CONTENTS Your central vacuum system package consists of the following items.
Installation ..........................................................3


How to use .........................................................4
LED Indications ..................................................4
LCD Screen ........................................................4

Utility Valve .........................................................5
Overheating Protection .......................................5
Adapter 90° Elbow Bag Adapter
Diagnostics And Maintenance ............................5
Filter Maintenance ..............................................6
Paper Bag Filter ..................................................6
Bag Adapter Intake Insert
Images ...............................................................7
READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER SYSTEM. This central vacuum power unit is intended for the removal of normal household dust.
To reduce the risk of fi re, electric shock or injury:

PRODUCT DIMENSIONS
The central vacuum is designed for dry pick-up of household dirt and dust. Avoid picking up hard or sharp objects with this system to prevent hose and plastic pipe damage or clogs.
This manual will cover the fi nal steps of installation of the power unit in your home. It will also provide the necessary information for maintenance and trouble shooting, in the unlikely event that it will be needed. If you require further information about installation or inquires on the product please contact your local authorized dealer/distributor.
This symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it should be handed over to applicable collection point for the recycling of electronics and electrical equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about this product, please contact your local waste disposal service or the shop where you purchased the product.
For wall preparations and cover preparations, safety equipment such as helmet, gloves, goggles and hearing protection are recommended.
CAUTION
Your home is most likely already fi tted with the system of plastic pipes and inlet valves and you are ready to install the central power unit. If your home is not fi tted for a central vacuum system, you can contract to have the Electrolux Central Vacuum System installed by a professional by contacting your local dealer or distributor or choose to do-it-yourself.
Use caution when drilling holes in walls as gas pipelines and water pipes and electrical wires may be present.
If you have any questions regarding the product, spare parts, service, warranty or anything else, please contact your local authorized dealer or distributor.
The central power unit should be located as far away from the general living area as possible, yet accessible so you can remove the dirt receptacle, reach the filter, and inspect the central power unit. A typical location would be in a garage, where you could vacuum your car or garage area, and where emptying the dirt receptacle and cleaning the filter would be more convenient. Other suitable locations are in the basement, laundry room, or ventilated storage room.
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electrical current to reduce the risk of electrical shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING
Use caution when drilling holes in walls as gas pipelines and water pipes and electrical wires may be present. Holes in the masonry are only allowable if through it its standing stability is not impaired. Holes in wood studs should be drilled. Depending on what material your home is built with, use the appropriate anchors to hang your power unit. Power unit simply slides onto mounting bracket and clicks into place.
Improper connection of the equipment-grounding conductor can result in electrical shock. Check with a qualifi ed electrician or service person if you are in doubt as to whether the outlet is properly grounded, or if the plug does not fi t into an outlet. Do not modify the plug provided with the appliance.
If the supply cord is damaged, it must be replaced by a special cord available from your local authorized dealer/distributor.
The instructions in this booklet serve as a guide to routine maintenance. For additional information, contact your nearest authorized dealer/distributor.
The model, type, and serial numbers are indicated on the rating plate located on the control panel or motor hood. For prompt and complete service information, always refer to these numbers when inquiring about service.
Your Electrolux Oxygen CVS does not require the assembly of a muffl er. Your CVS has the muffl er installed internally. You may however desire to exhaust the air outside. In this case you will need to attach the exhaust adapter. This will convert the size of the exhaust to the diameter of the central vacuum pipe.
Non-observance of the safety directions may result in bodily harm.

