Installation and Oper ation Instruc tions Jøtul GI 425 D V Camden Classic Direc t V ent Gas Fireplace Insert WARNING: IF THE INFORMA TION IN THESE INSTRUC- TIONS ARE NOT FOLL OWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CA USING PROP- ERTY D AMAGE, PERSON AL INJUR Y OR LOSS OF LIFE.
2 W elcome to J ø tul... Congratulations on the purchase of your new Jøtul GI 425 DV Camden Gas Fireplace. We at Jøtul are glad you’ve made the decision to warm your hearth with one of our products. We’ve been making fine quality cast iron stoves and fireplaces continuously since 1853.
3 T able of C ontents Specifica tions ............................. 4 Installation & Service T ools .......... 4 General Inf ormation ................... 5 Safety Inf ormation .......................... 6 Installation F ireplace R equiremen ts ...
4 Specifications Input Rates Natur al Gas 26,000 BT U/hr . maximum input 13,000 BTU /hr . minimum input Propane 26,000 BT U/hr . maximum input 13,000 BTU /hr . minimum input Inlet P ressure: MI N M AX Natur al Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kP a) Pr opane: 12.
5 Gener al Information IMPORT ANT : SA VE THESE INSTR UCTIONS. 1. The installation and r epair of this appliance must be done by a qualified service person.
6 Saf ety Inf ormation Due to the high opera ting temperatures this appliance should be located out of traf fic and aw ay fr om furniture, draperies, etc.
7 30 1/4 768 mm 40 1016 mm 5 127 mm 17 432 mm 22 559 mm 21 1/2 546 mm 2 50 mm 13 330 mm 11 289 mm 7 1/2 191 mm 25 635 mm 20 508 mm 1 1/2 38mm 8 1/2 (216 mm) M.
8 Co vering the Fireplace Opening T wo cast iron surround styles ar e available f or the GI 425 Camden fireplace insert . Standard Classic Surround The GI425 Camden includes Surround P anels that will overlap a maximum fireplace opening 39” Wide x 29 1/2” High.
9 Mantel and T rim Clear ance Figure 6. Minimum Mantel Clearances. Measure clear ances from the top and sides of the fireplace cabinet before installa tion of the cast iron surround panels. Hear th Requirements The Jøtul GI425 Camden does not requir e special hearth protec tion.
10 Masonry Fir eplace Installation When installing a GI425 DV Camden gas insert into a masonry fireplace the insert will be vented through dual 3” flexible gas aluminum liners. This co-linear installation includes a pair of 3” flex ducts that run from the insert completely through the e xisting chimney to the termination cap.
11 V enting through a Masonry Fireplace 1. Measure height of the chimney to fireplace opening. Determine if both the intak e and exhaust will be extended to the top of the chim- ney . 2. Use tin snips to cut the appropriate lengths of flex for both the intake and exhaust.
12 Prefabricated Fireplace Installation A fa ctory-built pref abricated fireplace will r equire a few modifications bef o re installa tion of the Jøtul GI425 Camden fireplace insert. Modification Steps: 1. Remo ve any fuel gra te or other components attached attached to the fir ebox.
13 V enting Installation Through a Pref abricated Fireplace 1. Measure height of the chimne y to fireplace opening. Determine if both the intake and exhaust will be extended to the top of the chimney . 2. Cut the appropriate lengths of fle x for both the intak e and exhaust .
14 C onnec ting the Gas Supply Gas Supply Requirements ALL I NS T ALLA TIONS MUS T COMPL Y W ITH LOC AL CODE OR IN TH E ABSENCE OF LOCAL C ODE, MUS T CO M PL Y WITH THE MOST R ECENT EDITION OF TH E NA TIONAL FUEL GAS CODE ANSI Z223.1/NFP A 54 OR CAN-B149.
15 The appliance must be isolated from the gas supply line by closing its individual manual gas shutoff v alve (gas cock) during any pressure testing of the gas supply piping system that is equal to or ex ceeds pressures of 1/2 psig (3.5 kPa). Inlet Pressure MI N M AX Natural Gas: 5.
16 C onv ersion Kit C ontents: #155300 - LP #155303 - NG • 1 R egulator T ower labeled for Propane • 3 R egulator T ower Screws • 1 Burner Orifice (3/32” NG, 1.45 mm LP) • 1 Pilot Orifice (#30 for LP , #51 for NG) • Label A - to be completed and applied to the con trol valv e.
17 T ighten new orifice into the base of the pilot assembly . • R eplace Pilot Hood by pushing it into the base. 5. Replace the Burner Tube: . Slip the end of the tube into the Air Shutter and SLI DE TUBE TO THE RIGHT TO COMPLET EL Y CO VER THE BE S URE TO REMO VE THE BLA CK RU BB ER GASKET FROM THE V AL VE.
