Gebruiksaanwijzing /service van het product R510 van de fabrikant DeWalt
Ga naar pagina of 82
Technical Guide Dell Product Name Dell PowerEdge R510 Name Excellent balance of internal storage, redundancy, and value in a compact cha ssis.
Dell PowerEdge R510 T echnic al Guide 2 This documen t is for info rmationa l purposes only. Dell reserves the right to make changes without further notice to any products herein. The content provided is as is and without express or implied w arrantie s of any kind.
Dell PowerEdge R510 T echnic al Guide 3 Table of Contents 1 Overview ........................................................................................................ 7 1.1 Product Descriptio n ..................................................
Dell PowerEdge R510 T echnic al Guide 4 4.14 Field Replaceable Units (FRU) ........................................................................ 35 5 Power, Therma l, Acoust ic .......................................................................
Dell PowerEdge R510 T echnic al Guide 5 10.2.3 PCI Card Dim ensions ............................................................................. 55 11 Storage ...........................................................................................
Dell PowerEdge R510 T echnic al Guide 6 Table 27. Microso ft Operating Sy stems Supp orted ................................................................... 65 Table 28. Linux Operat ing System s .....................................................
Dell PowerEdge R510 T echnic al Guide 7 1 Overv iew 1.1 Product Description The PowerEd ge™ R510 is a 2 -socket, 2 U high-capacit y, multi-purpose rack server offe ring an exc ellent balance of interna l storage, redundancy, and value in a compact chassis .
Dell PowerEdge R510 T echnic al Guide 8 comprehensive set of provisi oning functio ns such as syst em deploymen t, system updates, hardw are configuratio n and diagnostics from a single intuitive in terface called Unifi ed Server Co nfigurator ( USC) in a pre-OS environment .
Dell PowerEdge R510 T echnic al Guide 9 1.2 Product Comparison Table 1 provides a de tailed compa rison of Power Edge Server feat ures using new, current, and p red ecessor models.
Dell PowerEdge R510 T echnic al Guide 10 PowerEdge 295 0 III (Predecessor) PowerEdge R710 (Current) PowerEdge R510 (New) DIAGNOSTIC LCD LCD LED for PowerEdge R5 10- 4 and R510- 12 LCD for PowerEdg e R 510-8 MANAGEMENT BMC+DRAC 5 iDRAC 6 Express Optional iDRAC6 E n terprise and vFlash BMC, IPMI 2.
Dell PowerEdge R510 T echnic al Guide 11 2 New T echnologies A number of new techn ologi es have been incorpo rated into the Po werEdge R510 product , including: Intel 5500 chipset + Inte l Xeon p.
Dell PowerEdge R510 T echnic al Guide 12 Chipset. 2.2.1 PCIe Generat ion 2 PCIe Gen 2 provide s the next generatio n of I/O bandw idth to the system. P CIe Gen2 doub les the signali ng bit rate of each lane f rom 2.
Dell PowerEdge R510 T echnic al Guide 13 3 System Overv i ew PowerEdge R510 provi des a value 2S 2U server, w ith maximized storage capacity, high performa nce, simplified m anagement , and an affordable price .
Dell PowerEdge R510 T echnic al Guide 14 PowerEdge R510 – 4 dr ives PowerEdge R510 – 8 drives PowerEdge R510 -12 drives Dimension (HxWxD) 3.40 x 17.19 x 24. 09 (in); 86.4 x 436 . 6 x 610.2 (mm) 3.42 x 17.53 x 26. 17 (in); 86.7 x 445 . 2 x 664.6 (mm) Max Weight 16 Kg/35.
Dell PowerEdge R510 T echnic al Guide 15 PowerEdge R510 – 4 dr ives PowerEdge R510 – 8 drives PowerEdge R510 -12 drives HDD/SSD NA 2.5" (in hard drive ca r rier t hr ough conversion kit) 25GB SATA SSD 50GB SATA SSD 100GB SATA SSD 2.5" (in hard drive ca r rier through conversion kit) 25GB SATA SSD 3.