Your machine may be equipped with some or all of the indicators listed below.
On/Off Motor Fault Dirt Receptacle Full Reset
Your power unit is equipped with a multi color LED panel. This LED panel will provide you with necessary information on your power unit’s performance, maintenance and diagnostics. Below are descriptions of the different messages the power unit will provide.
When the power unit is OFF and considered to be in standby mode the LED button will be RED.
When the power unit is ON and in use the LED will be GREEN. When the motor fault light is ON see further description below. When the dirt receptacle light is ON, empty dirt receptacle, press the RESET button and hold for 10 seconds.
Do not block the hood ventilation openings on the top of the central power unit. Lack of ventilation will cause the motor to overheat.
WARNING
In the case of a blown fuse or disconnected motor wire and the power unit is not functioning, the RED, GREEN and AMBER lights will remain constantly lit.
Do not locate the central power unit in a high temperature area where it is inaccessible for example, an attic or crawl space.
For the ultimate in air control you have the True HEPA fi lter and may be included with your choice of power unit or can be purchased from an authorized dealer/distributor. Simply attach the true HEPA fi lter as shown.
In the case of an over current shutdown, the ON/OFF button’s RED light will be fl ashing, the GREEN light will turn on and of rapidly, and the MOTOR FAULT light will be AMBER and turn on and off rapidly. This fault will reset automatically in 15 seconds if the low volt connection is OFF at the hose. In the case of a continued over current shutdown and the low volt connection is ON at the hose, the ON/OFF button’s RED light will be constantly lit, the GREEN light will fl ash slowly and the MOTOR FAULT light will slowly fl ash AMBER.
Be certain to comply with local electrical codes and regulations. Plug the unit into a regular electrical outlet. You are now ready to check the installation of the unit:
In the unlikely event of a bad frequency received by the power unit, the power unit will not start and the ON/OFF button’s RED light will remain constantly lit. In the case of a high line voltage received by the power unit, the ON/OFF button’s lights will alternate between RED and GREEN three times- pause briefl y – alternate between RED and GREEN three times – long pause- and then repeat. This will continue until the line voltage returns to the correct level.
In the main screen of the LCD, the Electrolux logo will appear. This logo may scroll from side to side to avoid the image ingraining itself onto the LCD Display. You will see the logo when the power unit is not in use.
Your central vacuum system is controlled by a switch on your hose. Simply insert the hose into the valve and turn the switch to the on position. This will start the power unit and the fl ow of air.
The button that best lines up with the Power symbol on the screen can be used to activate the unit. Press this button to toggle the unit on/off. The unit may also be activated from any installed inlet.
When you are fi nished, turn the switch on the hose to the off position and remove the hose from the inlet valve. When unplugging the hose, hold the inlet cover open for a few seconds to allow suction to decrease thus, protecting the inlet valve seal.
When you LCD power unit is in standby mode the four white lights on your LCD unit will light up in sequence and alternate moving from left to right then reversing right to left. This pattern will repeat continuously and is an indication that your power unit is ready for use and functioning properly.

