Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P Oc tobe r 2013 6081-P Wireless pH/ORP T ransmitt er Esse nti al Instruc tions – R e ad this be f ore proc eeding Ro se mount An aly tical designs, manu factures, and tests its products to meet m any n ation al and inte rna tional standar ds.
2 6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P • Install your equipmen t a s spec ied in the Installation Instructions of the appr opriat e Instruction Manual and pe r applicable local and n ational c odes. C onnect all produc ts to the proper e lectrical and pressure sourc es.
3 Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P Oc tobe r 2013 Quick S tar t Guide - 6081 Wire les s pH T ransmitte r 1. Install the Po we r Module inside the re ar e nclosure . F ollow the installation instruc tions on p .9 “Powe r Module Installation ”.
4 6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Figure 2. Menu T r ee for 6081 pH Wireless T ransmitter.
5 Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P Oc tobe r 2013 Produc t Description When used with appropri ate sensors, the 6081-P can me a sure pH or ORP (o xida tion reduction pot en tial) o f a liquid and transmit d ata wire lessly with a radio transc eiv er whic h u ses HAR T 7 communi cation pro toc ol.
6 6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P EEPROM W arning Sense Line Open W arning F ac tor y Cal W arning Ke yboard W arning Once a fault or warning is detected, the displ ay will show a message describing the proble m.
7 Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P Oc tobe r 2013 pH Calibration Proc edure – A uto Buff er Calibration 1. Obtain two buff er solutions. Ide ally , the buff er values sho uld brack et the range of pH values t o be mea sured. 2. Re mov e the pH se nsor from the proc ess liquid .
8 6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Se nsor Wiring Note For additi onal wiring inf ormation on this pr oduct, including sensor c ombina tions not shown he re , plea se ref er t o eithe r our online wiring programs or the Manu al D VD e nclosed with e ach product.
9 Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P Oc tobe r 2013 Po we r Module Installa tion / R e pl ac eme nt The expected life of the powe r module (PN 701PBKKF) is a minimum of four ye ars at re f ere nce conditions. This section describes the procedur e f or initial installation and re plac eme nt of the powe r module (PN 701PBKKF).
10 6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Mounting Mounting on a Fl at Sur fac e Figure 4. W all Mounting Installation for 6081. Use Pipe/W all Mounting Brack et Kit, PN23820-00 Note : PN 23820-00 mounting bracket kit inc ludes mounting hardware for pipe mounting only .
11 Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P Oc tobe r 2013 Pipe Mounting The pipe mounting kit (PN 23820-00/01) accommod ate s 1–½ in. pipe Figure 5.
12 6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P This document contain s information proprietary to Rosemount An alytical, and is not to be made availab le to those who m ay compete with Rosem ount Analytical.
13 Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P Oc tobe r 2013 This document contain s information proprietary to Rosemount An alytical, and is not to be made availab le to those who m ay compete with Rosem ount Analytical.
14 6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P This document contain s information proprietary to Rosemount An alytical, and is not to be made availab le to those who m ay compete with Rosem ount Analytical.
15 Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P Oc tobe r 2013.
6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Credit Cards for U .S. Purcha ses Only . Emerson Process Management 2400 Barranca Park way Ir vine, CA 92606 USA T el: (949) 757-8500 F ax: (949) 474-7250 rosemo untanalytical.com © Ro semount An alytical Inc.
Een belangrijk punt na aankoop van elk apparaat Emerson 6081-P (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson 6081-P heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson 6081-P vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson 6081-P leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson 6081-P krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson 6081-P bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson 6081-P kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson 6081-P . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.