Gebruiksaanwijzing /service van het product 4H4283-49 van de fabrikant Enterasys Networks
Ga naar pagina of 90
7.5x9-inch cover with bleed on 4 sides Enterasys Matrix ™ DFE-Gold Series Hardware Installation Guide Module 4H4282-49 Module 4H4283-49 Module 4H4203-72 Module 4H4202-72 Module 4H4284-49 P/N 9033906.
.
i Notice Enterasys Networks reserv es the right to make changes in specif ications and other info rmation contained in this document and its web site without prior notice.
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device com plies with Par t 15 of th e FCC rules.
iii Electromagnetic Compatibility (EMC) This product complies with the follo wing: 47 CFR Par t s 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3.
iv ѻ ѻ ક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 .
v VCCI Notice This is a class A product based on the standard of the Vo l u n t a r y Control Co uncil for Interfe rence by Information Te c h n o l o g y Equipment (VCCI).
vi Declaration of Conformity Application of Co uncil Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer ’ s Name: Enterasys Networks, Inc. Manufacturer ’ s Address: 50 Minuteman Road Andover , MA 01810 USA European Representativ e Address: Enterasys Networks, Ltd.
vii Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZIN G THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“ Agreement”) betwee n the end user (“Y o u”) and Enteras ys Networks, Inc.
viii 3. APPLICABLE LAW. This Agreem ent shall be interpreted and governed under the laws and in the state and federal courts of th e Commonwealth of Massachu setts with out regard to its conflicts of laws provis ions.
ix 8. AUDIT RIGHTS. You here by acknowled ge that the intellectual property rights associated with the Program are of critical value .
x.
xi Contents About This Guide Who Should Use This G uide .............. ....................... ....................... ......................... ................ .......... xv How to Use This Guide ................ ....................... ............
xii Connecting to COM Port for Local Management ................... ....................... ...................... ............. 3-20 What Is Needed ..... ...................... .................... ...................... ....................... .....
xiii Figures 1-1 4H4282-49, 4H4283-49, and 4H4203-72 DFE-Gold Modules .................... ...................... ............ 1-4 1-2 4H4202 -72 and 4H4284-49 DFE-Gold Modules . ....................... ...................... ....................... .
xiv Tables 3-1 Contents of DFE-Gold Module Carton .............. ...... .................... ...................... ....................... ..... 3-2 4-1 LANVIEW LEDs ......... ....................... ...................... ....................... ...
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide xv About This Guide This guide provides an ov erview , installation and troubleshooting instruction.
How to Use This Guide xvi About This Guide How to Use This Guide This preface provides an overview of this guide and the DFE ‐ Gold Series manual .
Conventions Used in This Guide Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide xvii Conventions Used in This Guide The following conventions are used in th.
Getting Help xviii About This Guide Getting Help For additional support related to the modules or this document, contact Enterasys Networks using on.
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-1 1 Introduction This chapter provides an overview of the DFE ‐ Gold module capabilities, .
The DFE-Gold Modules 1-2 Introduction • Reduced support and maintenance costs, and decreased configuration time • Support for a var i et y of .
The DFE-Gold Modules Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-3 4H4203-72 The 4H4203 ‐ 72 has 72, 10BASE ‐ T/100BASE ‐ TX compliant ports through six front ‐ panel RJ21 connectors.
The DFE-Gold Modules 1-4 Introduction Figure 1- 1 4H4282- 49, 4H4283-49, and 4H4203- 72 DFE-Gold Modules 1 OFFLINE/RESET button 6 GROUP status LEDs 2 RJ45 COM (Console Port) 7 GROUP select LEDs 3 CPU .
The DFE-Gold Modules Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-5 Figure 1-2 4H4202 -72 and 4H4284-49 DF E-Gold Modul es 1 OFFLINE/RESET switch 6 GROUP select LEDs 2 RJ45 C.
Connectivity 1-6 Introduction Connectivity 4H4282-49 Depending on how the 4H4282 ‐ 49 ( Figure 1 ‐ 1 ) is configured, it can support up to: • 48, .
Management Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-7 Management Management of the module can be either in ‐ band or out ‐ of ‐ band.
