Gebruiksaanwijzing /service van het product 5H103-48 van de fabrikant Enterasys Networks
Ga naar pagina of 52
5H102-48 and 5H103-48 F ast Ethernet Installation Guide FAST ENET 5H103-48 GROUP GROUP SELECT RESET COM CPU GROUP 37X 48X G R O U P 4 25X 36X G R O U P 3 13X 24X G R O U P 2 1X 12X G R O U P 1 FAST EN.
.
i NOTICE Enterasys Netw ork s and its lic ensors reserv e t he right to ma ke cha nges in sp ecif ication s and ot her inform ation c ontain ed in this doc ument witho ut prior notice. Th e reader should in a ll cases consult En te rasys Netwo rks to determine whether any such change s have been made.
ii FCC NOTICE This de v ic e co mplies with P art 15 of the FCC rules. Ope rat ion is subject to th e follo wing two c ondit ion s : (1) t his de vice may not cause harmful i nterference, and (2) th is device must accept any interfe rence rece iv ed, includ ing int erference that may ca u se undesi re d operat ion .
iii ENTERASYS NETWORKS, INC. PROGRAM LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT , CAREFULL Y READ THIS LICENSE A GREEMENT . This documen t is an agreement (“ Agreement”) between Y ou, the end use r, and Enterasys Networks, Inc.
iv 5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS . The enc losed Pr oduct (i) was de veloped solely at private expen se; (ii) contains “rest ricted computer software” submitte d with restricted rights in accordance with secti on 52.
v DECLARATION OF CONFORMITY Appli ca tio n of C ou nc il Di re ct ive ( s) : 89/336 /EEC 73/23/EEC Manufacturer’s Name: Enterasys Network s, Inc. Manufactur er’ s Address: 35 Industrial Wa y PO Box 5005 Roches ter, NH 03867 European Re presentative Name: Mr.
vi.
vii Contents Figures ......... ............. ................... ............. ................... ............. ................... ............... ..... ............... ix Tables.... .................... ............ .................... ...........
viii 3 INSTALLATION 3.1 Unpackin g the Modu le ............. .................... ............. ................... ................... 3-2 3.2 Installing t he Module into the 5C1 05 Chass is ................. ................... ............. 3 -3 3.
ix Figures F i g u re P a g e 1-1 The 5 H1 0 2-48 a nd 5 H10 3 -48 M od u le s .... . ..... . ...... . ..... . ...... . ..... . ..... . ...... . ..... . ...... . ..... . ..... . 1-2 3-1 Installin g a M o dul e into the 5C1 0 5 C h assi s ... . ...... .
x Ta b l e s Ta b l e Pa g e 3-1 Contents of Modu le Carton ....... ....... ...... ....... ...... ....... ...... ....... ...... ...... ............. ....... ...... 3-2 4-1 LANVIEW LEDs ........................ ............. .................... ......
xi About This Guide W elcome to the 5H102-48 and 5H103-48 Fast Ethern et Instal lation Guide . This guid e descri bes the Fa st Ethernet modul es and pro vides informa t ion concerning network re quirements , instal lation, and tro ubleshooting.
Related Docum ents xii Chapter 2 , Net work Require m ents , ou tlines the ne twork requi reme nts th at must be met b efore instal ling the module. Chapter 3 , In stallation , provides instructions on how to install the module , and connect se gments to the mo dules .
Document Conv entions xiii DOCUMENT CON VEN TIONS The guide uses the follo wing con v entions: NOTE: Calls the reader ’ s atten tion to any item of inf ormati on that may be o f specia l impo r tance . TIP: Conv eys helpful hints c oncer ning pr ocedures o r actio ns.
Getting H elp xiv GETTING HELP F or additional support relate d to the product or this documen t , contact Enter asys Network s using one of the followin g met hods : Before c ontacting Enterasys Netw.
Introducti on 1-1 1 Intr oduction This chap ter introdu ces the 5H102-48 an d 5H103-48 Fa st Ethernet m odules. The 5H102-48 module ( Fig ure 1-1 ) featur es 48 10B ASE-T /100B ASE-TX switched po rts connecte d through 48 RJ4 5 front panel con nectors.
1-2 Introduc tion Figure 1-1 The 5H102-48 a nd 5H103-48 Modul es FAST ENET 5H103-48 GROUP GROUP SELECT RESET COM CPU GROUP 37X 48X G R O U P 4 25X 36X G R O U P 3 13X 24X G R O U P 2 1X 12X G R O U P .
Connecti vity Introdu ction 1-3 1.1 CONNECTIVITY The modul e connects to Et hernet netw orks or wo rkstatio ns through the fr ont panel conne ctors. The ports su pport Uns hielde d T wisted Pa ir (UTP) cables with an impedanc e betw een 85 and 111 ohms at lengths up to 100 meters.