When in use, the power indicator turns green. The 4 progressive performance bars will appear. A normal functioning unit should have all 4 performance bars lit. If there are consistently less than 2 bars, you should check for the problem. Possible issues causing the performance bars to lessen could be:
When not in use, you can scroll through the features of your LCD to observe the dirt receptacle status, life monitor measure or most recent recorded power level.
To scroll through these features simply push the button corresponding with the right pointing arrow symbol.
The next screen you will see will be the Life Meter. Scroll right further and you will fi nd Bucket Status. Yet another scroll will show you last recorded performance levels of the power unit, using the Performance Meter on the In-Use screen. The fi nal scroll right will show you the customer service phone number.
The button lining up with the left scroll button will allow you to scroll backwards through the screens.
BAG ADAPTOR
Your power unit can all be fi tted with a convenient paper bag for more convenient dirt disposal. For maintenance of the paper bag, please see the Paper Bag Filter section, under Filter Maintenance.
Every 25 hours of use (approximately 6 months) the empty dirt receptacle indicator will fl ash on the screen. This is an indication to check the dirt receptacle and empty it. Since this is time based, you may fi nd the dirt receptacle too empty or too full. If you have pets, a workshop or other factors that cause waste more frequently, you may wish to check the dirt receptacle more frequently.
The utility valve is similar to an Inlet valve, but is located near the power unit. This valve is present for your convenience, as it can help clean up any dirt spilled close to the central vacuum.
Once the dirt receptacle is emptied, you push the return button to reset the 25 hours timer. If your power supply is interrupted, or otherwise unplugged, the empty dirt receptacle indicator will keep a memory of its previous status and continue life measure.
If the circuit board reaches an elevated temperature, the power unit will not operate and the LED will be off or on LCD model the screen will be fl ashing. In the event of these problems, press the On/Off button, unplug hose or wait for temperature to lower. If problems persist; contact your authorized dealer or distributor.
To manually reset the Empty Dirt Receptacle indicator, simply press the button lining up with the Enter symbol and hold for 10 seconds.
The life meter has 8 bars on it. Once these bars are depleted your unit will continue to run, although it is strongly recommended to take it to your local authorized dealer/distributor to be inspected and serviced. A life bar will deplete every 65 hours of vacuum use, meaning your central vacuum will have a long life of service to you. The life meter can be reset only by your service technician. If your power supply is interrupted, or otherwise unplugged, the life meter will keep a memory of its previous status and continue life measure.
The central vacuum system employs features that monitor the following operating levels: AC voltage, and current draw. If the voltage is below or above standard operating voltage, high current draw or locked rotor, the power unit will not operate. In this case the On/Off button will blink until the problem ceases or on the LCD model the screen will fl ash. If problems persist; contact your authorized dealer or distributor. The power unit requires 30 minutes to cool down.
DIAGNOSTICS AND MAINTENANCE
If there is a system fault, or malfunction with your power unit, the service indicator will fl ash. Upon seeing this symbol, we recommend that you turn the power unit off, unplug the power supply for 10 seconds and then plug it back in. If the service symbol is still on the screen, we recommend that you call for service.
Reduced airfl ow or suction indicates the central vacuum system is not operating at maximum effi ciency. If the dirt receptacle is full and the fi lter is clogged, no air can pass through the unit and no cleaning can take place. Instructions provided in the booklet serve as a guide to routine maintenance. Proper airfl ow or suction can be maintained by keeping the dirt receptacle and fi lter clean and the plastic tubing and hose free from clogs.
This symbol may appear due to the following faults:

POWER UNIT WILL NOT START
Most models feature dirt receptacles with windows to tell at a glance when the dirt receptacle should be emptied. In most cases, the dirt receptacle only needs to be emptied two to three (2-3) times a year. To remove the dirt receptacle, press the buttons on the receptacle handles. Remove and empty the contents. Return the receptacle by attaching the bucket to the power unit. To avoid suction loss make sure the receptacle is securely attached.
FILTER MAINTENANCE
Electrolux’s exclusive fi lter is permanent and self cleaning. However, if you have questions about your permanent self-cleaning fi lter, please contact your local authorized dealer/distributor.
CENTRAL POWER UNIT SHUTS OFF BY ITSELF
The volume of the paper bag is 22 liters. A full dust bag reduces the systems performance. Depending on how often you use your central vacuum system, the dust bag may need to be changed 2-3 times per year – and can be obtained at your local dealer/distributor.
Warranty is handled by your local authorized dealer/distributor. Please contact your local authorized dealer/distributor for questions regarding warranty.
IF YOU EXPERIENCE TROUBLE WITH YOUR ELECTROLUX CENTRAL VACUUM SYSTEM, FOLLOW THE SUGGESTIONS BELOW BEFORE CALLING FOR SERVICE.
Plug hose into any inlet valve. If there is no suction through the hose after connecting at a couple of inlets, the blockage is in the hose. To clear the hose obstruction, insert a blunt instrument into the hose (garden hose, wood dowel). You can also attempt to reverse the suction through the hose to dislodge the blockage.
Refer to page 7 - Image 12 and 13
If there is one inlet valve without normal suction and you have checked for hose blockage, then the blockage is in the pipe system between the blocked inlet valve and the power unit (see instructions below).
Insert the hose into the inlet valve where there is no suction; hold your hand over the hose end. Release hand quickly. Repeat several times. If blockage does not clear, contact your nearest Electrolux dealer/distributor.


Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.