Gebruiksaanwijzing /service van het product RMC-120 van de fabrikant Datavideo
Ga naar pagina of 28
2005/1/4 Ethernet Control Box for SE-800 RMC-120 錯誤 ! USER MANUAL Http://www.datavideo-tek.com.
1 Warnings and Precautions 1. Read all of these warnings and save them for later reference. 2. Follow all warnings and instructions ma rked on this unit. 3. Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol clea ners.
2 11. Never push objects of any kind into this unit throug h the cabinet ventilation slots, as they may touch dangerou s voltage points or short out parts that cou ld result in risk of fire or electric shock. Never spill liquid of any kind onto or into this unit.
3 Table of Contents Warnings and Precautions …... …... …... …... …... …... …... …..1 Warnings and Precautions What's in the Box ……………..……….………………...…...……….4 Introduction …………………………………….
4 What’s in the box? 1. RMC-120 2. AC / DC Power Adaptor * 1 3. RJ45 Ethernet cable 1M * 1 (cross ove r) 4. RS-232 cable 1.2M * 1 5. User ma nual 6. Installation CD.
5 Introduction Thank you for purchasing Datavideo’s RMC-1 20. RMC-120 is one of SE-800 accessories, which can b e used to remote control SE-800 via RS-232 command with a simple, b ut unique operate control interface. You will be amazed a nd pleased at what you can do with this advanced piece of technology.
6 Features Standard RJ 45 and RS-232 connectors Easy to install Simply connection Full functions remote control Friendly user interface.
7 User Interface Functions 1. Joy stick and mode selector 2. Voice sync adjustment 3. Video input forma t selector 4. Audio channel selectors 5. Audio follo w video s witch 6. Color processor 7. Border control 8. Background c ontrol 9. Transition source selectors 10.
8 1. Joysti ck and Joysti ck mode sele ctor: The Joysti ck control can function either in RGB Color Co rrection mode or Position Control mode, depending on the position of the selector below it. In RGB Correction mode, you ca n make real time RGB white balance corrections to the Main Source video.
9 selected on the Main Sou rce bus is automat ically selected. If A+V is not engaged, the input source is user selectable. Level controls for each input source are the rotary pots below the selection buttons.
10 7. Border: controls the border style and color for the Picture in Picture effect. This cont rol is accessible when the Picture in Picture controls, Wipe and Zoom effects. ( 22. ) are engaged. 8. Background: when Background is selected in either the Main or Sub Video Source ( 14, 15.
11 14. Main Video Source Selector: used to select which of the four video input channels or background is sent to the Main video output. 15. Sub Video Source Selector: used to select which of the four video input channels or background will be transiti oned to or used as a sub source in an effect.
12 19. Paint: when engaged (and the Paint LED is lit), this applies a posterized effect to the sele cted Main Video Source. Repeated presse s of the up and down buttons set the intensity le vel of the effect, from 1 (least) to 4 (most). The level setting is displayed in the Effects window above t he Keypad ( 21.
13 23. Audio Bus selectors: the LE Ds indicate whi ch of the audio inputs are active in the Main audio output mix. Press the button to either include or exclude the chann el. The left button, labeled Mic/Aux, can be set to either Mic, Aux, or off. Above all are basic functions description s.
14 Installation, Connections, Set up Connections SE-800 Real Panel Computer Real Panel RS-232 RMC-120 RS-232 Cable Ethernet HUB Ethernet Cable.
15 Set up PC Computer IP address Step 1: Click “Start” button. Go to “Setting”, then click on “Control Panel” Step 2: Click on “N etwork and Dial-up Connections”.
16 Step 3: Click on “Properties” Step 4: Select “Internet Protocol (TCP/IP)”, click on “Properties”.
17 Step 5: Set up IP address and Subnet mask. IP address: 192.168.0.1 Subnet mask: 255.255.255.0.
18 Set up RMC-120 IP address Step 1: Double click or Config Icon Step 2: Click on the Search Buttion Step 3: clink on the MAC List.
19 Step 4: Setting the Local IP: 192.168.0.7 Setting the Subnet Mask : 255.255.255.0 Setting the Remote IP: 192.168.0.1 Setting the Baud Rate: 57600 Setting the Data Bit: 8 Setting the Stop Bit: 1 Set.
20 Set up SE-800 IP address Step 1: Clink on the se800 icon Step 2: Right Click on the mouse button and select “Options”.
21 Step 3: Select “Client Mode” and set up Remote IP 192.168.0.7 then Click on the “OK” button.
22 Trouble shooting 1. “Connect failed” error message. Please check your PC Computer IP address settings again, and be su re it has been set up properly. IP address: 192.168.0.1 Subnet mask: 255.255.255.0 RMC-120 IP address setti ngs assigned Condition Setting the Local IP: 192.
23 FAQ 1. Q: When I select BACKGROUND, the “ON” button starts blinking. Sometimes it will speed up, but sometimes it will slow down. Is it normal? A: Yes, it’s normal, and it will not affect the performance. 2. Q: When I use GPI control, occasionally the “PLAY” key will turn on in SE-800 switcher.
24 A: For the ROM B, please make sure all the video effects and transition effects have turned off. Then, press up key and check the check the digital numbe r which show s on “EFFECT” and “SPEED” if it’s showing 2.
25 Specifications RS-232 Data Control Port Connecting Datavideo SE-800 RS-232 Remote Control Port RJ-45 Ethernet Port Connecting PC or Laptop Ethernet Port for Remote Trigger Control Dimensions W x D x H 100m/m x 67m/m x 23m/m Weight 0.12 Kg Power Input: DC 9V/0.
26 Tech support Datavideo maintains five offices worldwide to sup port this and other products. Datavideo Technologies Co., LTD. 10F, No. 176, Jian-Yi Rd, Chung Ho City, Taipei Hsien 235, Taiwa n R.O.C. Tel: 886-2-8227-2888 Email: info@datavideo.com.tw Datavideo Corporation USA 12300-U East Washington Blvd.
27 Datavideo UK Limited Unit 2 Waterside Business Park Manchester, England Tel: +44(0) 1457 851000 Email: sales@datavideo.co.uk P/N: All the trademarks are the properties of their respec tive owners. Datavideo Technologies Co., Ltd. All rights reserved 2004.
Een belangrijk punt na aankoop van elk apparaat Datavideo RMC-120 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Datavideo RMC-120 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Datavideo RMC-120 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Datavideo RMC-120 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Datavideo RMC-120 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Datavideo RMC-120 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Datavideo RMC-120 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Datavideo RMC-120 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.