Dell PowerEdge R510 T echnic al Guide 16 PowerEdge R510 – 4 dr ives PowerEdge R510 – 8 drives PowerEdge R510 -12 drives NICs/Single Port Broadcom NetXtreme II 5710 Single Port 10 GBase-T Ethernet .
Dell PowerEdge R510 T echnic al Guide 17 PowerEdge R510 – 4 dr ives PowerEdge R510 – 8 drives PowerEdge R510 -12 drives Linux: RHEL 4.7 ES/AS x86 ( DIB) RHEL 4.7 ES/AS 64 -bit(DIB) RHEL 4.7 for HPC x86 -64 (DIB) RHEL 5.3 Standar d/AP x86(DIB) RHEL 5.
Dell PowerEdge R510 T echnic al Guide 18 4 Mechanical 4.1 Chassis Description PowerEdge R510 chass is is a 2U rack syst em. The chass is is not sw appable . Suppo rted configuratio ns are detailed in Table 3. Table 3. Supported C hassis Conf igurat ions 4-HDD Configuration 8-HDD Configuration 12 -HDD Configuration 5 x cabled 3.
Dell PowerEdge R510 T echnic al Guide 19 Figure 3. System Dimension s.
Dell PowerEdge R510 T echnic al Guide 20 4.3 Front Panel View and Features Figure 4. PowerEdge R510 – 4 HDD Confi guration Figure 5. PowerEdge R510 – 8 HDD Confi guration.
Dell PowerEdge R510 T echnic al Guide 21 Figure 6. PowerEdge R510 – 1 2 HDD Confi guration 4.3.1 NMI Button The Non-Maskabl e Interrupt (NMI) but ton can be accessed thro ugh a pin h ole with a thin o bject (e.g., the end of a paperclip) . Pressing this butt on results in a Non-Maskable Interr upt to the CPU, which h alts all CPU operations .
Dell PowerEdge R510 T echnic al Guide 22 The Power LED ha s two st ates: • Power LED is OFF: System is not operat ing, regardless of AC presen t . (Other AUX powered subs ystems may be operat ional wit h AC power present. ) • Power LED is O N (Green): System is operatin g.
Dell PowerEdge R510 T echnic al Guide 23 This hierarchy dicta tes that connections tha t are lower in the hierarchy b e disabled anytime a higher level connection is disa bled . 4.3.6 DVD/CD If present, the DVD/CD drive has an eject m echanism and a green activit y LED .
Dell PowerEdge R510 T echnic al Guide 24 4.4 Back Panel View and Features Figure 9. R510 with Non-Redu ndant Power Su pply for Power Edge R510-4 ONLY Figure 10.
Dell PowerEdge R510 T echnic al Guide 25 Figure 12. Redundant PSU Status ligh ts provide indicatio ns as follows: Not lit : AC power is not co nnected. Green : In stan dby mode, a green light indi cates that a valid AC source is connected to the power supply an d that the power sup ply is operational.
Dell PowerEdge R510 T echnic al Guide 26 4.6 Internal Chassis Views Figure 15. PowerEdge R510-4 : Non-Redu ndant PSU and the Battery Holder for PERC Card Figure 16.
Dell PowerEdge R510 T echnic al Guide 27 Figure 17. PowerEdge R510- 12 Internal Vi ew (Redund ant PSU with PD B and Addition al Fan for PSU) Figure 18.
Dell PowerEdge R510 T echnic al Guide 28 4.7 Rails and Cable Management ReadyRails TM Slidin g Rails for 4-post Rack s support: Tool less installat ion in 19‖ EIA - 310 -E compliant square or un.
Dell PowerEdge R510 T echnic al Guide 29 4.8 Ra il View Figure 19. R510 Sliding Rails wit hou t CMA Figure 20. R510 Sliding Rails wit h CMA.
Dell PowerEdge R510 T echnic al Guide 30 Figure 21. R510 Static Rails Figure 22. R510 Static Rails in Rack 4.9 Fans 4.9.1 Fan module PowerEdge R510-4 and P owerEd ge R510-8 ha ve the sa me fan module .
