Model 1645 Receiver Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics model 1645 Receiver. Receivers are designed as the remote control device for operation of a motorized pan/tilt unit and a motorized lens unit.
The software/firmware furnished with this equipment is confidential to and is copyrighted by AMERICAN DYNAMICS. It is not to be copied or disclosed in any manner without the express written consent of AMERICAN DYNAMICS.
QA303C This product generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception.
T able of Contents Description............................................................................ 1 Features ................................................................................. 1 Installation ....................................
DESCRIPTION The 1645 Receiver is a single channel receiver for control of motorized pan/tilt and lens units used with Matrix Switching Systems. The 1645 is used with the American Dynamics 1237VS or Vi.
INSTALLATION This installation should be made by a qualified service person and should conform to all local codes. Safeguards must be taken to avoid unintentional operation by employees and personnel working about the premises, by falling objects, by customers, by building vibration, and by similar causes.
SETUP Camera Number Assignment For individual control of camera Pan/Tilt actions by the Matrix Switching System, a camera number must be associated with each Receiver. A 10-position DIP switch labeled “CAMERA ID” is used to associate a particular camera number with the Receiver.
SETUP 4 Code Terminal Connector Auxiliary and Preposition Connector CAMERA ID Pan/Tilt and Lens Connector POWER LED CODE LED LENS ADJ Power cord Control Code Receiver Module PCB J6 on Main PCB R3 T1 C.
RS-232 Receiver (1645S) Setup In order to receive RS-232 code, the S1 and S2 DIP switches on the RS-232 Receiver Module must be set to the following positions. See Figure 5 below for location of these DIP switches on the 1645S Receiver Module PCB. DIP Sw.
CONNECTIONS Code Line Connections for Control Code (model 1645M) The Code Terminal Connector, J1, is a 3-position terminal connector located on the side of the unit (see Figure 4, page 4). The terminal is marked W (white code), S (shield), and B (black code).
Code Line Connections for RS-232 (1645S Series) Matrix Switching Systems, RS-232 keyboards, modems, and other RS-232 compatible devices, are connected to the RS-232 connector of the 1645S. The RS-232 Terminal Connector, J3, is a 6-pin connector located on the side of the 1645S (see Figure 5, page 5).
Pan/Tilt and Lens Cable The connection to a Pan/Tilt and a motorized Lens is with a 12-pin connector. This connector (J6) is located on the side of the unit, near the Camera ID DIP switch (see Figures 4 and 5, pages 4 and 5).
Auxiliary and Preposition Cable The connection of auxiliary equipment and preposition servos is with a 14-pin connector. This connector (J7) is located on the side, near the Code Line Connector (see Figures 4 and 5, pages 4 and 5).
OPERATION Powering Up The 1645 Receiver is supplied for the following power sources: 1645M,1645S 120VAC, 50/60Hz 1645MX,1645SX 230VAC, 50/60Hz The 1645 Receivers are shipped with a pendant cord and wall plug for use with an electrical outlet. Plug the cord to the required voltage source according to the model.
Appendix.
.
Camera Identification DIP Switch Settings 0 = Off 1 = On 1645M models, set switch positions 7-10 Off; 1645S models, set the switches in the shaded section of the table Appendix Camera Switch Position .
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 1 2 9 00 0000 1 3 0 10 0000 1 3 1 01 0000 1 3 2 11 0000 1 3 3 00 1000 1 3 4 10 1000 1 3 5 01 1000 1 3 6 11 1000 1 3 7 00 0100 1 3 8 10 0100 .
Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 257 0 0 0 0 0 0 258 1 0 0 0 0 0 259 0 1 0 0 0 0 260 1 1 0 0 0 0 261 0 0 1 0 0 0 262 1 0 1 0 0 0 263 0 1 1 0 0 0 264 1 1 1 0 0 0 265 0 0 0 1 0 0 266 1.