LANVIEW Diagnostic LEDs 1-8 Introduction •N e t w o r k Services are logical groups of Classification Rules that identify specific networked applic ations or services .
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 2-1 2 Network Requirements Before inst alling the module, review the requirements and specificat io.
100BASE-TX Network 2-2 Network Requirements 100BASE-TX Network Fixed front panel ports of the 4H4282 ‐ 49, 4H4283 ‐ 49, 4H4203 ‐ 72, and 4H4202 ‐ 72 provide a connection that supports Category 5 UTP cabling.
Matrix DFE-Gold Series Modules Hardware Installation Guide 3-1 3 Installation This chapter provides the instructions to install the 4H4282 ‐ 49, 4H4283 ‐ 49, 4H4203 ‐ 72, 4H4202 ‐ 72, and 4H4284 ‐ 49 DFE ‐ Gold modules.
Installation Site Requirement 3-2 Installation Inst allation Site Requirement The DFE ‐ Gold module must be installed in a Matrix E7, N1, N3, N5, or N7 chassis located in a Restricted Access Location (RAL).
Installing Optional Netw ork Expansion Module Matrix DFE-Gold Series Modules Hardware Installation Guide 3-3 Inst alling Optional Network Exp ansion Module A Phillips screwdriver is re.
DFE Module Placement and Installation Rules 3-4 Installation To ensure proper operation of the system, consider the following examples and rules for module placement in either chassis.
Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installation Guide 3-5 Example 3 ( Figure 3-1 , C) Shows the primary management module missing from slot 1.
Installing Module into a Chassis 3-6 Installation Prep aration 1. Remove the blank pan el cov ering the slot in which the module will be installed. All other slots must remain cov ered to ensure proper airflow for cooling.
Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installation Guide 3-7 2. Align the module card between the upper and lower card guides.
Installing Module into a Chassis 3-8 Installation Figure 3-2 Inst alling Module into M atr ix E7 or N7 Chassis (Matrix E7 shown) 1 Card guides 5 Upper/lower locking tabs (in proper open position) 2 Sl.
Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installation Guide 3-9 Inst alling Module into Matr ix N1, N3, or N5 Chassis A DFE ‐ Gold module can be insta.
Connecting to the Network 3-10 Installation Connecting to the Network For connecting unshielded twisted pair (UTP ) segments from the network or other d.
Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-11 Connecting UTP Cables to 4H4282-49 or 4H4202-72 The fixed RJ4 5 front panel connections of the 4H4282 ‐ 49 and 4H4202 ‐ 72 are 10/100 Mbps ports.
Connecting to the Network 3-12 Installation 3. V erify that a link ex ists by check ing that the port RX (Receive ) LED is ON (flashi ng amber , blinking green, or solid green).
Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-13 Figure 3-5 Four-Wire Crossover Cable RJ45 Pinout s, Connections Between Hub Devices 1 RJ45 device port 3 RJ45-to-RJ45 crossover cable 2 Other device port 4 RX+/RX- and TX+/TX- connections.
Connecting to the Network 3-14 Installation Figure 3-7 Eight-Wire Crossover Cable RJ45 Pinout s, Connections Between Hub Devices 1 RJ45 device port 3 RJ45-to-RJ45 crossover cable 2 Other device port F.
Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-15 e. Ensure that the twisted pai r connection meets the dB loss and cable specifications outlined in the Cabling Guide.
Connecting to the Network 3-16 Installation 3. T o install an RJ21 right ‐ angle connector , refer to Fi gure 3 ‐ 10 and proceed as follows: a.
Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-17 Figure 3-10 Connection Using Optional RJ21 An gle Adapter 1 RJ21 angle adapter 5 Retaining clips 2 RJ21 port connector 6 GROUP SELECT button 3 Retaining screws 7 Example showing how multiple cables would be arranged along the front panel.
Connecting to the Network 3-18 Installation 4. V erify that a link ex ists by check ing that the port RX (Receive ) LED is ON (flashi ng amber , blinking green, or solid green).
Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-19 2. Insert the MT ‐ RJ cable connector into the MT ‐ RJ front panel connector until it clicks into place.