Dell PowerEdge R510 T echnic al Guide 31 Figure 23. Fan Module for R510 -4 and 8 PowerEdge R510- 12 has redundant fa ns stacked in modu les. Figure 24. Fan Module for R510 - 12 4.9.2 Fan Location and Ins tallation PowerEdge R510-4 has f our fan modu les (it does not have the fan circled in red as shown in Figur e 25) .
Dell PowerEdge R510 T echnic al Guide 32 Figure 25. Fan Location 4.9.3 Fan Connector and Connector Locat ions Figure 26. Fan Connector Locat ions.
Dell PowerEdge R510 T echnic al Guide 33 4.10 Cabling Table 8. Cabling Informati on Chassis Controller Note PowerEdge R510 -4 No Add-in RAID co ntroller C0, C1 S100 C2A, C2B, C3, C4, C5 S300 Include d.
Dell PowerEdge R510 T echnic al Guide 34 4.11.2 Hard Drive Se curity Hard drives are o nly acces sible by unlockin g and opening the bezel. 4.11.3 Intrusion Sw itch The intrusio n switch is located inside the chass is under the top cover . T he swit ch alarms if the top cover is opened while the power is on .
Dell PowerEdge R510 T echnic al Guide 35 The PowerEd ge R510-12 interna l USB connectors a re on the backplane as show n below. Figure 29. PowerEdge R510 – 1 2 USB Connector 4.
Dell PowerEdge R510 T echnic al Guide 36 5 P ower , Thermal, Acoustic 5.1 Power Supplies The 4-HDD configu ration includes a 48 0W po wer supply . The 8- and 12-HDD configuration s have a hot-plug redundant 1100 W power supply . A h ot -plug redund ant 750W opt ion is available for the 8- and 12 -HDD configuratio n s.
Dell PowerEdge R510 T echnic al Guide 37 Figure 31. Connector (8 pi ns) 5.2 Thermal Optimized the rmal managem ent makes P owerEdge R510 cool an d quiet.
Dell PowerEdge R510 T echnic al Guide 38 Table 9. Operating /N on - Operating (S t orage) Requireme nts Operating Requirem ents Non-Operating R eq uirements Temperature Rang es (For Altitude ≤90 0 m or 2952.75 ft) 10 to 35 ° C (50 to 95 ° F) -40 to 65 ° C (-40 to 149 °F ) Temperature Rang es (For Altitude > 90 0 m or 2952.
Dell PowerEdge R510 T echnic al Guide 39 5.6 Acoustics The acoustical design of the PowerEdge R510 reflects the following: Adherence to Dell’s high sound quality standards. Sound qualit y is different from sound power level and sou nd pressure level in that it describes how h umans respond to annoyances i n sound, like whistles, hums, etc.
Dell PowerEdge R510 T echnic al Guide 40 Table 10. Acoustics of 4-HD D Chassis Typical Confi guration @ 23 ± 2 °C Operating Mode L WA - UL (Bels) L pA (dBA) PROMINENT TONES CPU HDD RAID DIMM 2 x Intel E5506/2.13GHz 2 x 146GB SAS (3.5‖/ 7200 RPM) 1 x PERC S300 4 x 2GB UDIMM Standby 2.
Dell PowerEdge R510 T echnic al Guide 41 Definitions Standby: AC Power i s connecte d to Power Supply Units but syste m i s not turned on. Idle: Reference ISO7 779 (1999) definition 3.1.7; system is r unning in its OS but no other s peci fic activity.
Dell PowerEdge R510 T echnic al Guide 42 6 Processors R510 can operate in ei ther single-processo r or dual-pro cessor mode. Ho wever, since the memory cont roller is embedded in the processo r, when .
Dell PowerEdge R510 T echnic al Guide 43 7 Memory 7.1 Overview Please carefully review this en tire section Features of th e PowerEdge R510 me mory include : • 3 channels per process or • Support for regist ered ECC DD R3 DIMMs or Unbuf fered ECC DD DR3 DIMMs.