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 385 0 0 0 0 0 0 386 1 0 0 0 0 0 387 0 1 0 0 0 0 388 1 1 0 0 0 0 389 0 0 1 0 0 0 390 1 0 1 0 0 0 391 0 1 1 0 0 0 392 1 1 1 0 0 0 393 0 0 0 1 .
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 5 1 3 0 0000 0 5 1 4 1 0000 0 5 1 5 0 1000 0 5 1 6 1 1000 0 5 1 7 0 0100 0 5 1 8 1 0100 0 5 1 9 0 1100 0 5 2 0 1 1100 0 5 2 1 0 0010 0 5 2 2.
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 641 0 0 0 0 0 0 642 1 0 0 0 0 0 643 0 1 0 0 0 0 644 1 1 0 0 0 0 645 0 0 1 0 0 0 646 1 0 1 0 0 0 647 0 1 1 0 0 0 648 1 1 1 0 0 0 649 0 0 0 1 .
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 769 0 0 0 0 0 0 770 1 0 0 0 0 0 771 0 1 0 0 0 0 772 1 1 0 0 0 0 773 0 0 1 0 0 0 774 1 0 1 0 0 0 775 0 1 1 0 0 0 776 1 1 1 0 0 0 777 0 0 0 1 .
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 8 9 7 00000 0 8 9 8 10000 0 8 9 9 01000 0 9 0 0 11000 0 9 0 1 00100 0 9 0 2 10100 0 9 0 3 01100 0 9 0 4 11100 0 9 0 5 00010 0 9 0 6 10010 0 .
TYPICAL SYSTEM CONNECTIONS 1645 to 1237VS Pan/Tilt 1237VS PAN/TILT 1645 RECEIVER 7-Pin 1237VS Connector 123456 7 FOCUS ZOOM IRIS SHIELD + 20 VDC TILT - 20 VDC PAN ALARM 1 ALARM 2 GND COMMON J6.
TYPICAL SYSTEM CONNECTIONS 1645 to 1237VSP Pan/Tilt with Pre-position 1237VSP PAN/TILT AUX2 N/C AUX1 COM AUX1 N/O TILT POT SHIELD ZOOM POT FOCUS POT - REF PAN2 POT PAN1 POT + REF AUX1 N/C AUX2 N/O AUX.
TYPICAL SYSTEM CONNECTIONS 1996 Controller to 2091 Code Generator, to 1645M (Control Code) 1645M 2091 1996 ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF B W S B W S B W S B W S B W S B W S B.
TYPICAL SYSTEM CONNECTIONS 2150 Controller to 1645M (Control Code) MAXIMUM DISTANCE between 1645 and 2150 is 5000 Ft, using shielded, 18 AWG cable 2150 1645M BW S RS232 PORTS 123 KEYBOARDS 2345 CAMERA.
TYPICAL SYSTEM CONNECTIONS 1676 Keyboard to 1645S (RS-232 Connection) HP0047 TERMINAL BOX JJ0007 Cable BROWN (GRD) RED (RCD) GREEN (XMIT) 1645S 4 1676 TP8059 Wall Transformer T + T - R + R - CODE POWE.
TYPICAL SYSTEM CONNECTIONS 1983 Code Converter to 1645S (RS-232 Connection) 1983 PSK 120V 60Hz LINE RS232 PHONE 3 2 1 12 11 10 CODE I/O HP0047 TERMINAL BOX JJ0007 Cable BROWN (GRD) RED (XMIT) GREEN (R.
2091 TYPICAL SYSTEM CONNECTIONS 1996 Controller to 2091, to 1645S (RS-232 Connection) 1996 1645S ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF B W S B W S B W S B W S B W S B W S B W S B W S.
An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 (914) 624-7600 Technical Support Center: 1-800-442-2225 FAX: 914-6.
Een belangrijk punt na aankoop van elk apparaat American Dynamics AD1645 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen American Dynamics AD1645 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens American Dynamics AD1645 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding American Dynamics AD1645 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over American Dynamics AD1645 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van American Dynamics AD1645 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de American Dynamics AD1645 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met American Dynamics AD1645 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.