18 W all Thermostat Installation Use Jøtul Thermostat #129706 or a 750 millivolt DC two-wire circuit thermostat to automatically con trol your fir eplace opera tion. The thermostat should be placed in the same room as the heater , typically 5’ off the floor .
19 Brick P anel Assembly CAU TION: THESE P ANELS ARE EXTREMEL Y FRAGILE! SUPPORT EAC H PIECE WI TH BO TH HANDS AN D HANDLE TEN DERL Y . Install the optional Brick Panel Kit 155311 befor e placing the Logset . Place the panels in position in the order as numbered in F ig .
20 Logset Assembly This is the heart of your Jøtul GI 425 Camden fireplace. Much time and eff o rt has been devoted to attaining a lively , realistic flame picture while simultaneously achieving ef ficient fuel combus- tion and eff e ctive heat output under a variety of installation conditions.
21 Blower Installa tion 1. R un the 10 ft. power cord out from the fireplace to the nearest grounded power outlet . 2. W ith the Speed C ontrol in either the H I or LO W position, the fan will power on when the firebox comes up to opera ting temperatur e.
22 Flame Appear ance / Air Shutter Adjustment THE GI425 GAS FI REPLACE IS SH I PPED FROM THE F ACT OR Y EQUI PPED T O USE NA TURAL G AS . IF TH E BURN ER HAS BEEN CONVER TED FOR USE WITH PROP AN E, IT WI LL BE N EC ESSARY T O ADJUST THE AI R SHUTTER ON THE BUR NER TUB E T O ACHI EVE THE PROPER GAS T O AI R MIX.
23 CLOSED OPEN Figure 26. Proper flame pattern. Air Shutter Adjustment 1. Open the Lower Grill panel and locate the Air Shutter adjustment stem extending down from the firebo x floor . See fig . 27. 2. L oosen the wingnut and pull the stem t o the forwa rd to open the air inlet and allow more air into the burner .
24 Oper ation 1. Y our GI425 gas fireplace can be operated manu- ally using the On/Of f /T -stat rocker switch or it can be automatically con trolled using an optional wall-mounted thermosta t and/ or remote control device. A separa te switch is provided for the optional for ced air blower kit .
25 Figure 30a. GI425 Controls - Burner C ontrol and Blower Switch. ON OFF ST A T HI OFF LO Burner C ontrol Blower Function and Speed Con trol Manual Thermostatic or Remote Co ntro l Blower Conr ol Blo.
26 Maintenance Y our Jøtul GI425 Camden gas fir eplace and its venting system should be inspected bef ore use and at least annually by a qualified service technician. IMPORT ANT : ALWA Y S TURN OFF THE GAS SUPPL Y T O THE FIREPLACE AND UNPL UG THE FORCED AIR BL OWER BEFORE ANY SER- VICE WORK IS PERFORMED ON THE FIRE- PLACE.
27 Glass Panel or Gask et Replacement 1. W rap the new gasketing material ev enly around the edge of the glass, peeling back the protective strip to expose the adhesive as y ou go. Press the adhesiv e side down onto the glass sur face. Do not stretch the gasket .
28 1 2 3 8 10 26 28 12 22 23 24 18 19 11 13 15 22 Jøtul GI 425 D V Camden Classic lllustr ated P ar ts Break down 29 a b c d 32 37 38 33 34 36 35 39 21 14 31 30 21 27 25 16 4 5 6 7 17 76 76 76 9 17 7.
29 No. Description Part Number Use only genuine Jøtul Replacement Parts av ailable from your local Authorized Jøtul Dealer or by contacting: Jøtul North America 400 Riverside A ve. Portland, ME 04104 207 797-5912 EXT 108 Jøtul GI425 Camden P ar ts List No.
30 SERVICE LOG : First Year Name of Technician________________________ Company Name____________________________ Date of service_____________________________ Work Per- formed___________________________.
31 7. Push in gas c ontrol knob sligh tly and turn counter - clockwise to “PILO T” . 8. P ush in control knob all the wa y and hold in. Immediately light the pilot by triggering the spark ignitor (push the red button r epeatedly) until pilot lights.
32 This appliance must be installed in conformance with local and national building r egulations. Before beginning the installation, it is impor tant that the these instructions be carefully read and understood. Jøtul pursues a policy of continual pr oduct development.
Een belangrijk punt na aankoop van elk apparaat Jotul Jtul GI 425 DV (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Jotul Jtul GI 425 DV heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Jotul Jtul GI 425 DV vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Jotul Jtul GI 425 DV leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Jotul Jtul GI 425 DV krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Jotul Jtul GI 425 DV bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Jotul Jtul GI 425 DV kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Jotul Jtul GI 425 DV . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.