Dell PowerEdge R510 T echnic al Guide 44 8 Chipset 8.1 Overview Introduction of th e new Intel Xe on processor 5600 series includes a st epp ing revision of th e Intel 5520 and 5500 chipset, whi ch is requ ired to enable th e full 5600 series fea ture set.
Dell PowerEdge R510 T echnic al Guide 45 8.2.3 PCI Expres s* Interfa ces PCI Express* Interfa ces include: • Intel 5500 chipset IOH provides m ultiple PCI Expr ess* Gen 2 interfaces • Point- to -p.
Dell PowerEdge R510 T echnic al Guide 46 9 BIOS 9.1 Overview A flash resides on the SPI bus for BIOS and configu ration storage . A 32 Mbit device is used for this function . Th is permits the BIOS to be upgraded in the field via a bo ota ble device rather than by physically removing an EEPROM.
Dell PowerEdge R510 T echnic al Guide 47 AC recovery stagg er ing Power- Up Power Inventory (PSU , CPU, and DIMM mis match checking) Support for Multiple power profiles Static Maximum Pe r formance Mod e OS Control(DBS ) Active Power Contro ller Custom 9.
Dell PowerEdge R510 T echnic al Guide 48 Table 15. Summary of Power Management F eatures Feature Type Enable/Status/ Ctr l bit location Description ACPI Mode Switch Fixed ICH- 10 The OS uses the SC I_EN bit in ICH to switch f r om legacy mode to ACPI mode.
Dell PowerEdge R510 T echnic al Guide 49 Table 16. Supported Power Profiles Static MAX Performance DBPM Disabled ( BIOS sets P-State to MAX ) Memory frequency = Maximum Performa n ce Fan algorithm = P.
Dell PowerEdge R510 T echnic al Guide 50 9.3 UEFI and ACPI For PowerEdge R510 systems, the UEFI layer does not participate in generation of the ACPI (Advanced Configuratio n and Power Interface ) tabl e. The ACP I table is generated b y the BIOS and UEFI exposes the ACPI table as an EF I configura tion table ent ry.
Dell PowerEdge R510 T echnic al Guide 51 Table 18. Intel 5600 Chi pset P-State Projection s and Tur bo Mode Frequen cy Processor QDF# Frequency (GHz) P-state Turbo Mode Freq (Ghz) Step- ping E5503 Q2HH 2.00 Pmin+3 n/a D0 E5506 Q1GL 2.13 Pmin+4 n/a D0 E5507 Q2HG 2.
Dell PowerEdge R510 T echnic al Guide 52 Table 19. UEFI Summary UEFI IS UEFI IS NOT Compliant with UEF I specification 2 . 1 A layer on top of t h e existing legacy BIOS Independent of proc essor and chipset technology.
Dell PowerEdge R510 T echnic al Guide 53 10 I/O Slots 10.1 Overview The PowerEd ge R510 system provi des two configu rations for I/O slot s: Riser 1 (default off ering) : Three PCIe slots (x4, x4,.
Dell PowerEdge R510 T echnic al Guide 54 10.1.2 PCI Device Informa tion • IOH port 1, 2 (PCI Exp res s Gen2 x4) – Broadcom BCM5716 Gi gabit LOM • IOH port 3 (PCI E xpress Gen2 x4) – Sl ot 4 .
Dell PowerEdge R510 T echnic al Guide 55 Table 22. Riser 2 Slot Informat ion Bandwidth Slot Location Height Length Slot1 (Gen2) PCIe x16 PCIe x16 Full Height Half Length Slot2 (Gen2) PCIe x4 PCIe x8 F.
Dell PowerEdge R510 T echnic al Guide 56 11 Stor age 11.1 Overview There are two types of cha ssis for R510. • 4 Hard Drive Chassis: x cabl ed 3.5 ‖ HDD (cabled HD D carrier, identical t o R410 cabled HDD ca rrier), support one sl im optical disk drive (ODD) • 8 Hard Drive Chassis : 8 x ho t-swap 3.
