 Vdc Power Consumption 0.8 to 0.27 A, 8 W max.; 0.5 to 0.
MATRIX 400™ REFERENCE MANUAL 126 11 SOFTWARE FEATURES Readable Code Symbologi es 1-D and stacked 2-D POST AL PDF417 Standard and Micro PDF417 Code 128 (EAN 128) Data Matrix ECC 200 (Stan.
127 GLOSSARY AIM (Association for Automatic Identification and Mobility): AIM Global is the international trade association representing automatic identificat ion and mobility technology solution providers.
128 Depth of Field The difference between the minimum and the maximum distance of the object in t he field of view that appears to be in focus. Diffused Illumination Distributed soft lighting from a wide variety of angles used to eliminate shadows a nd direct reflection effects from highly reflective surfaces.
129 ISO (International Organization for Standardization): A network of the national standards institutes of several countries produ cing world-wide industrial and commercial standards. LED (Light Emitting Diode) A low power electronic light source commonly used as an indicator light.
130 INDEX A Accessories, 31 Application Examples, 32 Auxiliary RS232 Interface, 55, 74 C Calibration, 112 CBX Electrical Connections, 44 Compliance, vii E Edit Reader Parameters, 107 Electrical Connec.
DECLARATION OF CONFORMITY 08 Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät decla.
www .automation.datalogic.com.
Een belangrijk punt na aankoop van elk apparaat Datalogic Scanning 400 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Datalogic Scanning 400 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Datalogic Scanning 400 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Datalogic Scanning 400 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Datalogic Scanning 400 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Datalogic Scanning 400 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Datalogic Scanning 400 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Datalogic Scanning 400 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.