This manual has been provided to assist you with lift installation and operation. For further assistance please contact your authorized Harmar dealer or Harmar’s Technical Service department.
Table of Contents Installing the lift Using the Manual 2 When You Receive the Lift 3 Specifications 3 Safety 3 Code Requirements 4 Site Requirements 4 Required Tools 4 Required Materials 4 Preparing t.
When You Receive the Lift • Check the lift for shipping damage. If you see any dam age contact the freight carrier to file a da mage claim. • Verify the products match that described on the packing list attached to the exterior packaging. • Verify the contents of the package match that shown below to the right.
Code Requirements Your lift has been designed to meet ASME A18.1 section 2 and CSA B44/ASME A17.5, with the addition of certain options. Code requirements for Ve rtical Platform lifts vary depending on location.
Preparing to Install the Lift Final Site Inspection Verify the surface the lift will mount to is smooth and level. This surface m ust be made from 3,500 psi reinforced concrete with a minimum thickness of 4”. Verify that there is enough space for the lifts foot print.
Installing the Platform Step 1 The mounting bolts, nuts and spacers that secure the platform to the lift carriage are packaged in the small parts box. Begin by locating these pieces and setting aside. Step 2 Position the platform by aligning the support legs with the carriage flanges that protrude from the front cover.
Installing the Outer Guard Panels Step 1 Remove the hexbolts on the corners of the platform. Insert the guard panel posts into the pockets in the platform.
Installing Auto-folding Ramp (optional) Step 1 Install the ramp roller guide on the side of the lift tower using the screws already installed in the panels. Step 2 Attach the two ramp pivot tabs to the lower landing sides of the platform. Reinsert the hex bolts, one of which will go through the guard panel post, and tighten.
Anchoring the Lift Anchors Harmar recommends securing the lift using the concrete anchors provided. If you purchase you own floor anchors they must be 3/8” minimum of sufficient length. All four floor anchors must be installed correctly in accordance to their instructions.
Setting the Limit Switches Your lift is equipped with upper and lower limit switches. The vertical location of these switches may be adjusted to fit your application. Typically the upper lim it swit ch will need to be adjusted so the platform will stop level with the upper landing.
Verifying Operation of the Lift Caution: Complete the following section before training the customer to use the lift. Step 1 Run the lift up and down for 5 complete cycles. Hold the direction button down and allow the limit switches to stop the lift. At the top, verify that the platform stops level with the upper landing.
Manual Override Your lift is equipped with a manual handcrank, to be used in the case of a power failure. Step 1 Before using the manual handcrank verify that it’s use is required. Check that the emergency stop switch is pulled out. Check that the electrical cord is connected to the supply.
Top Landing Gate (optional) The optional top landing gate is provided with a combination mechanical lock and electric contact (interlock) . The interlock: • Prevents the lift from running if the gate is not closed. • Prevents the gate from being opened if the platform is not at the top landing.
EMI and Flush Strike Interlocks (optional) The optional EMI or Flush Strike Interlocks are provided with a combination mechanical lock and electric contact. They are to be used with existing doors. The interlock: • Prevents the lift from running if the door is not closed.
Platform Gate (optional) The optional platform gate is provided with a combination mechanical lock and electric contact (interlock) . The interlock: • Prevents the lift from running if the gate is not closed. • Prevents the gate from being opened if the platform is not at the bottom landing.
Fascia Panel (optional) A fascia panel provides a smooth surface for th e platform edge to run against to prevent any shear or obstruction hazards and must be utilized. A running clearance of no more than 3/4” and no less than 3/8” must be maintained between the edge of the platform and the fascia panel.
Commercial Platform Lift - Owners Section L Read the manual thoroughly before operating the lift. 17.
Congratulations on the purchase of your Harmar Vertical Platform Lift. This lift has been engineered to provide trouble free se rvice for many, many years. Please read this manual completely before operating your lift. Safety • Do not exceed the maximum payload capacity of 750 lbs.
Controls Emergency Stop In an emergency push this red button to stop the lift. Turn the button clockwise to run. Up Controls upward movement of lift platform. To move platform up, depress and hold the upper half of the rocker switch. To cease movement, release switch.
Operating the Lift Step 1 - Up Drive onto and stop in the middle of the platform. Apply the brakes of your chair or scooter. Step 2 Verify that the emergency stop button is not activated by giving it a quick turn clockwies. Step 3 Press and hold the UP rocker.
Step 1 - Down Drive onto and stop in the middle of the platform. Apply the brakes of your chair or scooter. Step 2 Verify that the emergency stop button is not activated by giving it a quick turn clockwise. Step 3 Press and hold the DOWN rocker. The lift will move in the down direction and stop when it reaches the lower landing.
Please fill out all fields and return within 10 days of product purchase. Toll-Free Fax: 1-866-234-5680, Online: www.harmar.com or Mail to: Harmar Summit, LLC.
Een belangrijk punt na aankoop van elk apparaat Harmar Mobility CPL800 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Harmar Mobility CPL800 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Harmar Mobility CPL800 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Harmar Mobility CPL800 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Harmar Mobility CPL800 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Harmar Mobility CPL800 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Harmar Mobility CPL800 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Harmar Mobility CPL800 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.