Dell PowerEdge R510 T echnic al Guide 57 11.3 RAID Configurations Table 24. Raid Confi guration s for the PowerEdge R5 10-4 PowerEdge R510 -4 Factory Configuration No Mixed HDD (3.
Dell PowerEdge R510 T echnic al Guide 58 Table 25. Raid Confi guration s for the PowerEdge R5 10-8 PowerEdge R510 -8 Factory Configuration No Mixed HDD (Must be all 2.
Dell PowerEdge R510 T echnic al Guide 59 R510 -8 Mixed HDD (SAS + S ATA) Factory Config uration Mixed SAS + SATA (Must be all 3.5" HDDs) (ex. Min 2x SAS + 2x SATA; Max 2x SAS + 6 SATA) Type # Nam.
Dell PowerEdge R510 T echnic al Guide 60 Table 26. RAID Configurat ion for Power Edge R510-12 Factory Configuration No Mixed HDD (Must be all 2.5" or 3.
Dell PowerEdge R510 T echnic al Guide 61 53 ASSR1/R1-X RAID1+RAID1 (PERC H2 00, PERC H700) 2 + 2 2 + 2 54 ASSR1/R5-X RAID1 + RAID5 (PE RC H700) 2 + 3 2 + 10 55 ASSR5/R10-X RAID5 + RAID10 ( PERC H700) 4 + 4 4 + 8 R510 -12 Mixed HDD (SSD + SAS) Factory Configurati on Mixed SSD + SAS (Must be all 2.
Dell PowerEdge R510 T echnic al Guide 62 68 ASSR50/+iR1 RAID50 (PERC H700) 6 12 69 ASSR60/+iR1 RAID60 (PERC H700) 8 12 70 ASSR1/R1/+i R 1 RAID1+RAID1 (P E RC H200 , PERC H700) 2 + 2 2 + 2 71 ASSR1/R5/+i R 1 RAID1 + RAID5 (PE RC H700) 2 + 3 2 + 10 72 ASSR5/R10 /+i R1 RAID5 + RAID10 ( PERC H700) 4 + 4 4 + 8 R510-12 Mixed HDD (<Hot-swap 3.
Dell PowerEdge R510 T echnic al Guide 63 11.4 Optical Drives R510 supports a SA TA interface slim DVD-ROM or sl im DVD+/-RW. Slim OD D optio n is availabl e on 4-HDD and 8-HDD configuratio n chassis only. R510-12 does n ot suppo rt internal ODD; externa l USB ODD opt ions are available.
Dell PowerEdge R510 T echnic al Guide 64 12 Video The Matrox G200 eW w/ 8MB mem ory integrated in WPCM450 (BMC contr oller) provides: • 1280x1024@85H z for KVM an d 1600x1200@6 0Hz for video out •.
Dell PowerEdge R510 T echnic al Guide 65 13 Oper atin g Systems For the most up- to -date informat ion, see the Operating Sy stem Supp ort Matrix for Dell PowerEd ge Syst ems on Dell.com. The follo wing tables provide informatio n on operatin g systems supported on t he PowerEd ge R510.
Dell PowerEdge R510 T echnic al Guide 66 Table 28. Linux Operatin g Systems Operating Systems Version Factory Install Logo/Cert Red Hat Enterprise Lin ux 4.
Dell PowerEdge R510 T echnic al Guide 67 14 Virtualization Table 29. Supported Virt ualization Operati ng Systems Operating Systems Factory Install ( FI) Logo/Cert VMware ESX 4.0 DIB Yes VMware ESXi 4.0 (embedded version) Download version (NFI , No DIB) Yes VMware ESXi 4.
Dell PowerEdge R510 T echnic al Guide 68 15 Systems Management 15.1 Overview Dell delivers open, flexi ble, and in tegrated so lutions t hat help yo u reduce the complexity of managing disparate IT ass ets by buildi ng comprehensi ve IT manage ment solutio ns.