Connecting to COM Port for Local Management 3-20 Installation 1. V erify that a link ex ists by check ing that the port RX LED is ON (flashing amber , blinking green, or solid green).
Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-21 Wi th a UTP straight ‐ through cab le and RJ45 ‐ to ‐ DB25 .
Connecting to COM Port for Local Management 3-22 Installation Connecting to a VT Series T erminal To connect a VT Series terminal to an Enterasys Netw orks DFE ‐ .
Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-23 When these parameters are set, the Local Management password screen will display .
Connecting to COM Port for Local Management 3-24 Installation 5. With a PC connected to a remote mo dem, you can configure th e switch remotely .
Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-25 Adapter Wiring and Signal Assignment s COM Port Adapter Wiring and Sign al Diagram RJ45 DB9 .
Completing the Installation 3-26 Installation Completing the Inst allation Completing the DFE module installat ion depends on if the module is being ins.
Completing the Installation Matrix DFE-Gold Series Modules Hardware Installation Guide 3-27 First-T ime Log-In Using a Console Port Connection Start the Command Line Interface (CLI) from the module’ s local console port as follo ws: 1.
Completing the Installation 3-28 Installation Completing the Inst allation of a DFE-Gold Module in an Existing System In an established DFE ‐ Gold module system, •a DFE ‐ Gol.
Completing the Installation Matrix DFE-Gold Series Modules Hardware Installation Guide 3-29 Logging in with an Administrati vely-Configured User Account If the device’ s default user account settings have been changed, proceed as follows: 1.
Completing the Installation 3-30 Installation.
Matrix DFE-Gold Series Modules Hardware Installation Guide 4-1 4 T roubleshooting This chapter provides information concerning the following: • Using LANVIEW (page 4 .
Using LANVIEW 4-2 Troubleshooting Viewing Receive/T ransmit Activi ty on 4H4282-49, 4H4283-49, and 4H4203-72 On the 4H4282 ‐ 49, 4H4283 ‐ 49, and 4H4203 ‐ 72 you can view the receive and transmit activity on the RX and TX LEDs.
Using LANVIEW Matrix DFE-Gold Series Modules Hardware Installation Guide 4-3 Viewing Receive/T ransmit Activity on 4H4202-72 On the 4H4202 ‐ 72, you can view the receive and transmit activity on the RX and TX LEDs.
Using LANVIEW 4-4 Troubleshooting Viewing the Receive and T ran smit Activity on 4H4284-49 On the 4H4284 ‐ 49 DFE ‐ Gold module, you can view the receive and transmit activity on the RX and TX LEDs.
Using LANVIEW Matrix DFE-Gold Series Modules Hardware Installation Guide 4-5 T able 4-1 LANVIEW LEDs LED Color Stat e Recomme nded Action MGMT None Off . This module is NOT the Management Module. None. Green Solid . This module is the designated Management Module.
Using LANVIEW 4-6 Troubleshooting RX (Receive) None No link . No activity . Port enabled or di sabled. None. Green Solid . Link present, port enabled, no traffic is being received by the i nterface. None. Amber Flashing . Link present, port enabled, traffic is being received by the i nterface.
Troubleshooting Checklist Matrix DFE-Gold Series Modules Hardware Installation Guide 4-7 T roubleshooting Checklist If the module is not work in g properly , refer to .
Troubleshooting Checklist 4-8 Troubleshooting Port(s) goes into standby for no apparent reason. Loop conditio n detected. V erify th at S panning T ree is enabled. Refer to the Enterasys Matrix DFE-Gold Series Confi guration Guide for the instructions to set the type of ST A.
Overview of DFE-Gold Module Shutdown Procedure Matrix DFE-Gold Series Modules Hardware Installation Guide 4-9 Overview of DFE-Gold Module Shut down Procedure The DFE ‐ Gold module s installe.
Overview of DFE-Gold Module Shutdown Procedure 4-10 Troubleshooting Recommended Shut down Procedure Using OFFLINE/RESET Switch Before pulling a DFE ‐ Gold module out of a chas sis, press or tap on its OFFLINE/RESET switch for less than 1 second.
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-1 A Specifications This appendix provides information about the foll owing: • DFE ‐ Gold Module .
