1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building.
2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance.
3 TABLE OF CONTENTS Safety and Warning Information ............................................... 2 Service Parts List ...................................................................... 4 Section 1: Approvals and Codes ...........................
4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 5 4 2 1 3 7 Log Set Assembly 15 11 10 12 8 9 14 13 6 18 16 19 17 (NG , LP) Exploded Parts Diagr.
5 S ervice Parts List / Liste des pièces de rechange ITEM / P IÈCE COMMON PARTS / PIÈCES COMMUNES PA RT NUMBER / N° DE PIÈCE ON/OFF Rocker Switch / Int errupteur à bascule marche/arrêt 060-511 .
6 Appliance Certification The fireplace model discussed in this Installers Guide has been tested to certification standards and listed by the applicable laboratories. Certification MODEL: QV36D LABOR ATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace STANDARD: ANSI Z21.
7 Introducing the Quadra-Fire Gas Fireplace Quadra-Fire direct vent gas fireplaces are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. The information contained in this Installers Guide , unless noted otherwise, applies to all models and gas control sys- tems.
8 Figure 1. Diagram of the QV36D 41 1/8 [1044mm] 38 [965mm] 36 1/8 [916mm] 25 1/4 [642mm] 34 5/8 [879mm] 8 5/8 [219mm] VENT COLLARS ELECTRICAL ACCESS 26 7/8 [682mm] 12 3/4 [323mm] 3 1/2 [90mm] GAS LIN.
9 Installing the Fireplace Step 1. Locating the Fireplace For space and clearance requirements for locating a fire- place within a room see Figure 2. ABCD E 42” 22” 36” 51” 72” For minimum clearances, see the direct vent termination clearance diagrams on pages 24 and 25 in this manual.
10 Framing should be constructed of 2 X 4 lumber or heavie r. A . ............. 42”* B . ......... 38 1/2” C . ............... 22” D . ............... 42” E . ......... 27 7/8” Figure 3. Framing Dimensions Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is set in place.
11 NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOIN T. Figure 4. D-Series Direct Vent Component Specifications (5-inch inner pipe / 8 5/8-inch outer pipe) DV-36D 5 3/4” (146mm) 8 3/4” (222m.
12 Figure 5. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals This model is approved to use D-series direct vent pipe components and terminations (see Figures 4 and 5). Ap- proved vent system components are labeled for identifica- tion.
13 Figure 6. Straight Up Vertical Venting STRAIGHT UP VERTICAL VENTING V (FT .) 40' MAX. (12.4 M) CAP V Flue Restrictor Instructions 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7).
14 HORIZON TAL VENTING Kit No. H Max. Run DVK-01TRD 24" (610 mm) Figure 10. Corner Installation NOTE: T his model is tested and approved to use 45 ° elbows in corner installations. Howeve r , 90 ° elbows will result in better performance. 45-DEGREE ELBOW 90-DEGREE ELBOWS H 3.
15 Figure 12. Venting with One 90° Elbow NOTE: If a 90 o elbow is first attached to the unit, the maximum horizontal run is 3-feet (914mm). VENTING WITH ONE (1) 90° ELBOW V (F T .) H (F T .) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX.
16 VENTING WITH TWO (2) 90 o ELBOWS V FT . H + H 1 (FT .) 1' MIN. ( 305mm) 5´ MAX. (1.52 m ) 2' MIN. (610mm) 10´ MAX. (3.1 m ) 3' MIN. (914mm) 15´ MAX. (4.65 m ) 4' MIN. (1.22m) 20´ MAX. (6.2 m ) V+H+H 1 = 40' MAX.(12.4m) H+H 1 = 20´ MAX.
17 Figure 15. Venting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX. (2.
18 VENTING WITH THREE (3) 90° ELBOWS V (F T .) H (F T .) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) NOTE: H + H 1 = 20' MAX.
19 Figure 17 B. Inst alling V ent Component s After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly . V enting Out the Rear V ent Remove the installed rear seal cap from the rear starting collars by cutting the strap at each end.
20 2. Continue Adding V ent Component s W ARNING: INST ALLA TION OF THIS FIRE- PLACE REQUIRES THE USE OF A HEA T SHIELD ABOVE THE FIRST 90 0 ELBOW IN THE VENTING SYSTEM. Figure 19 T o Install the Heat Shield: 1. Determine if the heat shield is required.
21 For Vertical Runs - The vent system must be supported every eight (8) feet (2.4m) above the fireplace flue outlet by wall brackets. To install support brackets for vertical runs: • Attach wall brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws.
22 For Vertical Runs - One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes. To install firestops for vertical runs that pass through ceilings: • Position a plumb bob directly over the center of the verti- cal vent component.
23 ! C. Vent Termination For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent: • Rotate and interlock the ends as described at the begin- ning of the Installing Vent Components section. • The termination kit should pass through the wall firestops from the exterior of the building.
24 ______________________________________________________________________ ______________________________________________________________________ _______________________________________________________.
25 For Vertical Terminations - To locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint. • Make the outline of the roof hole around the centerpoint nail.
26 Step 4. Positioning, Leveling, and Securing the Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, such as sheet metal, as necessar y.
27 Figure 34. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration.
28 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENT AL FIREPLACE OPERA TION. • This appliance DOES NOT require 110-120 VAC to operate.
29 Step 9. Finishing Figure 37 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances.
30 Installing the Trim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F .
31 Step 11. Lighting the Appliance STANDING PILOT IGNITION A. This appliance (standing pilot version) has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactl y. B. BEFORE LIGHTING smell all around the appli- ance area for gas.
32 Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety warnings and cautions • Read the Safety and Warning Information section at the beginning of this Installers Guide .
33 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season.
34 Troubleshooting W ith proper installation, operation, and maintenance your gas fireplace will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken.
35 Symptom Possible Cause Corrective Action 3. (Co nt inued) f. H ig h l imit switc h is defecti ve or has reached its ma x im um temperature. A llow the un i t to cool. I f the burner remains lit after the fireplace warms up, the sw i tch is good. 4.
36 Lifetime Warranty LIMITED LIFETIME WARRANTY The Hearth & Home T echnologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them.
Een belangrijk punt na aankoop van elk apparaat Hearth and Home Technologies QV36D (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hearth and Home Technologies QV36D heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hearth and Home Technologies QV36D vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hearth and Home Technologies QV36D leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hearth and Home Technologies QV36D krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hearth and Home Technologies QV36D bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hearth and Home Technologies QV36D kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hearth and Home Technologies QV36D . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.