Gebruiksaanwijzing /service van het product PRIMERGY RX200 S6 van de fabrikant Fujitsu
Ga naar pagina of 28
PRIMERGY RX2 00 S6 System configurator and order-information guid e Contents 4x or 6x 2.5" Hot-plu g HDD or SSD 8x 2.5" Hot-plug HDD or SDD Instruc tions Configuration diagram Configurator 0 System softw are I Basic unit II Processor III Memory IV Graphics V Accessible drives G-VI Drive Bay for 6x 2.
System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Instructions This document c ontains basic product and configuration information that will enable you to configure your system via PC-/SystemArchit ect.
System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Configuration diagra m PRIMERGY RX200 S6 Sy st em unit (I) board front side Memory CPU1 right side (Channe l A + B + C) A cc essible drives (V) Bank 1 (3 Modules) Bay for 5,25"x 0,5" SATA-DVD Bank 2 (3 Modules) Only with option 6x 2.
PRIMERGY - Softw are Co nfigurato rs and Release Lists Start PRIMERGY RX 200 S6 PRIMERGY RX200 S6 S tatus 201 1-10-30 SW Configurator 32 bit with OEM -Software without OEM-Softw are for PRIMERGY Serve.
PRIMERGY-Softwa re Configur ators and Release Lists Start PRIME RGY RX2 00S6 PRIMERGY RX 200 S6 Status 2011-1 0-30 SW Con figurator 64 bit (EM64T / IA6 4) w ith OEM-Softw are w ithout OEM-Softw are fo.
System c onfigurator and order-inf ormation guide Start PRIMERGY RX200 S6 PRIMERGY RX200 S6 Status 2011-10-30 Section I Basic u n it System u nit con sistin g of: * 1U Hou sin g in clu din g - power cord rack 4m len gth (PSU has to b e config ured min 1x) * Fan s - Redun dant a nd ho t plug system fans ( 6x ) * Drive s / Bays - 6x 2.
System c onfigurator and order-inf ormation guide A PRIMERGY RX200 S6 Status 2011-10-30 In terfac es at th e re ar: * 1x RS-232-C (seria l, 9 pi ns) (usable for BMC or OS or sha red) * 1x VGA (15 pin s): If Front-VGA is used , then Rear-VGA is disabl ed * 3x USB 2.
System c onfigurator and order-inf ormation guide B PRIMERGY RX200 S6 Status 2011-10-30 Rack v ersi on for 19'' rac ks w ith NO PSU incl ude d in Base Un it No Rack-mo un tin g kit i ncl ude.
System c onfigurator and order-inf ormation guide C PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F2735 -E101 S26361 -F2735 -E110 S26361 -F2735 -E111 S26361 -F2735 -E140 RMK-F1_1-2U Server RMK-P_1-2U Se.
System c onfigurator and order-inf ormation guide D PRIMERGY RX200 S6 Status 2011-10-30 Section II Processor There a re 2 pro cessor sockets available.
System c onfigurator and order-inf ormation guide E PRIMERGY RX200 S6 Status 2011-10-30 Section III Memory - There a re 6 me mory slots for m ax. 9 6GB registere d (reg) DDR3 RA M per CPU av aila ble w ith 1 6GB RDIMMs or max. 12GB u nbu ffere d (ub ) DDR3 RA M per CPU av aila ble w ith 2GB UDIMMs => max.
System c onfigurator and order-inf ormation guide F PRIMERGY RX200 S6 Status 2011-10-30 For a des cription of me mory con figu ration s refer to section "Mem ory Configu ration s" Minimum one memory modu le or memory order code per CPU = first memory Registered (reg) RDIMMs (1.
System c onfigurator and order-inf ormation guide F1 F2 PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F3284 -E1 S26361 -F3284 -E2 Spare Ch an ne l Mode I n stallati on Performan ce Mode In sta llation W.
System c onfigurator and order-inf ormation guide G1 G2 PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F3284 -E3 Mirrored Cha nn el Mode In sta llation W ith thi s order code a BI OS setup for Mirrored C.