DFE-Gold Module Specifications A-2 Specifications 4H4203-72 Ports 1 through 72 Seventy- two, 10BASE-T/100BASE-TX compliant ports through six RJ21 connectors. 4H4202-72 Ports 1 through 72 Seventy- two, 10BASE-T/100BASE-TX compliant ports through 72 RJ45 connectors.
COM Port Pinout Assignments Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-3 COM Port Pinout Assignment s The COM port is a serial communications port for loc al access to Local Management.
Regulatory Compliance A-4 Specifications Regulatory Compliance The 4H4282 ‐ 49, 4H4283 ‐ 49, 4H4203 ‐ 72, 4H4202 ‐ 72, 4H4284 ‐ 49, and 7G ‐ 6MGBIC mee t .
Matrix DFE-Gold Series Modules Hardware Installation Guide B-1 B Mode Switch Bank Settings and Optional Installations This appendix covers the following items: • Required T o.
Setting the Mode Switches B-2 Mode Switch Bank Settings and Optional Installations Setting the Mode Switches Figure B ‐ 1 and Figure B ‐ 2 show the location of the mode switches and the switch settings for normal operation.
Setting the Mode Switches Matrix DFE-Gold Series Modules Hardware Installation Guide B-3 Figure B-1 Mode Switch Location on 4H4282-49 and 4H4283-49 1 Mode switch bank (located in same location on both.
Setting the Mode Switches B-4 Mode Switch Bank Settings and Optional Installations Figure B-3 Mode Switch Location on 4H4202-72 1 Mode switch bank Figure B-4 Mode Switch Location on 4H4284-49 1 Mode s.
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-5 Memory Locations and Replacement Procedures In the event that the Dual .
Memory Locations and Replacement Procedures B-6 Mode Switch Bank Settings and Optional Installations Figure B-6 DIMM and DRAM SIMM Locations (4H4203-72) 1 DRAM SIMM 2 DIMM 3 Main PC board Figure B-7 D.
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-7 DIMM Replacement Procedure (4H4282-49 and 4H4283-49) To remov e and replace t.
Memory Locations and Replacement Procedures B-8 Mode Switch Bank Settings and Optional Installations 2. Refer to Figure B ‐ 9 . Push the connector arms aw ay from the memor y module to release it from the connector .
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-9 Removing the DRAM SIMM from 4H4203-72 To remov e the existing DRAM SIMM, proceed as follows: 1. Locate the DRAM SIMM connector on the main PC board.
Memory Locations and Replacement Procedures B-10 Mode Switch Bank Settings and Optional Installa tions 3. Pull the DRAM SIMM straight up and remove it from the connector .
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-11 DRAM SIMM Replacement (4H4202-72) Figure B-12 Installing the DRAM SIM M on 4H4203-72 1 Conne.
Memory Locations and Replacement Procedures B-12 Mode Switch Bank Settings and Optional Installa tions DIMM Replacement Proc edure (All DFE Modules) In the event that the DIMM need s to be replaced, the following sec tions explain how to remove and install the DIMM.
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-13 Inst alling the DIMM To install a DIMM, refer to Figure B ‐ 14 and proceed as follows: 1. Insert the DIMM down between the connector fingers .
Memory Locations and Replacement Procedures B-14 Mode Switch Bank Settings and Optional Installa tions.
Index-1 Index Numerics 100BASE-FX connections 3-18 requirements 2-2 100BASE-TX connections 3-1 1 requirements 2-2 10BASE-T connections 3-1 1 , 3-15 requirements 2-1 4H4202-72 introduction to 1-3 4H420.
Index-2 Matrix N3 chassis module installation into 3-9 Matrix N5 chassis module installation into 3-9 Memory replacement of DRAM B-12 Memory locations DIMM and SIMM B-5 Mode Switch setting of B-2 Modu.
Een belangrijk punt na aankoop van elk apparaat Enterasys Networks 4H4283-49 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Enterasys Networks 4H4283-49 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Enterasys Networks 4H4283-49 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Enterasys Networks 4H4283-49 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Enterasys Networks 4H4283-49 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Enterasys Networks 4H4283-49 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Enterasys Networks 4H4283-49 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Enterasys Networks 4H4283-49 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.