Gebruiksaanwijzing /service van het product TEC 40D van de fabrikant Dometic
Ga naar pagina of 28
TEC 4 0 d Operation, maintenance and installation manual Libretto istruzioni per l’uso, la manutenzione e l’installazione Betriebs-, W artungs- und Installationsanleitung Manuel d’utilisation, d.
ENGLISH With Dometic at home everywhere. Thank you for your decision to buy an Dometic product. They all have been specially conceived for your vehicle, matching totally the requirements of leisure on.
©DOMETIC - 2007 All rights reserved - Printed in Italy - No part of this manual may be reproduced, copied or transmitted in any form or by any means without prior written permission from DOMETIC. Figures, descriptions, references and technical data contained in this manual are given as mere example and are not binding.
“The product is warranted in accordance with the enforced Law and regulations implementing the Direc- tive 1999/44/EC.” The Manufacturer ’ s warranty does not extend to Product failures, defects or damage arising from and/or attributable to a wrong installation.
Operation, Maintenance and Installation manual Generator Handleiding voor bediening, onderhoud en installatie Generator Manual de instrucciones para el uso, la manutención y la instalación Generador.
TEC 40D 4 user ’ s manual G B 1.2 Data plate 1.1 Purpose of the manual This manual has been made up by the Manufacturer and is an integrated part of the generator ’ s equipment. The information, if respected, will guarantee the correct use of the generator .
user ’ s manual 5 TEC 40D GB • T o prevent fire hazards and to keep the generator in an efficient working condition, do not close the same in a case or an enclosed space such as an alcove but install it in a well-ventilated area.
TEC 40D 6 user ’ s manual G B 1.5 Description of the generator W arning The TEC 40D generator has been designed and produced to be used only on caravans, motor homes and commercial vehicles. There fore it has not been designed to be used on other types of vehicles or on any kind of watercraft.
user ’ s manual 7 TEC 40D GB General informations 1 1.8 Operation description The main elements of the TEC 40D generator are: an engine (a), a permanent magnet alternator (b), an inverter (c), an internal control panel (d), a terminal board (e) and an external control panel (f).
TEC 40D 8 user ’ s manual G B 1.9 External control panel 1 General informations 1.10 Internal control panel Operation description MAIN SWITCH : turns the panel on/stops the generator ST ART BUTTON :.
user ’ s manual 9 TEC 40D GB DESCRIPTION UNIT OF MEASURE V ALUE VOL T AGE SUPPLIED V 230 ± 10% MAX CONTINUOUS POWER W 3500 ± 5% FREQUENCY Hz 50 ± 1% DIRECT CURRENT POWER V / A 12 / 10 THD % 1 CONSUMPTION g/HPh 190/200 WEIGHT kg 96.5 General informations 1 1.
TEC 40D 10 user ’ s manual G B 1 General informations 1.12 T able describing the alarm messages appearing on the display DISPLA YED MESSAGE DESCRIPTION GENERA TOR BEHA VIOUR ACTIONS LOW BA TTERY Indicates that the battery voltage is below the mini- mum value necessary to start the generator .
user ’ s manual 1 1 TEC 40D GB 1.14 Checking the oil level Remove the oil filler and clean the dipstick with a cloth. Refit by screwing the dipstick. Remove the dipstick and check that the oil level is between the two (min. and max.) marks. Add oil if necessary through the filler .
TEC 40D 12 user ’ s manual G B 2 Installation instructions 2.1 Instructions for fixing the generator 2 3 4 1.
user ’ s manual 13 TEC 40D GB 6 7 8 5.
TEC 40D 14 user ’ s manual G B Installation instructions 2 2.2 Instructions for installing the exhaust system We recommend positioning the elbow of the exhaust pipe in line with the length of the casing (as shown in the figure) so more vibrations can be absorbed.
user ’ s manual 15 TEC 40D GB Max 1.5m 3m Generator TEC 40D is equipped as standard with an electric pump for pumping fuel. The following should be done. The fuel tank should be installed with the tank basis at a maximum depth of 1.5 meters below the lower edge of the generator box.
TEC 40D 16 user ’ s manual G B Installation instructions 2 Cross-section mm 2 230V (power cables) Cross-section mm 2 12V (battery charger) Cross-section mm 2 Lenght up to 6m (battery connection) Cross-section mm 2 Lenght > 6m (battery connection) 4 2.
user ’ s manual 17 TEC 40D GB Battery connection N.B. T o start the generato r it is necessar y to use a 12VDC battery , with a minmum capacity of 60Ah. T o start the generator, connect it to the positive pole of the vehicle’s battery with a sheathed cable of a suitable cross-section as shown in the table.
TEC 40D 18 user ’ s manual G B SOLUTION The emergency stop switch is not to ON The starter is not powered up The electrical cables are broken The generator earth wire (or fuse) is broken No fuel Check the load supplied No fuel received from injectors The air filter is dirty The Air intakes are obstructed Inverter is damaged Load over 3.
user ’ s manual 19 TEC 40D GB 3.2 Check list and time intervals Maintenance chart Maintenance work required 8-15 Every 8-15 operating hours, or before each daily startup Check oil level Check combustion and cooling air intake zone.
TEC 40D 20 user ’ s manual G B T roubleshooting, maintenance, recycling 3 Important Old oil mou st not b e dispo sed of in t he env ironment , but lef t to a station specialised in the disposal and/or recycling of the same, respecting the laws in the country where the operations are carried out.
user ’ s manual 21 TEC 40D GB Air filter maintenance W arning Do not use diesel or solvents with a low evaporation point to clean the air filter element as it could catch fire or explode. Important I f the air filter is dirty this reduces the flow of air to the engine.
TEC 40D 22 G B MOTORE HA TZ DIESEL 20 19 17 13 12 8 7 29 28 27 26 14 9 11 + 2 3 9 8 6 5 4 11 10 12 1 7 N OW K N 5 8 7 6 2 1 4 3 23 12 T 11 10 9 E GR E BL U YE L BLA BR O RE D VI OL PI N GR E WH I E T .
23 TEC 40D GB CONNECTION TO THE EXTERNAL POWER SUPPL Y 1 230 230 12 1 R1 R3 3 2 R2 R4 4 A2 A1 AG1 13 GENERA TOR AG1 13 SWITCHING ACCESSOR Y (available on demand) 1) Use cables of suitable section (see ta- ble in paragraph “electrical connection”).
.
.
Via V irgilio, 3 - 47100 Forlì - T el. 0543/754213 Fax.0543/756631 DOMETIC ST095 r0.
Een belangrijk punt na aankoop van elk apparaat Dometic TEC 40D (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dometic TEC 40D heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dometic TEC 40D vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dometic TEC 40D leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dometic TEC 40D krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dometic TEC 40D bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dometic TEC 40D kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dometic TEC 40D . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.