System c onfigurator and order-inf ormation guide PRIMERGY RX200 S6 Status 2011-10-30 Section IV Graphic s Graphics Control ler in tegrate d in i RMC S2 (integ rated Re mote Manag ement Con troller): .
System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 Memory Configuration PRIMERGY RX200 S6 Each CPU of fers 6 Slots fo r DDR3 Memo ry Modules organised in 2 Ba nks and 3 Channe ls. If you need m ore than 6 Slots you ha ve to configu re the 2n d CPU.
System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 Used CPU Dual-Core CPU with max. 800MHz DDR3 spee d (4.8GT/s) Xeon E5503 2C/2.00 GHz/2M/4,80GT/s (80W ) Quad-Core CPU`s with max. 800MHz DDR3 spee d (4.8GT/s) Xeon E5506 4C/2.
System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 1. Independent Channel Mode required required if 2 nd CPU is config ured Bank I Data Data Data Data Data Data.
System c onfigurator and order-inf ormation guide I PRIMERGY RX200 S6 Status 2011-10-30 Section V Accessible drives Setup RX200 S6 by ServerStart is supporte d with foll owing confi gurati ons: no Flo.
System configurator and order-infor mation guide J PRIMERGY RX 200 S6 Status 2011-1 0-30 Section G-VI Drive Bay for 6x / 8x 2.5" HD Ba sic Unit Base Unit S2636 1-K134 2-V10 1 Drive Bay w ith u p to 6x 2.5" HDDs plu s on e ba y for DVD On ly 4 HDD Po rts are conn ected to a RAID Con t roll er.
System configurator and order-infor mation guide J1 PRIMERGY RX 200 S6 Status 2011-1 0-30 J2 Section G-VIII 4x / 6x / 8x 2 .5" SA S / SAT A Ha rd disk drive s Section G- IX 4x 2.5" S ATA Ha rd disk drives For basic u n its V1x x u p to 6x SA TA / SAS 2.
System configurator and order-infor mation guide L PRIMERGY RX 200 S6 Status 2011-1 0-30 Section X External SA S Dis k Array , SAS back up drives or SCSI periphe ral device s External 8-po rt SAS-co n.
System configurator and order-infor mation guide M PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XI Fibre Chan nel Fibre Chan nel Controller for externa l storage sy stems S263 61-F33 06-E2 01 S263 61.
System configurator an d order-information gu ide N PRIMERGY RX 200 S6 Statu s 2011-10-30 Section XII Communicat ion / Network 2x 1GBit on-b oard LAN Cont roller Teaming: Failov er, Load Balancing Gig.
System configurator an d order-information gu ide N1 PRIMERGY RX 200 S6 Statu s 2011-10-30 F) InfiniBan d HCA's S26361-F4475-E102 S26361-F4475-L102 IB HCA 40Gb 1 port QDR for loo se deli very IB HCA 1x 40Gb PCIe 2.
System configurator and order-infor mation guide O PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XIII System Mana gemen t Products (Re moteView) S263 61-F17 90-E2 41 iRM C S2 (in t egrated Remote M an.
System configurator and order-infor mation guide P PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XVI Energy Star S263 61-F33 01-E4 01 RX200 S6 E-Star Fa m1 Limits con figu ration in accorda n ce wi th E ne rgy Star requ iremen ts max.
System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Change Report Date Order number Changes 2011-1 0-30 S26361 -F4541-Ex00 new SAS SSD with 100 , 200, 400 GB add ed .
Een belangrijk punt na aankoop van elk apparaat Fujitsu PRIMERGY RX200 S6 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Fujitsu PRIMERGY RX200 S6 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Fujitsu PRIMERGY RX200 S6 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Fujitsu PRIMERGY RX200 S6 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Fujitsu PRIMERGY RX200 S6 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Fujitsu PRIMERGY RX200 S6 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Fujitsu PRIMERGY RX200 S6 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Fujitsu PRIMERGY RX200 S6 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.