Gebruiksaanwijzing /service van het product Interface Port AXB-IRS4 van de fabrikant AMX
Ga naar pagina of 22
instruction manual AXlink Bus Controllers AXB-IRS4 IR/Serial Interface (4 P orts).
AMX Limited W arranty and Disc laimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Co.
T able of Contents i AXB-IRS4 IR/Serial Interface (4 P o rts) T able of Contents Product Information ........ ................ ................. ................ .............. .............. ............ 1 Specifications .............................
ii AXB-IRS4 IR/Serial Interface (4 Ports) T able of Contents.
Product Information 1 AXB-IRS4 IR/Serial Interface (4 P o rts) Pr oduct Inf ormation The AXB-IRS4 (FIG. 1) is an AXCESS bus de vice you can program to cont rol up to four infrared (IR) or serial-controlled audiovisual de vices such as televis i ons and video cassette recorders.
Product Information 2 AXB-IRS4 IR/Serial Interface (4 Ports) AXB-IRS4 Specificati ons (Cont.) PWR co nnector 2-pin captive wire connector connec ts an external 12 VDC power supply to the AXB-IRS4.
Configuration and Installation 3 AXB-IRS4 IR/Serial Interface (4 P o rts) Configuration and Installation Setting the Device DIP Swi t ch The 8-position DEVICE DIP sw itch sets the AXlink identification number for the AXB-CAM. Make sure the de vice number matches the numb er assigned in the AXCESS software program.
Configuration and Install ation 4 AXB-IRS4 IR/Serial Interface (4 Ports) P ositions 1-4: Carrie r signal enable/disab le DIP Swit ch positio ns 1-4 on the CARRIER/B A UD DIP switch determine wether the AXB-IRS4 transmits carrier signals along with the IR equipment codes .
Configuration and Installation 5 AXB-IRS4 IR/Serial Interface (4 P o rts) Setting the Internal J umpers (E1 and E2) f or AXlink or RS-232 Comm unication Internal jumpers are located on th e circuit card inside the AXB-IRS 4 enclosure. Y ou will need a Phillips-head scre wdriver to open the enclosure.
Configuration and Install ation 6 AXB-IRS4 IR/Serial Interface (4 Ports) Wiring the AXB-IRS4 The serial, IR, AXlink, and power supply connectors are located on the rear panel of the AXB-IRS4 as sho w n in FIG. 5. The AXlink connector can also be used for RS-232 communications.
Configuration and Installation 7 AXB-IRS4 IR/Serial Interface (4 P o rts) Using AXlink for data and powe r Connect the Central Controller's AXlin k connector to the AXlink/RS-232 connector , on the rear panel of the AXB-IRS4, for data and 12 VDC power , as shown in FIG.
Configuration and Install ation 8 AXB-IRS4 IR/Serial Interface (4 Ports) FIG. 8 shows the AXlink/RS-232, DB-9, and power supply wiring diagram. For some applications, you may need to strap pins 7 (request to send) and 8 (clear to send) together dependin g on the PC (as shown in the illustration).
Configuration and Installation 9 AXB-IRS4 IR/Serial Interface (4 P o rts) Connecting an IR de vice IR devices connect to the AXB-IRS4 with an IR device cable. The cables supplied with the AXB- IRS4 are designed to accommodate the IR de vi ces in your system.
Configuration and Install ation 10 AXB-IRS4 IR/Serial Interface (4 Ports) Contact your AMX dealer before y ou replace the lithium battery and verify that the y have a current copy of the AXCESS pro gram for your AXB-IRS4. This will av oid any inadvertent loss of data or a service outage.
Programming 11 AXB-IRS4 IR/Serial Interface (4 P o rts) Pr ogramming Channel Setting Commands The AXB-IRS4 channel settings listed in th e following table set IR output channels. The AXB- IRS4 can process up to two IR or serial de vice chann el setting commands simultaneously .
Programming 12 AXB-IRS4 IR/Serial Interface (4 Ports) Send Com mands (C ont.) Command Description 'CH',channel number T ransmit the IR pulses that select the proper chan nel. Enter all channel numbers below 100 as two digits . For ex ample, enter channel 1 as 01.
Programming 13 AXB-IRS4 IR/Serial Interface (4 P o rts) Send Com mands (C ont.) Command Description "'SP',code" T ransmit IR code pulses. Pulse time is set by the CT ON and CTOF com- mands. Va r i a b l e : code = 1-252 Example: SEND_COMMAND 1,"'SP',2" T ransmits a pulse out for command n umber 2 to device 1.
Programming 14 AXB-IRS4 IR/Serial Interface (4 Ports) RS-232 Pr otocol Commands The RS-232 protocol commands listed in the follow ing tables send control signals from an RS-2 32 device to the AXB-IRS4. The follo wing RS-23 2 figur es are grouped together by IR output, channel pulse time, and carrier commands.
Programming 15 AXB-IRS4 IR/Serial Interface (4 P o rts) RS-232 Pr otocol Commands (Channel Pulse Time) RS-232 Pr otocol Commands (Carrier) RS-232 Pr otocol Commands (IR Output - Cont.) Command Description ON[Dev ,Chan] Star t IR outpu t on the designated device and channel.
Programming 16 AXB-IRS4 IR/Serial Interface (4 Ports) RS-232 Pr otocol Commands (Miscellaneou s) RS-232 Pr otocol Commands (Miscellaneou s ) Command Description ECHO OFF Disable the terminal ch aracter's echo function. ECHO ON Enable the terminal character's echo function.
Programming 17 AXB-IRS4 IR/Serial Interface (4 P o rts).
AMX reserves the right to alter specif ications with out no tice at a ny time . brussels • dallas • los ang eles • mexico city • philad elphia • shanghai • singapor e • tampa • toronto * • yo rk 3000 research drive, richardson, TX 75082 USA • 469.
Een belangrijk punt na aankoop van elk apparaat AMX Interface Port AXB-IRS4 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen AMX Interface Port AXB-IRS4 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens AMX Interface Port AXB-IRS4 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding AMX Interface Port AXB-IRS4 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over AMX Interface Port AXB-IRS4 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van AMX Interface Port AXB-IRS4 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de AMX Interface Port AXB-IRS4 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met AMX Interface Port AXB-IRS4 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.