Operation/Reference Guide Custom Panel I nterfaces NXP-CPI16 NetLinx Custom Panel Interface Last Rev ised: 1/13/ 2009.
AMX Limited Warr anty and Disclaimer AMX warrant s it s pro ducts to be free of defect s in materia l and wor kmanshi p under n ormal use for three (3) years from the date of purc hase from AMX, with .
Table of Contents i NXP-CPI16 NetLinx Custom Panel Interface Table of Contents Product I nformation ....... .......... ..... ....... ......... ..... ........ ......... ..... ....... .......... ..... .... 1 Specifications ... ..........................
.
Produc t Info rma tion 1 NXP-CPI16 NetLinx Custom Panel Interfa ce Product Information The AMX NXP-CPI16 is a NetLinx panel device that allows sys tem integrators to connect switches, indicators, and rotary encoders to a NetLinx control system.
2 NXP-CPI16 NetLinx Custom Panel Interfa c e Specifications The table below lists the NXP-CPI1 6 specifications. NXP-CPI16 Specifications Power Requirement 12 VDC (300 m A ma x.
3 NXP-CPI16 NetLinx Custom Panel Interfa ce Input and Output Conne ctors T o install the NXP-CPI16, connect r ibbon cables or a PC b oard to one or more of the h eaders. The table belo w shows the pinouts for the two 20-pin headers. Quadrature Connectors The table below lists th e connector pinouts for the quadrature connector .
4 NXP-CPI16 NetLinx Custom Panel Interfa c e Quad ratur e Input s By default, the quadrature inputs e xpect the phase relationship, shown in FIG. 2, for a clockwise rotation of the encoder to generate a positiv e level change. If the phase relationship does not match the e xample, a clockwise rotation will generate a negati ve lev e l change.
Progra mming 5 NXP-CPI16 NetLinx Custom Panel Interfa ce Programming There are two modes of Channel A ssign ments: Discrete Outp ut and Def au lt Mode.
Send_Commands Use the Send_Commands listed in the table belo w to program the NXP-CPI16. Send_Commands BMODE Configures either set of 8 outp uts as an 8-segment bar- graph display .
7 NXP-CPI16 NetLinx Custom Panel Interfa ce Send_Commands (Cont.) LV L _ S Z Sets the size (data type) of the value that will be used by the NXP-CPI16 when receiving and sending LEVEL messages. The default is byte (8-bits), which yields a rang e of 0 - 2 55 for the level value.
8 NXP-CPI16 NetLinx Custom Panel Interfa c e The NXP-CPI16 uses input channels to rep ort user input on the contacts or switches attached to the input terminals. Output channels are used to turn on the lamp or LED display de vice s to indicate the b utton status to the user .
9 NXP-CPI16 NetLinx Custom Panel Interfa ce Each of the two 20-pin connectors is assign ed a group of 8 input and output channels. The table belo w sho ws the relation of input and output channels in the ST A TUS modes. The NXP-CPI16 may be configured to default to ST A TUS- ON mode using the follo wing method.
10 NXP-CPI16 NetLinx Custom Panel Interfa c e.
System Worksheets 11 NXP-CPI16 NetLinx Custom Panel Interfa ce System Worksheets Header 1 Header 2 Dealer ID Date Dealer PO Number Job SO Number Description Serial Number Rev Number Device Number CH1 .
CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 Out In Out In Out In Out In Out In Out In Out In Out In 9 10 11 12 Ground Po w e r Ground Ground 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20.
.
1/09 © 2009 AM X. All right s reserved . AMX and the AMX logo ar e registered trademarks of AMX. A MX reserves t he right to alter spec ific ations without notice at any time. It’s Y ou r W orld - T ak e Co ntr ol™ 3000 RESEARCH DR IVE, RICHARDSON, TX 75082 USA • 800.
Een belangrijk punt na aankoop van elk apparaat AMX NetLinx Custom Panel Interface NXP-CPI16 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen AMX NetLinx Custom Panel Interface NXP-CPI16 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens AMX NetLinx Custom Panel Interface NXP-CPI16 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding AMX NetLinx Custom Panel Interface NXP-CPI16 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over AMX NetLinx Custom Panel Interface NXP-CPI16 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van AMX NetLinx Custom Panel Interface NXP-CPI16 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de AMX NetLinx Custom Panel Interface NXP-CPI16 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met AMX NetLinx Custom Panel Interface NXP-CPI16 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.