Gebruiksaanwijzing /service van het product LF1600 van de fabrikant Graham Field
Ga naar pagina of 16
LF1600-INS-LAB-RevB07 © GF Health Products, Inc. December 2007 LF1600 Stand Assist user and attendant: Read this manual before operating the Stand Assist.
2 LF1600-INS-LAB-RevB07 • LF1600 Stand Assist CONTENTS 1 INTRODUCTION ........................................................................................................ 3 ST A TEMENTS OF SIGNIFICANCE ...........................................
LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 3 1 INTRODUCTION Important safety , operating, and maintenance instructions that warrant your atten- tion ar e included in this manual.
4 LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 2 IMPOR T ANT SAFETY PRECAUTIONS Impor tant safety pr ecautions: Always follow these safety pr ecautions when using your LF1600 Stand Assist. Failur e to do so could r esult in personal injur y to you or others or damage to your Stand Assist.
LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 5 3 HANDLING AND ASSEMBL Y HANDLING GF Health Pr oducts, Inc. Fr eight Policy—For Y our Pr otection, Read Car efully: The carrier accepted this mer chandise “in good condition” and is responsible for safe deliver y .
6 LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 3. Kneepad assembly (shown at right) 4. T wo seat pad and handle bar support units and two cr oss bar tubes (shown at right) 5.
LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 7 ASSEMBL Y T ools required: provided wrench, provided hex key back casters base assembly 1. Place the base assembly on the oor and lock the back casters for ease of assem- bly , as shown above. flat washer lock washer hex bolt plastic cap kneepad kneepad support unit kneepad assembly 2.
8 LF1600-INS-LAB-RevB07 • LF1600 Stand Assist carriage bolt kneepad assembly kneepad side support assembly side support arm flat washer lock washer acorn nut kneepad assembly side support arm 3. Attach the kneepad assembly to the two side support arms.
LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 9 base bracket kneepad side support assembly kneepads lockable casters 5. Insert the kneepad side suppor t assembly into the base brackets as shown above. The kneepads and arm cur vature should be facing away fr om the lockable casters.
10 LF1600-INS-LAB-RevB07 • LF1600 Stand Assist carriage bolt base assembly kneepad side support assembly seat and cross bar assembly flat washer lock washer acorn nut a a b c c b 7. Fasten the seat and cr oss bar assembly , kneepad side support assembly , and base assembly together with carriage bolts: a.
LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 11 4 OPERA TION Note: Patients who desire additional security may wish to use the optional DSLSA9 Sit-to-Stand Buttock Strap, available through your Graham-Field dealer .
12 LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 5. Lower both of the split seat units down into position to form a complete seat, as shown at right. W ARNING: Ensure that both seat units are lowered and form a complete seat before having the patient sit down on the Stand Assist.
LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 13 5 MAINTENANCE T o ensur e safety and proper use, perform the following steps monthly: • Check all fasteners to ensur e that they are secur ely fastened and no wear and tear is evident. Replace and tighten any worn fasteners befor e using the Stand Assist.
14 LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 6 LIMITED W ARRANTY This warranty has been drafted to comply with the Federal Law applicable to pr od- ucts manufactur ed after July 4, 1975. This warranty is extended only to the original pur chaser/consumer or dealer/non-consumer who does not buy for resale and to no other pur chaser or transferee.
LF1600-INS-LAB-RevB07 • LF1600 Stand Assist 15 7 INDEX C Caution statement, signicance 3 Cleaning 13 Components 5 H Handling 5 I Inspection 5 Intended use 3 Introduction 3 M Maintenance 13 N Note.
Corporate Headquar ters: GF Health Pr oducts, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 U.S.A. telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 www .grahamfield.com GF, Graham-Field, and Lumex are register ed trademarks of GF Health Pr oducts, Inc.
Een belangrijk punt na aankoop van elk apparaat Graham Field LF1600 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graham Field LF1600 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graham Field LF1600 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graham Field LF1600 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graham Field LF1600 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graham Field LF1600 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graham Field LF1600 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graham Field LF1600 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.