P or t/VL AN Redir ect Functi on 1-4 Introduc tion 1.5 P OR T/VLAN REDIRE CT FUNCTION The port redirect func tion, also refe rred to as “Port Mirroring,” is a troubleshoo ting tool used t o map traf f ic from a singl e source port t o a single desti nation port wit hin the module.
Swi tching O ptions Introdu ction 1-5 1.9 SWITCHING OPTIONS The module p rovides 802.1Q switching between all of t he front panel i nterfaces. I n the 802.1Q mode (the default mode of operation), th e module functi ons as an 802.1D sw itch until you conf igure VLANs.
.
Network Requirem ents 2-1 2 Netw ork Requirements Before in sta llin g the mod ule, re vie w the req uirem ents an d specif icat ions ref erre d to in thi s cha pter concerni ng the follo w i ng: • Port T runki ng ( Section 2. 1 ) • 10B ASE-T T wisted Pa ir Network ( Section 2.
100BASE -TX Ne twork 2-2 Network Requiremen ts 2.3 100B ASE -TX NETW O RK The f ixed f r ont panel port s of the module pro vide a co nnection that su pports Categ ory 5 UTP cablin g. The de vice at the othe r end of the twis ted pair se gment must meet IEEE 802 .
Install ation 3-1 3 Installa tion This chap ter pro vides the instr uctions to inst all the 5H102 -48 or 5H103-48 module . A Phillips scr ewdriver is re quire d to in sta l l opt ions i nto th e mod ule. Follow the o r d er o f the s ectio ns l i s ted belo w to corre ctly install the module.
Unpacking the Module 3-2 Insta llation 1. Open the bo x and remove the packing material protecting th e module. 2. Verify t he contents of the carto n as listed in Table 3-1 . 3. Remove t he tape se al on the non-cond uctive bag to re move the module.
Installi ng the Mod ule in to the 5C105 Chassis Install ation 3-3 3.2 INSTALLING THE MODULE INTO THE 5C105 CHASSIS T o instal l a module, r efer to Figur e 3-1 and proceed as follo ws: 1. Remove t he bl ank pa nel co vering the slot in whi ch the module will be install ed.
Installi ng the Mod ule in to the 5C105 Chassis 3-4 Insta llation Figure 3-1 Installing a Module int o the 5C105 Chassis SERIES E5 45 PS1 PS2 1 23 Backplane Connector Metal Back-Panel Circuit Card Car.
Connecti ng to the Ne twork Install ation 3-5 6. Locate t he slot guides t hat line up with the number of the s lot in which the m odule will be instal led.
Connectin g to the Networ k 3-6 Insta llation Figure 3-2 Connecting a T wisted P air Segment to the 5H1 02-48 3. Verify t hat a link exis ts by checking t hat the port RX (Rec eive) LED is ON (fla shing amber, blinki ng green, or soli d green).
Connecti ng to the Ne twork Install ation 3-7 Figure 3-3 Crosso ver Cable RJ45 Pinouts Figure 3-4 S traight-Thr ough Cable RJ45 Pinouts e. Ensure tha t the twi sted pair connection meets the dB loss and cable sp ecific ations out lined in the Cabling Gui de.
Connectin g to the Networ k 3-8 Insta llation 3.3.2 Connecting UTP Cabl es to the 5H103-48 When fa cing the front p anel of the 5H1 03-48, the RJ21 conne ctors from top t o bottom repre sent Etherne t/Fast Ethe rnet se gments 1 through 12, s egments 13 through 24, 25 thr ough 36, and 37 through 48, respecti vely .
Connecti ng to the Ne twork Install ation 3-9 Figure 3-6 Connection Using the RJ21 Angle Adapter Figure 3-7 Example of Cable Placement When U sing the RJ21 Angle Adapters 2229-01 RJ21 Adapter/Extender.
Completin g the In stallati on 3-10 Insta llation 3. Tighten the two screws on t he RJ21 connect or, as applicabl e, to secure it to the module. If usi ng the RJ2 1 angl e adapter , plug in the RJ 21 right- angle d connecto r until the tw o retai ning clips, shown in Figure 3-7 , snap into place .
T roubleshooting 4- 1 4 T r oubleshooting This chap ter pro vides informati on concerning the followi ng: • Using LANVIEW ( Secti on 4.1 ) • T roubleshoo ting Checklis t ( Section 4 .2 ) • Using the RESET Button ( Sectio n 4.3 ) 4.1 USING LANVIEW The module s use a b uilt-in vi sual diagnosti c and status moni toring sys tem calle d LANVIEW .
