Gebruiksaanwijzing /service van het product VN600BA van de fabrikant Desa
Ga naar pagina of 20
Save this manual for future reference. BLUE FLAME VENT -FREE NA TURAL GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL VN600BA 6000 Btu/Hr Manually- Controlled Models WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal in- jury, or loss of life.
2 104271 BLUE FLAME NA TURAL GAS HEA TER ® Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced.
3 104271 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 104271 BLUE FLAME NA TURAL GAS HEA TER ® Confined and Unconfined Space The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.
5 104271 OWNER’S MANUAL WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.
6 104271 BLUE FLAME NA TURAL GAS HEA TER ® Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12&qu.
7 104271 OWNER’S MANUAL Figure 5 - Mounting Screw Locations Mounting Screw Locations 8 7 / 8 " Minimum To Maintain 6" Clearance From Wall 7 3 / 4 " 20 1 / 4 " Minimum To Maintain 3" Clearance From Floor FLOOR JOINING W ALL INSTALLING HEATER TO WALL Marking Screw Locations 1.
8 104271 BLUE FLAME NA TURAL GAS HEA TER ® Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater. Attaching To Wall Stud Method For attaching mounting screw to wall stud 1.
9 104271 OWNER’S MANUAL * A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessory , page 18.
10 104271 BLUE FLAME NA TURAL GAS HEA TER ® CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
11 104271 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. T ur n control knob clockwise Clockwise to the PILO T position. 2. Press in contr ol knob and turn clock- wise Clockwise to the OFF position. Shutting Off Burner Only (pilot stays lit) Turn control knob clockwise Clockwise to the PILOT position.
12 104271 BLUE FLAME NA TURAL GAS HEA TER ® INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple.
13 104271 OWNER’S MANUAL Continued TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. POSSIBLE CAUSE 1. Ignitor cable pinched or wet 2. Ignitor electrode not connected to igni- tor cable 3.
14 104271 BLUE FLAME NA TURAL GAS HEA TER ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner com.
15 104271 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
16 104271 BLUE FLAME NA TURAL GAS HEA TER ® 12-2 12-1 ILLUSTRA TED PA R T S BREAKDOWN VN600BA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 17 18 21 22 25 20 24 23 19 26 27 16.
17 104271 OWNER’S MANUAL P AR TS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
18 104271 BLUE FLAME NA TURAL GAS HEA TER ® Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
19 104271 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com 104271-01 Rev. D 03/00 Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice.
Een belangrijk punt na aankoop van elk apparaat Desa VN600BA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa VN600BA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa VN600BA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa VN600BA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa VN600BA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa VN600BA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa VN600BA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa VN600BA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.