Dell PowerEdge R510 T echnic al Guide 69 Remote Access Cont roller) is resp onsible for acti ng as an int erface betwe en the host system and its managemen t software and the periphery devices . These periphery devi ces consist of the PSUs, th e storage backplane, integ rated SAS HBA o r PERC 6/I, and control pane l with displa y.
Dell PowerEdge R510 T echnic al Guide 70 • Server Sensor monit oring and fault alerting • Secure operation o f remote access fun ctions including authe ntication, autho rization, and encrypt ion .
Dell PowerEdge R510 T echnic al Guide 71 Feature BMC iDRAC6 Express iDRAC6 Enterprise vFlash Media SSL Encryption Remote Management and Remediation Remote Firmware Update S.
Dell PowerEdge R510 T echnic al Guide 72 16 P eripher als 16.1 USB peripherals Optional Ext ernal USB DVD-ROM 16.2 External Storage Refer to Table 2 for info rmat ion on externa l storage.
Dell PowerEdge R510 T echnic al Guide 73 17 P ack aging Options Options for sing le pack and multipa ck are available. Multipack supp orts 4 unit s in one pack. Table 32. Single Pack Dimen sions and Weights Outside Dimensions Weights Multipack Dimensions R510: 4-HDD a n d 8-HDD ch assis Length: 905mm/ 35.
Dell 74 PowerEdge R510 Technical Guide Appendix A. R5 10 V olatility T ables Table 33. PowerEdge R510 Volat ili ty Non- Volatile Volatil e RAM Reference Designator Qt y Size Type Planar System BIOS SP.
Dell 75 PowerEdge R510 Technical Guide Non- Volatile Volatil e RAM Reference Designator Qt y Size Type Control Panel Internal USB Y J_USBKEY (connector ) J_USB3, J_USB4 2 User selectable License key hard s et R OM or user choice Power Supply PSU Microcontroller Y Varies by part number Up To 2 Maximum supporte d = 2MB per PSU.
Dell 76 PowerEdge R510 Technical Guide Table 34. Volatilit y: Data Writi ng and Purpose Can user programs o r operating system w rite data to it during no rmal operati on? Purpose? Planar System BIOS .
Dell 77 PowerEdge R510 Technical Guide Can user programs o r operating system w rite data to it during no r mal operation? Purpose? Backplane (X8) Storage Controller Processor No Backplane firmwa re (HDD sta tus, etc.
Dell 78 PowerEdge R510 Technical Guide Table 35. Methodology for D ata Input to Memory How is data input to t his memory? Planar System BIOS SPI F l ash Loading flash memo ry requires a vendor- pr ovi.
Dell 79 PowerEdge R510 Technical Guide How is data input to t his memory? Chipset CMOS BIOS control only wi th input such as BIOS F2 menu user configuration settings (e.
Dell 80 PowerEdge R510 Technical Guide SAS 6/iR Integrated Controller Configuration Data Loading flash memo ry requires a vendor- pr ovided firm ware file and loader program which i s executed by boo ting the system from a flop py or OS-based executable (DUPs, Unified Server Configurator) containing t he firmware file and t h e loader.
Dell 81 PowerEdge R510 Technical Guide How is this memo r y write protected? How is the memo r y cleared? iDRAC6 SDRAM n/a AC cycle for BMC OS and reset/power off serve r for VGA frame buffer iDRAC6 FRU writes controlled by iDR AC embedded OS EPPID is not cleara ble iDRAC6 Boot Block Flash iDRAC embedded OS control of the write protection.
Dell 82 PowerEdge R510 Technical Guide How is this memo r y write protected? How is the memo r y cleared? FRU Protected. No iDR AC embedded firmwa r e writes to this device. Theoretically, IPMI I2 C Master write comma nds would flow through to overwrite this EEPROM .
Een belangrijk punt na aankoop van elk apparaat DeWalt R510 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen DeWalt R510 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens DeWalt R510 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding DeWalt R510 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over DeWalt R510 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van DeWalt R510 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de DeWalt R510 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met DeWalt R510 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.