Using LANVIEW 4-2 T roublesh ooting Figure 4-1 LANVIEW LEDs (both modules) Ta b l e 4 - 1 describes the LED indicati ons and provid es recommended ac tions as appropr iate. NOT E: The ter ms flashing , blinking , and solid used in Ta b l e 4 - 1 i ndicate the following: Flashing indica tes an LE D is flashi ng randomly .
Using LA NVIEW T roublesh ooting 4-3 T ab le 4-1 LANV IEW LEDs LED Color Stat e Recomme nded Action CPU Of f Po wer off . Ensure c hassis has adequa te po w er . Red Solid . Hardwa re fail ure has occur red. If the LED remains red f or se veral minutes, contact Ente rasys Networ ks for techni cal support.
Using LANVIEW 4-4 T roublesh ooting TX (Transmit) Off Port enabled, and no acti vity . Should fl ash green e very two seconds i ndicating BPDUs being sen t if ST A is enabl ed and there is a va l i d l i n k . 1. Ensure tha t the STA is ena bled and that there is a valid link .
T roublesh ooting Che cklist T roublesh ooting 4-5 4.2 T ROUBLESHOOTING CHECKLIST If the module is not w orking pr operly , refer to Ta b l e 4 - 2 for a ch ecklist of problems, possibl e causes, a nd recommended ac tions to resolv e the pro blem. T able 4-2 T roubleshooting Checklist Prob lem P o ssible Cause Recommended Action All LEDs are OFF .
T roubleshooting C hecklist 4-6 T roublesh ooting Cannot cont act the module through in -band management. IP address not assigned. Refer t o the MA TRIX E5 Serie s Modules Local Mana gement User’ s Guide for the IP address assignment proce dure. Port is di sabled.
Using the RE SET Button T roublesh ooting 4-7 4.3 USING THE RESET BUTTO N The RESET b utton sho wn in Figure 4- 2 resets a nd re-initial izes the modul e. Figure 4-2 RESET Button (both modules) T o reset the module processor , press and release the RESET butt on.
.
Specif icatio ns A-1 A Spe cifi cations This appe ndix prov ides operating s pecific ations for t he 5H102-48 and 5H103- 48 modules. Ente rasys Network s rese rves the right to cha nge th e spe cificat io ns at a ny time w it hout n otice . If not spec ified by module na m e, the s tatistics ar e the same for bot h modules.
Input/Outp ut P or ts A-2 Specif ications A.4 INPUT/OUTPUT P OR TS 5H102-48: 5H103-48: A.5 COM P ORT PINOUT ASSIGNMENTS The COM port is a serial communi cati ons port that supp orts Loc al Management . Ta b l e A - 1 sho w s the COM por t pin ass ignments.
Regulator y Complia nce Specifi catio ns A-3 A.6 REGULATORY COMPLIANCE The 5H102-48 and 5H103-48 mo dules meet the fol lowing sa fety and ele c tromagnetic compat ibility (E MC) requireme nts: Safety : UL 1950, CSA C22.2 N o. 950, 73/23/EEC, EN 60950, IEC 950, EN 60825 Electr omagnetic Compatibi lity (EMC): FCC Part 15, CSA C108.
.
Mode Swi tch Bank Settings and Opti ons B-1 B Mode Switch Bank Settings an d Options This appe ndix cov ers the foll owing i tems: • Required tools ( Section B.
Setting th e Mode Switches B-2 Mode Swi tch Bank Settings and Opti ons B.2 SETTING THE MO DE SWIT C HES Figur e 2 -1 s h o ws t h e locati on of the mo d e switches an d the switch setti n gs f or normal o perat io n . T h ese switc h e s are set at the f actor y and rarel y need t o b e cha n ged.
Setting th e Mode Switches Mode S witch B ank Sett ings and Options B-3 • Switch 6 – No function. • S witch 7 – Clear NVRAM. Changing t he position of t his switch rese ts NVRAM on the ne xt po wer -up of the de vice. All user-e ntered para meters, suc h as the IP ad dress, de vice names, e tc.
.
Index-1 Inde x Numerics 100BASE-TX requirem ents 2-2 10BA SE-T connection 3-5 , 3-8 requirem ents 2-1 802.1 p Port Prio rity introduction to 1-4 A Auto-Negot iation 1-3 C Cable connections 5H10 2-48 3.
Index-2 P Physical pr operties A-1 Pinou ts crossover 3-7 straig ht-t hroug h 3-7 Port redirect functi on introduction to 1-4 Port Trunki ng introduction to 1-3 R Receive LEDs viewing of 4-1 Redirect .
Een belangrijk punt na aankoop van elk apparaat Enterasys Networks 5H103-48 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Enterasys Networks 5H103-48 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Enterasys Networks 5H103-48 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Enterasys Networks 5H103-48 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Enterasys Networks 5H103-48 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Enterasys Networks 5H103-48 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Enterasys Networks 5H103-48 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Enterasys Networks 5H103-48 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.